• 제목/요약/키워드: 가변온도형 열선유속계

검색결과 4건 처리시간 0.024초

온도변화를 고려한 가변온도형 열선유속계의 교정식 (Calibration Equation for VTA Including the Effect of Ambient Temperature Drift)

  • 이신표;고상근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.99-104
    • /
    • 2000
  • Calibration equation for Variable Temperature Anemometer(VTA) has been tested for measured velocity-output data and the calibration process has been compared with that of Constant Temperature Anemometer(CTA). VTA has greater sensitivity than that of any other conventional anemometers, but to be more popular technique in flow field measurement, simple, accurate and well established calibration process should be suggested. To meet this purpose, similar calibration method used for CTA has been adopted for VTA and finally calibration equation for VTA including the effect of temperature drift has been proposed.

  • PDF

광도전성저항 안정화회로를 채택한 가변온도형 열선유속계의 출력특성에 관한 실험적 연구 (Experimental Study on Output Characteristics of a Variable Temperature Anemometer Adopting a Photoconductive Cell and Stabilizing Circuit)

  • 이신표
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1201-1208
    • /
    • 2001
  • Variable temperature anemometer(VTA) has greater sensitivity than a conventional constant temperature anemometer(CTA). In order to design a reliable VTA system, however, an elaborate photoconductive cell stabilizing circuit which plays a key role in setting wire-overheat ratio should be firstly developed. In this study, a stabilizing circuit which adopts proportional-integral analog controller was proposed and thoroughly tested for its accuracy and reproducibility. In contrast to the available circuit suggested by Takagi, the present circuit has characteristic that the resistance of a photoconductive cell increases with the increase of input voltage, which makes the current circuit very suitable for the design of VTA. Finally, VTA adopting stabilizing circuit was made and the enhanced sensitivity of the VTA was validated experimentally by comparing the calibration curves of VTA and CTA.

유속에 따른 열선의 과열비 조정을 통한 열선유속계의 감도향상에 관한 연구 (Sensitivity Enhancement of a Hot-Wire Anemometer by Changing Overheat Ratio with Velocity)

  • 이신표;고상근
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2678-2689
    • /
    • 1995
  • In this study, a new hot-wire anemometer which has greater sensitivity than that of a constant temperature anemometer (CTA) was proposed. In contrast to CTA, the wire working resistance of the new anemometer increases with flow velocity, that is, the operating mode of the wire becomes variable temperature. The variable temperature anemometer(VTA) was made by substituting a voltage controlled variable resistor such as photoconductive cell or transistor for one of the resistors in the bridge. By positively feeding back the bridge top signal to the input side of these electronic components, the wire overheat ratio could be increased with velocity automatically. Static response analyses of the VTA, constant voltage anemometer (CVA) and CTA were made in detail and calibration experiments were performed to validate the proposed operating principle. The wire operating resistance of the CVA decreases with velocity and this leads to lower sensitivity than that of a CTA. But the sensitivity of the newly proposed VTA is superior to that of a CTA, since the wire overheat ratio increases with velocity. Consequently, it is found that the major factor that is responsible for large sensitivity of a VTA is not the working resistance itself but the change of the wire working resistance with velocity.