• Title/Summary/Keyword: $V_2I$

Search Result 5,368, Processing Time 0.036 seconds

Bacterial Flora of East China Sea and Yosu Coastal Sea Areas 2. Horizontal Distributions of Bacteria Isolated from The Sea Area (여수 연안 및 동중국해의 세균상 2. 분리균의 수평분포)

  • SHIN Suk-U;JUNG Kyoo-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • The results identified for bacterial flora 174, Vibrio spp.132, and coliform group 183 strains isolated from the areas of last China Sea and Yosu coastal sea during from August 6th. to 14th. 1992 were as follow: 40 strains among the 74 strains of bacteria flora isolated from fast China sea area were Pseudomonas spp.$(54\%)$ and 60 strains among the 100 strains isolated from Yosu sea area were Enterobacteriaceae $(60\%)$. Four strains were Vibrio alginoliticus and one strain of V, parahaemolyticus among 5 strains of genus Vibrio isolated from last China Sea. While 54 strains were V. alginolyticus $(43\%)$ and V, parahaemolyticus $(17\%)$ among 127 strains genus Vibrio isolated from Yosu coastal sea area. Seventy nine strains among the 156 strains of coliform group isolated from Vosu sea area were Escherichia coli I $(51\%)$ and each one strain Citrobacter freundii I and II. 3 strains among 27 strains isolated from last China sea area were E. coli$(11\%)$ and 1 strain of C. freundii I. Coliform group was grouped into 16 types by IMViC system, $44^{\circ}C$, gelatin liquefaction test.

  • PDF

A Design and Implementation of 32-bit RISC-V RV32IM Pipelined Processor in Embedded Systems (임베디드 환경에서의 32-bit RISC-V RV32IM 파이프라인 프로세서 설계 및 구현)

  • Subin Park;Yongwoo Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.81-86
    • /
    • 2023
  • Recently, demand for embedded systems requiring low power and high specifications has been increasing, and RISC-V processors are being widely applied. RISC-V, a RISC-based open instruction set architecture (ISA), has been developed and researched by UC Berkeley and other researchers since 2010. RV32I ISA is sufficient to support integer operations such as addition and subtraction instructions, but M-extension should be defined for multiplication and division instructions. This paper proposes an RV32I, RV32IM processor, and indicates benchmark performance scores compared to an existing processor. Additionally, A non-stalling method was proposed to support a 2-stage pipelined DSP multiplier to the 5-stage pipelined RV32IM processor. Proposed RV32I and RV32IM processors satisfied a maximum operating frequency of 50 MHz on Artix-7 FPGA. The performance of the proposed processors was verified using benchmark programs from Dhrystone and Coremark. As a result, the Coremark benchmark results of the proposed processor showed that it outperformed the existing RV32IM processor by 23.91%.

  • PDF

Performance Evaluation of Component Detectors of Double-scattering Compton Camera (이중 산란형 컴프턴 카메라 구성 검출기 성능 평가)

  • Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Prototype double-scattering Compton camera, which consists of three gamma-ray detectors, that is, two double-sided silicon strip detectors (DSSDs) as scatterer detectors and a NaI(Tl) scintillation detector as an absorber detector, could provide high imaging resolution with a compact system. In the present study, the energy resolution and the timing resolution of component detectors were measured, and the parameters affecting the energy resolution of the DSSD were examined in terms of equivalent noise charge (ENC). The energy resolutions of the DSSD-1 and DSSD-2 were, in average, $25.2keV{\pm}0.8keV$ FWHM and $31.8keV{\pm}4.6keV$ FWHM at the 59.5 keV peak of $^{241}Am$, respectively. The timing resolutions of the DSSD and NaI(Tl) scintillation detector were 57.25 ns FWHM and 7.98 ns FWHM, respectively. In addition, the Compton image was obtained for a point-like $^{137}Cs$ gamma source with double-scattering Compton camera. From the present experiment, the imaging resolution of 8.4 mm FWHM (angular resolution of $8.1^{\circ}$ FWHM), and the imaging sensitivity of $1.5{\times}10^{-7}$ (intrinsic efficiency of $1.9{\times}10^{-6}$) were obtained.

Experimental Studies of the Pericardial Substitutes in Rabbits (가토에서 심낭대치물에 관한 실험적 연구)

  • Baeck, Seung-Hwan;Yang, Suk-Rhin;Kim, Sun-Han;Nam, Choong-Hee;Lee, Khil-Rho
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.724-730
    • /
    • 1989
  • The development of severe pericardial adhesion after cardiovascular surgical procedures often increases the risk of injuring the heart, great vessels, or extracardiac grafts during resternotomy. Several pericardial substitutes have been tested in an attempt to facilitate reoperation with inconclusive results. This study was designed to evaluate the applicability of two different materials as pericardial substitutes to minimize the pericardial adhesion and epicardial reaction. A procedure for induction of pericardial adhesion was carried out in 30 rabbits. Rabbits were divided into three groups of ten rabbits each: Group 1[control, simple pericardial closure]: Group 2[bovine pericardium as pericardial substitute]: Group 3[e-polytetrafluoroethylene surgical membrane, e-PTFE as a pericardial substitute]. Bovine pericardium or e-PTFE surgical membrane was interposed between the sternum and the heart. Rabbits were sacrificed at 4 weeks after operation. The development of adhesions and epicardial reactions were graded as: none [I]; minimal[II]; moderate[Ill]; and severe[1V]. Histologic studies of the substitute, the pericardium, and the epicardium were performed. The results were as follows; l. In group 1[control group], the degree of pericardial adhesions were grade I in none, grade II in 1, grade III in 3, and grade 1V in 6 animals. Epicardial reactions were grade I in none, grade II in 3, grade K in 4, grade 1V in 3 animals respectively. 2. In group 2[bovine pericardium], the degree of pericardial adhesions were grade I in 1, grade II in 5, grade III in 3, and grade 1V in 1 animal. Epicardial reactions were grade I in 1, grade II in 2, grade III in 4, and grade 1V in 3 animals respectively. 3. In group 3[e-PTFE], the degree of pericardial adhesions were grade I in 7 animals, grade II in 2, grade III in 1, and grade g in none. Epicardial reactions were grade I in 4, grade II in 3, grade III in 2, and grade IV in 1 animal respectively. Pericardial adhesions more than grade II were 90.9% in group 1, 40 % in group 2, and 10% in group 3. Pericardial adhesions were significantly reduced in group 3 compared to group 1 or 2. Epicardial reactions more than grade II were 70 % in group 1, 70 % in group 2 and 30 % in group 3. We concluded that this 0.1mm thick polytetrafluoroethylene surgical membrane is a suitable pericardial substitute to minimize the development of pericardial adhesion or epicardial reaction following cardiovascular surgery.

  • PDF

An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test (재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가)

  • Kwon, Il-Hyun;Na, Sung-Hun;Song, Gee-Wook;Yu, Hyo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

The Present Situation and Problems of In Vitro Fertilization in Swine (돼지 체외수정의 현황과 문제점)

  • 류일선
    • Journal of Embryo Transfer
    • /
    • v.7 no.1
    • /
    • pp.41-47
    • /
    • 1992
  • 1. In vitro system, LR and FSR accelerated and facilitated meiotic progression, and LH selectively improved cytoplasmic maturation which is required to promote the formation of a male pronucleus. 2. Caffeine (2mM) in the fetilization medium was required not only for inducing zona penetrating ability of boar also for developing to the male pronucleus of the penetrat- ing spermatozoa in vitro. 3. The germinal vesicle (GV)stage was observed for the first 17.6 hr;germinal vesicle break-down (GVBD)stage between 17.6~26.4 hr ;metaphase I (M-I)from 26.4 - 30. 9hr;anaphase I(A-I)ranged from 30. 9~33.4hr;telophase I(T-I) at 33.4~34.4hr; and metaphase II(M-II) at 34.4-48hr. 4. The addition of 10%(v /v) pig follicular fluid (pFF) to maturation media significantly increased the rate of nuclear maturation of pig oocytes (p<0.01), whereas the rate of nuclear maturation of pig oocytes among three different media did not differ. 5. The presence of a primary culture of POEC promotes in vitro development of early cleavage stage pig embryos.

  • PDF

The Development of Iodine-123 with MC-50 Cyclotron (MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구)

  • Suh, Yong-Sup;Yang, Seung-Tae;Chun, Kown-Soo;Lee, Jong-Doo;Han, Hyon-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

Design and Implementation of Sensor-based Secondary Vehicle Accident Prevention System (센서 기반의 차량 2차사고 방지 시스템 설계 및 구현)

  • Lim, Kyung-Gyun;Kim, Gea-Hee;Jeong, Seon-Mi;Mun, Hyung-Jin;Kim, Chang-Geun
    • Journal of Digital Convergence
    • /
    • v.15 no.12
    • /
    • pp.313-321
    • /
    • 2017
  • Traffic accidents in the country have steadily increased. Although IOT technologies have been applied so as to prevent the primary accident, practical solutions to prevent the secondary accident have not been suggested. A general guideline is simply recommended. In this paper, utilizing existing communication technology, we implement a proposed model and its simulation to prevent the secondary accident. When it is possible for a driver to secure visibility, the secondary accident can be prevented; In areas like tunnel, mountain terrain, and curve road with heavy traffic, where the driver has difficulty in securing the visibility, the secondary accident rates after the primary accident have been increasing. Therefore, we implement an accident prevention system that determines the primary accident utilizing sensor technology and prevents the secondary accident communicating through V2V or V2I. After the simulation, we found that the proposed model and the existing model made no difference with regard to the secondary accident rates when the visibility of the driver is secured; With the application of the proposed model, however, the accident rates decreased for 3-7 percent even though the visibility and communication were not secured.

A Study on the Dielectric Phenomenon of PBDG (PBDG의 유전현상에 관한 연구)

  • Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.362-365
    • /
    • 2002
  • This paper, experiment manufactures device of Metal/Poly-${\gamma}$ Benzyl $_D$-GlutamateOrganic Films/Metal structure using PBDG and I-V properties and C-F properties. The I-V characteristic is measured that approve voltage from 0 to +2[V] of device and the distance between electrode is larger, could know that small current flow and thin film could know that had insulation property. C-F characteristic has each other affinity between the polarization amount and frequency. Permittivity of MIM device could know by dipole that is voluntary polarization of LB film that polarization is happened. The capacitor properties of a thin film is better as the distance between electrodes is smaller.

  • PDF

Pharmacokinetic Study of Epigallocatechin Gallate in Rats (녹차의 주성분인 에피갈로카테킨 갈레이트의 흰쥐에서의 약물속도론적 연구)

  • Kim, Dong-Chool;Lim, Jae-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.3
    • /
    • pp.179-184
    • /
    • 1999
  • Phannacokinetics of epigallocatechin gallate(EGCG) was studied following i.v. bolus and oral administration in rats. The values of systemic clearance(CL) were $67.9{\pm}5.2$ and $26.5{\pm}1.4\;ml/min/kg$ following i.v. bolus administration of 1 mg and 5 mg EGCG, respectively. The values of volume of distribution at steady state (Vss) were $380{\pm}56$ and $835{\pm}84\;ml/kg$ after i.v. bolus administration of 1 mg and 5 mg EGCG, respectively. The decrease in the value of CL and the increase in the value of $V_{ss}$ as a function of EGCG dose (1 mg to 5 mg) suggest saturable mechanism(s) responsible for the distribution and elimination of EGCG. The fraction absorbed of EGCG after oral and intraduodenal administration of GTC were 13% and 22% of the dose, respectively. This result suggests a considerable degradation or elimination of EGCG in the gastrointestinal absorption after oral administration in rats.

  • PDF