• 제목/요약/키워드: $Tedlar^{(R)}$bags

검색결과 2건 처리시간 0.014초

Aerosol Losses in a 100L $Tedlar^{(R)}$ Bag

  • Oh, Sewon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E2호
    • /
    • pp.61-68
    • /
    • 2004
  • Aerosol losses in a 100L Tedlar$^{(R)}$ bag were investigated for the aerosols with number median diameter of 0.05 ${\mu}{\textrm}{m}$ and number concentration of 6.4 ${\times}$ 10$^4$ cm$^{-3}$ . Over a 1 hr period, loss of particles in the bag is apparent, and the volume decrease with time is significant. The number concentration, surface area, and volume concentration of the aerosols decreased to 34, 50, and 52% of the initial value in 30 min, respectively. This indicates that deposition to the walls was the main loss process for aerosols in the Tedlar$^{(R)}$ bag. Theoretical calculations showed that coagulations and deposition by diffusion and gravitational sedimentation would not change aerosol characteristics significantly, and the electrical force was the dominant loss process for particles in the Tedlar$^{(R)}$ bag over a 1 hr period.eriod.

선택적다중이온질량분석기를 이용한 대기 중 휘발성유기화합물 실시간 동시분석법 개발 및 적용 (Development of Real-time and Simultaneous Quantification of Volatile Organic Compounds in Ambient with SIFT-MS (Selected Ion Flow Tube-Mass Spectrometry))

  • 손현동;안준건;하성용;김기범;임운혁
    • 한국대기환경학회지
    • /
    • 제34권3호
    • /
    • pp.393-405
    • /
    • 2018
  • Volatile organic compounds (VOCs) are representative air pollutants due to their detrimental effects on human health and their role in formation of secondary organic aerosols. Assessments and monitoring programs of VOCs using periodic grab sampling like Tedlar bags, canisters, and sorbent traps provide limited information, often with delay times of days or weeks. Selected ion flow tube mass spectrometry (SIFT-MS) is an emerging analytical technique for the real-time quantification of VOCs in air. It relies on chemical ionization of the VOCs molecules in air introduced into helium carrier gas using $H_3O^+$, $NO^+$, and $O_2{^+}$ precursor ions. Real-time monitoring method of 60 VOCs in the ambient air was developed using TO-15 standard gas mixture. Calibration curves, method detection limit, and quantitation reproducibility of the target compounds were tested. Dynamic dilution system was used to dilute standard gas from 0.174 ppbv to 100 ppbv, where calibration curves showed good linearity with $r^2$> 0.95 in all target analytes. Limit of detection (LOD) all compounds were sub ppbv, and some halogenated compounds showed pptv levels. Seven consecutive analyses of target compounds showed good repeatability with relative standard deviation of less than 10%. One day monitoring of VOCs in ambient air was conducted in Geoje. Average concentration of target VOCs in Geoje were relatively lower than other regions, among which formaldehyde showed the highest concentration ($15.4{\pm}5.78ppbv$). SIFT-MS provided good temporal resolution data (1 data per 3.2 minute), which can be used for identifying ephemeral short-term event. It is expected that SIFT-MS will be a versatile monitoring platform for VOCs in ambient air.