• 제목/요약/키워드: $T_2star$ relaxation times

검색결과 2건 처리시간 0.015초

3.0T MRI에서 온도변화가 T1 및 T2 이완시간에 미치는 영향 (Effect of Temperature on T1 and T2 Relaxation Time in 3.0T MRI)

  • 김호현;권순용;임우택;강충환;김경수;김순배;백문영
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.63-68
    • /
    • 2013
  • Purpose : The relaxation times of tissue in MRI depend on strength of magnetic field, morphology of nuclear, viscosity, size of molecules and temperature. This study intended to analyze quantitatively that materials' temperatures have effects on T1 and T2 relaxation times without changing of other conditions. Materials and Methods : The equipment was used MAGNETOM SKYRA of 3.0T(SIEMENS, Erlagen, Germany), 32 channel spine coil and Gd-DTPA water concentration phantom. To find out T1 relaxation time, Inversion Recovery Spin Echo sequences were used at 50, 400, 1100, 2500 ms of TI. To find out T2 relaxation time, Multi Echo Spin Echo sequences were used at 30, 60, 90, 120, 150, 180, 210, 240, 270 ms of TE. This experiment was scanned with 5 steps from 25 to $45^{\circ}C$. next, using MRmap(Messroghli, BMC Medical Imaging, 2012) T1 and T2 relaxation times were mapped. on the Piview STAR v5.0(Infinitt, Seoul, Korea) 5 steps were measured as the same ROI, and then mean values were calculated. Correlation between the temperatures and relaxation times were analyzed by SPSS(version 17.0, Chicago, IL, USA). Results : According to increase of temperatures, T1 relaxation times were $214.39{\pm}0.25$, $236.02{\pm}0.87$, $267.47{\pm}0.48$, $299.44{\pm}0.64$, $330.19{\pm}1.72$ ms. T2 relaxation times were $180.17{\pm}0.27$, $197.17{\pm}0.44$, $217.92{\pm}0.39$, $239.89{\pm}0.53$, $257.40{\pm}1.77$ ms. With the correlation analysis, the correlation coefficients of T1 and T2 relaxation times were statistically significant at 0.998 and 0.999 (p< 0.05). Conclusion : T1 and T2 relaxation times are increased as temperature of tissue goes up. In conclusion, we suggest to recognize errors of relaxation time caused local temperature's differences, and consider external factors as well in the quantitative analysis of relaxation time or clinical tests.

  • PDF

3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정 (Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System)

  • 류정규;오장훈;김혁기;이선정;서미리내;장건호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 목적: $T_2{^*}$이완시간은 조직의 고유한 특징을 반영하는 자화율 정보를 내재하고 있다. 본 연구는 3테슬러 자기공명영상 기기에서 유방의 정상 유선조직과 지방조직의 $T_2{^*}$이완시간을 알아보고자 하였다. 대상과 방법: 52명의 여자환자에서 (나이, $49{\pm}12 $세; 범위, 25세~75세) 삼차원 경사에코연쇄를 이용하여 각 일곱 개 에코 자기공명영상들을 얻었다. 에코시간은 3.91 ms단계에서 2.28 ms에서 25.72 ms사이 범위였다. 화적소를 기초로 $T_2{^*}$이완시간과 $R_2{^*}$이완율 지도는 각 개체에서 선형곡선맞춤을 이용하여 계산되었다. $T_2{^*}$값과 $R_2{^*}$값을 얻기 위하여 유방의 정상 유선조직과 지방조직에 삼차원 관심영역을 표시하였다. 모든 개체에서 이러한 변수들의 평균치를 계산하였다. 결과: 유방의 정상 유선조직과 지방조직에 삼차원 관심영역 크기는 각각 $4818{\pm}4679$ 화적소와 $1455{\pm}785$ 화적소 였다. 평균 $T_2{^*}$ 값은 유방의 정상 유선조직과 지방조직에서 각각, $22.40{\pm}5.61ms$$36.36{\pm}8.77ms$였다. 평균 $R_2{^*}$값은 유방의 정상 유선조직과 지방조직에서 각각, $0.0524{\pm}0.0134/ms$$0.0297{\pm}0.0069/ms$ 였다. 결론: 유방의 정상 유선조직과 지방조직에서 $T_2{^*}$값과 $R_2{^*}$값을 측정하였다. 유방의 정상 유선조직의 $T_2{^*}$값은 지방조직의 $T_2{^*}$값보다 짧게 나타났다. $T_2{^*}$이완시간의 측정은 유방암과 정상 유방조직에서의 자화율 효과를 이해하는데 도움을 줄 것이다.