• 제목/요약/키워드: $T_2$ contrast

검색결과 1,030건 처리시간 0.023초

Focal nodular hyperplasia: Tripie-contrast enhanced MR imaging using gadolinium chelates, mangafodipir trisodium, and ferumoxides

  • Kim, Joo-Hee;Kim, Myeong-Jin;Park, Young-Nyun;Kim, Kyung-Sik;Lee, Jong-Tae;Yoon, Hyung-Sik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.140-140
    • /
    • 2001
  • We present two cases of surgically proven focal nodular hyperplasia whou underwent tri contrast-enhance MR imaging using gadolinium chelates, mangafodipir trisodium, and ferumoxides After the unehanced MR images were obtained, dynamic gadolinium-enhanced T1-weighted imagi were performed, then mangafodipir enhanced and ferumoxides-enhanced images were obtained. In one case, the mass was isointense on both T1- and T2-weighted images on the unehanced M images, iso and slightly hyperintense on ferumoxides-enhanced FSE and GRE images, strong hyperintense on the mangafodipir enhanced and gadolinium enhanced arterial phase images. In th other case, the mass was isointense on T2-weighted and hypointense on T1-weighted image isointense on ferumoxides-enhanced images, and hyperintense on mangafodipir enhanced an gadolinium enhanced arterial phase images. Triple contrast enhanced MR images were useful correctly diagnose these two cases preoperatively.

  • PDF

EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정 (Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.27-33
    • /
    • 2000
  • 목적: 전자상자성 공명(Electron Paramagnetic Resonance EPR)을 사용하여, 현재 상용되고 있는 세가지 상자성 자기공명 조영제, Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA의 전자스핀 이완시간 $T_{le}$를 결정하고자 한다. 대상 및 방법: 본 연구에 사용된 상자성 자기공명 조영제는 Gd-DTPA(Magnevist), Gd-DTPA-BMA(OMNISCAN), Gd-DOTA(Dotarem)이다. 이들 자기공명 조영제들은 2:1 부피 비율의 메탄올과 물의 혼합용액에 희석하여 저온의 glassy상태에서 EPR스펙트럼을 얻었으며, 또한 주어진 영 자기장 갈라지기 (zero-field splitting, ZFS)변수를 $3{\times}3$ 텐서량으로 계산하는 컴퓨터 시뮬레이션 프로그램 'GEN'을 사용하여, 이들 조영제들에 대한 각각 다른 ZFS변수를 가지는 시뮬레이션 스펙트럼을 만들었다. 이 결과들과 McLachlan의 평균이완율 이론을 적용하여 전자스핀 이완시간이 결정되었다. 결과: 상자성 자기공명 조영제 Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA의 전자 횡축 스핀이완시간($T_{2e}$)은 각각 0.113ns, 0.147ns, 1.81ns, g-value는 1,9737, 1.9735, 1.9830, 전자스핀 이완시간($T_{le}$)는 18.70ns, 33.40ns, $1.66{\mu}s$로 결정되었다. 결론: 실험 결과로부터 상자성 자기공명 조영제의 ZFS변수가 클수록 짧은 전자스핀 이완시간 $T_{le}$를 가진다는 일반적인 사실을 재 확인할 수 있었다. 본 연구에 사용된 3가지 자기 공명 조영제들 중에는 화학적으로 환상구조 배위자를 갖는 Gd-DOTA가 가장 긴 전자스핀 이완시간 $T_{le}$를 가지는 것으로 나타나서 일반적으로 환상구조 배위자를 갖는 조영제들이 선상구조 배위자를 갖는 조영제에 비해 전자적인 성질은 우수한 것으로 나타났고 결론적으로 상자성 조명제가 물분자의 자기이완시간에 미치는 영향을 평가하고 고효율 상자성 자기 공명 조영제 개발에는 정확한 ZFS변수 결정이 매우 중요하다는 것을 알 수 있었다.

  • PDF

조영증강을 보이는 뇌종양의 평가에 있어 T1강조 FLAIR 영상과 스핀에코 MR 영상의 비교 (T1-weighted FLAIR MR Imaging for the Evaluation of Enhancing Brain Tumors: Comparison with Spin Echo Imaging)

  • 정보슬;최대섭;신화선;최혜영;박미정;전경녀;나재범;정성훈
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.151-156
    • /
    • 2014
  • 목적: T1강조 MR영상은 뇌의 해부학적 구조와 병리학적 이상을 보여 주는 기본적인 영상기법의 하나로, 전통적으로 스핀에코(SE) 기법을 이용하여 획득하고 있다. 최근 FLAIR 기법을 이용하여 T1강조영상을 얻을 수 있게 되었으며, SE보다 높은 대조도의 영상을 제공한다고 알려져 있다. 그러나 조영증강을 보이는 뇌종양의 평가에 있어 T1 FLAIR 영상의 유용성에 대해서는 논란이 있다. 본 연구의 목적은 조영증강을 보이는 두개 내 종양의 평가에 있어 SE T1강조영상과 비교하여 T1 FLAIR영상의 유용성을 평가하고자 하였다. 대상과 방법: 총 52명 환자의 79개 병변을 대상으로 하였다. 각 환자에서 조영증강 후 SE T1강조영상과 T1 FLAIR 영상을 획득하였다. 정량적 분석으로 각각의 영상에서 병변, 뇌회색질(GM), 뇌백질(WM), 뇌척수액(CSF), 배경(background)의 신호강도를 측정하였고, 이를 바탕으로 병변과 WM, 병변과 GM, 병변과 CSF, WM와 GM의 contrast ratio(CR), contrast-to-noise(CNR)를 계산하였다. 정성적 분석으로 두 명의 영상의학과 의사가 각 영상에서 병변의 명확도(lesion conspicuity)를 비교 하였다. 결과: 정량적 분석 결과에서 T1 FLAIR영상의 병변과 GM, 병변과 CSF, WM와 GM의 CR, CNR 모두 SE T1강조영상보다 우월하였으며 이는 통계적으로 유의하였다. 그러나 병변과 WM의 CR, CNR은 비슷하였으며 통계적으로 유의한 차이를 보이지 않았다. 정성적 분석에서 두 영상의학과 의사 모두 병변의 명확도에 있어 T1 FLAIR영상이 SE영상보다 우월하다고 평가하였다. 결론: 조영증강을 보이는 뇌종양의 평가에 있어 T1 FLAIR영상은 SE T1강조영상보다 우수하거나 필적한 결과를 보였다.

Radiomics of Non-Contrast-Enhanced T1 Mapping: Diagnostic and Predictive Performance for Myocardial Injury in Acute ST-Segment-Elevation Myocardial Infarction

  • Quanmei Ma;Yue Ma;Tongtong Yu;Zhaoqing Sun;Yang Hou
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.535-546
    • /
    • 2021
  • Objective: To evaluate the feasibility of texture analysis on non-contrast-enhanced T1 maps of cardiac magnetic resonance (CMR) imaging for the diagnosis of myocardial injury in acute myocardial infarction (MI). Materials and Methods: This study included 68 patients (57 males and 11 females; mean age, 55.7 ± 10.5 years) with acute ST-segment-elevation MI who had undergone 3T CMR after a percutaneous coronary intervention. Forty patients of them also underwent a 6-month follow-up CMR. The CMR protocol included T2-weighted imaging, T1 mapping, rest first-pass perfusion, and late gadolinium enhancement. Radiomics features were extracted from the T1 maps using open-source software. Radiomics signatures were constructed with the selected strongest features to evaluate the myocardial injury severity and predict the recovery of left ventricular (LV) longitudinal systolic myocardial contractility. Results: A total of 1088 segments of the acute CMR images were analyzed; 103 (9.5%) segments showed microvascular obstruction (MVO), and 557 (51.2%) segments showed MI. A total of 640 segments were included in the 6-month follow-up analysis, of which 160 (25.0%) segments showed favorable recovery of LV longitudinal systolic myocardial contractility. Combined radiomics signature and T1 values resulted in a higher diagnostic performance for MVO compared to T1 values alone (area under the curve [AUC] in the training set; 0.88, 0.72, p = 0.031: AUC in the test set; 0.86, 0.71, p = 0.002). Combined radiomics signature and T1 values also provided a higher predictive value for LV longitudinal systolic myocardial contractility recovery compared to T1 values (AUC in the training set; 0.76, 0.55, p < 0.001: AUC in the test set; 0.77, 0.60, p < 0.001). Conclusion: The combination of radiomics of non-contrast-enhanced T1 mapping and T1 values could provide higher diagnostic accuracy for MVO. Radiomics also provides incremental value in the prediction of LV longitudinal systolic myocardial contractility at six months.

Prognostic Value of Dynamic Contrast-Enhanced MRI-Derived Pharmacokinetic Variables in Glioblastoma Patients: Analysis of Contrast-Enhancing Lesions and Non-Enhancing T2 High-Signal Intensity Lesions

  • Yeonah Kang;Eun Kyoung Hong;Jung Hyo Rhim;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sun-Won Park;Seung Hong Choi
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.707-716
    • /
    • 2020
  • Objective: To evaluate pharmacokinetic variables from contrast-enhancing lesions (CELs) and non-enhancing T2 high signal intensity lesions (NE-T2HSILs) on dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging for predicting progression-free survival (PFS) in glioblastoma (GBM) patients. Materials and Methods: Sixty-four GBM patients who had undergone preoperative DCE MR imaging and received standard treatment were retrospectively included. We analyzed the pharmacokinetic variables of the volume transfer constant (Ktrans) and volume fraction of extravascular extracellular space within the CEL and NE-T2HSIL of the entire tumor. Univariate and multivariate Cox regression analyses were performed using preoperative clinical characteristics, pharmacokinetic variables of DCE MR imaging, and postoperative molecular biomarkers to predict PFS. Results: The increased mean Ktrans of the CEL, increased 95th percentile Ktrans of the CELs, and absence of methylated O6-methylguanine-DNA methyltransferase promoter were relevant adverse variables for PFS in the univariate analysis (p = 0.041, p = 0.032, and p = 0.083, respectively). The Kaplan-Meier survival curves demonstrated that PFS was significantly shorter in patients with a mean Ktrans of the CEL > 0.068 and 95th percentile Ktrans of the CEL > 0.223 (log-rank p = 0.038 and p = 0.041, respectively). However, only mean Ktrans of the CEL was significantly associated with PFS (p = 0.024; hazard ratio, 553.08; 95% confidence interval, 2.27-134756.74) in the multivariate Cox proportional hazard analysis. None of the pharmacokinetic variables from NE-T2HSILs were significantly related to PFS. Conclusion: Among the pharmacokinetic variables extracted from CELs and NE-T2HSILs on preoperative DCE MR imaging, the mean Ktrans of CELs exhibits potential as a useful imaging predictor of PFS in GBM patients.

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권1호
    • /
    • pp.57-65
    • /
    • 2001
  • 목적 : 초고속 Echo Planar Imaging (EPI) 의 데이터 측정시간을 반으로 단축시킨 half courier EPI와 임상에서 널리 사용하는 $T_2$ 강조 영상을 결합한 $T_2$-weighted half courier EPI(T2HEPl) 영상기법을 제안하였다. 제안한 방법으로 강한 $T_2$ 대조도를 갖는 $128{\times}128$의 고해상도 EPI 영상을 single scan으로 얻고자 한다. 대상 및 방법 : 초고속 EPI 기법의 데이터 측정시간을 줄이기 위하여 k-space의 절반만을 측정하고, 나머지 절반은 conjugate symmetry 성질을 이용하여 재구성한다. 따라서 64개의 에코로 $128{\times}128$의 고해상도 single shot 영상을 얻을 수 있다. 또한 k-space 데이터의 순서를 시간 축에서 조절하여 강한 $T_2$ 대조도를 갖는 영상을 얻을 수 있다 Eddy current의 영향으로 phase encoding 방향으로 잔류 경사자계가 있을 경우 측정된 데이터들은 k-space에서 이동이 되며 , 이것은 재구성 영상에 심각한 문제점을 초래하게 된다. 본 논문에서는 pre-scan에서 얻은 기준 데이터와 dc에 해당하는 에코간의 상관도를 측정하여 이동을 추정하며, 초기의 phase encoding gradient의 크기를 조정하여 이러한 이동을 제거한다. 결과 : 제안한 $T_2$-weighted half courier EPI 영상기법을 1.0 Tesla 전신 MRI 시스템에 적용하였다. 실험 조건은 single shot으로 TR은 무한대이고, TE는 72ms와 96ms로 설정하였다. 제안한 영상기법을 이용하여 single scan으로 강한 $T_2$ 대조도를 갖는 128x128의 고해상도 EPI 영상을 얻을 수 있었다. 결론 : 제안한 Half Fourier기법을 이용하여 기존의 $64{\times}64$ 영상보다 해상도를 높인 $128{\times}128$ EPI영상을 single scan으로 얻을수 있었으며, 에코의 적절한 배치를 통해 임상에서 널리 사용되는 $T_2$ 대조도를 얻을 수 있었다. 제안한 방법은 특별한 하드웨어의 추가 없이, 펄스 시퀀스와 tuning 및 재구성 알고리즘 등의 소프트웨어적인 방법만으로 구현이 가능하여 많은 임상 응용이 기대된다.

  • PDF

NPP 매질내에서 공간주파수 응답을 이용한 초음파 영상의 깊이 분해능 개선을 위한 복원 방법 (The Reconstructive Method for The Enhancement of Depth Resolution for Acoustic Image using the Spatial Frequency Response in NPPs' Material)

  • Koo, Gil-mo;Kim, Hyun;Park, In-ho
    • 한국멀티미디어학회논문지
    • /
    • 제5권4호
    • /
    • pp.426-433
    • /
    • 2002
  • 본 연구에서는 초음파현미경의 동작주파수 변화에 따라서 획득한 영상의 조합을 통하여 얻어진 영상들에 관하여 연구하였다. 고체내부의 영상을 복원하는 경우, 얻어진 영상들은 표면이 상태가 중첩되어 나타나게 된다. 이 경우 위상체 영상들은 내부 영상의 콘트라스트 개선에 활용되어 질 수 있다. 실험에서는 두가지 종류의 시편이 사용되었다. 첫째는 NPP내부에서 스팀 발생장치의 주 파이프의 매질측면에 1/4T, 1/2T, 3/4T의 홀 결함을 갖는 기준 블록이고 다른 시편은 직경이 1-2mm인 반구형태의 시편이다. 실험결과 기본의 영상처리 방법에 비하여 결함 형태에 대한 콘트라스트가 2배 정도의 향상을 보였다. 실험을 위하여 반사신호의 진폭과 위상을 동시에 획득할 수 있는 쿼드러춰 검출기를 사용한 초음파현미경 시스템을 구성하였다. 앞으로는 진폭과 위상영상의 재구성 방법과 결함영상의 콘트라스트를 개선시키기 위한 방법이 계속 연구되어져야겠다.

  • PDF

Dual Contrast EPI by Use of a Key Hole Technique

  • Jung, Kwan-Jin
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.113-113
    • /
    • 2001
  • Purpose: In the gradient echo EPI the conventional T2*-weighted image is poor in signal as well distorted by the field inhomogeneity. By acquiring a proton density image in addition to th T2*-weighted image at the same scan, the fMRI processing can be improved. Method: The central region of the k space is acquired twice at different time points after th RF pulse while acquiring the other regions onc as described in Fig. 1. In Fig. 1 the segment numbers are chronological. Then, we can get two images of different contrast by interleaving th central region in the k space as done in the dua contrast FSE.

  • PDF

프로젝션 타입 고속 스핀 에코 자기공명 영상에서의 대조도 분석 (Contrast analysis in the Projection-type fast spin echo imaging in MRI)

  • 김치영;김휴정;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3216-3218
    • /
    • 2000
  • Projection-type Fast Spin Echo (PFSE) imaging has robustness against motion artifacts due to patient motion during magnetic resonance imaging data acquisition, or reduce flow artifacts. However, it has difficulty in controlling T2 contrast. In this paper, T2 contrast in the PFSE method is analyzed. The contrasts in FSE and PFSE method are compared by computer simulation and experiments with volunteers.

  • PDF

The assessment of tumoral necrosis in rat tumor model using dynamic T1/T2* gradient dual echo sequence with Gd-DTPA and Gadomer-17 as a MR contrast agent

  • 허용민;김대홍;김은주;송호택;서진석;이상훈
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.93-93
    • /
    • 2003
  • To test the feasibility of rBF and rBVin the assessment of R004 sarcomas of the rat and to compare the results obtained by using Gd-DTPA and Gadomer-17 as a MR contrast agent, on the basis of the histological findings of tumor necrosis.

  • PDF