Journal of the Korean Institute of Telematics and Electronics D
/
v.35D
no.11
/
pp.62-69
/
1998
The general degradation model has been applied to analyze the hot carrier induced degradation of the DC and RF characteristics of RF-nMOSFET. The degradation of cut-off frequency has been severer than the degradation of bulk MOSFET drain current. The value of the degradation rate n and the degradation parameter m for RF-nMOSFET has been equal to those for bulk MOSFET. The decrease of device degradation with the increase of fingers could be explained by the large source/drain parasitic resistance and drain saturation voltage. It has been also found that the RF performance degradation could be explained by the decrease of $g_{m}$ and $C_{gd}$ and the increase of $g_{ds}$ after stress. The degradation of the DC and RF characteristics of RF-nMOSFET could be predicted by the measurement of the substrate current.t.
Proceedings of the Materials Research Society of Korea Conference
/
2011.10a
/
pp.34.2-34.2
/
2011
본 연구에서는 1986년에 국내 섬 지역에 설치된 태양전지 모듈을 대상으로 전기적 특성값의 열화 및 열화 원인에 대한 분석을 실시하였다. 태양전지 모듈의 초기 최대 출력값은 50 W였고, 5인치 단결정 실리콘 태양전지 36개로 구성되어 있었다. 첫째로, 육안 검사를 통해서 태양전지 모듈의 열화 현상을 관찰하였다. 태양전지 모듈의 절연성은 IEC 61215의 기준으로 측정하였다. 태양전지 모듈의 전기적 특성평가를 통해서 최대 출력값의 변화량을 측정하였고, EL(Electroluminescence) 측정을 통해서 태양전지의 열화를 분석하였다. 이를 통해 분석된 주요 열화 모드는 봉지재 (Encapsulant)의 변색(Discoloration) 및 박리(Delamination)현상이었다. 봉지재의 변색된 부분 및 변색되지 않은 부분의 태양광 반사도를 측정한 결과 변색된 부위의 반사도가 증가한 것을 확인하였다. 두번째로 최대 출력전압을 태양전지 모듈에 인가한 상태에서 태양전지 각각의 온도를 T.C (Thermocouple)을 이용하여 측정하였고, 이를 통해서 태양전지의 열화와 온도와의 관계를 분석하였다. 마지막으로 태양전지 모듈의 단면분석을 통해서 봉지재의 박리현상 및 리본와이어의 솔더 접합계면을 관찰하였다. 또한, 봉지재를 제거한 후에 SEM&EDX를 통해서 리본와이어 및 금속전극의 부식현상을 분석하였다.
Proceedings of the Korean Reliability Society Conference
/
2011.06a
/
pp.61-70
/
2011
본 논문에서는 전원회로에 사용되는 주요 부품인 트랜스포머에 대한 주요한 고장모드, 고장메커니즘, 스트레스 인자들을 규정하고 그에 따른 가속열화시험을 실시하여 가장 유효한 스트레스 인자를 도출하고 트랜스포머의 열화가 전원회로에 미치는 영향을 분석에 대한 연구를 진행하였다. 전원회로의 고장분석에서, 트랜스포머의 일시적인 특성변화 또는 고장현상(Bunt, Short, Open 등) 발생으로 인한 전류의 급증, 공진주파수 부조화, Spike 발생 등으로 인한 주변부품 또는 구성회로에 미치는 영향을 정확하게 분석하는 것이 어렵다는 점과 비교적 단순한 구조와 강한 내성으로 뚜렷한 고장모드를 보이지 않는 특징으로 인해 전원회로의 고장원인이 트랜스포머 외의 반도체 소자, 저항, 커패시터 등에 의한 것으로 분석되는 것이 일반적이다. 유효한 스트레스 인자별 가속열화시험을 통한 성능평가에서는 절연저항을 제외한 특성에서는 뚜렷한 변화(열화)를 보이지 않았고, 고온고습에 의한 스트레스에서 가장 절연저항의 급격한 열화를 확인할 수 있었다. 또한 열화 각각의 스트레스 인자에 따라 열화시킨 트랜스포머를 실장하여 평가하는 실증적인 방법을 통해 분석한 결과 트랜스포머의 열화는 스위칭소자를 비롯한 주변부품에 스트레스를 가중시켜 발열로 대변되는 현상을 유발하고 트랜스포머 입출력 양단간의 위상편차는 심화시키는 것으로 나타났으며, 스트레스 인자 중 온습도에 의한 영향이 가장 유효하다는 것으로 확인할 수 있었다.
In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.
Journal of Korean Association for Spatial Structures
/
v.11
no.1
/
pp.97-104
/
2011
This paper contains of descriptions of deterioration diagnosis of the surface and a coating layer for maintenance managements of large spatial structures with membrane structure. Membrane is a roofing material of the structures that its performance of durability including its performance of chemical resistance and corrosive resistance is considered to be highly important. In general, the items of diagnosis for maintenance managements such as membrane extensively include the diagnosis of deterioration of the membrane surface, of a coating layer of membrane, the diagnosis of deterioration between a coating layer and fiber, of overall surface of membrane, of the class of ropes, of reinforced belts, and of the cover of rubber. The object of this study that needs maintenance managements of the membrane with PVC and FIFE which are commonly used and shows the diagnosis results of deterioration of the surface and a coating layer.
Until a recent day, degradation of PEMFC MEA(membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. During simultaneous degradation, there was interaction between membrane degradation and electrode degradation. Hydrogen permeability was used often to measure degradation of electrolyte membrane in PEMFC. In case of hydrogen permeability measured by LSV(Linear Sweep Voltammetry) method, the degradation of electrode decrease the value of hydrogen crossover current due to LSV methode's dependence on electrode active area. In this study hydrogen permeability was measured by gas chromatograph(GC) when membrane and electrode degraded at the same time. It was showed that degradation of electrode did not affect the hydrogen permeability measured by GC because of GC methode's independence on electrode active area.
Kim, Jeong-Pyo;Seok, Chang-Sung;Song, Sung-Jin;Kim, Young-Hwan
Journal of the Korean Society for Nondestructive Testing
/
v.21
no.5
/
pp.549-555
/
2001
Ultrasonic is a powerful nondestructive technique for getting the information of flaws and material properties of in-services facilities. We prepared 4 different 1Cr-1Mo-0.25V specimens by Isothermal aging at $630^{\circ}C$. We evaluated material degradation using ultrasonic parameters, velocity, attenuation and harmonic generation. Attenuation and nonlinear parameter derived from harmonic generation efficiency increased as degradation. Especially the second harmonic of the fundamental wave in the 1,820h aging material was observed to exceed 20dB more than that in the un-aged material. But velocity remained virtually the same for all specimens. We concluded that nonlinear parameter and attenuation are sensitive to material degradation, but velocity was not. It'll be a good parameter for evaluating the material degradation.
고온.고압하에서 장시간 사용되는 고온부재용 구조물은 경년열화현상을 나타낸다 그러므로 구조물의 안정성 측면에서 재질열화의 정도를 정량적으로 평가하는 것이 중요하다. 그러나 실기 구조물에서 채취할 시험편의 크기와 수는 제한이 되기 때문에 새로운 비파괴적인 평가법이 요구되고 있다. 따라서 본 연구에서는 화력발전설비에 이용되는 탄소강과 페라이트강에 대한 열화도의 평가를 위해 입계부식법의 적용 가능성을 조사한다. 시험결과, 재질열화의 정도는 사용시간보다 사용온도에 더 큰 영향을 받았으며, Larson-Miller인자와 열화도([$\Delta$DBTT]SP)사이의 관계는 선형적이었으나, 강종에 따라 다른 기울기를 보였다. 반면, 연성-취성천이온도 ([$\Delta$DBTT]SP)와 격자절단비(Ni/No)와 관계는 강종에 무관하게 선형적인 비례관계를 나타내었다. 또한, [$\Delta$DBTT]SP와 Ni/No 의 관계로부터 입계부식법은 페라이트계 강뿐만아니라 탄소강에 대해서도 유용한 재질열화 평가 방법임을 알 수 있었다.
Proceedings of the Korea Multimedia Society Conference
/
2012.05a
/
pp.312-313
/
2012
단청의 열화현상에 대한 연구는 주로 건축재로서의 내구성 향상에 초점을 두고 연구가 진행되고 있으나 본 연구는 가상유적지 재현을 위해 가상 건축물의 사실감을 높이기 위한 방안으로서 열화현상을 분석하고 가시화 하는데 초점을 두었다. 이를 위해 먼저, 전통건축에 나타나는 단청의 열화과정을 인간이 인지하는 색채감의 변화에 초점을 두고 연구를 진행한다. 우리나라 단청에서 사용된 안료를 살펴보고 문화재관리청에서 선정한 무기안료와 유기안료를 중심으로 내후성 시험을 통해 안료의 열화현상을 분석한다. 단청의 열화를 크게 색변과 박리 현상으로 나누어 촉진내후성시험기를 통해 얻어진 결과를 토대로 목조 전통건축의 열화현상을 분석한다.
배전급 전력케이블의 장기수명특성 평가를 위한 기초자료를 확보하기 위해 고창 배전 실증시험장내에 장기열화시험을 수행할 수 있는 실증시험설비가 구축되었다. 이 설비를 안전하고 효과적으로 관리 운영하기 위해 원격감시제어기능, 자동운전기능 및 열화데이터의 효과적이 처리기능이 포함된 장기열화설비 자동화시스템의 구축이 필요하였다. 따라서 본 논문에서는 새롭게 개정된 한전 표준구매규격과 참고규격인 개정판 AEIC CS5 규격에 맞게 구축된 배전급 전력케이블 장기 열화시험설비를 원격감시제어, 자동운전 및 열화 데이터의 저장 및 처리가 가능한 전력케이블 장기열화설비 자동화시스템의 하드웨어 구성 및 MMI (Man-Machine Interface)화면의 구성방안에 대하여 기술하였다. 본 자동화시스템을 이용해 기존의 간이 차수형 CNCV케이블의 AEIC규격 수트리시험을 안전하게 수행하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.