• Title/Summary/Keyword: 가변 타원체 모형화 기술

Search Result 3, Processing Time 0.017 seconds

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Analyses of the indispensible Indices in Evaluating Gamma Knife Radiosurgery Treatment Plans (감마나이프 방사선수술 치료계획의 평가에 필수불가결한 지표들의 분석)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.303-312
    • /
    • 2017
  • The central goal of Gamma Knife radiosurgery(GKRS) is to maximize the conformity of the prescription isodose surface, and to minimize the radiation effect of the normal tissue surrounding the target volume. There are the various kinds of indices related with the quality of treatment plans such as conformity index, coverage, selectivity, beam-on time, gradient index(GI), and conformity/gradient index(CGI). As the best treatment plan evaluation tool, we must check by all means conformity index, GI, and CGI among them. Specially, GI and CGI related with complication of healthy normal tissue is more indispensible than conformity index. Then author calculated and statistically analysed CGI, the newly defined conformity/gradient index as well as GI being applied widely using the treatment planning system Leksell GammaPlan(LGP) and the verification method Variable Ellipsoid Modeling Technique(VEMT). In the study 10 patients with intracranial lesion treated by GKRS were included. Author computed the indices from LGP and VEMT requiring only four parameters: the prescribed isodose volume, the volume with dose > 30%, the target volume, and the volume of half the prescription isodose. All data were analyzed by paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in GI at 10 cases was observed between LGP and VEMT. Differences in GI ranged from -0.14 to 0.01. The newly defined gradient index calculated by two methods LGP and VEMT was not statistically significant either. Author did not find out the statistical difference for the prescribed isodose volume between LGP and VEMT. CGI as the evaluation index for determining the best treatment plan is not significant statistically also. Differences in CGI ranged from -4 to 3. Similarly newly defined Conformity/Gradient index for GKRS was also estimated as the metric for the evaluation of the treatment plans through statistical analysis. Statistical analyses demonstrated that VEMT was in excellent agreement with LGP when considering GI, new gradient index, CGI, and new CGI for evaluating the best plans of GKRS. Due to the application of the fast and easy evaluation tool through LGP and VEMT author hopes CGI and newly defined CGI as well as gradient indices will be widely used.

A Comparison of the Independent Verification Methods for the Results of Leksell GammaPlan for Gamma Knife Predecessor with the Hemispherical Collimators (반구형 시준기를 가진 감마나이프에 대한 렉셀감마플랜 결과물의 독립적인 검증방법들의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.521-529
    • /
    • 2016
  • Since Gamma Knife(R) radiosurgery(GKRS) is based on a single-fraction high dose treatment strategy, independent verification for the results of Leksell GammaPlan(R) (LGP) is an important procedure in assuring patient safety and minimizing the risk of treatment errors. Several verification methods have been developed and reported previously. Thus these methods were tested statistically and tried on Leksell Gamma Knife(LGK) target treatments through the embodiment of the previously proposed algorithms(PPA). The purpose of this study was to apply and evaluate the accuracy of verification methods for LGK target treatments using PPA. In the study 10 patients with intracranial lesion treated by GKRS were included. We compared the data from PPA and LGP in terms of maximum dose, arbitrary point dose, and treatment time at the isocenter locations. All data were analyzed by Paired t-test, which is statistical method used to compare two different measurement techniques. No statistical significance in maximal dose at 10 cases was observed between PPA and LGP. Differences in average maximal dose ranged from -0.53 Gy to 3.71 Gy. The arbitrary point dose calculated by PPA and LGP was not statistically significant too. But we found out the statistical difference with p=0.021 between TMR and LGP for treatment time at the isocenter locations. PPA can be incorporated as part of a routine quality assurance(QA) procedure to minimize the chance of a wrong overdose. Statistical analyses demonstrated that PPA was in excellent agreement with LGP when considering the maximal dose and the arbitrary point dose for the best plan of GKRS. Due to the easy applicability we hope PPA can be widely used.