Hot electron induced degradation model of the DC and RF characteristics of RF-nMOSFET (Hot electron에 의한 RF-nMOSFET의 DC및 RF 특성 열화 모델)

  • 이병진;홍성희;유종근;전석희;박종태
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.62-69
    • /
    • 1998
  • The general degradation model has been applied to analyze the hot carrier induced degradation of the DC and RF characteristics of RF-nMOSFET. The degradation of cut-off frequency has been severer than the degradation of bulk MOSFET drain current. The value of the degradation rate n and the degradation parameter m for RF-nMOSFET has been equal to those for bulk MOSFET. The decrease of device degradation with the increase of fingers could be explained by the large source/drain parasitic resistance and drain saturation voltage. It has been also found that the RF performance degradation could be explained by the decrease of $g_{m}$ and $C_{gd}$ and the increase of $g_{ds}$ after stress. The degradation of the DC and RF characteristics of RF-nMOSFET could be predicted by the measurement of the substrate current.t.

  • PDF

25년 장기간 동작된 태양전지 모듈의 열화모드 및 열화메커니즘 분석

  • Park, No-Chang;Han, Chang-Un;Kim, Dong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.34.2-34.2
    • /
    • 2011
  • 본 연구에서는 1986년에 국내 섬 지역에 설치된 태양전지 모듈을 대상으로 전기적 특성값의 열화 및 열화 원인에 대한 분석을 실시하였다. 태양전지 모듈의 초기 최대 출력값은 50 W였고, 5인치 단결정 실리콘 태양전지 36개로 구성되어 있었다. 첫째로, 육안 검사를 통해서 태양전지 모듈의 열화 현상을 관찰하였다. 태양전지 모듈의 절연성은 IEC 61215의 기준으로 측정하였다. 태양전지 모듈의 전기적 특성평가를 통해서 최대 출력값의 변화량을 측정하였고, EL(Electroluminescence) 측정을 통해서 태양전지의 열화를 분석하였다. 이를 통해 분석된 주요 열화 모드는 봉지재 (Encapsulant)의 변색(Discoloration) 및 박리(Delamination)현상이었다. 봉지재의 변색된 부분 및 변색되지 않은 부분의 태양광 반사도를 측정한 결과 변색된 부위의 반사도가 증가한 것을 확인하였다. 두번째로 최대 출력전압을 태양전지 모듈에 인가한 상태에서 태양전지 각각의 온도를 T.C (Thermocouple)을 이용하여 측정하였고, 이를 통해서 태양전지의 열화와 온도와의 관계를 분석하였다. 마지막으로 태양전지 모듈의 단면분석을 통해서 봉지재의 박리현상 및 리본와이어의 솔더 접합계면을 관찰하였다. 또한, 봉지재를 제거한 후에 SEM&EDX를 통해서 리본와이어 및 금속전극의 부식현상을 분석하였다.

  • PDF

트랜스포머 열화 인자 도출 및 전원회로 영향성에 관한 연구

  • Lee, Yeong-Ju;Im, Hong-U;Han, Ji-Hun;Lee, Mu-Seok
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.61-70
    • /
    • 2011
  • 본 논문에서는 전원회로에 사용되는 주요 부품인 트랜스포머에 대한 주요한 고장모드, 고장메커니즘, 스트레스 인자들을 규정하고 그에 따른 가속열화시험을 실시하여 가장 유효한 스트레스 인자를 도출하고 트랜스포머의 열화가 전원회로에 미치는 영향을 분석에 대한 연구를 진행하였다. 전원회로의 고장분석에서, 트랜스포머의 일시적인 특성변화 또는 고장현상(Bunt, Short, Open 등) 발생으로 인한 전류의 급증, 공진주파수 부조화, Spike 발생 등으로 인한 주변부품 또는 구성회로에 미치는 영향을 정확하게 분석하는 것이 어렵다는 점과 비교적 단순한 구조와 강한 내성으로 뚜렷한 고장모드를 보이지 않는 특징으로 인해 전원회로의 고장원인이 트랜스포머 외의 반도체 소자, 저항, 커패시터 등에 의한 것으로 분석되는 것이 일반적이다. 유효한 스트레스 인자별 가속열화시험을 통한 성능평가에서는 절연저항을 제외한 특성에서는 뚜렷한 변화(열화)를 보이지 않았고, 고온고습에 의한 스트레스에서 가장 절연저항의 급격한 열화를 확인할 수 있었다. 또한 열화 각각의 스트레스 인자에 따라 열화시킨 트랜스포머를 실장하여 평가하는 실증적인 방법을 통해 분석한 결과 트랜스포머의 열화는 스위칭소자를 비롯한 주변부품에 스트레스를 가중시켜 발열로 대변되는 현상을 유발하고 트랜스포머 입출력 양단간의 위상편차는 심화시키는 것으로 나타났으며, 스트레스 인자 중 온습도에 의한 영향이 가장 유효하다는 것으로 확인할 수 있었다.

  • PDF

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.

Deterioration Diagnosis of Surface and Coating Layer for Maintenance Managements of the Membrane Structure (막구조 건축물의 유지관리를 위한 표면 및 코팅층의 열화 진단)

  • Kang, Joo-Won;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.97-104
    • /
    • 2011
  • This paper contains of descriptions of deterioration diagnosis of the surface and a coating layer for maintenance managements of large spatial structures with membrane structure. Membrane is a roofing material of the structures that its performance of durability including its performance of chemical resistance and corrosive resistance is considered to be highly important. In general, the items of diagnosis for maintenance managements such as membrane extensively include the diagnosis of deterioration of the membrane surface, of a coating layer of membrane, the diagnosis of deterioration between a coating layer and fiber, of overall surface of membrane, of the class of ropes, of reinforced belts, and of the cover of rubber. The object of this study that needs maintenance managements of the membrane with PVC and FIFE which are commonly used and shows the diagnosis results of deterioration of the surface and a coating layer.

Measurement of Hydrogen Crossover by Gas Chromatograph in PEMFC (고분자전해질 연료전지에서 기체 크로마토그래프에 의한 수소투과도 측정)

  • Jeong, Jaejin;Jeong, Jaehyeun;Kim, Saehoon;Ahn, Byungki;Ko, Jaijoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.425-429
    • /
    • 2014
  • Until a recent day, degradation of PEMFC MEA(membrane and electrode assembly) has been studied, separated with membrane degradation and electrode degradation, respectively. But membrane and electrode were degraded coincidentally at real PEMFC operation condition. During simultaneous degradation, there was interaction between membrane degradation and electrode degradation. Hydrogen permeability was used often to measure degradation of electrolyte membrane in PEMFC. In case of hydrogen permeability measured by LSV(Linear Sweep Voltammetry) method, the degradation of electrode decrease the value of hydrogen crossover current due to LSV methode's dependence on electrode active area. In this study hydrogen permeability was measured by gas chromatograph(GC) when membrane and electrode degraded at the same time. It was showed that degradation of electrode did not affect the hydrogen permeability measured by GC because of GC methode's independence on electrode active area.

A Study on the Evaluation of Material Degradation for 1Cr-1Mo-0.25V Steel using Linear and Nonlinear Ultrasonics (선형 및 비선형 초음파를 이용한 1Cr-1Mo-0.25V의 열화평가에 관한 연구)

  • Kim, Jeong-Pyo;Seok, Chang-Sung;Song, Sung-Jin;Kim, Young-Hwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.549-555
    • /
    • 2001
  • Ultrasonic is a powerful nondestructive technique for getting the information of flaws and material properties of in-services facilities. We prepared 4 different 1Cr-1Mo-0.25V specimens by Isothermal aging at $630^{\circ}C$. We evaluated material degradation using ultrasonic parameters, velocity, attenuation and harmonic generation. Attenuation and nonlinear parameter derived from harmonic generation efficiency increased as degradation. Especially the second harmonic of the fundamental wave in the 1,820h aging material was observed to exceed 20dB more than that in the un-aged material. But velocity remained virtually the same for all specimens. We concluded that nonlinear parameter and attenuation are sensitive to material degradation, but velocity was not. It'll be a good parameter for evaluating the material degradation.

  • PDF

A Study on the Evaluation of Material Degradation for High Temperature Sturctural Components by Using Grain Boundary Etching method (입계육식법에 의한 고온부재의 경년 열화도 평가에 관한 연구)

  • Yu, Hyo-Seon;Jeong, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.6 no.3
    • /
    • pp.253-263
    • /
    • 1996
  • 고온.고압하에서 장시간 사용되는 고온부재용 구조물은 경년열화현상을 나타낸다 그러므로 구조물의 안정성 측면에서 재질열화의 정도를 정량적으로 평가하는 것이 중요하다. 그러나 실기 구조물에서 채취할 시험편의 크기와 수는 제한이 되기 때문에 새로운 비파괴적인 평가법이 요구되고 있다. 따라서 본 연구에서는 화력발전설비에 이용되는 탄소강과 페라이트강에 대한 열화도의 평가를 위해 입계부식법의 적용 가능성을 조사한다. 시험결과, 재질열화의 정도는 사용시간보다 사용온도에 더 큰 영향을 받았으며, Larson-Miller인자와 열화도([$\Delta$DBTT]SP)사이의 관계는 선형적이었으나, 강종에 따라 다른 기울기를 보였다. 반면, 연성-취성천이온도 ([$\Delta$DBTT]SP)와 격자절단비(Ni/No)와 관계는 강종에 무관하게 선형적인 비례관계를 나타내었다. 또한, [$\Delta$DBTT]SP와 Ni/No 의 관계로부터 입계부식법은 페라이트계 강뿐만아니라 탄소강에 대해서도 유용한 재질열화 평가 방법임을 알 수 있었다.

  • PDF

Analysis and Visualization on Aging Effects for Dan-Cheong Pigments (단청안료의 열화 현상 분석 및 가시화 방안)

  • Shin, D.K.;Kim, J.W.;Ahn, E.Y.
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2012.05a
    • /
    • pp.312-313
    • /
    • 2012
  • 단청의 열화현상에 대한 연구는 주로 건축재로서의 내구성 향상에 초점을 두고 연구가 진행되고 있으나 본 연구는 가상유적지 재현을 위해 가상 건축물의 사실감을 높이기 위한 방안으로서 열화현상을 분석하고 가시화 하는데 초점을 두었다. 이를 위해 먼저, 전통건축에 나타나는 단청의 열화과정을 인간이 인지하는 색채감의 변화에 초점을 두고 연구를 진행한다. 우리나라 단청에서 사용된 안료를 살펴보고 문화재관리청에서 선정한 무기안료와 유기안료를 중심으로 내후성 시험을 통해 안료의 열화현상을 분석한다. 단청의 열화를 크게 색변과 박리 현상으로 나누어 촉진내후성시험기를 통해 얻어진 결과를 토대로 목조 전통건축의 열화현상을 분석한다.

  • PDF

A Study on Constructing the Automatic Control System of the Power Cable lest Facility (배전급 전력케이블 장기열화설비 자동화시스템 구축에 관한 연구)

  • Kang Moon Ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.512-514
    • /
    • 2004
  • 배전급 전력케이블의 장기수명특성 평가를 위한 기초자료를 확보하기 위해 고창 배전 실증시험장내에 장기열화시험을 수행할 수 있는 실증시험설비가 구축되었다. 이 설비를 안전하고 효과적으로 관리 운영하기 위해 원격감시제어기능, 자동운전기능 및 열화데이터의 효과적이 처리기능이 포함된 장기열화설비 자동화시스템의 구축이 필요하였다. 따라서 본 논문에서는 새롭게 개정된 한전 표준구매규격과 참고규격인 개정판 AEIC CS5 규격에 맞게 구축된 배전급 전력케이블 장기 열화시험설비를 원격감시제어, 자동운전 및 열화 데이터의 저장 및 처리가 가능한 전력케이블 장기열화설비 자동화시스템의 하드웨어 구성 및 MMI (Man-Machine Interface)화면의 구성방안에 대하여 기술하였다. 본 자동화시스템을 이용해 기존의 간이 차수형 CNCV케이블의 AEIC규격 수트리시험을 안전하게 수행하였다.

  • PDF