• 제목/요약/키워드: $x^2-test$

검색결과 4,236건 처리시간 0.067초

소아중환자실 입원 아동의 섬망 발생 관련 요인 (Factors associated with Pediatric Delirium in the Pediatric Intensive Care Unit)

  • 김효진;김동희
    • Child Health Nursing Research
    • /
    • 제25권2호
    • /
    • pp.103-111
    • /
    • 2019
  • Purpose: This study aimed to investigate incidence of delirium in the pediatric intensive care unit (PICU) and to analyze associated risk factors. Methods: The participants were 95 patients, newborn to 18 years, who were admitted to the PICU. The instruments used were the Richmond Agitation Sedation Scale (RASS), and the Cornell Assessment of Pediatric Delirium. Data analysis was performed using the descriptive, $x^2$ test, t-test, and logistic regression analyses. Results: The incidence of delirium in children admitted to the PICU was 42.1%. There were significant differences according to age ($x^2=14.10$, p=.007), admission type ($x^2=7.40$, p=.007), use of physical restraints ($x^2=26.11$, p<.001), RASS score ($x^2=14.80$, p=.001), need for oxygen ($x^2=5.31$, p=.021), use of a mechanical device ($x^2=9.97$, p=.041), feeding ($x^2=7.85$, p=.005), and the presence of familiar objects ($x^2=29.21$, p<.001). Factors associated with the diagnosis of delirium were the use of physical restraint (odds ratio [OR]=13.82, 95% confidence interval [CI]=4.16~45.95, p<.001) and the presence of familiar objects (OR=0.09, 95% CI=0.03~0.30, p=.002). Conclusion: Periodic delirium assessments and intervention should be actively performed. The use of restraints should be minimized if possible. The caregiver should surround the child with familiar objects and ensure a friendly hospital environment that is appropriate for the child.

성관련 강좌가 대학생들의 성지식에 미치는 효과 (Effects of Sexual Knowledge and Consciousness on Sexuality Course on University Students)

  • 김영순;손수경
    • 한국학교보건학회지
    • /
    • 제18권1호
    • /
    • pp.83-93
    • /
    • 2005
  • Purpose: The purpose of this study was to confirm the effects of lectures on sexuality and investigate changes in students' sexual knowledge and consciousness. Method: The subjects in this study were 50 students at K University in Busan, and the research period was from the $8^{th}$ of March to the $7^{th}$ of June 2004. This study was designed to be one-group pretest-posttest. Data were analyzed by frequencies, percentages, means, standard deviations, paired t-test and $x^2$-test using the SPSS 10.0 program. Results: 1. The score of sexual knowledge increased from 14.48 before the education to 15.70 after and the difference was statistically significant (t=3.926, p<.001). 2. Significant differences of sexual consciousness were observed in 'the extent of sexual behavior' ($x^2$=12.584, p<.05), 'the meaning of intercourse' ($x^2$=46.014, p<.001), 'the self attitude of premarital purity' ($x^2$=84.686, p<.001), 'the premarital intercourse' ($x^2$=75.323, p<.001), 'the definition of purity' ($x^2$=23.770, p<.001), 'the general premarital purity attitude' ($x^2$=32.305, p<.001), 'the conception of love, sex and marriage' ($x^2$=38.452, p<.001) and 'the premarital sex experiences' ($x^2$=50.210, p<.001). Conclusions: This study showed that a sexuality course has effects on increasing sexual knowledge and changing the consciousness in university students.

FRC-포스트의 표면처리가 레진시멘트와의 접착력에 미치는 영향 (Effect of surface treatment of FRC-Post on bonding strength to resin cements)

  • 박찬현;박세희;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제36권2호
    • /
    • pp.125-131
    • /
    • 2011
  • 연구목적: Silane 처리가 FRC-포스트와 레진 시멘트 간의 결합강도에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: FRC-포스트로 LuxaPost (DMG)와 Rely-X Fiber Post (3M ESPE)를 사용하였으며 자가 접착 레진 시멘트인 Rely-X Unicem (3M ESPE)과 전통형 레진시멘트인 Rely-X ARC (3M ESPE)와의 Rely-X Ceramic Primer (3M ESPE)를 이용한 표면처리 유무에 따른 결합강도를 push-out test를 실시하여 측정하고 independent samples t-test 및 one-way ANOVA와 Scheffe 사후검정을 95% 유의수준에서 실시하였다. 결과: 실험 결과 Rely-X Fiber Post를 사용한 실험군에서 silane 처리와 관계없이 Rely-X ARC를 적용하였을 때, 다른 실험군들에 비해 높은 결합 강도가 나타났으며 LuxaPost를 사용한 실험군에서 각각의 레진 시멘트에 대해 silane 처리를 하였을 때 시행하지 않은 실험군에 비해 높은 결합 강도가 나타났다. 결론: 이상의 실험 결과로 볼 때 미리 silane 처리된 LuxaPost를 사용하더라도 silane 처리를 시행하는 것이 좋은 것으로 생각된다.

여성의 생리적인 현상에 따른 피부상태와의 상관성 관련 요인에 관한 연구 (The Research for Skin Condition Related with Physiological Phenomenon)

  • 이준철
    • 문화기술의 융합
    • /
    • 제7권2호
    • /
    • pp.207-216
    • /
    • 2021
  • 본 연구는 경남 창원시내에 거주하는 20~40대 여성 315명을 조사대상으로 하여 단순무작위추출(simple landom sampling)하여 설문지조사 방법에 의해 자기 기록식으로 기록하였다. 본 연구는 피부상태에 따른 피부의 유형을 세안 후 30분간 아무것도 바르지 않은 상태에서 뺨부위를 검진법을 통하여 체크하여 지성, 중성, 건성, 지루성으로 구분하여 각 조건들과의 상호작용을 알아보았다. 각 요인들간의 관련성을 알아보기 위해 X2-검정을 실시하였으며, 자료처리는 PC/SAS를 이용하였다. 대상자의 일반적 특성과 피부상태에서 연령, 직장 및 결혼 여부는 통계적으로 유의성이 있었다(p<0.01). 연령이 많을수록 건성으로 진행되는 경향이 있고 직장여성과 기혼여성일 경우 건성의 비율이 높은 편이었다. 스트레스 후 피부반응과 일반적인 특성 및 생리적 현상과의 관련성에서 여드름이 나는 부위와 배변횟수 사이에는 통계적으로 유의한 차이가 있었고, 각 X2-검정의 값은 42.961(P<0.01), 7.345(P<0.05)였다. 피부트러블반응과 여드름 나는 시기와의 사이에는 유의성이 인정되었다(P<0.01).

중단자료를 갖는 이변량 지수 모형에서 $P(X_{1}\;<\;X_{2})$에 대한 검정 (Testing for $P(X_{1}\;<\;X_{2})$ in Bivariate Exponential Model with Censored Data)

  • 박진표;조장식
    • Journal of the Korean Data and Information Science Society
    • /
    • 제8권2호
    • /
    • pp.143-152
    • /
    • 1997
  • 본 논문에서는, Marshall-Olkin의 이변량 지수모형을 따르는 두개의 부품으로 이루어진 시스템에서 두 부품의 수명 $(X_{1},\;X_{2}$들이 이변량 1종 중단된 자료로 관찰되는 경우, $P(X_{1}\;<\;X_{2})$에 대한 최우추정량을 구하고 근사적 정 규성을 밝힌다. 그리고 그 추정량을 기초로 $P(X_{1}\;<\;X_{2})$에 대한 근사적 검정법을 제안하고, 몬테칼로 모의실험을 통하여 여러가지 상황에서 제안된 추정량의 근사적 검정력을 계산하여 비교하였다.

  • PDF

On Two-Piece Double Exponential Distribution

  • Lingappaiah, G.S.
    • Journal of the Korean Statistical Society
    • /
    • 제17권1호
    • /
    • pp.46-55
    • /
    • 1988
  • Two-piece double exponential distribution (TPDE) with one piece $(X \leq 0)$ having the scale parameter $\theta_1$ while the other piece (X>0) having $\theta_2$ is considered here. Distribution of the sum of n-independent variables from such a distribution is obtained. Special cases of this distribution are also treated. Next, distribution of the ratio of two independent (TPDE) variables is derived. As an extension, distribution of $x_1/x_2x_3$ is expressed terms of hypergeometric functions. A small table gives the power of the test regarding double exponential against (TPDE).

  • PDF

습식표면처리 및 열 사이클에 따른 Cu/SiNx 계면접착에너지 평가 및 분석 (Effects of Wet Chemical Treatment and Thermal Cycle Conditions on the Interfacial Adhesion Energy of Cu/SiNx thin Film Interfaces)

  • 정민수;김정규;강희오;황욱중;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제21권1호
    • /
    • pp.45-50
    • /
    • 2014
  • 반도체 미세구리배선 적용을 위하여 구리배선의 습식 표면처리 및 열 사이클에 따른 구리 박막과 실리콘질화막 도포층 사이의 계면접착에너지를 4점굽힘시험을 통해 정량적으로 평가하였다. 구리배선을 화학적 기계적 연마한 후 습식 표면처리를 통하여 구리 박막과 실리콘질화막의 계면접착에너지는 $10.57J/m^2$에서 $14.87J/m^2$로 증가하였다. $-45{\sim}175^{\circ}C$범위에서 250사이클 후, 표면처리를 하지 않은 시편의 계면접착에너지는 $5.64J/m^2$으로, 표면처리를 한 시편은 $7.34J/m^2$으로 감소하였으며, 모든 시편의 박리계면은 구리 박막과 실리콘질화막 계면으로 확인되었다. X-선 광전자 분광법으로 계면 결합 상태를 분석한 결과, 화학적 기계적 연마 공정 후 구리배선의 표면 산화물이 습식표면처리에 의해 효과적으로 제거된 것을 확인하였다. 또한, 열 사이클 처리동안, 구리 박막과 실리콘질화막의 큰 열 팽창 계수 차이로 인한 열응력으로 인하여 구리 박막과 실리콘질화막 계면이 취약해지고, 계면을 통한 산소유입에 따른 구리 산화층이 증가하여 계면접착에너지가 저하된 것으로 판단된다.

Ti 및 Mo 첨가에 따른 치과 CAD/CAM용 Ni-Cr 및 Co-Cr합금의 표면분석 (Surface Analysis of Ni-Cr and Co-Cr Alloys with Addition of Ti and Mo for Dental CAD/CAM Use)

  • 문대선;최한철
    • 한국표면공학회지
    • /
    • 제51권3호
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, surface analysis of Ni-Cr and Co-Cr alloys with addition of Ti and Mo for dental CAD/CAM use has been researched experimentally. The surface characteristics of the alloys were examined by Vickers hardness test, bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction spectroscopy. The shrinkage of the sintered Ni-Cr alloy alloy was slightly larger than that of Ni-Cr-Ti alloy, and larger than Co-Cr alloy. Also, the addition of Mo showed a tendency to decrease shrinkage somewhat. From the result of XRD analysis, NiCr, $Ni_3Cr$ and $Ni_3Ti$ were observed in the sintered Ni-13Cr-xTi and Ni-13Cr-xMo alloys. In addition, ${\sigma}-CrCo$, $Co_2Mo_3$ and $TiCo_2$ were formed in the sintered Co-Cr-xTi and Co-Cr-xMo alloys. Surface hardness of Ti and Mo added alloy was higher than those of Ni-Cr and Co-Cr alloy. The bond strength between sintered alloy and porcelain was $16.1kgf/mm^2$ for Ni-13Cr alloy, $17.8kgf/mm^2$ for Ni-13Cr-5Ti alloy, and $8.2kgf/mm^2$ for Ni-13Cr-10Ti alloy, respectively.

Antibacterial property and characterization of CuSn thin films deposited by RF magnetron co-sputtering method

  • 강유진;박주연;김동우;김학준;강용철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.360.2-360.2
    • /
    • 2016
  • CuSn thin films were fabricated by rf magnetron co-sputtering method on the Si(100) substrate for evaluation of the antibacterial effect. The co-sputtering process was performed with different rf powers and sputtering times to regulate the thickness of the films and relative atomic ratio of Cu to Sn. The physicochemical properties of the CuSn thin films were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), X-ray induced Auger electron spectroscopy (XAES), Optical microscope (OM), 4-point probe, and antibacterial test. An antibacterial test was conducted with Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) as changing contact times between CuSn fillms and bacteria suspension. We compared to the crystalline structures of films before sterilization and after sterilization by XRD measurement. The changes of oxidation states of Cu and Sn and the chemical environment of films before and after antibacterial test were investigated with high resolution XPS spectra in the regions of Cu 2p, Cu LMM, and Sn 3d. After antibacterial test, the morphology of the films was checked with an OM images. The electrical properties of the CuSn films such as surface resistance and conductivity were measured by using 4-point probe.

  • PDF

경북 지역 의원급의 X선 발생장치 정도관리 실태 (Medical Clinics' quality Management of X-ray Units in Gyeongbuk Area)

  • 박정규
    • 한국콘텐츠학회논문지
    • /
    • 제10권9호
    • /
    • pp.267-275
    • /
    • 2010
  • X선 발생장치의 정도관리는 의료기관의 설립형태에 따라 가장 큰 차이가 있으며, 장치의 보유율은 1차 의료기관에서 가장 많이 보유한 반면 정도관리에 대한 인식과 관리는 소홀하다 할 수 있다. 본 연구에서는 2010년 1월 4일부터 2010년 9월 3일까지 경북 지역을 4개의 권역으로 나누고, 각 시별로 4곳을 임으로 선정하였다. 전체 16곳에 있는 의원급 의료기관 중 10년 이상 된 X선 발생장치를 보유한 8곳과 10년 이하의 X선 발생장치를 보유한 8곳를 그 대상으로 하였으며, 정도관리의 필수 항목 5가지를 시험하였다. 접지 설비 확인시험에서는 10년 이상 된 X선 장치를 보유한 한 곳이 별도의 접지선을 구비하지 않았으며(6.25%), 외장 누설전류시험에서는 모두 적합 하였다. 조사선량 재현성 시험에서는 10년 이상 된 X선 발생장치를 보유한 4곳(25%)과 10년 이하의 X선 발생장치를 보유한 1(6.25%)곳이 부적합 하였다. 관전압의 정확도 시험에서는 10년 이상 된 X선 발생장치를 보유한 5곳(31.25%)과 10년 이하의 X선 장치를 보유한 2곳(12.5%)이 부적합 하였다. 관전류와 관전류량 시험에서는 10년 이상 된 X선 장치를 보유한 3곳(18.75%)과 10년 이하의 X선 장치를 보유한 1곳(6.25%)이 부적합 하였다. 본 연구 결과 10년 이하의 X선 발생장치를 보유한 의원급 의료기관 보다 10년 이상 된 의원급 의료기관의 X선 발생장치의 정도 관리 실태는 심각한 수준 이였다. 검사 결과를 바탕으로 행정적, 기술적인 조치들이 신속하게 이루어져야 할 것이다. 또한 의원급의 사업주나 장치 담당자들의 의식 전환이 필요 하며 그러기 위해서는 오래된 장비이거나 자주 사용하지 않는 장비일수록 정기검사주기를 1~2년 단위로 개정하여야 하고, 정기적인 정도 관리 교육 프로그램을 실시하여야 할 것으로 사료된다.