• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.031 seconds

Numerical Analysis of Steam-methane Reforming Reaction for Hydrogen Generation using Catalytic Combustion (촉매 연소를 열원으로 한 수증기-메탄개질반응 전산유체해석)

  • Lee, Jeongseop;Lee, Kanghoon;Yu, Sangseok;Ahn, Kookyoung;Kang, Sanggyu
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • A steam reformer is a chemical reactor to produce high purity hydrogen from fossil fuel. In the steam reformer, since endothermic steam reforming is heated by exothermic combustion of fossil fuel, the heat transfer between two reaction zones dominates conversion of fossil fuel to hydrogen. Steam Reforming is complex chemical reaction, mass and heat transfer due to the exothermic methane/air combustion reaction and the endothermic steam reforming reaction. Typically, a steam reformer employs burner to supply appropriate heat for endothermic steam reforming reaction which reduces system efficiency. In this study, the heat of steam reforming reaction is provided by anode-off gas combustion of stationary fuel cell. This paper presents a optimization of heat transfer effect and average temperature of cross-section using two-dimensional models of a coaxial cylindrical reactor, and analysis three-dimensional models of a coaxial cylindrical steam reformer with chemical reaction. Numerical analysis needs to dominant chemical reaction that are assumed as a Steam Reforming (SR) reaction, a Water-Gas Shift (WGS) reaction, and a Direct Steam Reforming(DSR) reaction. The major parameters of analysis are temperature, fuel conversion and heat flux in the coaxial reactor.

Heat Source Identification Technique of Aircraft and Flare using 2-color Detectable Infrared Sensors (복수 대역 감지 적외선 센서를 이용한 항공기와 플레어의 열원 식별 기술)

  • Lee, Dong-Si;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1031-1039
    • /
    • 2015
  • Present guided missiles are equipped with infrared seeker to find the infrared sources radiating from target plane and then chase, which results in an improvement of the hitting success rate when in striking target objects. To interrupt the chases from the guided missile, the target plane spreads the flare, avoiding the missile attracts. Our research is to develop a 2-color infrared identification technique to discern the flare and real thermal source from target plane. Considering flare radiation properties and EM atmosphere transmission rates, two channels were selected, in which main channel (MC) was in a range of 3.7 μm∼4.8 μm and auxiliary channel (AC) in 1.7 μm∼2.3 μm. A 2500K heat source was used for an artificial flare source, while a 570K heat source was utilized for airplane infrared source in experimental testing. Two infrared sensors detectable only at each chanel were employed in order to measure the voltage ratio from two channels, identifying the flare and real target plane via comparison the voltage ratio. Several experimental conditions were imported in order to prove that our proposed 2-color infrared identification technique is very efficient way to discern heat sources from aircraft and flare, demonstrating that our proposed technique is very promising means for our force’s InfraRed Counter Counter Measure (IRCCM) in order to countermeasure opposite force’s InfraRed Counter Measures (IRCM).

Study on the wheel allocation and the wheel momentum off-loading for COMS having asymmetric solar array configuration (비대칭 태양전지판 형상의 천리안위성 휠배치와 휠모멘텀조정에 관한 연구)

  • Park, Young-Woong;Choi, Hong-Taek
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.57-63
    • /
    • 2013
  • The mission of a lot of satellites on geostationary orbit is the communication and/or the broadcasting. These satellites need a big power, so these have a large solar array. Recently, the new satellite for Earth environment monitoring is developing on geostationary orbit. The payload of Earth monitoring satellite requires better thermal condition on detector. Therefore this satellite uses a boom for the attitude stability instead of rejecting one-side solar array as a heat source. The other hand, it uses some momentum wheels being a more momentum capacity to control the large disturbance by solar pressure due to the asymmetric solar array configuration. In this paper, the analysis on the wheel allocation and the wheel off-loading for COMS is summarized and the results are verified by telemetry of COMS. COMS has no boom and a perfectly asymmetric solar array configuration, and it is operating well on geostationary orbit.

Association of Self-Reported Job Stress with Depression and Anxiety (직무스트레스와 우울 및 불안 증상의 연관성)

  • Kim, Yunsin;Kim, Eun-Jin;Lim, Se-Won;Shin, Dong-Won;Oh, Kang-Seob;Shin, Young-Chul
    • Anxiety and mood
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2015
  • Objective : This study investigated the job stress and their association with depression and anxiety among Korean employees. Method : We retrospectively studied 80,842 employees, who receive regular checkups in the Health Screening Center of a one hospital from May, 2012 to April, 2013. A total of 73,975 people were analyzed, who completed a short form of Korean Occupational Stress Scale (KOSS), Center for Epidemiologic Study-Depression (CES-D) and Beck Anxiety Inventory (BAI). Results : Each of the seven subscales of KOSS was categorized into 4 quartile groups. Higher quartile of KOSS was associated with higher CES-D and BAI score an individual reported. The significantly increased odds ratios (ORs) in the higher scoring group compared to the lower scoring group for the effect of job stress on depression and anxiety remained after adjusting for age, sex, marital status, education, income, BMI, and smoking status. Conclusion : These results from a large number of respondents suggested that job stress might be related to depression and anxiety. Future investigations should design a prospective study to understand a causal relationship between job stress and psychiatric symptoms or disorders.

Comparison of the Clinical Features According to the Age of Onset in Panic Disorder (발병연령에 따른 공황장애 임상 양상의 차이)

  • Shin, Eunsook;Ha, Juwon;Kim, Hyung Tae;Lim, Sewon;Shin, Dongwon;Shin, Youngchul;Oh, Kang-Seob
    • Anxiety and mood
    • /
    • v.10 no.2
    • /
    • pp.108-114
    • /
    • 2014
  • Objective : The correlation between age of onset and symptoms/severity of panic disorder has not yet been determined. The aim of this research is to determine the different clinical features of panic disorder according to the age of onset. Methods : Patients diagnosed with panic disorder were placed into two groups according to onset of age. The subjects were checked for 13 different panic symptoms presented in the DSM-IV. The investigation was also executed by severity, the anxiety sensitivity index, the scale for depression and anxiety. Results : The early onset group had significantly higher frequencies than the late onset group in the areas of "choking feeling" and "derealization or paresthesia". It was found that only "choking feeling" was statically significant as a risk factor of early onset panic disorder. Among the objective anxiety scale, the subscale of psychological anxiety was higher in the early onset group compared to the late onset group. Conclusion : "Choking feeling" was the only panic symptom that showed a significant difference in accordance with onset age. Earlier onset patients tend to experience a more frequent "choking feeling," which is related to respiratory symptoms. This could mean that earlier onset patients are more likely to have higher psychological anxiety.

NATURAL CONVECTION IN A TRIANGULAR POOL WITH VOLUMETRIC HEAT GENERATION (삼각형 형상의 풀 내에서 열원에 의한 자연대류 수치해석)

  • Kim, Jong-Tae;Park, Rae-Joon;Kim, Hwan-Yeol;Song, Jin-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.302-310
    • /
    • 2011
  • A fluid in an enclosure can be heated by electric heating, chemical reaction, or fission heat. In order to remove the volumetric heat of the fluid, the walls surrounding the enclosure must be cooled. In this case, a natural convection occurs in the pool of the fluid, and it has a dominant role in heat transfer to the surrounding walls. It can augment the heat transfer rates tens to hundreds times larger than conductive heat transfer. The heat transfer by a natural convection in a regular shape such as a square cavity or semi-circular pool has been studied experimentally and numerically for many years. A pool of an inverted triangular shape with 10 degree inclined bottom walls has a good cooling performance because of enhanced boiling critical heat flux (CHF) compared to horizontal downward surface. The coolability of the pool is determined by comparing the thermal load from the pool and the maximum heat flux removable by cooling mechanism such as radiative or boiling heat transfer on the pool boundaries. In order to evaluate the pool coolability, it is important to correctly expect the thermal load by a natural convection heat transfer of the pool. In this study, turbulence models with modifications for buoyancy effect were validated for unsteady natural convections by volumetric heating. And natural convection in the triangular pool was evaluated by using the models.

  • PDF

A Numerical Study of the Fluid Flow and Heat Transfer Characteristics of the Two-Dimensional Turbulent Impingement Jet with a Confinement Plate (제한면을 가지는 이차원 난류 충돌젯트의 유동 및 열전달 특성의 수치적 연구)

  • 강동진;오원태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1675-1683
    • /
    • 1995
  • A numerical study of the fluid flow and heat transfer characteristics of the two-dimensional impingement jet with a confinement plate has been carried out. The fluid flow was calculated by solving the full Navier-Stokes equation. In doing that, the well known SIMPLER algorithm was used and the trouble making convection term was discretized according to QUICKER scheme. The energy equation was simply solved by using the SOR method. For the Reynolds number of 10000, two channel heights, say 1.5 and 3.0 times the jet exit width, and two thermal boundary conditions constant wall temperature and constant wall heat flux were considered. Discrete heat sources were flush mounted along the impingement plate at a distance of 0, 2, 3, 4, 5, 6, 10, 12, times the jet exit width from the stagnation point. The length of each heat source is 4 times the jet exit width long. The Nusselt number averaged over each heat source was compared with experiment. Comparison shows that both calculations and experiment have the secondary peak of Nusselt number at downstream of stagnation point, even though there is a little quantitative difference in between. The difference is believed due to abscure thermal boundary condition in experiment and also accuracy of turbulence model used. The secondary peak is shown to be caused by rigorous turbulent flow motion generated as the wall jet flow is retarded and developes into the channel flow without flow reversal.

A study on temperature characteristic of the gases supplied to SOFC system by utilizing the ship exhaust gas (선박 배기가스 활용에 따른 SOFC 시스템 공급가스의 온도특성에 관한 연구)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.822-828
    • /
    • 2013
  • Since the operating temperature of Solid Oxide Fuel Cell (SOFC) is high, the heat management of the gases supplied to fuel cell system is important. In this paper, the temperature characteristic of the gases supplied to the anode and the cathode of the fuel cell is studied in case of utilizing the waste heat contained in the ship exhaust gas as a heat source to heat up the fuel, gas and water supplied to a 500kW SOFC system for a ship power. For the fuel cell system proposed in this paper, the temperature of gases supplied to the anode and the cathode was the highest temperature at 963K when the exhaust gas of the fuel cell was utilized as the heat source for gases supplied to fuel cell system instead of utilizing the ship exhaust gas. In addition, the engine power did not effect on the temperature of gases supplied to the fuel cell stack.

The Study on Weldability of Boron Steel and Hot-Stamped Steel by Using Laser Heat Source (II) - Laser Weldability of Hot Stamping Steel with Ultra-High Strength - (레이저 열원을 이용한 보론강 및 핫스탬핑강의 용접특성에 관한 연구 (II) - 초고강도 핫스탬핑강의 레이저 용접특성 -)

  • Kim, Jong Do;Choi, So Young;Park, In Duck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1373-1377
    • /
    • 2014
  • Hot-stamping is a method of obtaining ultrahigh-strength steel by simultaneously forming and cooling boron steel in a press die after it has been heated at $900^{\circ}C$ or above. After heat treatment, boron steel has a strength of 1500 MPa or more. This material ensures a high level of quality because it overcomes the spring-back phenomenon, which is a problem associated with high-strength steel materials, and the degree of dimensional precision is improved by 90 or more because of the good formability compared with existing types of steel. In this study, the welding characteristics were identified through the butt and lap welding of hot-stamped steel using a disk laser. Full penetration was obtained at a faster speed with butt welding compared to lap welding, and a white band was observed in every specimen.

Capability Assessment on Meteorological Technology - Comparative Study of Technological Prowess on Korea, U.S., and Japan - (국가 기상기술력 수준 평가 - 한국, 미국, 일본을 대상으로 한 비교 연구 -)

  • Kim, Se-Won;Park, Gil-Un;Cho, Changbum;Lee, Young-Gon;Yim, Deok-Bin
    • Atmosphere
    • /
    • v.21 no.3
    • /
    • pp.319-336
    • /
    • 2011
  • The objective of this study was to assess the meteorological capability of Korea by comparing with that of the U.S. and Japan as of 2010. The research was conducted based on various indices and surveys, and quantified the results using the Gordon's scoring model. The index assessment used 11 items derived from 9 segments - surface observation, advanced observation and observations quality in the observation field; data assimilation, numerical model and infrastructure in the data processing field; forecast accuracy in the forecast field; climate prediction and climate change in the climate field - in this research, we classified the meteorological technology into four fields. In the survey assessment, another 10 items in addition to the above 11 ones (total 21 items) were used. In the field of climate, Korea was found to lag far behind the U.S. (96.5p) and Japan (90.5p) with 77.6 points out of 100, which is 18.9 and 12.9 points lower than them respectively. On the other hand, Korea showed the narrowest gap with Japan (95.3p) and the U.S. (94.2) in the forecasting field, recording 90.3 points. Particularly, in surface observation, infrastructure and forecast accuracy segment, Korea was on a par with the U.S. and Japan, boasting 100.5 percent compared to their counterparts. However, in advanced observation, data quality and climate change segment, Korea was only at the level of 81.5 percent compared to that of the U.S. and Japan. All in all, the technological prowess of Korea, scoring 84.6 points, stood at 89.7 percent of that of the U.S. (94.3p) and 91.9 percent of Japan (92.1p).