• Title/Summary/Keyword: 換氣

Search Result 4,213, Processing Time 0.04 seconds

Effects of Modified Installation Methods of Roof Ventilation Devices in the Single-span Plastic Greenhouses on Yield and Fruit Quality of Oriental Melon (단동 비닐하우스의 지붕 환기장치 설치방법 개선이 참외생육 및 과실수량에 미치는 영향)

  • Yeo, Kyung-Hwan;Yu, In-Ho;Choi, Gyeong Lee;Lee, Seong-Chan;Lee, Jae-Han;Park, Kyoungs Sub;Lee, Jung-Sup;Bekhzod, Khoshimkhujaev
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.334-342
    • /
    • 2016
  • In order to evaluate the modified installation methods of roof ventilation devices, derived from the previous experiment ('investigation into the optimum capacity of roof ventilation devices and their deployment'), the conventional and modified (improved) roof ventilation systems were installed in the single-span plastic greenhouse for growing oriental melons. The roof vents ($60{\varphi}$) and roof fans (maximum air capacity of $38m^3/min$) were installed in the spacing of 15m (FT, modified 'side vent+roof fan' ventilation) and 6m (TT, modified 'side vent+roof vent' ventilation) respectively on the roof of greenhouses for the modified roof ventilation treatments, and 20m (FC, conventional 'side vent+roof fan' ventilation) and 8m (TC, conventional 'side vent+roof vent' ventilation) for the conventional ones. The stem diameter, leaf blade lengh, petiole length, and leaf width were lower in the FT and TT treatments than those in the conventional treatments, FC and TC. Although the fruit weight and total yields were slightly lower in the FT and TT treatments, the marketable fruit ratio (%) were higher, as a result of increased fruiting ratio (%) in these treatments, than those of FC and TC. The marketable yields (kg/10a) in the FT and TT treatments were 8,391 kg/10a and 7,283 kg/10a, which were respectively 661 kg/10a and 487 kg/10a higher than those in the treatments of FC and TC. The modified installation methods of roof fan resulted in production of more female flowers and lower fruit drop ratio (%) compared to conventional meathods. In the treatment of the conventional ventilation with roof vent, the fruit weight, fruit length & width, and flesh thickness were higher than in other treatments, but there were no significant differences in the fruit width and flesh thickness among the treatments.

Roof Ventilation Structures and Ridge Vent Effect for Single Span Greenhouses of Arch Shape (아치형 단동온실의 지붕환기구조 및 천창효과)

  • Nam, Sang-Woon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.99-107
    • /
    • 2001
  • It is difficult to install a ventilation window on the roof of single span greenhouses of arch shape. Investigation on the roof ventilation structures for those greenhouses was conducted. In small greenhouses with spans of 5 to 8 m, circular or chimney type ridge vents made of plastic were employed. In large greenhouses with spans of 12 to 18 m, even span roll-up ridge vents made of steel pipe were employed. The effect of roof ventilation was evaluated by comparative experiments between greenhouse installing ridge vents and having controlled side vents only. Roof ventilation contributed greatly to restraint of temperature rise and maintenance of uniform temperature distribution in greenhouses. And ventilation efficiency was analyzed by experiments on the opening and closing operation of the ridge and side vent. There were no temperature differences according to opening and closing sequence of ventilation window. But for greenhouse temperature control by ventilation, it is desirable to open side vents after ridge vents and to close ridge vents after side vents.

  • PDF

16×16 HEVC Inverse Core Transform Architecture Using Multiplier Reuse (곱셈기를 재사용하는 16×16 HEVC 코어 역변환기 설계)

  • Lee, Jong-Bae;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.378-384
    • /
    • 2015
  • In conventional HEVC inverse core transform architectures, extra $n{\times}n$ inverse transform block is added to $2n{\times}2n$ inverse transform block, and it operates as one $2n{\times}2n$ inverse transform block or two $n{\times}n$ inverse transform blocks. Thus, same number of pixels are processed in the same time, but it suffers from increased hardware size due to extra $n{\times}n$ inverse transform block. To avoid this problem, a novel $8{\times}8$ HEVC inverse core transform architecture was proposed to eliminate extra $4{\times}4$ inverse transform block based on multiplier reuse. This paper extends this approach and proposes a novel HEVC $16{\times}16$ inverse core transform architecture. Its frame processing time is same in $4{\times}4$, $8{\times}8$, and $16{\times}16$ inverse core transforms, and reduces gate counts by 13%.

An Experimental Study on Ventilation of Connection Passage and Elevator Hall of Underground Parking in the Apartment Houses (공동주택의 지하주차장 연결통로 및 엘리베이터 홀의 환기에 관한 실험적 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1523-1528
    • /
    • 2008
  • In this study, the ventilation system of connection passage and elevator hall of underground parking lot in apartment houses is investigated to extract the data for the installation and the application by the experimentation. In case of the elevator hall, actual air exchange rate is predicted fivefold higher than air exchange rate by infiltration and exfiltration. Ventilation system is installed good by supply air and return air. As the next best thing, it is installed by supply air because of IAQ control. The temperature of connection passage and elevator hall uniformly with $7{\sim}8^{\circ}C$, is maintained even if the operating condition of ventilation system is different. Therefore, the installation of the preheater, which is installed at the inlet of ventilation system for the cold draft in winter, is not essential in southern area of Korea.

Analysis of Ventilation Impact in Multi-Family Residential Building Utilizing TOPSIS Method (다기준 의사결정방법을 이용한 공동주택 내 환기장치 종류별 효과분석)

  • Park, Kyung-Yong;Kim, Gil-Tae;Kim, Tae-Min;Ji, Won-Gil;Kwag, Byung-Chang
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.107-113
    • /
    • 2022
  • With increasing airtight building construction aimed at reducing energy consumption, indoor relative humidity is increasing which can lead to condensation and moisture damage in multi-family residential buildings. This has led to increased implementation of mechanical ventilation to control indoor moisture. However mechanical ventilation systems consume additional energy and generate noise. As this leads to occupant discomfort, it is necessary to select a ventilation system that addresses the energy and noise issues. This research measured the ventilation performance, energy consumption, and noise level of mechanical ventilation devices in multi-family residential buildings. TOPSIS, a multi-criteria decision making technique was used to determine appropriate ventilation strategies in addition to occupant ventilation system operation preference.

보일러사도 환기시장 간다

  • Korea Boiler Engineering Association
    • 보일러설비
    • /
    • no.3 s.158
    • /
    • pp.144-147
    • /
    • 2007
  • 원자재 가격 상승과 달러화 약세 등의 영향으로 내수시장과 수출시장 모두에서 어려움을 겪고 있는 보일러 제조업체들이 일제히 환기시장으로 눈을 돌리면서 시장 쟁탈전이 뜨거워 지고 있다. 실내공기 오염악화를 이유로 공동주택과 관련 시설 등에 대한 환기시스템 설치를 의무화하는 '다중이용시설 실내공기질 관리법'이 지난해 발효되면서 주택 환기시스템 관련 수요는 매년 확대될것으로 전망되고 있기 때문이다. 실제로 환기시장 규모는 2004년 500억원대에서 2005년1000억원 규모로 성장했고 지난해에는 2200억원대를 기록했다. 업계관계자들은 올해 환기시장의 규모를 약 3500억원대로 예상하고 있고 내년에는 5500억원대까지 성장할 것으로 전망하고 있다. 이에 따라 이 시장에 진출한 보일러사들은 일제히 신제품을 발표하고 나섰고 최근에는 경동나비엔과 대성쎌틱이 새롭게 시장에 진입한 상태다. 주요 보일러사들이 출시한 환기시스템의 특장점과 마케팅 방향등에 대해 알아봤다.

  • PDF

브로일러 수익성은 사육환경이 결정한다

  • 유일웅
    • KOREAN POULTRY JOURNAL
    • /
    • v.24 no.3 s.269
    • /
    • pp.140-142
    • /
    • 1992
  • 브로일러를 생산하는데 있어서 환기가 매우 중요한 요인의 하나가 되는 것은 말 할 필요도 없다. 그러나 브로일러 농장의 실태를 볼 때 환기조작이 적절하지 않은 예가 있는 것으로 보인다. 중요한 것은 기상조건의 변화를 예측해 보는 것이 필요한데 이는 환기가 브로일러의 발육과 건강을 위해 이상적인 환경을 만들어 내는데 중요하기 때문이다. 사내환경이 부적절 할 때 브로일러의 발육저하가 발생되며 성장률도 나빠지고 사료효율도 저하된다. 또 깃털상태도 좋지 않아 상품의 질이 떨어져 결국 수익저하로 이어진다. 현재 국내에서 사용하고 있는 브로일러 계사는 환기가 좋지않은 경우가 많이 보이는데 커텐을 사용할 때 자연환기를 이용하는 계사에서는 주의깊은 점검을 필요로 하고 결국은 보다 안정된 환경을 공급해 주는 것이 필요하다. 현재 양계장에서 활용하고 있는 강제환기법은 기본적으로 팬을 이용해 계사내의 공기유동을 조정하는 것으로 되어 있으나 강제환기에는 계사내에 공기를 끌어들이는 방식과 계사내의 공기를 외부로 배출시켜 나가는 방식이 있다.

  • PDF

Korean Morphological Analyzer and POS Tagger Just Using Finite-State Transducers (유한상태변환기만을 이용한 한국어 형태소 분석 및 품사 태깅)

  • Park, Won-Byeong;Kim, Jae-Hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.165-168
    • /
    • 2006
  • 이 논문은 유한상태변환기만을 이용하여 한국어 형태소 분석 및 품사 태깅 시스템을 제안한다. 기존의 한국어 형태소 분석 시스템들은 규칙기반 형태소 분석기가 주를 이루고 한국어 품사 태깅 시스템은 은닉마르코프 모델 기반 품사 태깅이 주를 이루었다. 한국어 형태소 분석의 경우 유한상태변환기를 이용한 경우도 있었으나, 이 방법은 변환기를 작성하기 위한 규칙을 수작업으로 구축해야 하며, 그 규칙에 따라서 사전이 작성되어야 한다. 이 논문에서는 품사 태깅 말뭉치를 이용해서 유한상태변환기에서 필요한 모든 변환 규칙을 자동으로 추출한다. 이런 방법으로 네 종류의 변환기, 즉, 자소분리변환기, 단어분리변환기, 단어형성변환기, 품사결정변환기를 자동으로 구축한다. 구축된 변환기들은 결합연산(composition operation)을 이용하여 하나의 유한상태변환기를 구성하여 한국어 형태소 분석과 동시에 한국어 품사 태깅을 수행한다. 이 방법은 하나의 유한상태변환기만을 이용하기 때문에 복잡도는 선형시간(linear complexity)을 가지면, 형태소 분석기와 품사 태깅 시스템을 매우 짧은 시간 내에 개발 할 수 있었다.

  • PDF

Evaluation of Changes in Radon Levels in Educational Research Facilities by Number of Ventilation and Time (환기횟수 및 환기시간에 따른 교육연구시설 라돈 수치변화 평가)

  • Shin, Yoon-Seok;An, Jae-Seung;Kim, Seong-Bin;Park, Min-Young
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.335-336
    • /
    • 2023
  • 최근 환경에 대한 관심이 지속적으로 증가함에 따라 실내 공기질에 대한 관심 역시 증폭되었다. 이에 따라 실내 공기질을 결정 짓고 흡연에 이어 폐암 사망률이 높은 라돈에 대한 관심 역시 증가하였다. 따라서 본 연구에서는 실내 라돈가스의 농도를 낮추기 위한 방법을 찾기 위해 RADON EYE RD200을 이용하여 교육연구시설에서의 세 강의동을 대상으로 라돈 방출량을 측정하고, 환기를 통해 라돈의 감소량을 측정한다. 세 강의동 모두 현재 기준치인 148 Bq/m3을 초과하는 수치를 기록하였고, 강의실을 10분간 환기한 결과 1회 환기 시 평균 77 Bq/m3만큼 감소하였고, 2회 환기 시 평균 56 Bq/m3만큼 감소하였다. 본 연구를 통해 라돈의 실태 및 위험성을 인지하고 라돈에 관련된 시설물 지침 및 환기를 강조하는 방안에 대한 마련이 필요하다고 판단된다.

  • PDF

Measurement of Ventilatory Threshold in the Patients with Chronic Airway Obstruction (만성기도폐쇄를 보이는 환자에서 환기성역치 측정)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Keun-Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.309-320
    • /
    • 1997
  • Background : There are many suggested methods for the indirect determination of anaerobic threshold(AT) using the changes of ventilatory parameters in response to ventilatory load accompanying the increase of blood lactic acid level during exercise and the threshold derived from them is called ventilatory threshold(VT). They include ventilatory equivalent method(VEM), End-tidal $PO_2$ method($PETO_2$). V-slope method(VSM), and respiratory quotient method(RQ). But in the patients with chronic airway obstruction(CAO), the AT determined by ventilatory methods may not reflect true AT because the patients with CAO show inadequate ventilatory response to the increase of blood lactic acid level during excercise. Methods : For the investigation of detection rate and reliability of above four VT determination methods in the patients with CAO, we performed the symptom-limited and maximal incremental exercise test in 17 patients with CAO and 12 normal controls. The incremental workload was 10 W /min in CAO group and 25 W/min in control group. The reliability of VT in each group was investigated by the calculation of Spearman correlation coefficient. Results : The detection rates of VT were 100% by RQ, 91.7% by both VEM and $POETO_2$, and 83.3% by VSM in normal control group, while 94.1% by RQ, 64.7% by VEM and $PETO_2$, and 83.3% by VSM in CAO group. Good correlations were noted among VEM, $POETO_2$, and VSM except RQ in normal control group. But there was no significant correlation except between VEM and $PETO_2$ in CAO group. Conclusions : RQ is very sensitive but crude and VEM is near similar to $PETO_2$. The clinical usefulness of VT determined by ventilatory method might be limited in patients with severe CAO.

  • PDF