• Title/Summary/Keyword: %24NO_X%24

Search Result 600, Processing Time 0.03 seconds

Relationships between Methionine Supply, Nitrogen Retention and Plasma Insulin-like Growth Factor-I in Growing Sheep Nourished by Total Intragastric Infusions

  • Li, Chong;Zhao, Guangyong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.10
    • /
    • pp.1393-1398
    • /
    • 2011
  • Four 4-month old Charolais${\times}$Dorset male sheep (initial liveweight $25.0{\pm}1.1\;kg$), fitted with rumen and abomasal fistulas and nourished by total intragastric infusions, were used to study the relationships between methionine (Met) supply, nitrogen (N) retention and plasma insulin-like growth factor-I (IGF-I). Four graded levels of Met, i.e. 0 g/16 g N, 1.76 g/16 g N, 3.52 g/16 g N and 7.04 g/16 g N, were infused into abomasums as experimental treatments. The sheep and treatments were allocated in a $4{\times}3$ incomplete Latin square design (Yudon square design). The experiment lasted 3 periods and each period was 10 days. Quadratic correlations were found between Met level (x, g/16 g N) and N retention (y, g/d): y = $-0.03x^2$+0.41x+2.62, $r^2$ = 0.66, n = 12, p = 0.008, and between methionine level (x, g/16 g N) and plasma IGF-I concentration (y, ng/ml): y = $0.80x^2$-4.53x+190.24, $r^2$ = 0.51, n = 12, p = 0.009. No significant correlation was found between plasma IGF-I (x, ng/ml) and N retention (y, g/d) (p>0.05). It was concluded that Met level had a significant influence on N retention and plasma IGF-I concentration whereas IGF-I might not be an important mediator in the regulation of N metabolism by Met in growing sheep nourished by total intragastric infusions.

Oxygen Permeation and Hydrogen Production of BaCo1-x-yFexZryO3-δ by a Modified Glycine-nitrate Process (MGNP) (Modified glycine-nitrate process(MGNP)로 합성한 BaCo1-x-yFexZryO3-δ 산소투과도 및 수소생산성)

  • Yi, Eunjeong;Hwang, Haejin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • A dense mixed ionic and electronic conducting ceramic membrane is one of the most promising materials because it can be used for separation of oxygen from the mixture gas. The $ABO_3$ perovskite structure shows high chemical stability at high temperatures under reduction and oxidation atmospheres. $BaCo_{1-x-y}Fe_xZr_yO_{3-{\delta}}$ (BCFZ) was well-known material as high mechanical strength, low thermal conductivity and stability in the high valence state. Glycine Nitrate Process (GNP) is rapid and effective method for powder synthesis using glycine as a fuel and show higher product crystallinity compared to solid state reaction and citrate-EDTA method. BCFZ was fabricated by modified glycine nitrate process. In order to control the burn-up reaction, $NH_4NO_3$ was used as extra nitrate. According to X-Ray Diffraction (XRD) results, BCFZ was single phase regardless of Zr dopants from y=0.1 to 0.3 on B sites. The green compacts were sintered at $1200^{\circ}C$ for 2 hours. Oxygen permeability, methane partial oxidation rate and hydrogen production ability of the membranes were characterized by using Micro Gas Chromatography (Micro GC) under various condition. The high oxygen permeation flux of BCFZ 1-451 was about $1ml{\cdot}cm^{-2}s^{-1}$. Using the humidified Argon gas, BCFZ 1-433 produced hydrogen about $1ml{\cdot}cm^{-2}s^{-1}$.

Consideration of Surface Dose and Depth of Maximum Dose Using Various Detectors for High Energy X-rays (측정기에 따른 고에너지 X-선의 표면 선량 및 최대 선량 지점 고찰)

  • Lee Yong Ha;Park Kyung Ran;Lee Jong Young;Lee Ik Jae;Park Young Woo;Lee Kang Kyoo
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.322-329
    • /
    • 2003
  • Purpose: It is difficult to exactly determine the surface dose and the dose distribution In buildup region of high energy X-rays by using the conventional ion chamber. The aim of this study Is to evaluate the accuracy of widely used dosimetry systems to measure the surface dose and the depth of maximum dose (d$_{max}$). Materials and Methods: We measured the percent depth dose (PDD) from the surface to the d$_{max}$ in either a water phantom or in a solid water phantom using TLD-100 chips, thimble type ion chamber, diode detector, diamond detector and Markus parallel plate ion chamber for 6 MV and 15 MV X-rays, 10$\times$10 cm$^{2}$, at SSD=100cm. We analysed the surface dose and the d$_{max}$. In order to verify the accuracy of the TLD data, we executed the Monte Carlo simulation for 5 MV X-ray beams. Results: The surface doses In 6 MV and IS MV X-rays were 29.31% and 23.36% ior Markus parallel plate ion chamber, 37.17$\%$ and 24.01$\%$ for TLD, 34.87$\%$ and 24.06$\%$ for diamond detector, 38.13$\%$ and 27.8$\%$ for diode detector, and 47.92$\%$ and 35.01$\%$ for thimble type ion chamber, respectively. in Monte Carlo simulation for 6 MV X-rays, the surface dose was 36.22$\%$, which Is similar to the 37.17$\%$ of the TLD measurement data. The d$_{max}$ In 6 WV and 15 MV X-rays was 14$\~$16 mm and 27$\~$29 mm, respectively. There was no significant difference in the d$_{max}$ among the detectors. Conclusion: There was a remarkable difference in the surface dose among the detectors. The Markus parallel plate chamber showed the most accurate result. The surface dose of the thimble ion chamber was 10$\%$ higher than that of other detectors. We suggest that the correction should be made when the surface dose of the thimble ion chamber Is used for the treatment planning ion the supeficial tumors. All the detectors used In our study showed no difference in the d$_{max}$.

Some Statistical Considerations for the Estimation of Urinary Mercury Excretion in Normal Individuals (정상인의 요중 수은배설량 추정의 통계학적 연구)

  • Park, Hee-Sook;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 1980
  • Purpose of this study is to find out proper means of estimating the urinary mercury excretion in the normal individuals. Whole void volume was collected every 2 hours beginning from 6 o'clock in the morning until 6 o'clock next morning. Mercury excretion in each urine specimen was measured by NIOSH recommended dithizone colorimetric method (Method No.: P & CAM 145). Urinary concentration of mercury was adjusted by two means: specific gravity of 1.024 and a gram of creatinine excretion per liter of urine comparing the data with the unadjusted ones. Mercury excretion in 24-hour urine specimen was calculated by adding the amounts measured with the hourly collected specimens of each individual. Statistical analysis of the urinary mercury excretion revealed the following results: 1. Frequency distribution curve of mercury excreted in urine of hourly specimens was best fitted to power function expressed in the form of $y=ax^b$. Adjustment of the urinary mercury concentration by creatinine excretion was shown to be superior($y=1674x^{-1.52},\;r^2=0.95$) over nonadjustment($y=2702x^{-1.57},\;r^2=0.92$) and adjustment by specific gravity of 1.024($y=4535x^{-1.66},\;r^2=0.93$). 2. Both log-transformed mercury excretion in hourly voided specimens and mercury excretion itself in 24 hour specimens showed the normal distributions. 3. The frequency distribution of mercury adjusting the urinary concentration of mercury by creatinine excretion was best fitted to a theoretical normal distribution with the sample means and standard deviation than those unadjusted or adjusted with specific gravity of 1.024. 4. Average urinary mercury excretions in 24-hour urine specimen in an individual were as follows: a) Unadjusted mercury excretion mean and standard deviation : $$18.6{\pm}13.68{\mu}gHg/l$$. median : $$16.0\;{\mu}gHg/l$$. range : $$0.0-55.10\;{\mu}gHg/l$$. b) Adjusted with specific gravity mean : $$20.7{\pm}11.76\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ median : $$20.7\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ range : $$0.0-52.9\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ c) Adjusted with creatinine excretion mean and standard deviation : $$10.5{\pm}6.98\;{\mu}gHg/g$$ creatinine/l median : $$9.4\;{\mu}gHg/g$$ creatinine/l range : $$0.0-26.7\;{\mu}gHg/g$$ creatinine/l 5. No statistically significant differences were found between means calculated from 24-hour urine specimens and those from hourly specimens transformed into logarithmic values. (P<0.05).

  • PDF

Effects of Reduced Glutathione on Non-Protein Sulfhydryl, Non-Protein Disulfide and Oxygen Consumption Rate of Mouse Duodenum Following Whole Body X-Irradiation (Reduced Glutathione 이 X-선전신조사(線全身照射)를 입은 마우스 십이지장(十二指腸)의 NP-SH, NP-SS 및 산소소비량(酸素消費量)에 미치는 영향(影響))

  • Lee, Joong-Kil;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.55-62
    • /
    • 1971
  • In an attempt to better understand the effects of whole body X-irradiation on the levels of non-protein sulfhydryl (NP-SH), non-protein disulfide (NP-SS) and oxygen consumption rate $(QO_2)$ of the mouse duodenum, and to clarify the possible radioprotective action of reduced glutathione (GSH), a whole body X-irradiation of 1,000r was given to albino mouse either singularly or immediately after injecting GSH intraperitoneally to mouse 1 mg per gm of body weight. NP-SH was measured by Ellman's method, NP-SS was measured by the electrolytic reduction method described by Dohan and Woodward, and $(QO_2)$ by the Warburg's standard manometric method. The experiment was performed at 1, 6, 12 and 24 hours post-irradiation, and the comparison was made with the control. The results thus obtained are summarized as follows: 1) Comparing with the intrinsic NP-SH level of $3.31{\pm}0.27{\mu}\;mol/gm$ wet weight in the duodenum of the normal mouse, either whale body X-irradiation or injection of GSH alone produced no significant change in NP-SH from the normal. However, when GSH was injected prior to X-irradiation, markedly elevated NP-SH levels were observed throughout the entire experiment with the highest value of $4.70{\pm}0.10$ at 6 experimental hours. 2) The normal value of NP-SS in the mouse duodenum was $1.57{\pm}0.17{\mu}\;mol/gm$ wet weight, while in the group where injection of GSH and X-irradiation were combined, NP-SS increased to $2.36{\pm}0.33$ at 12 hours and $2.15{\pm}0.53$ at 24 hours, showing the intermediate value between the GSH injection group and X·irradiation group. 3) The normal value of $(QO_2)$ was $4.16{\pm}0.73{\mu}l\;O_2/hr./gm$ D.W., and no noticeable change was observed comparing with the GSH injection group. However, in the group where X·irradiation alone was given, $(QO_2)$ of the duodenum increased significantly throughout the entire experiment with the highest value of $6.35{\pm}1.07$ at 6 experimental hours. When GSH was injected before X-irradiation was given, the levels of $(QO_2)$ were in the middle of the GSH injection group and X-irradiation group. 4) The above results suggest that GSH may be effective as a radioprotector in terms of NP-SH, NP-SS and $(QO_2)$ of the mouse duodenum.

  • PDF

Role of the Strain Energy in Diffuse Phase Transition of (Pb, Ba)(Zr, Ti)O3 ((Pb, Ba) (Zr, Ti)O3계의 확산된 상전이에 있어서 Strain Energy의 역할)

  • 이재찬;주웅길
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.6
    • /
    • pp.586-592
    • /
    • 1987
  • The role of the strain energy and phase stability in the diffuse phase transition have been investigated in the highly disordered solid solution, (Pb1-xBax)(Zr0.4Ti0.6)O3 (0.2 x 0.4). X-ray diffraction analysis indicates that tetragonality (c/a) decreases with the increasing Ba content. Also as the Ba content increases, phase transition becomes more diffuse and at the same time dielectric relaxation as a function of measured frequencies in the 1KHz-10MHz range occurs very pronouncedly. In the Ba content range, 0.2 x 0.35, hysteresis loops are routinely observed and the loop is observed to narrow shape as the Ba content increases but becomes very slim at 40mol% Ba content. Moreover thermal analysis shows that there is no abrupt change in the thermal expansion coefficient below the apparent transition temperature at which dielectric constant becomes maximum. From the above results, it has been concluded that creation of the strain energy due to the distorthion that occurred during the phase transition suppresses diffuse phase transition.

  • PDF

Microstructural Characterization of Gas Atomized Copper-Iron Alloys with Composition and Powder Size

  • Abbas, Sardar Farhat;Kim, Taek-Soo
    • Journal of Powder Materials
    • /
    • v.25 no.1
    • /
    • pp.19-24
    • /
    • 2018
  • Cu-Fe alloys (CFAs) are much anticipated for use in electrical contacts, magnetic recorders, and sensors. The low cost of Fe has inspired the investigation of these alloys as possible replacements for high-cost Cu-Nb and Cu-Ag alloys. Here, alloys of Cu and Fe having compositions of $Cu_{100-x}Fe_x$ (x = 10, 30, and 50 wt.%) are prepared by gas atomization and characterized microstructurally and structurally based on composition and powder size with scanning electron microscopy (SEM) and X-ray diffraction (XRD). Grain sizes and Fe-rich particle sizes are measured and relationships among composition, powder size, and grain size are established. Same-sized powders of different compositions yield different microstructures, as do differently sized powders of equal composition. No atomic-level alloying is observed in the CFAs under the experimental conditions.

A Study for SCR Catalyst Reduction in Fast SCR Using Oxidation Catalyst (산화촉매를 이용한 Fast SCR에서의 SCR 촉매 저감 연구)

  • Lee, Jae Ok;Lee, Dae Hoon;Song, Young-Hoon;Oh, Dong-Kyu;Seo, Jung-Wook
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.333-336
    • /
    • 2013
  • Experimental investigation to estimate the feasibility of fast selective catalytic reduction (SCR) or oxidation catalyst combined ammonia SCR system to abate NOx in low temperature condition ($150{\sim}250^{\circ}C$) is reported. Because the conversion of NO to $NO_2$ is pre-requisite of the fast SCR process, the effect of the amount of oxidation catalyst to NO conversion to $NO_2$ was tested. 37, 45 and 51% of conversion rates were obtained for the OCV of 563000, 375000 and 281000 h, respectively. $De-NO_x$ performance in the case of $NO_2/NO_x$ ratio of 45% showed the best result in all tested temperature conditions. Comparison of the fast SCR and standard SCR with the condition of $NO_2/NO_x$ ratio of 45%, $200{\sim}250^{\circ}C$ and space velocity of 10000~30000 h showed that the fast SCR does not show much difference according to the variance of space velocity. Also it was shown that using the fast SCR, the volume of SCR catalyst can be reduced less than half of the standard SCR condition by increasing space velocity without the loss of $De-NO_x$ performance.

Studies on The Microbial Utilization of Agricultural Wastes (Part 5) Isolation and Selection of Cellulase Producing Fungi (농산폐자원의 미생물학적 이용에 관한 연구 (제오보) 섬유소분해효소 생산 곰팡이의 분리 및 선별)

  • Bae, Moo;Kim, Byung-Hong;Lee, Gye-Jun
    • Microbiology and Biotechnology Letters
    • /
    • v.4 no.3
    • /
    • pp.105-110
    • /
    • 1976
  • In the studies of microbiological utilization of cellulosic wastes, cellulolytic fungi were isolated and screened out. At the first stage, 221 cellulolytic fungi were isolated from different sources such as soils, humus, composts and rotten wood debris by enrichment culture techniques. In the second stage, 36 strains of fungi out of those previously isolated were selected for their cellulase activities estimated by means of filter paper degradation, carboxy methyl cellulose liquefaction and cup method. Activities of C$_1$-cellulase, C$\sub$x/-cellulase and filter paper activity were adopted on the final screening stage and five different strains which are tentatively identified as Aspergillus sp.(strain No. AS-9), Penicillium sp. (strain No. KNI-1-2), Trichoderma, sp. (strain No. KI-7-2, KI-7-5, KI-4-1-1B) were selected for their high potency of C$_1$ and C$\sub$x/-cellulase activities. When rice straw milled and treated with NH$_4$OH was hydrolyzed with the crude enzyme Prepared from the culture broth of Trichoderma sp. (strain No. KI-4-1-1B), saccharification rate was obtained up to 26%.

  • PDF

Removal of $NO_x$ by using of $TiB_2$ Photocatalysis ($TiB_2$ 광촉매를 이용한 $NO_x$ 제거)

  • Lee, Yong-Hwan;Choi, Im-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.112-115
    • /
    • 2009
  • This research was performed to purify water quality through removing T-N, and T-P and to estimating rate of $NO_x$ by the response of photocatalyst using ceramics. The ceramics was a mixtures of Titanium Diboride($TiB_2$) which is used to develop armored cars with excellent protective power and lightness, Olivine, and Hwangto with water and was furnaced for an hour at $1160^{\circ}C$. Hwangto and Olivine used in the study are produced at Haenam-gun, Jeonnam, and Andong-city, Gyeongsangbuk-do, respectively. The ground Hwangto and Olivine were seived through PR $100{\times}200$, and $TiB_2$ was a product of SIGMA ALDRICH. The experiment was performed under the sunlight, Mass flow controller was used for constant flow to pass through the pyrex reactor which was fully charged with furnaced ceramics. The concentration of $NO_2$ gas passed through the pyrex reactor was measured by Multi Gas Monitor. The reaction took for 60 minutes, The material was exposed to sunlight for 40 minutes. The sunlight was interrupted before and after the exposure for 10 minutes. The result showed that the concentration of $NO_2$ gas of the ceramics with $TiB_2$ and without $TiB_2$ became reduced and then maintained the same concentration under the sunlight, and became increased when the sunlight is interrupted. The $NO_2$ removing efficiency of the ceramics mixed with $TiB_2$ was 14~43% higher than that of the ceramics without $TiB_2$ under the sunlight. The study showed that the removing rate of $NO_2$ was 80% when the mixture rate of Hwangto, Olivine, and $TiB_2$ was 68%, 30% and 2%.