• 제목/요약/키워드: $TiOF_2$

검색결과 10,567건 처리시간 0.042초

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2002년도 제3회 최신 분말제품 응용기술 Workshop
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

A Report of Chigger Mites on the Striped Field Mouse, Apodemus agrarius, in Southwest China

  • Chen, Yan-Ling;Guo, Xian-Guo;Ren, Tian-Guang;Zhang, Lei;Fan, Rong;Zhao, Cheng-Fu;Zhang, Zhi-Wei;Mao, Ke-Yu;Huang, Xiao-Bin;Qian, Ti-Jun
    • Parasites, Hosts and Diseases
    • /
    • 제59권6호
    • /
    • pp.625-634
    • /
    • 2021
  • Based on the field investigations in 91 investigation sites (counties) in southwest China between 2001 and 2019, the present paper reported the chigger mites on A. agrarius mice in southwest China for the first time by using a series of statistical methods. From 715 striped field mice captured in 28 of 91 investigated sites, only 255 chiggers were collected, and they were identified as 14 species, 6 genera in 3 subfamilies under 2 families. Of 715 A. agrarius mice, only 24 of them were infested with chigger mites with low overall prevalence (PM=3.4%), overall mean abundance (MA=0.36 mites/host) and overall mean intensity (MI=10.63 mites/host). The species diversity and infestation of chiggers on A. agrarius were much lower than those previously reported on some other rodents in southwest China. On a certain species of rodent, A. agrarius mouse in southwest China seems to have a very low susceptibility to chigger infestations than in other geographical regions. Of 14 chigger species, there were 3 dominant species, Leptotrombidium sialkotense, L. rupestre and Schoengastiella novoconfuciana, which were of aggregated distribution among different individuals of A. agrarius hosts. L. sialkotense, one of 6 main vectors of scrub typhus in China, was the first dominant on A. agrarius. The species similarity of chigger mites on male and female hosts was low with CSS=0.25, and this reflects the sex-bias of different genders of A. agrarius mice in harboring different chigger species.

임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구 (An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level)

  • 신동환;조규성;박광호;문익상
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

4종 우슬(牛膝)의 외내부형태 연구 (A study on external and internal morphology in 4 kinds of Uie-Suel Radix)

  • 강대훈;김정희;나승영;주영승;김종문
    • 대한본초학회지
    • /
    • 제22권1호
    • /
    • pp.71-79
    • /
    • 2007
  • Objectives : This study was designed to establish a characteristic discrimination of internal and external morphological standard of original plants and herbal states in Polygoni Multiflori and Cynanchi Wilfordii Radix. Methods : In this studies, the external-internal morphological standards were determined by using stereoscope and butanol series. Results: 1. The external characteristics of original plants: Polygonum Multiflorum has alternate leaves, and its flower with white color blooms at the shoot apex or leaf axil. In the other hand, Cynanchum wilfordii has opposite leaves, and its flower with yellowish green color blooms at the leaf axil. 2. The physical characteristics of herbal slates: Polygoni Multiflori Radix is red-brown in outer surface pink-brown in section. In the other hand, Cynanchi Wilfordii Radix is earthly-brown in outer surface greyish white in section. 3. The physical characteristics according to the place of production: Demonstrable difference according to the place of production is not seen. Polygoni Multiflori Radix is brown or dark brown in outer surface, soft $Yellow{\sim}dark$ brown in section. In the other hand, Cynanchi Wilfordii Radix is white in outer surface, $white{\sim}weak$ red in section, and has power type. 4. The internal characteristics: Polygonum multiflorum has hetero-vascular bundle and lignification of cork layer is progressive. In the other hand, Cynanchum wilfordii has not hetero-vascular bundle, and lignification of cork layer is weak. Conclusion: In the future, many fundamental study such as how to discriminate between Polygoni Multiflori Radix and Cynanchi Wilfordii Radix in origin and efficacy will be necessary. Also the standard of discrimination must be specific and distinct in that several kinds of fo-ti has been traded. It is considered the results of this study will be furnish κ I the basis Lo succeeding studies and it is needed to extensive comparative study for the same genus-degree of relatedness.

  • PDF

Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가 (Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images)

  • 곽철은;정준기;이명철
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI 심근 SPECT에서 심근조직에 비하여 간섭취가 상대적으로 높고 이들이 서로 가까이에 위치해 있는 경우 단축단면상의 하위부 또는 하위중격부에서 발생하는 인위적 관류결손의 정도와 여과기의 차단주파수의 관계를 분석하였다. 이러한 영향은 단축단면상 뿐만 아니라 심근 극성지도에서도 관찰되는데, 심근단층상에서 계수분포가 균일하지 못하고 간과 같이 특정부위에 방사능의 집적도가 높은 경우 단층상 재구성시 차단 파수의 적절한 설정에 따라 이 효과를 줄일 수 있는 방법을 제안하였다. 본 연구에서 분석에 사용된 여과기는 저역통과여과기로 이를 사용하는 경우에는 차단주파수를 0.4Nyquist 이상으로 하면 인위적 관류결손의 정도를 충분히 줄일 수 있었다. 그러나 높은 차단주파수에서는 심근영상의 균일도가 떨어지고 배후방사능 및 기타 잡음요인이 효과적으로 제거되지 않기 때문에 적절한 차단주파수의 설정이 중요하며, 본 연구에 사용된 영상에서 여과방법에 따른 원주프로필의 변화가 미세하여 후처리방법을 사용하여 분석하였다. 또한 역투사방법이 비선형적이므로 특정 영상보다는 다양한 간-심근 방사능비에 따른 영상을 분석하여 비선형성을 배제한 연구가 향후 진행되어야 한다.

  • PDF

몬테카를로 시뮬레이션을 통한 중하전입자의 콘크리트 방사화 비교평가 (Comparative Evaluation of Radioactive Isotope in Concrete by Heavy Ion Particle using Monte Carlo Simulation)

  • 배상일;조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.359-365
    • /
    • 2021
  • A heavy particle accelerator is a device that accelerates particles using high energy and is used in various fields such as medical and industrial fields as well as research. However, secondary neutrons and particle fragments are generated by the high-energy particle beam, and among them, the neutrons do not have an electric charge and directly interact with the nucleus to cause radiation of the material. Quantitative evaluation of the radioactive material produced in this way is necessary, but there are many difficulties in actual measurement during or after operation. Therefore, this study compared and evaluated the generated radioactive material in the concrete shield for protons and carbon ions of specific energy by using the simulation code FLUKA. For the evaluation of each energy of proton beam and carbon ion, the reliability of the source term was secured within 2% of the relative error with the data of the NASA Space Radiation Laboratory(NSRL), which is an internationally standardized data. In the evaluation, carbon ions exhibited higher neutron flux than protons. Afterwards, in the evaluation of radioactive materials under actual operating conditions for disposal, a large amount of short-lived beta-decay nuclides occurred immediately after the operation was terminated, and in the case of protons with a high beam speed, more radioactive products were generated than carbon ions. At this time, radionuclides of 44Sc, 3H and 22Na were observed at a high rate. In addition, as the cooling time elapsed, the ratio of long-lived nuclides increased. For nonparticulate radionuclides, 3H, 22Na, and for particulate radionuclides, 44Ti, 55Fe, 60Co, 152Eu, and 154Eu nuclides showed a high ratio. In this study, it is judged that it is possible to use the particle accelerator as basic data for facility maintenance, repair and dismantling through the prediction of radioactive materials in concrete according to the cooling time after operation and termination of operation.

Investigation of dust particle removal efficiency of self-priming venturi scrubber using computational fluid dynamics

  • Ahmed, Sarim;Mohsin, Hassan;Qureshi, Kamran;Shah, Ajmal;Siddique, Waseem;Waheed, Khalid;Irfan, Naseem;Ahmad, Masroor;Farooq, Amjad
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.665-672
    • /
    • 2018
  • A venturi scrubber is an important element of Filtered Containment Venting System (FCVS) for the removal of aerosols in contaminated air. The present work involves computational fluid dynamics (CFD) study of dust particle removal efficiency of a venturi scrubber operating in self-priming mode using ANSYS CFX. Titanium oxide ($TiO_2$) particles having sizes of 1 micron have been taken as dust particles. CFD methodology to simulate the venturi scrubber has been first developed. The cascade atomization and breakup (CAB) model has been used to predict deformation of water droplets, whereas the Eulerian-Lagrangian approach has been used to handle multiphase flow involving air, dust, and water. The developed methodology has been applied to simulate venturi scrubber geometry taken from the literature. Dust particle removal efficiency has been calculated for forced feed operation of venturi scrubber and found to be in good agreement with the results available in the literature. In the second part, venturi scrubber along with a tank has been modeled in CFX, and transient simulations have been performed to study self-priming phenomenon. Self-priming has been observed by plotting the velocity vector fields of water. Suction of water in the venturi scrubber occurred due to the difference between static pressure in the venturi scrubber and the hydrostatic pressure of water inside the tank. Dust particle removal efficiency has been calculated for inlet air velocities of 1 m/s and 3 m/s. It has been observed that removal efficiency is higher in case of higher inlet air velocity.

A STUDY ON THE RESPONSES OF OSTEOBLASTS TO VARIOUS SURFACE-TREATED TITANIUM

  • Lee Joung-Min;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.307-326
    • /
    • 2004
  • Statement of problem. The long-term success of implants is the development of a stable direct connection between bone and implant surface, which must be structural and functional. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. Among them, altering the surface properties can modify cellular responses such as cell adhesion, cell motility and bone deposition. Purpose. This study was to evaluate the cellular behaviors on the surface-modified titanium by morphological observation, cellular proliferation and differentiation. Material and methods. Specimens were divided into five groups, depending on their surface treatment: electropolishing(EP) anoclizing(AN), machining(MA), blasting with hydroxyapatite particle(RBM) and electrical discharge machining(EDM). Physicochemical properties and microstructures of the specimens were examined and the responses of osteoblast-like cells were investigated. The microtopography of specimens was observed by scanning electron microscopy(SEM). Surface roughness was measured by a three-dimensional roughness measuring system. The microstructure was analyzed by X-ray diffractometer(XRD) and scanning auger electron microscopy(AES). To evaluate cellular responses to modified titanium surfaces, osteoblasts isolated from neonatal rat were cultured. The cellular morphology and total protein amounts of osteoblast-like cell were taken as the marker for cellular proliferation, while the expression of alkaline phosphatase was used as the early differentiation marker for osteoblast. In addition, the type I collagen production was determined to be a reliable indicator of bone matrix synthesis. Results. 1. Each prepared specimen showed specific microtopography at SEM examination. The RBM group had a rough and irregular pattern with reticulated appearance. The EDM-treated surface had evident cracks and was heterogeneous consisting of broad sheet or plate with smooth edges and clusters of small grains, deep pores or craters. 2. Surface roughness values were, from the lowest to the highest, electropolished group, anodized group, machined group, RBM group and EDM group. 3. All groups showed amorphous structures. Especially anodized group was found to have increased surface oxide thickness and EDM group had titaniumcarbide(TiC) structure. 4. Cells on electropolished, anodized and machined surfaces developed flattened cell shape and cells on RBM appeared spherical and EDM showed both. After 14 days, the cells cultured from all groups were formed to be confluent and exhibited multilayer proliferation, often overlapped or stratified. 5. Total protein amounts were formed to be quite similar among all the group at 48 hours. At 14 days, the electropolished group and the anodized group induced more total protein amount than the RBM group(P<.05). 6. There was no significant difference among five groups for alkaline phosphatase(ALP) activity at 48 hours. The AN group showed significantly higher ALP activity than any other groups at 14 days(P<.05). 7. All the groups showed similar collagen synthesis except the EDM group. The amount of collagen on the electropolished and anodized surfaces were higher than that on the EDM surface(P<.05).

물리치료사의 요통 유병률과 관련요인 (Prevalence Rate of Low_Back Pain and Its Related Factors in Physical Therapists)

  • 정수연;신형수;박재용
    • The Journal of Korean Physical Therapy
    • /
    • 제17권2호
    • /
    • pp.22-37
    • /
    • 2005
  • This study was performed to investigate LBP(low-back pain) prevalence rate and its related factors inphysical therapists. A self-administered questionnaire survey was conducted to 522 physical therapists in Daegu and Gyeongsangbuk. The LBP prevalence rate for recent 6 months was $61.7\%$. According to age, the prevalence rate was highest in the group aged 24 or less for both male and female physical therapistis. For male physical therapists , it was higher in smokers and drivers, but for female ones, it was not in a significant relationship with smoking and driving. According to work experience, the prevalence rates of those who had been working for less than one year were the highest, and those who had been working at hospitals and clinics were $69.1\%$, significantly high. According to therapy techinque, the prevalence rate related ti PNF was $71.6\%$, the highest and to occupational therapy was $34.3\%$, the lowest. According to working environment for six months, in both male and female physical therapists. LBP prevalence rate was in a statistically significant relationship with work hours during the day, night and weekend duties, repetitive works, motions that bend or twist the waist, the number of patients per day, the number of time to help patients per day, the number of time to carry medical equipment per day and the length of time to work standing. The rate was also higher when physical therapists fekt nire stress from their work. According to the result of multiple logistic regression analysis, male was in a significant relationship with work experience and motions that bend or twist the waist and female was in a significant relationship with work hours during the night and weekend duties, the number of time to help patients per day, motions that bena or twist the waist, actions taken to protect the waist. As for the developmental pattem of LBP in the group of physical therapists with LBP for six moths, $15.7\%$ of them had LBP for first time, $42.3\%$ had recurred LBP, and $42.0\%$ had chronic LBP. As for the causes of LBP, $51.7\%$ said that it was because they worked in the same posture for a long time, and as for how to treat LBP, 48.8% said that they treated themselvs or got help from their co-wokers. The results presented above suggest that physical therapists are exposed to high risk of LBP caused form occupational activities. Therefire, it is necessary to improve working environment to reduce the occurrence of LBP and to develop education programs for preventing the occurrence and recurrence of LBP.

  • PDF

전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향 (Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect)

  • 심재창;김영준;정현주;김옥수
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.