• Title/Summary/Keyword: $Vs^{30}$

Search Result 1,662, Processing Time 0.025 seconds

Clinical Outcome after Breast Conserving Surgery and Radiation Therapy for Early Breast Cancer (초기 유방암의 유방 보존수술 후 방사선 치료 결과)

  • Cho, Heung-Lae;Kim, Cheol-Jin;Park, Sung-Kwang;Oh, Min-Kyung;Lee, Jin-Yong;Ahn, Ki-Jung
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.204-212
    • /
    • 2008
  • Purpose: This study was performed to evaluate the disease-free survival and risk factors of recurrence in early breast cancer patients who have undergone breast conserving surgery and radiation therapy. Materials and Methods: From March 1997 to December 2002, 77 breast cancer patients who underwent breast conserving surgery and radiation therapy were reviewed retrospectively. The median follow-up time was 58.4 months (range $43.8{\sim}129.4$ months) and the mean subject age was 41 years. The frequency distribution of the different T stages, based on the tumor characteristics was 38 (49.3%) for T1, 28 (36.3%) for T2, 3 for T3, 7 for T is and 1 for an unidentified sized tumor. In addition, 52 patients (67.5%) did not have axillary lymph metastasis, whereas 14 patients (18.1%) had $1{\sim}3$ lymph node metastases and 3 (0.03%) had more than 4 lymph node metastases. The resection margin was negative in 59 patients, close (${\leq}2\;mm$) in 15, and positive in 4. All patients received radiation therapy at the intact breast using tangential fields with a subsequent electron beam boost to the tumor bed at a total dose ranging from 59.4 Gy to 66.4 Gy. Patients with more than four positive axillary lymph nodes received radiation therapy ($41.4{\sim}60.4\;Gy$) at the axillary and supraclavicular area. Chemotherapy was administered in 59 patients and tamoxifen or fareston was administered in 29 patients. Results: The 5 year overall survival and disease-free survival rates were 98.08% and 93.49%, respectively. Of the 77 patients, a total of 4 relapses (5.2%), including 1 isolated supraclavicular relapse, 1 supraclavicular relapse with synchronous multiple distant relapses, and 2 distant relapses were observed. No cases of local breast relapses were observed. Lymph node metastasis or number of metastatic lymph nodes was not found to be statistically related with a relapse (p=0.3289) nor disease-free survival (p=0.1430). Patients with positive margins had a significantly shorter disease-free survival period (p<0.0001) and higher relapse rates (p=0.0507). However, patients with close margins were at equal risk of relapse and disease-free survival as with negative margins (p=1.000). Patients younger than 40 years of age had higher relapse rates (9.3% vs. 0%) and lower disease-free survival periods, but the difference was not statistically significant (p=0.1255). The relapse rates for patients with tumors was 14% for tumor stage T2, compared to 0% for tumor stage T1 tumors (p=0.0284). A univariate analysis found that disease-free survival and relapse rates, T stage, positive resection margin and mutation of p53 were significant factors for clinical outcome. Conclusion: The results of this study have shown that breast conservation surgery and radiation therapy in early breast cancer patients has proven to be a safe treatment modality with a low relapse rate and high disease-free survival rate. The patients with a positive margin, T2 stage, and mutation of p53 are associated with statistically higher relapse rates and lower disease-free survival.

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF