• Title/Summary/Keyword: 가동조건

Search Result 305, Processing Time 0.019 seconds

Development of a deep-learning based tunnel incident detection system on CCTVs (딥러닝 기반 터널 영상유고감지 시스템 개발 연구)

  • Shin, Hyu-Soung;Lee, Kyu-Beom;Yim, Min-Jin;Kim, Dong-Gyou
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.915-936
    • /
    • 2017
  • In this study, current status of Korean hazard mitigation guideline for tunnel operation is summarized. It shows that requirement for CCTV installation has been gradually stricted and needs for tunnel incident detection system in conjunction with the CCTV in tunnels have been highly increased. Despite of this, it is noticed that mathematical algorithm based incident detection system, which are commonly applied in current tunnel operation, show very low detectable rates by less than 50%. The putative major reasons seem to be (1) very weak intensity of illumination (2) dust in tunnel (3) low installation height of CCTV to about 3.5 m, etc. Therefore, an attempt in this study is made to develop an deep-learning based tunnel incident detection system, which is relatively insensitive to very poor visibility conditions. Its theoretical background is given and validating investigation are undertaken focused on the moving vehicles and person out of vehicle in tunnel, which are the official major objects to be detected. Two scenarios are set up: (1) training and prediction in the same tunnel (2) training in a tunnel and prediction in the other tunnel. From the both cases, targeted object detection in prediction mode are achieved to detectable rate to higher than 80% in case of similar time period between training and prediction but it shows a bit low detectable rate to 40% when the prediction times are far from the training time without further training taking place. However, it is believed that the AI based system would be enhanced in its predictability automatically as further training are followed with accumulated CCTV BigData without any revision or calibration of the incident detection system.

Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy (방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.77-88
    • /
    • 1998
  • Wedge shaped isodoses are desired in a number of clinical situations. Hard wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths along with the practical consequendes of filter handling and placement problems. Dynamic wedging uses a combination of a moving collimator and changing monitor dose to achieve angled isodoses. The segmented treatment tables(STT) that monitor unit setting by every distance of moving collimator, was induced by numerical formular. The characteristics of dynamic wedge by STT compared with real dosimetry. Methods and Materials : The accelerator CLINAC 2100C/D at Yonsei Cancer Center has two photon energies (6MV and 10MV), currently with dynamic wedge angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$. The segmented treatment tables(STT) that drive the collimator in concert with a changing monitor unit are unique for field sizes ranging from 4.0cm to 20.0cm in 0.5cm steps. Transmission wedge factors were measured for each STT with an standard ion chamber. Isodose profiles, isodose curves, percentage depth dose for dynamic wedge filters were measured with film dosimetry. Dynamic wedge angle by STT was well coincident with film dosimetry. Percent depth doses were found to be closer to open field but more shallow than hard wedge filter. The wedge transmission factor were decreased by increased the wedge angle and more higher than hard wedge filters. Dynamic wedging probided more consistent gradients across the field compared with hard wedge filters. Dynamic wedging has practical and dosimetric advantages over hard filters for rapid setup and keeping from table collisions. Dynamic wedge filters are positive replacement for hard filters and introduction of dynamic conformal radiotherapy and intensity modulation radiotherapy in a future.

  • PDF

A Study on the Water Exchange Plan with Disaster Prevention Facilities in Masan Bay (마산만 재해방지시설을 이용한 해수교환 방안에 관한 연구)

  • Kim, Gweon-Su;Ryu, Ha-Sang;Kim, Kang-Min
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.637-645
    • /
    • 2013
  • Masan bay with a semi-enclosed waters has serious water quality problems due to the low flow and river pollution load from land, and shows the vulnerable locational characteristics to storm surge. We are seeking the way of both operating disaster prevention facilities and water quality improvement measures in the bay. That is, the water was exchanged using the head difference occurred by operating disaster prevention facilities. The location of disaster prevention facilities was assumed to be in the inlet of the bay, in the vicinity of Machang bridge, and in the vicinity of Dot island and the operation time was assumed to be early morning hours(01~05) considering the number of shipping passage and annual tide, and spring tide of the largest head difference. In addition, the experiment case of water exchange including the in-outflow feeder pipe was tested. According to the simulation results, water exchange rate in all experiments has shown a steady increase. Water exchange rate of the whole of Masan bay in the case of present is 38.62%. The water exchange rate of the inside of Masan bay compared with the inlet of bay, appeared to be very low. Thus, we judged that the characteristics of semi-enclosed waters were well reproduced. On the results of the experiment of disaster prevention facilities and in-outflow feeder pipe, the case of the operation of disaster prevention facilities, water exchage rate is high compared with the case of present. And, the higer the operating frequency, the more water exchange is appeared. The cases of water exchange prevention facilities through the in-outflow feeder pipe caused by the head difference, also showed the higest improvement of the water quality. Compared with the south of Machang bridge, the effect of water exchange was better in the inlet of Masan bay and Dot island. On the other hand, the inlet of Masan bay is higer than Dot island as for water exchange of the whole of Masan bay, but opposite, water change rate including Masan inside was higher in the case of Dot island.

Investigation of ground condition charges due to cryogenic conditions in an underground LNG storage plant (지하 LNG 저장 시험장에서 극저온 환경에 의한 지반상태 변화의 규명)

  • Yi Myeong-Jong;Kim Jung-Ho;Park Sam-Gyu;Son Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2005
  • To investigate the feasibility of a new concept of storing Liquefied Natural Gas (LNG) in a lined hard rock cavern, and to develop essential technologies for constructing underground LNG storage facilities, a small pilot plant storing liquid nitrogen (LN2) has been constructed at the Korea Institute of Geoscience and Mineral Resources (KIGAM). The LN2 stored in the cavern will subject the host rock around the cavern to very low temperatures, which is expected to cause the development of an ice ring and the change of ground condition around the storage cavern. To investigate and monitor changes in ground conditions at this pilot plant site, geophysical, hydrogeological, and rock mechanical investigations were carried out. In particular, geophysical methods including borehole radar and three-dimensional (3D) resistivity surveys were used to identify and monitor the development of an ice ring, and other possible changes in ground conditions resulting from the very low temperature of LN2 in the storage tank. We acquired 3D resistivity data before and after storing the LN2, and the results were compared. From the 3D images obtained during the three phases of the resistivity monitoring survey, we delineated zones of distinct resistivity changes that are closely related to the storage of LN2. In these results, we observed a decrease in resistivity at the eastern part of the storage cavern. Comparing the hydrogeological data and Joint patterns around the storage cavern, we interpret this change in resistivity to result from changes in the groundwater flow pattern. Freezing of the host rock by the very low temperature of LN2 causes a drastic change in the hydrogeological conditions and groundwater flow patterns in this pilot plant.

Effects of Local Cooling and Root Pruning on Budding and Local Heating on Heating Energy Consumption in Forcing Cultivation of Strawberry (딸기 촉성재배 시 국소 냉방 및 단근처리와 국소난방이 화방출뢰와 난방에너지소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Suk Won;Paek, Yee;Moon, Jong Pil;Jang, Jae Kyung;Oh, Sung Sik
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.46-54
    • /
    • 2019
  • Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry 'Seolhyang' using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at $18{\sim}22^{\circ}C$. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above $30^{\circ}C$. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone $20^{\circ}C$+inside greenhouse $5^{\circ}C$) and crown local heating(crown $20^{\circ}C$+inside greenhouse $5^{\circ}C$) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse $9^{\circ}C$). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.