A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances (부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 -)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

A Study of Pulmonary Function and HRCT Findings in Asthma Patients According to the Response after Treatment (기관지 천식 환자에서 치료 반응의 차이에 따른 폐 기능 및 고해상 CT 소견의 고찰)

  • NamKung, Eun-Kyung;Kim, Kyung-Ho;Kim, Ki-Up;Uh, Soo-Taek;Kim, Yong-Hoon;Park, Choon-Sik;Park, Jae-Sung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1051-1062
    • /
    • 1997
  • Background : In asthma, airway obstruction is usually reversible, either spontaneously or with treatment. However, the responses to treatment are variable and some patients show an irreversible component of airflow obstruction. This may be associated with structural changes in the airway. To assess the relationship between the difference in airway reversibility and structural changes, we evaluated the HRCT findings and pulmonary function test. Methods : We studied 40 asthmatic subjects who had had acute exacerbation of symptoms and had showed normal chest X-ray findings. They had monitered PEFR daily, and had performed PFT and HRCT within three days after initiation of treatment. According to serial PEFR, they were grouped into 3 categories (Group 0 ; initial PEFR was within normal limit, Group 1 ; revealed increment of 30% in PEFR within 3 days after initiation of treatment, Group 2 ; revealed within 2 weeks) and then grouped again into 4 (Group 0, Group 3 ; reached to normal value of PEFR within 3 days after initiation of treatment, Group 4 ; within 2 weeks, Group 5 ; not within 2 weeks). Results : (1) Age in Group 0 was significantly lower than other groups(p<0.05), but there was no significance in other groups. (2) Duration of asthma in Group 2 was significantly longer than Group 0, 1(p<0.05). (3) FVC(%) and FEV1(%) were significantly decreased with delayed response to the treatment (p<0.05). (4) $FEV_1$/FVC(%) in Group 1, 2 were significantly lower than Group 0(p<0.05). $FEV_1$/FVC(%) in Group 5 was significantly lower than Group 0,3,4 (p<0.05). (5) Air trapping was increased significantly with delayed response to the treatment (p<0.05). (6) Mucus impaction in Group 0 was significantly larger than Group 1,2 (p<0.05). $FEV_1$/FVC(%) in Group 0,4,5 were significantly larger than Group 3 (p<0.05). Conclusion : Difference in reversibility of airway obstruction was associated with age, duration of asthma and severity of initial airflow obstruction There was no definite difference in HRCT findings in asthma.

  • PDF

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

Study of the Impact of Light Through the Vitamin $B_{12}$/Folate Inspection (Vitamin $B_{12}$/Folate 검사 시 빛의 영향에 대한 고찰)

  • Cho, Eun Bit;Pack, Song Ran;Kim, Whe Jung;Kim, Seong Ho;Yoo, Seon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.162-166
    • /
    • 2012
  • Purpose : Vitamin $B_{12}$ and Folate are for anemia work-up which is well known for its sensitivity of light; the screening manual also specifies to be careful with light conditions. According to this, our laboratory minimized the exposure of light when inspecting the Vitamin $B_{12}$ and Folate, but the exposure cannot be wholly blocked due to other various factors such as when conducting specimen segregation. Thus, this inspection is to identify to what extent light can influence and whether the exclusion of light is mandatory during the Vitamin $B_{12}$/Folate test. Materials and Methods : We have conducted two experiments of identifying the extent of light's influence when conducting the Vitamin $B_{12}$/Folate test and also when specimens are under preservation. These experiments were progressed with various concentrations of patients' specimens which were requested to our hospital in March 2012. The first experiment is to verify the results on Vitamin $B_{12}$/Folate dependent on light exposure during the experiment. In the process, we have compared the results of light exposure/exclusion during the incubation process after the reagent division. The second experiment is about the impact of light exposure on the results on Vitamin $B_{12}$/Folate during the preservation. For 1, 2, 7 days the light on the specimen were wholly blocked and were preserved under $-15^{\circ}C$ temperature refrigeration. Then, we compared the results of light-excluded specimen and the exposed one. Results : When conducting first experiment, there were no noticeable changes in the Standard and specimen's cpm, but for Vitamin $B_{12}$, the average result of specimen exposed to light increased 7.8% compare to that of excluded one's. Furthermore, in the significant level 0.05, the significance probability or the p-value was 0.251 which means it has no impact. For Folate, the result being exposed to light decreased 5.4%, the significance probability was 0.033 which means it has little impact. For the second preservation, the result was dependent on the light exposure. The first day of preservation of Vitamin $B_{12}$, the clinical material exposed to light was 11.6%, second day clinical material exposed to light was 10.8%, seventh day clinical material exposed to light increased 3.8%, the significance probability of the $1^{st}$, $2^{nd}$, $7^{th}$ day is 0.372, 0.033, 0.144 respectively, and which indicates that the $1^{st}$ and $7^{th}$ day seems to have no impact. For Folate's case, the clinical material exposed to light has increased 1.4% but hardly had impact, $2^{nd}$ day clinical material being exposed to light was 6.1%, $7^{Th}$ day clinical material being exposed to light decreased 5.2%. The significance probability of Folate on the $1^{st}$, $2^{nd}$, $7^{th}$ day is 0.378, 0.037, 0.217 respectively, and the $1^{st}$ day and the $7^{th}$ day seems to have no impact. Conclusion : After scrutinizing the impact of light exposure/exclusion, Vitamin $B_{12}$ has no impact, while Folate seems to have no noticeable influence but light exclusion is recommended due to its significance probability of 0.033 when conducting experiment. During the preservation, the $2^{nd}$ day result depend on the light exclusion seems to have impact or influence. However, to consider the complication of the experimental process, the experiment including technical errors is predictable. Hence, it is likely to have no impact of light. Nevertheless, it is recommendable to exclude the light during the long preservation as per the significance probability (p-value) of $1^{st}$ and $7^{th}$ day has been diminished.

  • PDF

Combinations of Paraquat and Oxyfluorfen for Control of Orchard Weeds (과수원(果樹園) 제초(除草)를 위한 Paraquat 와 Oxyfluorfen 조합처리(組合處理) 효과(效果)에 관한 연구(硏究))

  • Kwon, S.L.;Guh, J.O.;Cho, Y.W.
    • Korean Journal of Weed Science
    • /
    • v.3 no.2
    • /
    • pp.208-222
    • /
    • 1983
  • To control ideally the weeds in orchards and systematize the utility of herbicides, the mixing effect of oxyfluorfen and paraquat was evaluated. Combinations of oxyfluorfen with paraquat were increased the control efficacies at any treatment without giving damage to fruit trees and appeared a synergism. The control effects were reduced from 80-90% to 40-60% as the time advanced. However, the relative synergistic index was higher at 60 days after treatment in preemergence treatment and at 90 days after treatment in early and late postemergence treatment, respectively. Also the index was relatively higher at lower dosage of both herbicides.

  • PDF

Determinants of Decision Making in Employment Among the Non-Working Elderly Persons (도시지역 미취업 노인들의 취업의사 결정요인에 관한 연구)

  • Hur, Jun-Soo
    • Korean Journal of Social Welfare
    • /
    • v.58 no.1
    • /
    • pp.291-318
    • /
    • 2006
  • There were many studies conducted on economical aspects of employment among the elderly in national level, however, very few studies examined social and psychological aspects of senior employment and employment preferences of the elderly persons. The purposes of this study were to examine major determinants of decision making in employment, and to explore some relationships among decision making of employment, socio-economic factors, health and psycho-social factors, and labor and economical factors among non-working elderly persons in the community. In all, two-hundred-twenty elderly persons were interviewed and one-hundred-ninety-four were analyzed in this study. The descriptive statistics, analysis of variance, correlation analysis, and logistic regression were used for the data analysis in this study. The study found that the respondent's sex, ages, education, numbers of children, physical health, ADL, self-efficacy, economical stress, numbers of years in labor, asset of real estate, family allowances, and the benefit levels of pension were major determinants of decision making in employment among non-working elderly persons. Finally, some implications were discussed for developing effective senior employment in national policy, job related services, and welfare programs of the elderly persons for the successful aging.

  • PDF

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Preference of Neck-tie Pattern Designs according to Male Consumers' Fashion Life Style (남성소비자들의 패션라이프스타일에 따른 넥타이 문양디자인 선호)

  • Song, Ha-Young;Goo, Yong-Lim;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.11 no.4
    • /
    • pp.489-500
    • /
    • 2008
  • The purpose of this study was to determine the preference and purchasing intention on necktie pattern designs according to male consumers' fashion lift style. Written questionnaires were handed out to 300 male consumers of the 20-40 years old in Seoul and surroundings, who were accessed by a convenience sampling method. The questionnaires were to classify male consumer groups according to the fashion life style, to examine characteristics, needs and wants of each group. The stimuli of 8 kinds of necktie patterns in black & white, and the semantic differential scale were applied to evaluate the preference and purchasing intention on necktie pattern design. A total of 265 samples were analyzed by factor analysis, cluster analysis, ANOVA, crosstabs and $X^2$-test through SPSS package program. Six factors in their fashion life style were extracted as follows: those were 'fashion-oriented', 'traditional conservative', 'brand-flaunting', 'personality-oriented', 'practicality-oriented' and 'unconcerned' life style. With these life style sub-dimensions, male consumers were segmented into five groups: these groups were 'strong personal seekers', 'practical brand seekers', 'traditional personal seekers', 'active fashion seekers', 'unconcerned group'. Each of these groups of male consumers showed significant differences in the preference and purchasing Intension of necktie pattern designs according to their fashion life style.

  • PDF

Evaluation for Biomechanical Effects of Metatarsal Pad and Insole on Gait (보행 중 중족골 패드와 인솔의 생체역학적 영향성 평가)

  • Choi, Jung-Kyu;Park, In-Sik;Lee, Hong-Jae;Won, Yong-Gwan;Kim, Jung-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.487-494
    • /
    • 2011
  • The purpose of this study was to evaluate the effects of metatarsal pad (MP) compared with barefoot and MP with using different insoles on gait. 15 healthy females who had no history of injury in the lower extremity with an average age of 22.7 year(SD=1.35), height of 160 cm(SD=3.4), weight of 48.8 kg(SD=5.52) and average foot size of 232.5 mm(SD=6.8) participated in this study as the subjects. The subjects walked on a treadmill under four different experimental conditions: 1) walking with barefoot, 2) walking wearing MP 3) walking wearing a soft insole with MP(SIMP), 4) walking wearing a rigid insole with MP(HIMP). During walking, foot pressure data such as force, contacting area, peak pressure, and mean pressure was collected using Pedar-X System(Novel Gmbh, Germany) and EMG activity of lower limb muscles such as tibialis anterior(TA), lateral gastrocnemius(LG), rectus femoris(RF), and musculus biceps femoris(MBF) was gathered using Delsys EMG Work System(Delsys, USA). Collected data was then analyzed using paired t-test in order to investigate the effects of each of experimental conditions. As a result of the analysis, when MP and HIMP were equipped, overall contacting area was increased while the force, peak pressure and the mean pressure were decreased. Especially, when the SIMP was equipped, every data were significantly decreased. In case of EMG, wearing MP, SIMP and HIMP made three muscles(TA, LG, RF)'s activity decrease. A result of the analysis will be able to apply for manufacturing functional shoes, diabetes shoes, senior shoes and lower extremity orthosis. Significance of the study due to a metatarsal pad and the insole is to analyze the changes in muscle strength.

The relationship between EEG prefrontal asymmetry and emotion following exercise deprivation in people with exercise addiction (운동박탈에 따른 운동중독자의 정서적 변화에 대한 뇌 생리심리적 접근: EEG 대뇌반구비대칭활성화 차이지표 적용 연구)

  • Kim, Sung-Woon;Kim, Han-Cheol
    • Journal of Digital Convergence
    • /
    • v.14 no.10
    • /
    • pp.521-534
    • /
    • 2016
  • This study examined the neurophysiological mechanisms of exercise deprivation by investigating differences in emotion changes and EEG prefrontal asymmetry in relation with exercise. Twenty male undergraduate university students in the 23-27 age range, amateur marathon runners, were selected as the participants (n=20) and divided into one of two experimental conditions at random: (1) exercise deprivation group (n=10), and (2) non-exercise deprivation group (n=10). PANAS-X measurement and EEG measurement from F3 and F4 scalp sites were performed at pre-test, 3 days after exercise deprivation, and 5 days after exercise deprivation. Results revealed that participants of EDG significantly decreased a positive effect after exercise deprivation on EEG and self-reported measures, and showed an increased negative effect after exercise deprivation on self-reported measures. In contrast, participants of NEDG significantly increased positive feelings after exercise and showed a decreased negative effect after exercise on EEG and self-reported measures. Our results showed that exercise deprivation increasing negative emotion after exercise deprivation. The findings of this study suggest that EEG frontal brain asymmetry can be used as diagnosing method for exercise deprivation.