• Title/Summary/Keyword: 說苑

Search Result 1,845, Processing Time 0.028 seconds

Performance Estimation of Protector for 154 kV Underground Cable (154kV 지중 케이블 보호장치의 성능평가)

  • Cho, H.G.;Lee, J.H.;Han, S.W.;Kim, S.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.127-131
    • /
    • 2002
  • The surge protector is crucial power apparatus to guarantee the safe operation of power transmission of underground cable which can effectively restrain the overvoltage and inductive lightning stroke in power system. The surge protector is crucial power apparatus to guarantee the safe operation of power transmission of underground cable which can effectively restrain the overvoltage and inductive lightning stroke in power system. This paper described the results of a study on the performance for surge protector for underground cable. And, the performance of surge protector was evaluated through such as measurement of the reference voltage, residual voltage and impulse current etc. In results of surge protector, reference and residual voltage of ZnO element is 4.75 kV, 9.86 kV respectively. Also, In the impulse current test, thermal properties are good, despite of that polymeric housing of surge protector has thick structure. Therefore the developed surge protector is thought to apply for underground cable.

  • PDF

Design and Simulation Technologies of Flat Transformer with High Power Current (대전류 출력형 Flat Transformer 설계 및 해석 기술)

  • Han, Se-Won;Cho, Han-Goo;Woo, Bung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.15-17
    • /
    • 2002
  • Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

Heat Recovery System from Chamber of Agricual Products Dryer (농산물건조기의 배풍열 재이용 기술에 관한 연구)

  • Paek, Y.;Kim, Y.J.;Kang, G.C.;Ryou, Y.S.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.241-246
    • /
    • 2002
  • 본 연구는 농산물을 건조할 때 배풍구로 버려지는 열을 회수하여 건조열원으로 재이용할 수 있는 배풍열 회수장치를 개발하여 연료절감 및 열회수장치의 성능을 분석한 연구 결과 다음과 같은 결론을 얻었다. 가. 농산물건조기의 열수지를 분석한 결과 투입열량을 100%로 하였을 경우, 배기열은 13.2%, 배풍역량 77.7%, 관류열량은 9.1%로 나타났다. 나. 고추를 건조시 배풍구입구온도가 55-6$0^{\circ}C$일 때 배풍구 출구온도 41-43$^{\circ}C$, 일때 흡입구 입구온도는 25-28$^{\circ}C$, 흡입구 출구온도는 41-43$^{\circ}C$로 나타나 건조실로 41-43$^{\circ}C$의 높은 온도를 투입할 수 있었다. 다. 배풍열 량이 단위 시간당 4700kca1에서 6000kca1로 증가할 때, 흡입 열량은 2200kca1에서 3000kca1로 나타났다. 라. 고추의 초기함수율이 80%에서 15%까지 떨어지는데 관행건조는 약 27시간이 경과했으며, 배풍연회수건조를 할 경우는 약 24시간이 경과했으며 그 결과 배풍열 회수건조가 약 3시간정도 소요시간이 단축되었음을 알 수 있었음. 마. 배풍열 회수장치를 사용하여 농산물건조기 투입량의 47%, 배풍열량의 64%의 열량을 회수할 수 있었다. 바. 배풍열 회수 농산물건조기 성능시험 결과 고추 100kg 건조시 연료소모량은 43%, 건조 소요비용은 21% 감소시킬 수 있었다.

  • PDF

An analysis of Ultrasound signals using wavelet transform (II) (Wavelets 변환을 이용한 초음파 신호의 분석 (II))

  • Hong, S.W.;Kim, D.J.;Choi, H.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.583-586
    • /
    • 1997
  • In this study, we proposed an application of wavelet transform or analysis of ultrasound echo signals to improve troubles of convenianced methods such as SDM, SSM. We examined method using wavelet transform to prove again our proposal which we have proposed prior time. At first, we made phantoms by adding 0.01, 0.015, 0.02, 0.025, 0.03, 0.035, 0.04, 0.045, 0.05($g/cm^3$) on constant quantity of distilled water and agar, and collected echo signals. We used SDM(spectral difference method) and WTM(wavelet transform method) as signal processing method. To compare with WTM, SDM was used. In WTM, we selected detail signals of level 3 of Daubechies 16, and got derivative, calculated area of it. Next, we calculated slopes. In SDM, it was 0.0308 and in WTM, it was 0.5248. As a result, we knew that we could know that the values using WTM showed more detailed than those using SDM. So we could concluded wavelet transform is very useful and powerful in ultrasound tissue characterization.

  • PDF

Characteristics of Decrease Effect in Fouling on Plate Heat Exchanger Using Air Bubble (버블을 이용한 플레이트 열교환기의 파울링 저감특성)

  • Baek, S.M.;Choi, W.J.;Yoon, J.I.;Seol, W.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.22-26
    • /
    • 2010
  • Generally, it is a method to remove the fouling cleaning the plate heat exchanger with chemicals or polishing with a brush or cloth after stopping the equipment and disassembling heat exchanger. However, the equipment must be stopped and taken apart when using this method, which causes an unnecessary work to assemble again after cleaning it. In this study, it has developed and tested the equipment which can automatically clean the fouling on plate heat exchanger at regular intervals with air bubbles. It indicated that the overall heat transfer coefficient had decreased without significant differences similar to that calculated without air bubbles until after 72 hours when making air bubbles to remove fouling ingredient on the surface of heat transfer area every 10 minutes per 2 hours. However, it showed that there was a 10% higher of heat transfer effect compared to the case without air bubbles of after 192 hours.

The Effect of Pulsed Ultrasound on Skin Inflammatory Reaction Induced by Ultraviolet Irradiation (자외선 조사로 유발된 피부 염증성 반응에 맥동성 초음파가 미치는 영향)

  • Lee, Jeong-Woo;Park, Su-Ji;Yoon, Se-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.4
    • /
    • pp.53-58
    • /
    • 2011
  • Purpose: This study aims to examine the effects of pulsed ultrasound on skin inflammatory reaction induced by ultraviolet irradiation. Methods: Twenty subjects were selected for this study. Inflammatory reaction was induced by ultraviolet irradiation in two areas of the lumbar region of the subjects. Pulsed ultrasound (3 MHz) was applied to one of the two areas of inflammatory reaction at a pulse ratio of 1:4, intensity of $0.5W/cm^2$, once a day for 5 min, and pulsed ultrasound was not applied to the other area. Wound color (chromatic red), luminance (gray) and wound contraction (area) were measured using digital imaging processing method. Results: There was a significant difference in wound color (chromatic red) in the interaction between time and area. There was a significant difference in luminance in the interaction between time and area. There was a significant difference in wound contraction between the two areas. Conclusion: These results indicate that pulsed ultrasound increased the wound contraction rate and reduced the inflammatory reaction activity such as erythema induced by ultraviolet irradiation.

The Effect of Aquatic Rotation Exercise on Balance Maintenance (수중회전조절운동이 20대 여성의 균형유지에 미치는 영향)

  • Choi, Sug-Ju;Yoon, Se-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.27-32
    • /
    • 2010
  • Purpose: This study was designed to examine the effects of a Halliwick rotation program on improving balance. Methods: Nine healthy females were randomly assigned to a Halliwick rotation program training as an aquatic group (n=9, age=$22.5{\pm}1.3$ years) or to a control group. The aquatic group trained using a Halliwick rotation program (3 times/week, 30 min/day) for 6 weeks. Balance was measured according to stance position: Hard Plate Open Eyes (HOE), Hard Plate Close Eyes (HCE), Soft Plate Open Eyes (SOE) and Soft Plate Close Eyes (SCE). This was done before the training and 3 and 6 weeks after the training. The data were analyzed with the SPSS Win 12.0 program using repeated measure ANOVA. Results: There were significant training-induced differences in SOE and POE (p<0.05), and in SCE and PCE (p<0.05) by Toe pad. There were significant training-induced differences in SOE and POE (p<0.05) by Heel pad after the aquatic rotation exercise program. Conclusion: The Halliwick rotation program can improve balance.

A Study on Performance and Reactor Behavior of Chemical Refrigerator (화학식 냉동기의 성능 및 반응기 거동에 관한 연구)

  • Park, Seung-Hoon;Lee, Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.87-95
    • /
    • 1997
  • A chemical heat pump based on the reversible reactions between metal chlorides and ammonia gas is attractive alternative to compression system and liquid absorption systems in cooling and refrigerating fields. The advantages of chemical heat pump are no regulatory constants due to CFC refrigerants, utilization of gas, industrial waste heat, electricity, fuel oil etc. as heat sources and wide applications to energy storage system, large-scale energy managements for industrial process. The scale-up of chemical heat pump from laboratory prototype to pilot plants necessitates the interpretation of system performance and evaluation of dynamic behavior in the chemical reactor. This study contains the prediction of performance of chemical refrigerator according to operating condition, the dynamic simulations through reactor modelling, which is used for the calculation of reactive medium temperature and the conversion variation with reactor cooling temperature, and the effect survey of block parameters on the power of refrigerator.

  • PDF

Study of $MgB_2$ Films Grown on Various Impurity Layers by using HPCVD Method (혼성물리화학기상 증착법으로 여러가지 불순물층 위에 제조한 $MgB_2$ 박막에 대한 연구)

  • Park, S.W.;Seong, W.K.;Jung, Soon-Gil;Kang, W.N.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.35-39
    • /
    • 2008
  • By using the hybrid physical-chemical vapor deposition (HPCVD) technique, we have fabricated $MgB_2$ thick films on $Al_{2}O_3$ substrates with various impurity layers of Ni, Ti, and SiC. We have found a significant enhancement of the critical current density ($J_c$) for $MgB_2$ films grown on impurity layered substrates, indicating that additional impurity layers were provided as possible pinning sites by chemical doping in $MgB_2$ films. All samples doped by Ni, Ti, and SiC were observed to have high superconducting transition temperatures of 39 - 41 K. The $J_c$ of $MgB_2$ films grown on SiC impurity layered substrates showed three times higher than that of undoped films at high magnetic fields above 1 T.

  • PDF

Integrated Medicine Therapy for a Patient with a Diabetic Foot Infection (한양방 병행치료로 호전된 당뇨병성 족부감염 환자 증례보고)

  • Lee, Jae-seob;Kim, Sae-won;Baek, Kyung-min;Jan, Woo-seok
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.2
    • /
    • pp.207-216
    • /
    • 2015
  • Objectives: The purpose of this study is to report the clinical application of acupuncture, herbal medication, and antibiotic treatment to a patient with a diabetic foot infection. Methods: We treated the patient-who had ulcerations of the 1st, 2nd, and 4th toes and osteomyelitis on the right 1st and 2nd toes-with acupuncture, herbal medication, and antibiotics. We measured the state of this case by changes in his MRI signal and ulceration of his toes. Results: After treatment, the MRI signal indicated that the osteomyelitis had disappeared and the ulceration was diminished. Conclusions: A combination of acupuncture, herbal medication, and antibiotic treatment is effective for treatment of ulceration and osteomyelitis caused by diabetic foot infection.