• Title/Summary/Keyword: @CC

Search Result 3,315, Processing Time 0.032 seconds

Single mode yield analysis of complex-coupled DFB lasers above threshold for various coupling coefficient ratios and facet reflectivity combinations (문턱 전류 이상에서 Complex-Coupled DFB 레이저 다이오드의 여러 가지 결합 계수 비와 양 단면 반사율 조합에 따른 단일 모드 수율 해석)

  • 김부균;김상택;전재두
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.5
    • /
    • pp.521-529
    • /
    • 2003
  • For complex-coupled (CC) DFB lasers, we found that there might be little correlation between the single mode yields at threshold and above threshold. At threshold, the single mode yield considering f number of in-phase (IP) CC DFB lasers is the same as that of anti-phase (AP) CC DFB lasers. However, the single mode yield as a function of injection current above threshold of IP CC DFB lasers is much different from that of AP CC DFB lasers. In the case of IP CC DFB lasers, the single mode yield increases as the coupling coefficient ratio (CR) increases, while, in the case of AP CC DFB lasers, the single mode yield decreases rapidly regardless of CR as the injection current increases. In the case of AR-HR combinations, the effect of AR ref1ectivity on the single mode yield increases as the coupling strength decreases. As the coupling strength decreases, the CR at which the increase rate of the single mode yield starts to decrease, increases, and the maximum single mode yield increases. Single mode yields of AR-HR and AR-AR combinations are larger than those of AR-CL and CL-CL combinations.

Airborne Asbestos Concentrations of Dental Laboratories in One Metropolitan City (치과기공소의 공기 중 석면농도 분포에 관한 연구 -일개 광역시를 중심으로-)

  • Jung, In-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • This study was performed to investigate the problems of using asbestos for dental technicians. Samples for analysing were sampled by personal sampler in 40 sampling points of 10 dental laboratories in Daegu city from December 2010 to January 2011 and counted with phase contrast microscopy. The results were as follows: 1. Asbestos concentration(geometric mean) of 40 sampling points in 10 dental laboratories was 0.0061 f/cc and it was under recommended industrial and indoor air standard, but the concentration of asbestos in only two dental laboratories was over indoor recommended standard. 2. The concentration of asbestos in processing room and burnout room was 0.0099 f/cc and 0.0037 f/cc, respectively. 3. The mean concentration(GM) of asbestos by kinds of casting ring liners was 0.0159 f/cc in dental laboratories using industrial asbestos, 0.0104 f/cc in them using asbestos containing ring liners, and 0.0026 f/cc in them using non-asbestos ring liners. Casting ring liners using in dental laboratories should be substituted with non-asbestos liners, because most of dental laboratories were using asbestos containing ring liners and a few of them showed higher concentration than recommended standard.

No Association of the TGF-β1 29T/C Polymorphism with Breast Cancer Risk in Caucasian and Asian Populations: Evidence from a Meta-Analysis Involving 55, 841 Subjects

  • Alqumber, Mohammed A.A.;Dar, Sajad Ahmad;Haque, Shafiul;Wahid, Mohd;Singh, Rohit;Akhter, Naseem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8725-8734
    • /
    • 2014
  • The transforming growth factor-${\beta}1$ (TGF-${\beta}1$) gene 29 T/C polymorphism is thought to be associated with breast cancer risk. However, reports are largely conflicting and underpowered. We therefore conducted a meta-analysis of all available case-control studies relating the TGF-${\beta}1$ 29T/C polymorphism to the risk of developing breast cancer by including a total of 31 articles involving 24,021 cases and 31,820 controls. Pooled ORs were generated for the allele contrasts, with additive genetic, dominant genetic and recessive genetic models. Subgroup analysis was also performed by ethnicity for the TGF-${\beta}1$ 29T/C polymorphism. No association was found in the overall analysis (C vs T: OR=1.028, 95% CI=0.949-1.114, p-value 0.500; CC vs TC: OR= 1.022, 95% CI=0.963-1.085, p-value 0.478; CC vs TT: OR= 1.054, 95% CI=0.898-1.236, p-value 0.522; CC vs TT+ TC: OR= 1.031, 95% CI=0.946-1.124, p-value 0.482; TT vs CC+TC: OR= 0.945, 95% CI=0.827-1.080, p-value 0.403). Similarly, in the subgroup analysis by ethnicity, no association was found in Caucasian (C vs T: OR= 1.041, 95% CI=0.932-1.162, p-value 0.475; CC vs TC: OR= 1.031, 95% CI=0.951-1.118, p-value 0.464; CC vs TT: OR= 1.081, 95% CI=0.865-1.351, p-value 0.493; CC vs TT+TC: OR= 1.047, 95% CI=0.929-1.180, p-value 0.453; TT vs CC+TC: OR= 0.929, 95% CI=0.775-1.114, p-value 0.429;) and Asian populations (C vs T: OR= 1.004, 95% CI=0.908-1.111, p-value 0.931; CC vs TC: OR= 0.991, 95% CI=0.896-1.097, p-value 0.865; CC vs TT: OR= 1.015, 95% CI=0.848-1.214, p-value 0.871; CC vs TT+TC: OR= 1.000, 95% CI=0.909-1.101, p-value 0.994; TT vs CC+TC: OR= 0.967, 95% CI=0.808-1.159, p-value 0.720;). No evidence of publication bias was detected during the analysis. No significant association with breast cancer risk was demonstrated overall or on subgroup (Caucasian and Asian) analysis. It can be concluded that TGF-${\beta}1$ 29T/C polymorphism does not play a role in breast cancer susceptibility in overall or ethnicity-specific manner.

Digital Data Communication System for Mobile Network System Using CC1020 Chip (CC1020 Chip을 사용한 모바일 네트워크를 위한 디지털 데이터 통신 시스템)

  • Lim, Hyun-Jin;So, Heung-Kuk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.58-62
    • /
    • 2007
  • Digital communication is important for reliability and mobilization of the multi-channel communication systems. Transmitting and receiving data for the mobilization should be possible in anywhere and in anytime. And this system must be designed light weight small size and low power. One are essential technology for implementing the mobile wireless communication system on the age of ubiquotos. Requirements in constructing such communication field are followings. At first data transmitting and receiving should be carried out by a simple command. Second, the device should be designed as hand-hold type and low power consumption. Third, data communication should be reliable. As one of examples, car to car system which is popular in the market is introduced here, All traffic information in highway is transmitted from one car to another by using this system which can prevent possible traffic accident. This paper shows the design of a digital data communication system with CC1020 chip. This CC1020 makes easy frequency selection and easy switch from the transmit mode to the receive mode by simple setting of a memory register in the chip. The transmit power of this system is designed 10dBm and its communication range is about 100m. The power supplied this system is 3V considered as low power. The sleep mode can be easily entered during transmit mode or receive mode. We shows the program algorithm of CC1020 and interface circuit between MCU and CC1020. We shows the Photo of the CC1020 Module and Atmega128 Module.. We analysed the receiver rate with this system.

  • PDF

A Study on the Protocol Conformance Testing of DSM-CC U-U Interfaces (DSM-CC U-U 인터페이스 프로토콜 적합성시험 연구)

  • 서칠성;김규형;강성원
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.591-593
    • /
    • 1998
  • DSM-CC U-U(User-to-User) 인터페이스는 다양한 광대역 멀티미디어 서비스 환경에서 멀티미디어 응용들을 제공하기 위하야 요구되는 동작들을 정의한 개방형 프로토콜이다. 본 연구에서는 DSM-CC U-U 인터페이스를 시험하기 위한 적합성 시험방법을 제시하고, 선택된 적합성 시험구조를 위한 접합성 추상시험항목들(Abstract Test Cases)을 도출한다.

  • PDF

The Design of Diagnostic Framewok for Multi-Computer CC-NUMA Systems (다중 컴퓨터 CC-NUMA 시스템의 진단 프레임웍 설계)

  • 김주만;정낙주;정태일
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10c
    • /
    • pp.84-86
    • /
    • 1999
  • 본 논문은 CC-NUMA 시스템과 같은 다중 컴퓨터 시스템에서 분산된 자원에 대한 효율적인 관리 및 진단을 위한 프레임웍의 설계에 대해 기술한다. CC-NUMA 시스템이란 고성능 상호 연결 망에 결합되어 하드웨어 방식으로 메모리 일관성을 제공하는 다중 컴퓨터이다. 이러한 시스템은 주로 엔터프라이즈 서버용으로 사용되기 때문에 TCO(Total Cost of Ownership)에 근거한 관리 및 지난 기능이 필수적으로 요구된다. 본 연구는 고성능 멀티미디어 서버(MX-Server)의 진단 및 관리 기능으로 제공되는 SDC(Server Diagnositc Card)의 하드웨어 및 소프트웨어 구조 설계 시 고려사항에 대하여 논하였다.

  • PDF

CC-based security-software quality evaluation (CC 기반 보안 S/W 품질평가)

  • Lee, Yong-Ho;Shin, Seok-Kyoo;Cho, In-Sub
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.221-224
    • /
    • 2004
  • 보안 S/W의 보안성 평가기준(CC; Common Criteria)은 국제 표준 ISO/IEC 15408로 제정되었고, 시제품에 대한 보안기능요구사항과 보증요구사항을 표준화된 방법으로 표현하고 있다. 보안 S/W의 보안성은 중요하나 그 품질 또한 간과되어서는 안 된다. 이에, 본 논문에서는 CC에서 기술하고 있는 보안기능에 대한 S/W 품질평가기준에 대해 연구하였다.

  • PDF

Comparative Evaluation of Two-dimensional Radiography and Three Dimensional Computed Tomography Based Dose-volume Parameters for High-dose-rate Intracavitary Brachytherapy of Cervical Cancer: A Prospective Study

  • Madan, Renu;Pathy, Sushmita;Subramani, Vellaiyan;Sharma, Seema;Mohanti, Bidhu Kalyan;Chander, Subhash;Thulkar, Sanjay;Kumar, Lalit;Dadhwal, Vatsla
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4717-4721
    • /
    • 2014
  • Background: Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Materials and Methods: Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned. All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Results: Mean doses received by 100% and 90% of the target volume were $4.24{\pm}0.63$ and $4.9{\pm}0.56$ Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were $2.88{\pm}0.72$, $2.5{\pm}0.65$ and $2.2{\pm}0.57$ times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were $1.80{\pm}0.5$, $1.48{\pm}0.41$ and $1.35{\pm}0.37$ times higher than ICRU rectal reference point. Conclusions: Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.

The Realization of RFID Tag Data Communication System Using CC1020 (CC1020을 이용한 RFID Tag 데이터 통신 시스템 구현)

  • Jo, Heung-Kuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.833-838
    • /
    • 2011
  • RFID system in manufacturing industry is used to collect, categorize, and process the data of products. To install RFID system for a large factory, a large amount of wired data communication network is necessary for RS232 communication. If the installed location of RFID system in the factory is changed or extended, a reinstallment is required for the already installed wired data network. A large amount of time/financial reinvestment is necessary for such reinstallation. By using wireless data communication network, however, the initial installation and reinstallation are very simple. In this paper, we implemented a wireless communication system and RFID system. We used the CC1020 chip for wireless communication system and EM4095 chip for RFID system. CC1020 chip enables highly-reliable data communication, and by setting a simple status register, it can switch between transmitting/receiving status and it can choose the desired frequency of either 400 MHz or 900 MHz. Also, Communication range is 50 m, if external antenna is used. EM4095 is a chip for RFID reader system with the carrier frequency of 125 KHz. This chip can implement the reader system by connecting a small number of components. And EM4100 was used for RFID system. EM4100 is read-only type. Atmega128 is used to control a wireless communication system and RFID system. We confirm that the system can communicate without error up to 50 m from sender. In the paper, the circuit diagram and operation program for CC1020 and RFID system are presented. The system used in the experiment is shown in pictures, and the data movement pattern of CC1020 is shown in the diagram, and the performance of each transmission method is presented.