• Title/Summary/Keyword: $UPLC^{TM}$

Search Result 2, Processing Time 0.014 seconds

Simultaneous Determination of 8 Preservatives (6 Parabens, 2-Phenoxyethanol, and Chlorphenesin) in Cosmetics by $UPLC^{TM}$ ($UPLC^{TM}$를 이용한 화장품 중 보존제 8종(파라벤 6종, 페녹시에탄올, 클로페네신)의 동시분석)

  • Park, Jeong-Eun;Lee, So-Mi;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.4
    • /
    • pp.263-267
    • /
    • 2007
  • Parabens are used in nearly all types of cosmetics and toiletries because they are formulated well and have broad spectrum of activity, interness, low costs and excellent chemical stability in relation to pH. 2-phenoxyethanol and chlorphenesin are common preservatives which are usually used in combination with parabens in cosmetics. Toxicity of parabens is generally low but application of parabens to damaged or broken skin has resulted in sensitization. Moreover, the possibility of their estrogenic potential, anesthetic effects and reproductive toxicity has been reported. Consequently there are some regulations in use of parabens. And the maximum permitted concentrations of chlorphenesin and 2-phenoxyethanol in cosmetic products are authorized by the same reasons. So it is important to control and estimate the amount of parabens in products. In this article, we proposed a valid method for the simultaneous determination of 8 preservatives including parabens in a short time using ultra performance liquid $chromatography^{TM}\;(UPLC^{TM})$. Separation of eight components was achieved in less than 10 min and resolutions were reasonable (USP resolution ${\geqq}\;2$). And limit of detection and quantification were evaluated. The method was suitably validated for specificity, linearity, precision (repeatability, intermediate precision) and accuracy for assay (recovery) based on International conference on harmonisation (ICH) guideline. The method was applicable to analysis of preservatives in cosmetic products.

Determination of Free Amino Acids in Isatidis Radix By HILIC-UPLC-MS/MS

  • Pan, Yilin;Li, Jin;Li, Xiang;Chen, Jianwei;Bai, Ganggang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.197-203
    • /
    • 2014
  • A rapid, accurate and precise method for the determination of 22 amino acids in Isatidis Radix by Hydrophilic Interaction Ultra-High-Performance Liquid Chromatography Coupled with Triple-Quadrupole Mass Spectrometry (HILIC-UPLC-MS/MS) was established. Chromatographic separation was carried out on a Acquity UPLC BEH Amide column ($2.1mm{\times}100mm$, $1.7{\mu}m$) with gradient elution of acetonitrile (containing 0.05% formic acid and 2 mM ammonium formate) and water (containing 0.15% formic acid and 10 mM ammonium formate) at a flow rate of 0.4 mL/min; Waters Xevo$^{TM}$ TQ worked in multiple reaction monitoring mode. All components were separated in 17 min. All calibration curves were linear ($R^2$ > 0.991) over the tested ranges. The limits of detection (LOD) and limits of quantitation (LOQ) for these compounds were 0.21-79.55 and 0.72-294.23 ng/mL, respectively. The average recoveries were in the range of 93.75-104.16% with RSD value less than 6.56%. Therefore, this method could be an alternative assay for the determination of 22 amino acids in Isatidis Radix due to its rapidness, sensitivity, less sample and solvent consumption.