• Title/Summary/Keyword: $V_s$

Search Result 14,728, Processing Time 0.042 seconds

Optical Properties of SnS2 Single Crystals

  • Lee Choong-Il
    • Korean Journal of Materials Research
    • /
    • v.15 no.3
    • /
    • pp.195-201
    • /
    • 2005
  • The $SnS_2,\;SnS_2:Cd$, and $SnS_2:Sb$ single crystals were grown by the chemical transport reaction method. The indirect optical energy band gap was found to be 2.348, 2.345, and 2.343 eV for the $SnS_2,\;SnS_2:Cd$, and $SnS_2:Sb$ single crystals, at 6 K respectively. The direct optical energy band gap was found to be 2.511, 2.505, and 2.503 eV f3r the $SnS_2,\;SnS_2:Cd$, and $SnS_2:Sb$ single crystals, at 6 K respectively The temperature dependence of the optical energy band gap was well fitted by the Varshni equation. Two photoluminescence emission peaks with the peak energy of 2.214 and 1.792 eV for $SnS_2$, 2.214 and 1.837 eV for $SnS_2:Cd$, and 2.214 and 1.818 eV the $SnS_2:Sb$ were observed. The emission peaks were described as originating from the donor-acceptor pair recombinations.

Properties of Photoluminescience for AgInS2/GaAs Epilayer Grown by Hot Wall Epitaxy

  • Lee, Sang-Youl;Hong, Kwang-Joon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.2
    • /
    • pp.50-54
    • /
    • 2004
  • The AgInS$_2$epilayers with chalcopyrite structure grown by using a hot-wall epitaxy (HWE) method have been confirmed to be a high quality crystal. From the optical absorption measurement, the temperature dependence of the energy band gap on the AgInS$_2$/GaAs was derived as the Varshni's relation of E$\_$g/(T) = 2.1365 eV - (9.89${\times}$10$\^$-3/ eV/K) T$^2$/(2930+T eV). After the as-grown AgInS$_2$/GaAs was annealed in Ag-, S-. and In-atmosphere, the origin of point defects of the AgInS$_2$/GaAs has been investigated by using the photoluminescence (PL) at 10 K. The native defects of $V_{Ag}$, $V_s$, $Ag_{int}$, and $S_{int}$ obtained from PL measurement were classified to donors or accepters type. And, we concluded that the heat-treatment in the S- atmosphere converted the AgInS$_2$/GaAs to optical p-type. Also, we confirmed that the In in the AgInS$_2$/GaAs did not form the native defects because the In in AgInS$_2$did exist as the form of stable bonds.

Liquefaction Assessment Variations with Regard to the Geotechnical Information Considering of Critical Depth for Liquefaction (액상화 취약심도를 고려한 지반정보에 따른 액상화 평가의 변화)

  • Song, Sungwan;Kim, Hansaem;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.6
    • /
    • pp.5-11
    • /
    • 2020
  • Recently, due to the liquefaction caused by earthquakes in Pohang and surrounding areas, the importance of researches on the liquefaction assessment has increased. The possibility of liquefaction can be assessed using the geotechnical information. The cyclic resistance ratio (CRR) value used in the assessment of liquefaction can be determined by using the SPT-N values or shear wave velocity, Vs value. A study was conducted to compare the accuracy of the liquefaction assessment using these two types of geotechnical information, and concluded that the results using SPT-N values are more accurate than those using Vs values. The previous study speculated that the used Vs value was measured at a depth of 12 m uniformly without considering the critical depth of liquefaction. Therefore, 10 empirical equations that convert SPT-N values measured at critical depth of liquefaction into Vs values to confirm the validity of geotechnical information measured at 12 m points uniformly are used to assess the liquefaction possibility and the results were compared with the actual liquefaction results to confirm the accuracy. As a result, 7 out of 10 cases considering critical depth for liquefaction show higher accuracy than those not considered.

Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$ (한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계)

  • Chung, Kwan-Ogg;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

A NEW VERTEX-COLORING EDGE-WEIGHTING OF COMPLETE GRAPHS

  • Farahani, Mohammad Reza
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.1_2
    • /
    • pp.1-6
    • /
    • 2014
  • Let G = (V ; E) be a simple undirected graph without loops and multiple edges, the vertex and edge sets of it are represented by V = V (G) and E = E(G), respectively. A weighting w of the edges of a graph G induces a coloring of the vertices of G where the color of vertex v, denoted $S_v:={\Sigma}_{e{\ni}v}\;w(e)$. A k-edge-weighting of a graph G is an assignment of an integer weight, w(e) ${\in}${1,2,...,k} to each edge e, such that two vertex-color $S_v$, $S_u$ be distinct for every edge uv. In this paper we determine an exact 3-edge-weighting of complete graphs $k_{3q+1}\;{\forall}_q\;{\in}\;{\mathbb{N}}$. Several open questions are also included.

Consideration on the trial operation of 765kV substation (765kV 변전소 시운전에 관한 고찰)

  • Byun, Gang;Jung, S.H.;Park, K.W.;Lee, S.M.;Choi, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.29-31
    • /
    • 2002
  • Purpose of the 765kV trial operation conducted for the first time in our country are performance verification of domestic developed equipment(765kV M.Tr, GIS,etc) and extraction of problem in advance to commercial operation and cultivation of operation ability. The trial operation of 765kV substation was finished successfully under the positive supports of institutes. manufactures. and constructers. It is expected that extraction of problems in advance and accumulation of operation techniques through the trial operation of 765kV substation will be contributed largly to the realization of the without a hitch operation of 765kV system.

  • PDF

III-V/Si Optical Communication Laser Diode Technology (광통신 III-V/Si 레이저 다이오드 기술 동향)

  • Kim, H.S.;Kim, D.J.;Kim, D.C.;Ko, Y.H.;Kim, K.J.;An, S.M.;Han, W.S.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.3
    • /
    • pp.23-33
    • /
    • 2021
  • Two main technologies of III-V/Si laser diode for optical communication, direct epitaxial growth, and wafer bonding were studied. Until now, the wafer bonding has been vigorously studied and seems promising for the ideal III-V/Si laser. However, the wafer bonding process is still complicated and has a limit of mass production. The development of a concise and innovative integration method for silicon photonics is urgent. In the future, the demand for high-speed data processing and energy saving, as well as ultra-high density integration, will increase. Therefore, the study for the hetero-junction, which is that the III-V compound semiconductor is directly grown on Si semiconductor can overcome the current limitations and may be the goal for the ideal III-V/Si laser diode.

Patho-anatomy and treatment of complex congenital cardiovascular anomalies associated with left superior vena cava: report of 16 cases (좌상공정맥을 합병한 복합심혈관기형의 병리해부와 수술 성적: 16례 보)

  • 정원상
    • Journal of Chest Surgery
    • /
    • v.17 no.2
    • /
    • pp.177-183
    • /
    • 1984
  • From July 1975 to March 1984, 16 patients of complex congenital cardiovascular anomalies associated with left superior vena cava were seen at Han-Yang University Hospital. The age of patients was ranged from 2 to 15 years-old. The distribution of Sex was 7 patients in male, 9 patients in female. Persistent Left Superior Vena Cava [L.S.V.C.] was classified according to the proximal connection of L.S.V.C. into 3 groups. Group I which L.S.V.C. connected to coronary venous sinus was in 9 patients, Group II which L.S.V.C. connected to Left atrium was in 5 patients, Group III which L.S.V.C. hemodynamically connected to right atrium was in 2 patients. Pathoanatomical findings of complex congenital cardiovascular anomalies associated with L.S.V.C. in 16 cases were generally show unsystematic irregularity. In group I, A.S.D. were only in 3 cases, but in highest incidence and in group III, all two cases were supracardiac type of total anomalous drainage of pulmonary veins. Post-operatively, 3 patients among 14 patients of total correction, were died immediately, 1 patient of palliative shunt operation was died after 2 and half years, and Follow-up results of other remaining patients were excellent.

  • PDF

Experimental analysis of rocking shallow foundation on cohesive sand

  • Moosavian, S.M. Hadi;Ghalandarzadeh, Abbas;Hosseini, Abdollah
    • Earthquakes and Structures
    • /
    • v.22 no.6
    • /
    • pp.597-608
    • /
    • 2022
  • One of the most important parameters affecting nonlinearsoil-structure interaction, especially rocking foundation, is the vertical factor of safety (F.Sv). In this research, the effect of F.Sv on the behavior of rocking foundations was experimentally investigated. A set of slow, cyclic, horizontal loading tests was conducted on elastic SDOF structures with different shallow foundations. Vertical bearing capacity tests also were conducted to determine the F.Sv more precisely. Furthermore, 10% silt was mixed with the dry sand at a 5% moisture content to reach the minimum apparent cohesion. The results of the vertical bearing capacity tests showed that the bearing capacity coefficients (Nc and Nγ) were influenced by the scaling effect. The results of horizontal cyclic loading tests showed that the trend of increase in capacity was substantially related to the source of nonlinearity and it varied by changing F.Sv. Stiffness degradation was found to occur in the final cycles of loading. The results indicated that the moment capacity and damping ratio of the system in models with lower F.Sv values depended on soil specifications such cohesiveness or non-cohesiveness and were not just a function of F.Sv.