• Title/Summary/Keyword: 가동온도

Search Result 233, Processing Time 0.029 seconds

Corrosion Behavior of Dolomite Clinkers by Molten Steel (용강에 의한 돌로마이트 클링커의 침식거동)

  • 박재원;홍기곤
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.12
    • /
    • pp.1301-1307
    • /
    • 1998
  • For dolomite clinkers used as stamp materials the corrosion behavior of those by molten steel was investigated in therange of temperatures between 1550$^{\circ}C$ and 1600$^{\circ}C$ IN hot face the dicalciumferrite of magnesioferrite and dicalciumferrite formed within dolomite clinkers was preferentially dissolved into molten steel and the protective layer of magnesioferrite was formed. For dolomite clinker without Fe2O3 magnesioferrite maintained the skeleton of MgO while the skeleton of CaO disappered bythe formation of dicalciumferrite and it existed as grain boundary phases of magnesioferrite. For dolomite clinker with Fe2O3 was diffused into hot face by the decomposition of dicalciumferrite. With increasing temperature of molten steel the formation depth of dicalciumferrite was increased and the magnesioferrite layer in hot face was decreased for dolomite clinker without Fe2O3 while the layer thickness and grain sizes of magnesioferrite in hot face was decreased for dolomite clinker without Fe2O3 while the layer thickness an grain sizes of magnesioferrite in hot face was increased due to the increment of the decomposition reaction of dicalciumferrite for dolomite clinker with Fe2O3.

  • PDF

Retraction: A numerical study on the fire smoke behavior by operating the fire prevention system in tunnel-type structure (논문 취소: 터널형 구조물의 방재시설 가동에 따른 화재연기 거동에 관한 수치 해석적 연구)

  • Lee, Ho-Hyung;Choi, Pan-Gyu;Lee, Sang-Don;Heo, Won-Ho;Jo, Jong-Bok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.189-199
    • /
    • 2019
  • In this study, behaviors of fire smoke in the operation of disaster prevention facilities (smoke damper, jet fan) in a tunnel-type structure (soundproof tunnel) were investigated numerically and results of the investigation were compared and analyzed. Through the simulation and analysis, it was found that there was a significant change in the patterns of fire smoke between the opening of the ceiling of a fire vehicle and the closing, and it was shown that the critical temperatures of PC and PMMA, main materials of a soundproof tunnel were not exceeded. In addition, the simulation of installation intervals of smoke dampers showed that the maximum temperature of a soundproof tunnel without smoke dampers was $552^{\circ}C$ while it reached $405^{\circ}C$ when smoke dampers were installed at the installation interval of 50 m. The simulation of the operation of a jet fan showed that the maximum temperature of a soundproof tunnel without a jet fan was $549^{\circ}C$ while it reached only $86^{\circ}C$ when a jet fan was operating. Therefore, it is highly expected that they could create a favorable environment for evacuation and protection of soundproofing materials, and it would be necessary to promote basic studies on tunnels serving various functions and purposes.

냉동저장고 주변의 온도분포에 관한 현장 계측 및 수치해석

  • Lee, Gyu-Sang;Lee, Jeong-In
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2004.04a
    • /
    • pp.101-110
    • /
    • 2004
  • 지하냉동 저장고 주변의 온도분포를 예측하기 위하여 국내 최초로 건설된 상업적 규모의 지하암반 저장고인 '곤지암 지하암반 저장고'에 대한 약 5년간의 암반 온도 계측 결과와 FLAC을 이용한 2차원 및 3차원 수치해석 결과를 비교하였다. 수치해석 수행 시 지하수, 지하수의 동결잠열, 지표온도의 영향을 고려하였으며, 각각의 요소가 지하암반 온도분포에 미치는 영향을 계측자료와의 비교를 통하여 분석하였다. 각각의 경우에 대한 2차원 수치해석과 계측결과를 비교한 결과 지하수와 동결잠열을 같이 고려한 경우가 지하수의 영향만 고려한 경우에 비해 오차가 적게 나타났으며, 2차원 해석에서는 냉동기 가동 시간이 경과하면서 지표면의 영향으로 오차가 커지는 경향이 나타났다. 3차원 수치해석은 지표까지 거리의 영향을 고려하여 수행하였으며, 해석결과 2차원과 같이 지하수 및 동결잠열의 영향이 고려된 해석이 가장 작은 오차를 나타내었으며, 시간의 경과에 따른 오차의 증가는 없었다.

  • PDF

A Study on the Remote Temperature-Control System (원격 온도제어시스템에 관한 연구)

  • Hou, Bo-Jun;Wu, Wei;Zhang, Hong-ting;Sim, Young-chan;Kim, Woong-Sik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.23-24
    • /
    • 2009
  • 분 논문에서는 원격 온도제어시스템을 연구하였다. 원격계측 센서를 이용하여 비닐하우스 내의 온도정보를 수집하고 이 데이터를 무선통신을 이용하여 서버에 전송 후 온도제어 정보를 다시 히터시스템에 전달한다. 옥내에서 비닐하우스 내 온도변화를 파악하고 원격으로 히터시스템을 가동할 수 있다.

Performance Evaluation of Rahman-type Movable Joint System for Temporary Bridge (단부 수평가동-수직구속 부재를 적용한 라멘형 가설교량의 거동평가)

  • Kim, Sang Hyo;Joung, Jung Yeun;Heo, Won Ho;Jung, Chi Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.1-13
    • /
    • 2013
  • Most rahmen-type temporary bridges are constructed with limited bridge length to prevent excessive horizontal forces due to the thermal expansion of main girder. To achieve a long length temporary bridge several independent bridges are required and they can not share the bents, at the rahmen-type ends, with the adjacent ones. The additional bents require more cost and reduce the section space under bridges. In order to remove extra bents with keeping the rahmen effect at the bridge ends, this study proposes a new rahmen-type movable joint system for temporary bridges.

Analysis of Regional Relative Humidity Environment for Dehumidification System Efficiency of Suspension Bridge Cable (현수교 케이블 송기시스템 효율화를 위한 지역별 상대습도 환경 분석)

  • Seo, Dong-Woo;Kim, Ga Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.88-94
    • /
    • 2018
  • This study examined the safety of a cable stayed bridge caused by damage to the cable system. Many cable-supported bridges, including cable-stayed bridges and suspension bridges, have been constructed on the Korean peninsula. This requires efficient maintenance and management because this structure has complex structural components and systems. This large structure also often faces risks either from manmade causes or natural phenomena. In 2015, the cables on one cable-stayed bridge in South Korea was struck by lightning, which led to a fire on the cables. These cables were damaged, which put the bridge at risk. This bridge was back in use after a few weeks of investigations and replacements of the cables but this was done at enormous social and economic expense. After this event, risk-based management for infrastructure is required by public demand. Therefore, this study examined the risks on the cable system due to potential damage. In this paper, a one cable-stayed bridge in South Korea was selected and its safety was investigated based on the damage scenarios of cable system for efficient and prompt management, and to support decision making. FEM analysis was conducted to evaluate the safety of the bridges after damage to the cable system.

An Experimental Study on the Fire Risk of Electric Heaters According to Contact of Flammable Materials (가연물 접촉에 따른 전기히터의 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • In this study, it was evaluated the fire risk of an electric heater as representative seasonal appliances. Two type of electric heaters were used in experiments. When electric heaters were operated, temperature variation was measured around the heater. Internal structure was understood by Nondestructive inspection. It was evaluated the tire risk of electric heaters, when flammable materials were positioned ear a heater. It was also estimated the probability of a tire in case of malfunction of a safety tip-over witch. When a heater was operated in a normal condition, temperature was maintained under $80^{\circ}C$ around the heater. The possibility of a fire is very high, when a heater is covered with flammable materials or malfunction of safety parts (safety tip-over switch, anti-overheating devices).

An Experimental Study of Smoke Control in Tunnel Fires with Jet Fan (터널화재시 제트팬에 의한 연기제어에 관한 실험적 연구)

  • 이성룡;김충익;유홍선;방기영
    • Tunnel and Underground Space
    • /
    • v.12 no.2
    • /
    • pp.92-98
    • /
    • 2002
  • In this study reduced-scale experiments were conducted to analyze smoke movement in tunnel fire with jet fan, The 1/20 scale experiments were carried out under the froude scaling using gasoline pool fire range from 6.6 to 12.5 cm in diameter with total heat release rate from 0.714 to 4.77 kW. In the case of fires under the 2.5kW, backlaying was reduced about 40cm and smoke was effectively controled in downstream of the fan when operating the fan. The smoke layer was moved down and the ceiling temperature was decreased compared to that of without fan case in upstream of the fan, but the temperature in the lower part of the tunnel was increased.

증기발생기 건전성관련 고온관의 적정온도 설정을 위한 분석

  • 민경성;한규성;박순희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.437-443
    • /
    • 1995
  • 국내, 외에서 원자력발전소의 주요 구성 기기인 증기발생기의 세관 건전성과 관련 설계개선을 위한 연구가 활발히 진행되고 있다[2,3,4,5,6]. 현재 가동중인 발전소에서는 개선된 증기발생기로 교체하고자 하는 검토가 이루어지고 있으며, 설계중인 발전소에서는 중기발생기의 건전성을 향상시키기 위한 노력이 진행되고 있다. 본 논문에서 기존에 조사되고 검토된 자료를 바탕으로 [2] 현재까지 주로 사용되어온 증기발생기의 세관 재질을 인코넬 600 MA(mill annealed)로 사용할 때 40년 수명동안 증기발생기의 건전성을 보장할 수 있는 고온관의 온도를 분석한 결과 적절한 온도가 607$^{\circ}$F(319.4$^{\circ}C$)임을 알았다. 그리고 이 온도를 반영할 때 계통설계에 영향을 주는 설계사항에 대하여 검토하였고, 추가로 인코넬 600 MA보다 고온조건에서 건전성이 양호한 인코넬 690 TT(thermal treatment)를 사용할 때 설계에 미치는 영향도 검토하였다. 이러한 분석결과는 추후 국내 원자력발전소에서 보다 증기발생기의 건전성을 보장하기 위해 설계개선을 하고자 할 때 기초 자료가 되리라 판단한다.

  • PDF

A Study on the Unsteady Temperature Characteristics at the Refrigerator Gasket Region (냉장고 가스켓 주위의 시간에 따른 온도변동 특성에 관한 연구)

  • Ha, Ji Soo
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.138-143
    • /
    • 2012
  • The present study has been carried out to elucidate the unsteady temperature characteristics of a refrigerator near gasket region by measuring time dependent temperature measurements. From the measured values of the time dependent temperature inside and outside region of a refrigerator, one could see that the temperature varies periodically with time from the effect of refrigerator operation. The measured mean temperatures at the wall had great different value from the previous other research results conducted by numeric ofheat transfer using improperfheat transfer boundary condition. The present study could give the experiment ofdata for the properfnumeric ofheat transfer an oysis and suggest more accuratefheat transfer boundary conditions for the inside and outside of a refrigerator.