• Title/Summary/Keyword: 'Fuji'

Search Result 549, Processing Time 0.027 seconds

Reliability of the Agro-climatic Atlases Based on the 30-Year Average Climate Data (평년 평균기후자료 기반 농업기후도의 신뢰도)

  • Kim, Jin-Hee;Kim, Dae-jun;Kim, Soo-ock
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.3
    • /
    • pp.110-119
    • /
    • 2017
  • The agroclimatic indices are produced by statistical analysis based on primary climate data (e.g., temperature, precipitation, and solar irradiance) or driving agronomic models. This study was carried out to evaluate how selection of daily temperature for a climate normal (1983-2012) affected the precision of the agroclimatic indices. As a first step, averaged daily 0600 and 1500 LST temperature for a climate normal were produced by geospatial schemes based on topo-climatology ($365days{\times}1$ set, EST normal year). For comparison, 30 years daily temperature data were generated by applying the same process ($365days{\times}30sets$), and calculated mean of daily temperature (OBS normal year). The flowering date of apple 'Fuji' cultivar, the last frost date, and the risk of late frost were estimated based on EST normal year data and compared with the results from OBS normal year. The results on flowering date showed 2.9 days of error on average. The last frost date was of 11.4 days of error on average, which was relatively large. Additionally, the risk of the late frost was determined by the difference between the flowering and the last frost date. When it was determined based on the temperature of EST normal year, Akyang was classified as a risk area because the results showed that the last frost date would be the same or later than the flowering date in the 12.5% of area. However, the temperature of OBS normal year indicated that the area did not have the risk of a late frost. The results of this study implied that it would be necessary to reduce the error by replacing the EST method with the OBS method in the future.

MORPHOLOGIC ANALYSIS OF C-SHAPED ROOT USING 3-D RECONSTRUCTION (3차원 재구성법에 의한 C-shaped root의 형태분석)

  • Jung, Eun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.421-431
    • /
    • 2002
  • C-shaped canal configuration is very difficult to treat because that clues about preoperative canal anatomy cannot be ascertained from clinical crown morphology and limited information can be derived from radiographic examination. This study was done to get more informations about the root and canal configuration of C-shape root by 3-dimensionally reconstructing for the purpose of enhancing success rate of endodontic treatment. 30 mandibular molars with C-shaped root were selected. Six photo images from occlusal, apical, mesial, distal, buccal, lingual directions and radiographic view were taken as preoperative ones to compare them with 3-D image. After crown reduction to the level of 1-2mm over pulpal floor was performed, teeth were stored in 5.25% sodium hypochlorite solution for the removal of pulp tissue and debris. They were cleaned under running water, allowed to bench dry and embedded in a self-curing resin. This resin block was serially ground with a microtome (Accutom-50, Struers, Denmark) and the image of each level was recorded by digital camera (FinePix S1-pro, Fuji Co., Japan). The thickness of each section was 0.25mm. Photographs of serial sections through all root canal were digitized using Adobe Photoshop 5.0 and then minimum thickness of open and closed sites were measured (open site is the surface containing occluso-apical groove closed site is oppsite). After dizitization using 3-D Doctor (Able software Corp, USA). 3D reconstruction of the outer surface of tooth and the inner surface of pulp space was made. Canal classsification of C-shaped roots was performed from this 3-D reconstructed image. The results were as follows : 1. Most C-shape rooted teeth showed lingual groove (28/30). 2 According to Vertuccis' calssification, type I, II, III, IV, VII were observed. but also new canal types suck as 2-3-2, 1-2-3-2. 2-3-2-1, 2-3-2-3 were shown. 3 There was little difference in minimum thickness on coronal and apical portions, but open site were thinner than closed site on mid portion. Conclusively, 3D reconstruction method could make the exact configurations of C-shape root possible to be visualized and analyzed from multi-directions. Data from minimum thickness recommend cleaning and shaping be more carefully done on dangerous mid portion.

A STUDY ON THE CHANGES IN DEGREE OF CONVERSION OF DUAL-CURE RESTORATIVE MATERIALS WITH TIME-ELAPSE (이중중합 수복재의 시간경과에 따른 중합도 변화)

  • Yang, Chul-Ho;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.554-563
    • /
    • 1999
  • For the purpose of elucidating the polymerization modes of dual-cure restorative materials and comparing them with single-cure restorative materials, a study was performed on the light-cured composite resin, dual-cure composite resin, dual-cure glass ionomer cement and chemical-cure glass ionomer cement. By measuring the microhardness of each material at 0mm, 1mm and 3mm depth during initial 24 hours with predetermined interval, the state of polymerization and degree of conversion was indirectly evaluated for each material, and obtained results are as follows : 1. All of four materials tested showed significant increase in microhardness after 24hrs compared with just after curing starts. 2. In all materials except Ketac-fil, there showed a significant difference in microhardness between each depth at each time interval. 3. In the test of lap time till final curing for each material, the polymerization process was revealed to last longer in the dual-cure type materials than in single-cure type materials at 3mm depth. Based on the results above, it was demonstrated with materials of dual-cure mode that the degree of conversion increases by successive curing reactions even in the deeper layers where sufficient curing light is impermeable.

  • PDF

A COMPARISON OF THE BOND STRENGTHS BETWEEN SOME CEMENTS AND STAINLESS STEEL MATERIAL (Stainless steel crown을 위한 수종 시멘트의 접착력 비교)

  • Kim, Hong-Ryoul;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.528-537
    • /
    • 1999
  • The purpose of this study was to analyze and compare the bond strengths between stainless steel plate and zinc phosphate cement, polycarboxylate cement and glass ionomer cement, which are frequently used for cementation of stainless steel crowns. Three cementing materials were glued to the poles standing above stainless steel plate, bovine teeth, light cured glass ionomer restorative material and amalgam. And the tensile bond strengths between them were measured with universal testing machine and the results were statistically processed using ANOVA and Student t-test. The obtained results were as follows : 1. On stainless steel plate, glass ionomer cement and polycarboxylate cement showed higher tensile bond strengths compared to zinc phosphate cement, with no significant difference between the former two. 2. On the surface of bovine teeth and glass ionomer restorative material, glass ionomer cement showed highest bond strength, followed by polycarboxylate cement and zinc phosphate cement in order. 3. For amalgam restoration, polycarboxylate cement and glass ionomer cement showed higher tensile bond strengths than zinc phosphate cement, with no significant difference between the former two.

  • PDF

Production of Ethylene and Carbon Dioxide in Apples during CA Stroage (사과의 CA저장 중 에틸렌 및 이산화탄소 생성)

  • 정헌식;최종욱
    • Food Science and Preservation
    • /
    • v.6 no.2
    • /
    • pp.153-160
    • /
    • 1999
  • This study was carried out to investigate the production of C$_2$H$_4$ and CO$_2$, and the change of flesh firmness and peel color in 'Fuji' apples during CA storage. ACC oxidase activity was more inhibited by the low O$_2$ concentration, and the low level of internal C$_2$H$_4$ in apples was maintained under the low O$_2$ conditions during 8 months storage. Especially, the level of internal C$_2$H$_4$ in apples was maintained below 1 ppm during storage under 1% O$_2$+1% CO$_2$ at 0$^{\circ}C$, and not much changed for 7 days in air at 20$^{\circ}C$ after storage. The influence of CO$_2$ on the C$_2$H$_4$ production was dependent on the O$_2$ concentration. Increasing of CO$_2$ concentration with 3% O$_2$ decreased the C$_2$H$_4$ Production during storage, but that with 1% O$_2$increased. Internal C$_2$H$_4$ concentration and the rate of CO$_2$ evolution in apples showed the close correlation. Internal CO$_2$ concentration of apples was positively related to the rate of CO$_2$ evolution and maintained the lower level in 1% O$_2$+1% CO$_2$ than the other conditions during storage but nu different in the increment after storage. The relationship between C$_2$H$_4$ and CO$_2$ production was exhibited in CA and the short-term air stored apples, but not in the long-term air stored apples. Loss of flesh firmness and green color in apples was more less in storage condition retarded effectively the production of C$_2$H$_4$ and CO$_2$.

  • PDF

A STUDY ON THE ACCURACY OF DENTAL CAST AND DIE MATERIALS USING PHOTO-SCANNING (사진 주사(走査)를 이용한 치과용 모형재의 정확도에 관한 연구)

  • Yang, Seong-Wook;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.320-334
    • /
    • 1996
  • Dental cast and die materials are essential material using in almost dental prsthodontic procedure and it's most important requirement is accuracy for reqorducing the oral anatomical structures. In this study, 5 abutments A, B, C, D, E were fabricated on the metal master model to simulate the arch form and specimens were poured with 4 cast materials. Inter-abutment distances, A-B, A-C, A-D, A-E, B-C, B-D were calculated using the photo-scanning and the deviations from the metal master model were also evaluated. The results were as follows; 1. The distance between A-B, A-C, A-D, A-E, B-C, B-D of the abutments A, B, C, D, E of each cast material was calculated. And after comparing the deviations between the metal master model. $Fujirock^{(R)}$ showed the lowest value with $0.20{\pm}0.22mm$, and the deviation increased in the order of $Suprastone^{(R)}$, Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. 2. In each calculation area, the difference in measurements between cast material and metal master model showed singificant difference between A-B and Cross arch measure-ments of A-D, B-D, A-E(p<0.05). 3. The difference in measurements between cast material and metal master model in the A-B area showed $Fujirock^{(R)}$ to be the lowest with $0.05{\pm}0.04$mm and increased in the order of Die $Keen^{(R)}$, $Suprastone^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and $Suprastone^{(R)}$, Epoxy $Die^{(R)}$ (p<0.05). 4. The difference in measurements between cast material and metal master model in the B-C area showed $Fujirock^{(R)}$ to bo the lowest with $0.17{\pm}0.11$mm and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Die $Keen^{(R)}$, Epoxy $Die^{(R)}$(p<0.05). 5. The difference in measurements between cast material and metal master model in the B-D area showed $Fujirock^{(R)}$ to bo the lowest with $0.13{\pm}0.07$mm, Epoxy $Dies^{(R)}$and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fuji-rock^{(R)}$ and Die Keen(p<0.05). 6. In this experiment, Epoxy $Dies^{(R)}$ showed mean contraction in every calculation area. And when reconstruction cross arch restorations it is thought that distortion should be considered in every cast material.

  • PDF

A STUDY ON THE HUMAN PULPAL RESPONSE TO DENTIN BONDING DESENSITIZER (상아질 접착 지각과민 처치제에 대한 치수반응에 관한 연구)

  • You, Hee-Seung;Lee, Sung-Bok;Woo, Yi-Hyung;Park, Nam-Soo;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.483-495
    • /
    • 1998
  • The purpose of this study was to evaluate the human pulpal response to Dentin Bonding Desensitizer. Class V cavities were prepared on the buccal surfaces of the first premolars and Dentin Bonding Desensitizer(ALL-BOND Desensitizer, Bisco, Inc. U.S.A.) was applicated in ten experimental teeth, or ZOE(PROPAC, GC Co. TOKYO, JAPAN) cement in eight control teeth and cavities were filled with light curing glass ionomer(Fuji II LC, GC Co., TOKYO, JAPAN). At 3-day and 25-day postoperative interval. pulpal response was observed and evaluated histologically with light microscope. The results were as follows. ; 1. At 3-day postoperative interval, the control teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. 2. At 25-day postoperative interval, all control teeth were grade 1 inflammatory cell response and in three control teeth grade 1 connective tissue response were observed, and one teeth showed grade 2 connective tissue response. 3. At 3-day postoperative interval, the experimental teeth were grade 1 inflammatory cell response and grade 1 connective tissue response. Below the cavity, a few inflammatory cell(PMNs) in odontoblastic layer, increased blood vessels and pulpal cells were seen and this pulpal response was similar to control teeth. 4. At 25-day postoperative interval, in four experimental teeth grade 1 inflammatory cell response and grade 1 connective tissue response were observed, and one experimental teeth showed mild inflammatory response. 5. At 3-day and 25-day postoperative interval, no reparative dentin deposition was seen. 6. Both experimental and control group, pulpal response showed difference between 3 and 25-day of postoperative interval. In control teeth, increased predentin and pulpal cells were seen and in experimental teeth, congestion of blood vessels and increased pulpal cells were seen. In conclusion, the pulpal irritation due to this Dentin Bonding Desensitizer was not severe, and it was considered that the agent was not harmful to the human pulp.

  • PDF

FLUORIDE RELEASE AND MICROHARDNESS OF GIOMER ACCORDING TO TIME (Giomer의 불소 유리 양상 및 미세경도에 관한 연구)

  • Kim, Sang-Min;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.429-437
    • /
    • 2010
  • The aim of this study was to evaluate the fluoride release and microhardness of Beautifil II as giomer(Group I), F2000 Compomer as compomer(Group II), GC Fuji II LC Capsule as resin-modified glass ionomer(Group III) and $Filtek^{TM}$ Z350 as composite resin(Group IV) according to time. Forty discs(5 mm diameter and 2 mm height) were prepared for each material. Each disc was immersed in 3 ml of de-ionized water within polyethylene tube and stored at $37^{\circ}C$. Evaluations were performed by pH/ISE meter for analysis of fluoride release and hardness testing machine for analysis of microhardness over 31 days. The results can be summarized as follows : 1. For all groups except group IV, the greatest fluoride release was observed after the first day of the study period and then dramatically diminished over time. On the 7th day of the study period, fluoride release level was stabilized. 2. Group III showed the highest fluoride release among test groups and then group II, group I were followed. Significant difference in cumulative fluoride release over 31 days was found between each groups. Group IV showed no fluoride release during study period. 3. Group IV showed the highest microhardness among test groups and then group I, group II, group III were followed. Significant difference in microhardness was found between each group, except between group I and group II. 4. After 31 days, microhardness was slightly diminished in every group. However, no significant difference was found.

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

Effect of Self-incompatibility Control Substances on the Quality and Fruiting of Apple (사과에 있어서 자가불화합 제어제 처리 효과)

  • Son, Tae-Kwon;Chung, Il-Kyung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.264-268
    • /
    • 2006
  • This study investigated the effect of self-incompatibility control substance 'Apple plus' in improving self-fertilization and quality on apple. Results showed that the rate of fruit setting of disc florets of Fuji apple in the open field increased from 17.2% in 2004 to 44.4% in 2005 for the treated plots and from 0.5% in 2004 to 3.0% in 2005 for the control. In the case of using net covering, the rate of fruit setting increased from 3.3% in 2004 to 5.2% in 2005 for the treated plots and from 0.4% in 2004 to 0.1% in 2005 for the control. For the quality of apple fruits, results showed that there was no significant difference on the fruit L/D and firmness for both control and treated plots. However, the number of seeds was affected by the different substances which produced the following average number of seeds: control, 0.9; IS-1, 1.2; IS-2, 1.2; IS-3, 1.5 and IS-4, 0.7. The SSR genetic analysis showed that the rate of self-fertilization was highest for IS-1 (100%), followed by IS-2 (73%), IS-3 (68%), IS-4 (62%) and control (0%).