• Title/Summary/Keyword: 가동온도

Search Result 234, Processing Time 0.028 seconds

A Study on Cooling Condition for Quality Improvement of Rotary Molding Machine (회전성형기의 품질 향상을 위한 냉각 조건에 관한 연구)

  • Kang, Jeong-Seok;Kim, In;Lee, Myungjae;Yoon, Jai-young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.367-371
    • /
    • 2019
  • The molding for hollow products used widely in industry is rotational molding by heating and cooling. Uniform cooling is required to improve the quality of the product, and rapid cooling is required to improve the productivity. In this paper, the cooling condition is largely classified into the case of no forced cooling by the fan and forced cooling by the fan. In addition, when forced cooling by the fan is not performed, the condition for stopping the molding machine horizontally and the condition for stopping the molding machine vertically were classified. To confirm the forced cooling by the fan, the conditions were set such that only the molding machine rotates while the fan is not running and the upper and lower fans operate when only the lower fan is operated. The surface temperature of the rotary molding machine was analyzed by the STAR-CCM+ program for the case of air-cooling. The temperature distribution of the rotary molding machine was analyzed for five conditions and the temperature distribution for cooling was compared under each condition. Among the five cases, Case 4 was lowest at approximately 35 ℃ after 900sec.

Enhancement of the Life of Refractories through the Operational Experience of Plasma Torch Melter (플라즈마토치 용융로 운전경험을 통한 내화물 수명 증진 방안)

  • Moon, Young Pyo;Choi, Jang Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2016
  • The properties of wastes for melting need to be considered to minimize the maintenance of refractory and to discharge the molten slags smoothly from a plasma torch melter. When the nonflammable wastes from nuclear facilities such as concrete debris, glass, sand, etc., are melted, they become acid slags with low basicity since the chemical composition has much more acid oxides than basic oxides. A molten slag does not have good characteristics of discharge and is mainly responsible for the refractory erosion due to its low liquidity. In case of a stationary plasma torch melter with a slant tapping port on the wall, a fixed amount of molten slags remains inside of tapping hole as well as the melter inside after tapping out. Nonmetallic slags keep the temperature higher than melting point of metal because metallic slags located on the bottom of melter by specific gravity difference are simultaneously melted when dual mode plasma torch operates in transferred mode. In order to minimize the refractory erosion, the compatible refractories are selected considering the temperature inside the melter and the melting behavior of slags whether to contact or noncontact with molten slags. An acidic refractory shall not be installed in adjacent to a basic refractory for the resistibility against corrosion.

An Experimental Study on Radiation/Convection Hybrid Air-Conditioner (복사-대류 겸용 하이브리드 냉방기에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.288-296
    • /
    • 2019
  • Radiation cooling has used ceilings or floors as cooling surfaces. In such cases, to avoid moisture condensation on the surface, the surface temperature needs be higher than the dew point temperature or an additional dehumidifier is added. In this study, with a goal for residential application, intentional moisture condensation on the cooling surface was attempted, which increased the cooling capacity and improved the indoor comfortness. This method included two separate refrigeration cycles - convection-type dehumidifying cycle and the panel cooling cycle. Test results on the panel cooling cycle showed that, at the standard outdoor ($35^{\circ}C/24^{\circ}C$) and indoor ($27^{\circ}C/19.5^{\circ}C$) condition, the refrigerant flow rate was 8.8 kg/h, condensation temperature was $51^{\circ}C$, evaporation temperature was $8.8^{\circ}C$, cooling capacity was 376 W and COP was 1.75. Furthermore, the panel temperature was uniform within $1^{\circ}C$ (between $13^{\circ}C$ and $14^{\circ}C$). As the relative humidity decreased, the cooling capacity decreased. However, the power consumption remained approximately constant. In the convection-type dehumidification cycle, the refrigerant flow rate was 21.1 kg/h, condensation temperature was $61^{\circ}C$, evaporation temperature was $5.0^{\circ}C$, cooling capacity was 949 W and COP was 2.11 at the standard air condition. When both the radiation panel cooling and the dehumidification cycle operated simultaneously, the cooling capacity of the radiation panel cycle was 333 W and that of the dehumidification cycle was 894 W, and the COP was 1.89. As the fan flow rate decreased, both the cooling capacity of the radiation panel and the dehumidification cycle decreased, with that of the dehumidification cycle decreasing at a higher rate. Finally, a possible control logic depending on the change of the cooling load was proposed based on the results of the present study.

Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture (시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석)

  • Ryou, Young-Sun;Kang, Youn-Ku;Kang, Geum-Chun;Kim, Young-Joong;Paek, Yee
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.90-95
    • /
    • 2008
  • It has become a big matter of concerns that the skill and measures against reduction of energy and cost for heating a protected horticultural greenhouse were prepared. But in these days necessity of cooling a protected horticultural greenhouse is on the rise from partial high value added farm products. In this study, therefore, a horizontal type geothermal heat pump system with 10 RT scale to heat and cool a protected horticultural greenhouse and be considered to be cheaper than a vertical type geothermal heat pump system was installed in greenhouse with area of $240\;m^2$. And cooling performances of this system were analysed. As condenser outlet temperature of heat transfer medium fluid rose from $40^{\circ}C$ to $58^{\circ}C$, power consumption of the heat pump was an upturn from 11.5 kW to 15 kW and high pressure rose from 1,617 kPa to 2,450 kPa. Cooling COP had the trend that the higher the ground temperature at 1.75 m went, the lower the COP went. The COP was 2.7 at ground temperature at 1.75 m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$ and the heat extraction rate from the greenhouse were 28.8 kW, 26.5 kW respectively at the same ground temperature range. 8 hours after the heat pump was operated, the temperature of ground at 60 cm and 150 cm depth buried a geothermal heat exchanger rose $14.3^{\circ}C$, $15.3^{\circ}C$ respectively, but the temperature of ground at the same depth not buried rose $2.4^{\circ}C$, $4.3^{\circ}C$ respectively. The temperature of heat transfer medium fluid fell $7.5^{\circ}C$ after the fluid passed through geothermal heat exchanger and the fluid rejected average 46 kW to the 1.5 m depth ground. It analyzed the geothermal heat exchanger rejected average 36.8 W/m of the geothermal heat exchanger. Fan coil units in the greenhouse extracted average 28.2 kW from the greenhouse air and the temperature of heat transfer medium fluid rose $4.2^{\circ}C$after the fluid passing through fan coil units. It was analyzed the accumulation energy of thermal storage thank was 321 MJ in 3 hours and the rejection energy of the tank was 313 MJ in 4 hours.

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

Development of Multi-Touch/Context-Aware Convergence Digital Signage System based on Android OS Platform (안드로이드 플랫폼 기반 멀티 터치/상황인지형 융복합 디지털 사이니지 시스템 개발)

  • Nahm, Eui-Seok
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.245-251
    • /
    • 2015
  • If a digital signage system is operated in PC mounted in the Window OS then the implementing price is very high. For resolving this problem, we used the Smartphone mounted in ARM Cortex family of multi-core processor-based mobile platform. We developed a low-power low-cost digital signage system and a remote convergence content management program based on web server. This convergence system manages advertising content to a remote control device anywhere using remote control technology. This system is one integrated system with display and is a low-power consumed and is developed in very efficient hardware interface. And condition sensors(intensity of illumination, temperature, weather, GPS etc) is equipped in the developed system. Automatic contents builder and Context-aware SMIL module is also implemented in the convergence system. We achieved over 50% power savings comparing with conventional Window OS system and 16 points multi-touch in our system.

Study on the Continuous Composting Process to Reduce the Use of Bulking Agent in Pig Slurry (톱밥 절감형 돈분 슬러리 연속 퇴비화 공정 연구)

  • Ryoo, J,.W.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.121-128
    • /
    • 2007
  • To develop the composting system to reduce the use of bulking agent, continuous composting was performed with farmer scale facility, The plant comprises a horizontal pit reactor closed inside a greenhouse and equipped with a turning machine moving on rails. The pit was 9m wide and 50m long and the maximum height of loaded materials was $1.8m^2$. The materials remained in the reactor for 5 months. During the composting process, temperature and water content measured and water balance was evaluated. The reaction temperature of composting was changed $30{\sim}50^{\circ}C$ and high in the middle and low in under composting piles. The moisture contents of the compost were approximately 70% during the experiment. The amount of effluent was 10.6% and $3.16m^3$ of pig slurry per $1m^3$ of bulking agent was treated during continuous composting process. BOD and SS reduction of the effluent in continuous composting was 86.5% and 92.2%, respectively. Indoor relative humidity in night time was changed between 80 and 100%.

  • PDF

Assessment of Geothermal Energy Resources of Korea (한국의 지열에너지 부존량 산출)

  • Park, Sung-Ho;Lee, Young-Min;Kim, Jong-Chan;Kim, Hyoung-Chan;Koo, Min-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.617-620
    • /
    • 2008
  • 지열에너지는 지구 내부의 깊은 곳에서부터 발생하는 열과 상부 지각에서 방사성 동위원소의 붕괴에 의한 열에 의해 발생한다. 지열에너지는 다른 신재생에너지(수력, 풍력, 태양력, 조력, 바이오 매스등)에 비하여 가동효율이 높고, 지속가능한 재활용 자원으로 경제적 효율성이 높아 전 세계적으로 활용도와 잠재성이 높은 신재생에너지의 하나로 각광 받고 있다. 따라서, 지열에너지의 사용은 화석 연료 사용의 상당부분을 대체할 수 있고, 온실가스의 배출도 줄일 수 있다. 현재 우리나라의 지열에너지 이용은 저온성 지열에너지를 이용한 냉난방에 국한되어 있지만, 앞으로의 지열에너지 이용은 Enhanced Geothermal System(EGS) 을 이용한 지열에너지 개발에 초점이 맞추어질 것이다. 현재의 지열에너지 개발을 용이하게 하고, 또한 미래의 지열에너지 개발에 대비하여 우리나라의 이용가능한 지열에너지 부존량을 파악하기 위해 본 연구를 수행하였다. 연구 수행에는1560개 열물성 자료(밀도, 비열, 열전도도), 353개 지표 지열류량 자료, 180개 열생산율 자료와 54개의 지표온도 자료가 사용되었다. 우리나라의 지표에서부터 1 km 깊이 간격별로 5 km 깊이까지 지열에너지 부존량을 산출한 결과 지표에서 부터 5 km 깊이까지의 추출 가능한 지열에너지의 총 부존량은 $1.01{\times}10^{23}$ J로 산출되었다. 지열에너지 부존량을 Toe(석유환산톤) 로 환산하면 $2.40{\times}10^{12}$ Toe 가 된다. 추출한 지열에너지 자원의 2%를 사용한다고 가정 했을때 약 480억 Toe 이다. 이는 2006년 우리나라 전체 1차 에너지 총 소비량(2.33억 Toe)을 고려 했을때 약 200년 동안 사용할 수 있는 양이다.

  • PDF

Studies on the Selection of Microorganism for Food Wastes and Optimization of Fermentation Process (음식물찌꺼기 소멸효율 재고를 위한 발효균 및 발효 공정 최적화 연구)

  • Kim, Young-Kwon;Hong, Myung-Pyo;Kim, Myung-Jin;Hong, Suk-Il;Park, Myung-Suk;Kim, Jong-Suk;Chang, Ho-Geun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.2
    • /
    • pp.95-112
    • /
    • 1998
  • For the effective disposal of organic food wastes, we seleted 4 strains of microorganism from 186 microbial candidate via enzyme activity test, salt tolerance, food decomposition rate, stability and safety of strains. The identity of these 4 strains are as follows : Fungi is Rhizopus sp., yeasts are Galactomyces sp., Pichia sp. and Hyphopichia sp., In the 50L fermenter scale, we tested various fermenting factor for the optimization of conditions of food waste decomposition using 4 selected strains. The optimum fomenting conditions were as follows : BIO-CHIP Volume 25-30 L, BIO CHIP size 2.0-6.0mm, air flow 200-280L/min, mixing intensity 2-4rpm, temperature $30-45^{\circ}C$. In these fermenting conditions, the efficiency of decomposition(rate of weight loss of food wastes) were 93%. Also the quality of fermenting output were assayed at the basis of fertilizer, and the results were as good as general compost.

  • PDF

Formation of Oxy-Fuel MILD Combustion under Different Operating Conditions (가동조건 변화에 따른 순산소 마일드 연소 형성 연구)

  • Lee, Pil Hyong;Hwang, Sang Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.577-587
    • /
    • 2016
  • Although the formation of oxy-fuel MILD combustion is considered one of the promising combustion technologies for high thermal efficiency, low emissions and stability have been reported as difficulties. In this paper, the effect of combustor geometry and operating conditions on the formation of oxy-fuel MILD combustion was analyzed using numerical simulation. The results show that the high temperature region and average temperature decreased due to an increase in oxygen inlet velocity; moreover, a high degree of temperature uniformity was achieved using an optimized combination of fuels and an oxygen injection configuration without external oxygen preheating. In particular, the oxy-fuel MILD combustion flame was found to be very stable with a combustion flame region at equivalence ratio 0.90, fuel velocity 10 m/s, oxygen velocity 200 m/s, and nozzle distance 33.5 mm.