• 제목/요약/키워드: %24CO_2%24 concentration

검색결과 575건 처리시간 0.032초

항공기를 이용한 남해안 지역의 오존 공간분포 조사 (2009년, 여름철) (The Analysis of Spatial Distribution of Ozone in the Southern Coast of Korea using the Aircraft (2009, Summer))

  • 서석준;김소영;이민도;최진수;김수연;이석조;김정수;이강웅
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.12-21
    • /
    • 2012
  • The purpose of this study is to understand distribution of ozone concentration in the south coastal region of Korea by evaluating ozone spatial distribution in the upper air using aircraft. Sampling was carried out from May to August in 2009. The average concentration of ozone in the upper air was ranged from 32.3~90.8 ppb with its maximum concentration of 132 ppb. When it comes to the spatial distribution of ozone, ambient concentration was high in the air, 1,000 m and 500 m above the southern sea near the Gwangyang Bay area and emission sources, respectively. Daily mean concentration of NOy was 6.7~24.2 ppb and that of CO was 0.152~0.487 ppm. In addition, the concentration was appeared to be relatively high in the upper air of industrial regions and the southern seas. Meanwhile, the concentration of both $NO_y$ and CO was high in the upper air of the emission sources regardless of latitude. As for PAN, its daily mean concentration ranged between 0.1 and 0.6 ppb with overall mean concentration of 0.2 ppb. The average concentration of VOCs was 48 ppb, and the concentration of toluene and m,p-Xylene were higher than other components.

일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가 (An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies)

  • 이경민;염정관;이원재;류승훈;박동진;박동욱
    • 한국산업보건학회지
    • /
    • 제24권3호
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

콩고산 코발트 정광으로부터 제조한 매트의 고온고압침출 (High Pressure Leaching of Matte Converted from Cobalt Concentrate from Democratic Republic of the Congo)

  • 김건하;강가희;김수경;손정수;권경중
    • 자원리싸이클링
    • /
    • 제24권4호
    • /
    • pp.32-37
    • /
    • 2015
  • 이차전지 재료 등으로 사용되는 코발트는 콩고 민주공화국 등 일부 국가에 편중되어 있다. 국내 코발트의 안정적인 공급을 위한 해외 코발트광과 코발트 제련 기술의 확보는 필수적이다. 이에 본 실험에서는 콩고산 코발트 정광(Co ~ 8 wt%, Cu ~ 19 wt%, Fe ~ 3 wt%)을 용융환원시켜 얻어지는 합금상에 매트 내 황의 비율을 달리해 만든 2가지 조성의 매트를 제조했으며, 주된 원소는 19 ~ 21wt% Co, 39 ~ 41wt% Cu, 7 ~ 9wt% Fe이다. 매트 분쇄산물을 autoclave를 이용한 고온고압침출법으로 3가지의 영향(산화제 유무, 침출제인 황산 농도, 매트 제조 시 투입되는 황 함량)을 고려해 실험을 진행했다. 먼저 산화제(산소)의 존재는 Co 침출률 향상을 위해 필수적이며 낮은 농도의 황산을 사용하더라도 Co를 전량 침출시킬 수 있다. 둘째 산소 분위기에서 높은 황산농도는 Cu와 Fe의 침출률을 증가시켜 선택적인 Co 침출을 방해한다. 마지막으로 매트 내 황 함량은 Co의 침출률에는 영향이 크지 않음을 알 수 있었다.

$\alpha$-Fe$_2$O$_3$ 박막 센서의 환원성 가스감지특성 (Sensing Properties of $\alpha$-Fe$_2$O$_3$ Thin Film Gas Sensor to Reducing Gases)

  • 이은태;장건익;이덕동
    • 한국세라믹학회지
    • /
    • 제36권5호
    • /
    • pp.465-470
    • /
    • 1999
  • Sensing properties of $\alpha$-Fe2O3 thin film to reducing gases such as CHx and CO were systematically examined after deposition on Al2O3 substrate by PECVD(Plasma Enhanced Chemical Vapor Deposition)technique. Microstructure of deposited $\alpha$-Fe2O3 thin film showed the porous island structure. This specimen was annealed at 450, 550, $650^{\circ}C$ to enhance the gas sensing properties and investigated in terms of CO and C4H10 concentration from 500ppm to 3,000 ppm at operating temperature of 35$0^{\circ}C$ The gas sensitivity(%) to C4H10 measured at the operating temperature of 35$0^{\circ}C$ was 98.24 (highest sensitivity) 69.51 to CO and 2% to CH4 respectviely.

  • PDF

평판형 전극으로 구성된 유전체 배리어 방전 반응기를 이용한 톨루엔 저감 특성 (Removal of Gaseous Toluene using a Plate-type Dielectric Barrier Discharge Reactor)

  • 박재홍;조윤신;윤기영;변정훈;황정호
    • 한국대기환경학회지
    • /
    • 제24권6호
    • /
    • pp.641-648
    • /
    • 2008
  • A plate-type dielectric barrier discharge (DBD) reactor was designed and tested for removal of gaseous toluene. The DBD reactor consisted of 9 parallel plate electrodes, four of which were grounded. An AC voltage of rectangular waveform ($5{\sim}8.5kV$, $60{\sim}1,000Hz$), was applied to the other five electrodes. The gaseous toluene passed through the DBD reactor and its concentration was measured by a real-time gas analyzer. The carbon monoxide (CO) and carbon dioxide ($CO_2$) which were produced by decomposition of toluene in the DBD reactor, were sampled and analyzed by a micro gas chromatography. The maximum toluene removal efficiency was 51.4%.

Effect of seaweed addition on enhanced anaerobic digestion of food waste and sewage sludge

  • Shin, Sang-Ryong;Lee, Mo-Kwon;Im, Seongwon;Kim, Dong-Hoon
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.449-455
    • /
    • 2019
  • To investigate the effect of seaweed (SW) addition on anaerobic co-digestion of food waste (FW) and sewage sludge (SS), batch experiments were conducted at various substrate concentrations (2.5, 5.0, 7.5, and 10.0 g volatile solids (VS)/L) and mixing ratios ((FW or SS):SW = 100:0, 75:25, 50:50, 25:75, and 0:100 on a VS basis). The effect of SW addition on FW digestion was negligible at low substrate concentration, while it was substantial at high substrate concentrations by balancing the rate of acidogenesis and methanogenesis. At 10 g VS/L, $CH_4$ production yield was increased from 103 to $350mL\;CH_4/g$ VS by SW addition (FW:SW = 75:25). On the other hand, SW addition to SS enhanced the digestion performance at all substrate concentrations, by providing easily biodegradable organics, which promoted the hydrolysis of SS. $k_{hyd}$ (hydrolysis constant) value was increased from 0.19 to $0.28d^{-1}$ by SW addition. The calculation showed that the synergistic $CH_4$ production increment by co-digesting with SW accounted for up to 24% and 20% of total amount of $CH_4$ production in digesting FW and SS, respectively.

체외성숙시 중.대란포의 과립막세포 첨가가 배 발달에 미치는 영향 (Effect of Addition of Granulosa Cells for Oocyte Maturation on Cleavage and Development of Bovine IVF Embryos)

  • 공일근;주영국;곽대오;노규진;박충생
    • 한국수정란이식학회지
    • /
    • 제9권1호
    • /
    • pp.1-6
    • /
    • 1994
  • This experiment was investigated the effect of presence of granulosa cells from follicles of different size on bovine oocyte maturation, cleavage and development to late stage. The nuclear and cytoplasmic maturation of oocytes in the IVM-IVF system are critical for subsequent embryo development. Granulosa cells when the co-cultured with oocytes may interact with cumulus-oocytes complexes and influence the development competence of the oocytes. Granulosa cells from medium (2~6 mm) and large(>1O mm) size follicles were recovered by aspiration, washed 3 times by centrifugation at 500 x g for 5 min. and used for co-culture at a concentration of 2~3 x 106 cells/mi. The oocytes were matured in vitro (IVM) for 24 hrs. in TCM-199 supplemented with 35 $\mu$g/ml FSH, 10 $\mu$g/ml LH, 1 $\mu$g/ml estradiol-17$\beta$ and granulosa cells at 39$^{\circ}C$ under 5% $CO_2$ in air. They were fertilized in vitro (IVF) by epididymal spermatozoa treated with heparin for 24 hrs., and then the zygotes were co-cultured in vitro (I VC) with bovine oviductal epithelial cells for 7 to 9 days. The assessment of maturation revealed that Grade J oocytes showed significantly(P

  • PDF

서울시의 대중교통수단내 실내공기질에 대한 연구 (An Investigation of Indoor Air Quality of Public Transportation System in Seoul City)

  • 김윤신;홍승철;전준민
    • 한국환경보건학회지
    • /
    • 제20권1호
    • /
    • pp.28-38
    • /
    • 1994
  • The objective of this study were to measure concentrations of indoor pollutants in public transportation systems to provide importance of indoor air quality in transportation systems to policy makers. Indoor air quality of the pollutants (CO, CO$_2$, PM-10) and environmental sources (temperature, humidity) were measured at subway, seat-type bus, and city-type bus in the Seoul area from April to September 1992. The same pollutants and environmental sources were also measured at selected bus stops and subway stations during October 1991-September 1992. The mean concentrations of indoor pollutants in the public transportation systems were showed 115.5 $\mu$g/m$^3$ in PM-10, 6.8 ppm in CO, and 2167.9 ppm in CO$_2$, respectively. The mean values of PM-10 and CO showed below the U.S. 24 hour standard value of PM-10 and the Korea ambient CO standard, while the mean concentrations of CO$_2$ exceeded the Korea CO$_2$ standard. The highest levels of indoor concentration at public transportation systems were PM-10 of 134.6 $\mu$g/m$^3$ in the subway, CO of 8.9 ppm in the city-type bus, CO$_2$ of 2,511.1ppm in seat-type bus, respectively. The results showed that indoor air quality in bus and subway seemed likely to be affected by number of passengers and outdoor air infiltrated from exhausted gases of automobiles.

  • PDF

한국 활엽수림의 이산화탄소 농도의 연직구조와 저류항 (Vertical Profiles of CO2 Concentrations and CO2 Storage in Temperate Forest in Korea)

  • ;강민석;천정화;김준
    • 한국농림기상학회:학술대회논문집
    • /
    • 한국농림기상학회 2013년도 추계 학술발표논문집
    • /
    • pp.23-24
    • /
    • 2013
  • Micrometeorological fluxes measured over a tall forest in a complex terrain are difficult to interpret. $CO_2$ storage often makes significant contributions to net ecosystem exchange of $CO_2$ (NEE) in early morning and during nighttime due to calm and stable conditions. We measured the above-canopy $CO_2$ flux along with its concentration profiles at eight levels within and above the canopy to evaluate $CO_2$ storage term. Our question is whether or not the $CO_2$ storage term can be estimated accurately from a single level measurement of $CO_2$ concentration in a complex terrain. Our objectives are (1) to document vertical profiles of $CO_2$ concentration and (2) to compare the diurnal and seasonal variations of $CO_2$ storages estimated from single and multi-level $CO_2$ concentration data. Seasonally averaged Diurnal variations of $CO_2$ concentration ranged from 398 to 455 ppm near the forest floor at 0.1 m whereas they ranged from 364 to 395 ppm at 40 m in the atmosphere. The diurnal variation of vertical profiles of $CO_2$ concentration shows very interesting features with season. At all eight levels, diurnal variation of $CO_2$ concentration showed little change in winter. In spring, the diurnal variations of $CO_2$ concentration at 8 levels showed three distinct groups of layers with height: the first layer: 0.1m (near surface), second layer: 1.0 m and 4.0m (below canopy) and the third layer: 7.4m to 40.7 m (near canopy and above). In summer, these three groups of layers were further separated with larger variations whereas such distinction became smaller in fall. The diurnal variation of $CO_2$ concentration in the first three layers near surface always showed higher concentration with larger variability. Typically, $CO_2$ concentration showed peaks in early morning and in the evening. After the evening peak, $CO_2$ concentration gradually increased except for those near the surface (i.e., 0.1, 1.0 and 4.0 m) where the concentrations actually decreased. We suspect that this could be attributed to the drainage flow of $CO_2$ along the hill slope from the headwater to downstream, which is not taken into account for net ecosystem $CO_2$ exchange. In comparison to the results of other studies, the distinct and different vertical structures of $CO_2$ concentrations observed at our site may be due to complex terrain and weak turbulent mixing under calm conditions at the site. The annual mean of diurnal variation of $CO_2$ storage flux from single level ranged from -0.6 to $0.9{\mu}mol\;m^{-2}s^{-1}$ and from multi-level from -1.2 to $1.0{\mu}\;{\mu}mol\;m^{-2}s^{-1}$. When compared against the results from the multi-level concentrations, the storage flux estimated from a single-level concentration was generally adequate except for specific hours near sunrise and sunset. Further details and their implication will be discussed in the presentation.

  • PDF

소 초기배의 체외수정에 관한 연구 (Studies on the In vitro Culture of Early Bovine Embryos)

  • 황우석;권오경;조충호
    • 한국임상수의학회지
    • /
    • 제7권2호
    • /
    • pp.517-519
    • /
    • 1990
  • 소 난소로부터 난자를 채취하여 체외성숙과 체외수정을 실시하였다. 난의 성숙배양을 위한 배양액은 소 태아혈청을 첨가한 TCM 199으로 $CO_2$배양기에서 24시간 배양하였다. 체외수정에는 동결융해정액을 사용하였으며 Caffeine과 Ca Ionophore 처리후 매정에 공하였다. 배양난자중 40%가 Metaphase II까지 성숙하였다. 성숙율에 대한 소 태아혈청의 농도변화와 HEPES 첨가여부의 효과는 없었다. 체외수정율과 분할율의 성적은 각각 23.1%와 14.4%였다.

  • PDF