• Title/Summary/Keyword: $SO_X$

Search Result 3,435, Processing Time 0.036 seconds

The Relationship between Social Relations and Physical Activity in the Young-old and Old-old Elderly (전·후기 노인들의 사회적 관계와 신체활동 실천과의 관련성)

  • So Youn Jeon;Sok Goo Lee
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.2
    • /
    • pp.103-117
    • /
    • 2023
  • Objectives: This study aims to reveal the relationship between social relations and physical activity in the young-old and old-old elderly. Methods: Data from 2020 National survey of Older Koreans were used, and a total of 10,097 subjects over the age of 65 were included in analysis. The dependent variable was physical activity, and the independent variables were social relations barrier and motivational factors. x2-test and binary logistic regression were performed for data analysis. Results: The physical activity rate in the elderly were 40.8% in the young-old and 29.2% in the old-old. The socio-demographic characteristics affecting physical activity were the young-old elderly were sex, residential area, employment status and household income, and the old-old elderly were sex, age, residential area, education level and household income. The social relations barrier factors affecting physical activity were the young-old elderly were number of close friends, family care, exercise information search and video viewing, and the old-old elderly were household type, number of close friends, participation in exercise education, exercise information search and video viewing. The social relations motivational factors affecting physical activity were the young-old elderly were call with children/relative/friend, participation in sports activity, access time from home to parks, and the old-old elderly were call with children/relative/friend, participation in sports activity, satisfaction with green spaces. Conclusions: It was found that social relations barrier and motivational factors of the elderly are important factors to consider when developing physical activity promotion strategy, and there are also difference between the age of the elderly.

Difference of perception of the duties of dental hygienist between dentists and dental hygiene students in an area (일개 지역 치과의사와 치위생학과 학생 간 치과위생사의 업무에 대한 인식의 차이)

  • Hwang, Soo-Jeong;Koong, Hwa-Soo;Lee, Sang-Hoon
    • Journal of Korean Academy of Dental Administration
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Although dental hygienists have performed chair-side assisting and other dental cares as well as preventive dental cares in Korea, medical technician law confines duties of dental hygienists as closed narrative. The aim of this study was to investigate difference in perception of duties of dental hygienists in dental clinic between dentists and dental hygiene students. A total of 245 copies of questionnaires were distributed to dentists and students by post-mail. Only 42 dentists and 30 students in an area replied these questionnaires about the present and future duties of dental hygienists after providing written consent. Both groups agreed that intra and extra oral X-ray taking, education about oral health behavior, instruction after dental treatment, chair-side assisting, consulting for patients, scaling, initial impression taking, management of dental materials and equipment, sterilization of equipment, and receiving dental bills are duties of dental hygienists. However, they had different perceptions about various dental treatments as duties of dental hygienists even if they were under instructions of a dentist, including infiltration anesthesia, filling in cavity, intramuscular injection, FC change, canal irrigation, orthodontic treatment including separating, ligature bracket bonding and removing, setting crown and bridge, making individual, removing implant screw, and so on. These findings demonstrated that there were different perceptions about duties of dental hygienists between dentists and dental hygiene students, especially on dental treatment.

The Study on the Factors of film's Processing Fluency Inducing Film's Preference Fluency (영화의 선호도 유창성에 영향을 미치는 영화의 처리 유창성 요인에 관한 연구)

  • Choi, Nak Hwan;Lim, Ahyoung
    • Asia Marketing Journal
    • /
    • v.13 no.4
    • /
    • pp.29-54
    • /
    • 2012
  • Recently, as film has been admitted as the artistic merit and higher value-added business, the past studies on film have been lively carried on various fields. Especially, the film business is thought to be value-added business and has explored the causes of influencing spectators. However, there are no researches enough to explain what induces the choice and diffusion of the film. The film is not only hedonic products but also typical example of experiential products. So how to process film formation plays important roles in explaining the procedures of forming preference on the film and the movies spread more widely. But the great part of study of films has been concentrated on exploring hedonic factors of influencing spectator's choice. Until now there is not enough study for the relationship between experiential information processing and film preference. To explain film's preference, our study focuses on preference fluency and processing fluency that can provide an insight for our question about the relationship. In this article, to explain the procedures of processing experiential information and forming preference on the film, our study focuses on finding the relationship between film's processing fluency and film's preference fluency and explores the factors that affect film's processing fluency. To achieve the goal of this study, we distinguish factors of film's conceptual fluency from factors of film's perceptual fluency and explore the paths from the factors to film's preference fluency. The factors which have effects on perceptual fluency are hypothesized to be distinction of image expression, distinction of sound expression, correspondence between actors' image and their role. The factors which have effect on conceptual fluency are supposed to be well-organized story, suitability of lines expression. The experiments in which students were sampled at 'C' university were conducted in 2010 (december). Data collection was proceeded through questionnaires. We test the hypothesized model by using structural equation modeling(Amos 17.0). The fit indices for the model are as follows : x2=416.266(df=213, p=0.00), GFI=0.855, AGFI=0.812, RMSEA =0.069, IFI=O.925, CFI=0.920, TLI=0.905. According to the guidelines, there is evidence that our measurement model fits data. The results of empirical study are as follows. The path from film's perceptual fluency to film's preference fluency is supported(estimate: 0.223, C.R: 2.641). The path from film's conceptual fluency to film's preference fluency is supported(estimate: 0.397, C.R: 4.863). The path from distinction of image expression to film's perceptual fluency is not supported(estimate: 0.113, C.R: 1.665). The path from distinction of sound expression to film's perceptual fluency is supported (estimate: 0.190, C.R: 2.042). The path from correspondence between actors' image and their role to film's perceptual fluency is supported(estimate: 0.686, C.R: 5.566). The path from well-organized story to film's conceptual fluency is supported(estimate: 0.396, C.R: 4.023). The path from suitability of lines expression to film's conceptual fluency is supported(estimate: 0.536, C.R: 5.441). Concludingly, our study explored the influencing factors of film's processing fluency inducing film's Preference fluency. First, film's perceptual fluency and film's conceptual fluency have positive effects on film's preference fluency. Second, distinction of image expression is not significant on film's perceptual fluency, but distinction of sound expression and image's correspondence of actors' image and their role have positive effects on film's perceptual fluency. Lastly, well-organized story and suitability of lines expression have positive effects on film's conceptual fluency.

  • PDF

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study (비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구)

  • So Jung Ki;Chul Hwan Park;Kyunghwa Han;Jae Min Shin;Ji Young Kim;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1493-1504
    • /
    • 2021
  • Purpose This study aimed to evaluate the utility of the 16-cm axial volume scan technique for calculating the coronary artery calcium score (CACS) using non-enhanced chest CT. Materials and Methods This study prospectively enrolled 20 participants who underwent both, non-enhanced chest CT (16-cm-coverage axial volume scan technique) and calcium-score CT, with the same parameters, differing only in slice thickness (in non-enhanced chest CT = 0.625, 1.25, 2.5 mm; in calcium score CT = 2.5 mm). The CACS was calculated using the conventional Agatston method. The difference between the CACS obtained from the two CT scans was compared, and the degree of agreement for the clinical significance of the CACS was confirmed through sectional analysis. Each calcified lesion was classified by location and size, and a one-to-one comparison of non-contrast-enhanced chest CT and calcium score CT was performed. Results The correlation coefficients of the CACS obtained from the two CT scans for slice thickness of 2.5, 1.25, and 0.625 mm were 0.9850, 0.9688, and 0.9834, respectively. The mean differences between the CACS were -21.4% at 0.625 mm, -39.4% at 1.25 mm, and -76.2% at 2.5 mm slice thicknesses. Sectional analysis revealed that 16 (80%), 16 (80%), and 13 (65%) patients showed agreement for the degree of coronary artery disease at each slice interval, respectively. Inter-reader agreement was high for each slice interval. The 0.625 mm CT showed the highest sensitivity for detecting calcified lesions. Conclusion The values in the non-contrast-enhanced chest CT, using the 16-cm axial volume scan technique, were similar to those obtained using the CACS in the calcium score CT, at 0.625 mm slice thickness without electrocardiogram gating. This can ultimately help predict cardiovascular risk without additional radiation exposure.

Prevalence of Incidentally Detected Spondylolysis in Children (소아 환자에서 우연히 발견되는 척추분리증의 유병률)

  • Boram Song;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.127-137
    • /
    • 2022
  • Purpose To assess the prevalence of incidentally detected lumbar spondylolysis in children. Materials and Methods We retrospectively reviewed the data of 809 patients under the age of 11 years (mean age, 7.0 ± 2.7 years; boys:girls = 479:330) who underwent abdominal and pelvic CT between March 2014 and December 2018. We recorded the presence, level, and laterality (unilateral or bilateral) of spondylolysis. Patients were divided into two groups based on the presence of spondylolysis: the spondylolysis (SP) and non-SP groups. Results In total, 21 cases of spondylolysis were detected in 20 patients (20/809, 2.5%). The mean age of the SP group was higher than that of the non-SP group (7.8 ± 1.8 vs. 6.9 ± 2.7 years, p > 0.05). The prevalence of spondylolysis in boys was higher than that in girls (15/479 [3.1%] vs. 5/330 [1.5%], p > 0.05). The prevalence of spondylolysis in school-age children (6-10 year olds) was higher than that in preschool-age children (0-5 year olds) (17/538 [3.2%] vs. 3/271 [1.1%], p > 0.05). L5 was the most common level of spondylolysis (76.2%); one 8-year-old boy had two-level spondylolysis. One case of isthmic spondylolisthesis was detected in a 10-year-old boy (1/809, 0.1%). There were 11 unilateral spondylolysis cases (11/21, 52.4%). Conclusion In our study, the prevalence of spondylolysis in children under the age of 11 was 2.5%. The prevalence was higher in boys than in girls and in school-age than in preschool-age children, despite the lack of any statistically significant differences.

The study on the cleft lip and/or palate patients who visited Dept. of Orthodontics, Seoul National University Dental Hospital during last 11 years (1988.3-1999.2) (최근 11년간 서울대학교병원 교정과에 내원한 순구개열 환자의 내원 현황에 관한 연구(1988.3 - 1999.2))

  • Yang, Won-Sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.467-481
    • /
    • 1999
  • Cleft lip and/or palate is one of the most common congenital craniofacial anomalies. According to previous epidemiologic studies, incidence of cleft lip and/or palate has been increasing nowadays. However, there is no report about epidemiologic study of cleft lip and/or palate patients who visited dept. of orthodontics in Korea. So the purpose of this study was to provide the epidemiological characteristics and important basic clinical data for the diagnosis and the treatment of the cleft lip and/or palate patients. With the orthodontic and cleft charts, diagnostic models and X-ray films from 250 patients with cleft lip and/or palate who visited Dept. of Orthodontics, Seoul National University Dental Hospital during the last 11 years, the authors investigated patient's visiting yew, types of cleft, patient's gender, and Angle's classification of malocclusion, and surgery timing. The results were as follows ; 1. The number of cleft patients who visited Dept. of Orthodontics, SNUDH increased during 1988-1990 and then it declined until 1992. From 1993 to 1996, it showed a stationary trend. After 1997 it showed an overwhelmingly increasing trend. 2. In the cleft type, the ratio of cleft lip cleft lip and alveolus cleft palate : cleft lip and palate was 7.6:19.2:9.6:63.6. In cleft position, unilateral clefts were more than bilateral ones (cleft lip 79:21, cleft lip and alveolus 77:23, cleft lip and palate 75.5:24.5). In cleft side, left clefts were mote than right clefts (cleft lip 53.3:46.7 cleft lip and alveolus 59.5:40.5, cleft lip and palate 59.2:40.8). 3. In gender ratio, males were more than females in cleft lip (57.9:42.1), cleft lip and alveolus (68.8:31.2) and cleft lip and palate (76.1:23.9). But in cleft Palate females were more than males as 41.7: 58.3. 4. In the age groups, 7-12 year group was the most abundant as $52\%$, and then 0-6 year group ($20.4\%$), 13-18 year group ($17.2\%$), more than 18 yew group ($10.4\%$) were followed as descending order. 5. Most of the cleft lip repair surgeries were operated in 0-3 month ($60.3\%$) and 4-6 month ($17.9\%$). 6. The cleft palate repair surgeries were done in 1-2 year ($31.7\%$), 0-1 year ($25.6\%$), 2-3 year ($12.1\%$), more than 5 year ($11.6\%$) as descending order. 7. The lip scar revision surgeries were done before admission at elementary school in $60\%$. (4-6 you ($27.5\%$), 6-8 year ($19.6\%$), more than 10 year ($19.6\%$), 2-4 year ($13.7\%$) as descending order) 8. The rhinoplasties were done before admission at elementary school in $51.7\%$. (0-2 year ($7.1\%$), 2-4 year ($14.3\%$), 4-6 year ($21.4\%$), 6-8 year ($14.3\%$)). 9. The pharyngeal flap were done at 6 Y (72.5 months) after birth on average and there was even distribution of surgery timing. 10. In relationship between Angle's classification of malocclusion and cleft types, Class I was most abundant and Class III, Class II were followed as descending order in cleft lip group. But Class III was most abundant and Class I, Class II were followed as descending order in cleft lip and alveolus group, cleft palate group, and cleft lip and Palate group. The percentage of frequency in Class III malocclusion was overwhelmingly higher in cleft lip and palate group than any other groups. 11. Because the frequency of class III malocclusion was most prevalent in all age groups, anterior crossbite was the most common chief complaint of cleft patients.

  • PDF

Perceptional Change of a New Product, DMB Phone

  • Kim, Ju-Young;Ko, Deok-Im
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.3
    • /
    • pp.59-88
    • /
    • 2008
  • Digital Convergence means integration between industry, technology, and contents, and in marketing, it usually comes with creation of new types of product and service under the base of digital technology as digitalization progress in electro-communication industries including telecommunication, home appliance, and computer industries. One can see digital convergence not only in instruments such as PC, AV appliances, cellular phone, but also in contents, network, service that are required in production, modification, distribution, re-production of information. Convergence in contents started around 1990. Convergence in network and service begins as broadcasting and telecommunication integrates and DMB(digital multimedia broadcasting), born in May, 2005 is the symbolic icon in this trend. There are some positive and negative expectations about DMB. The reason why two opposite expectations exist is that DMB does not come out from customer's need but from technology development. Therefore, customers might have hard time to interpret the real meaning of DMB. Time is quite critical to a high tech product, like DMB because another product with same function from different technology can replace the existing product within short period of time. If DMB does not positioning well to customer's mind quickly, another products like Wibro, IPTV, or HSPDA could replace it before it even spreads out. Therefore, positioning strategy is critical for success of DMB product. To make correct positioning strategy, one needs to understand how consumer interprets DMB and how consumer's interpretation can be changed via communication strategy. In this study, we try to investigate how consumer perceives a new product, like DMB and how AD strategy change consumer's perception. More specifically, the paper segment consumers into sub-groups based on their DMB perceptions and compare their characteristics in order to understand how they perceive DMB. And, expose them different printed ADs that have messages guiding consumer think DMB in specific ways, either cellular phone or personal TV. Research Question 1: Segment consumers according to perceptions about DMB and compare characteristics of segmentations. Research Question 2: Compare perceptions about DMB after AD that induces categorization of DMB in direction for each segment. If one understand and predict a direction in which consumer perceive a new product, firm can select target customers easily. We segment consumers according to their perception and analyze characteristics in order to find some variables that can influence perceptions, like prior experience, usage, or habit. And then, marketing people can use this variables to identify target customers and predict their perceptions. If one knows how customer's perception is changed via AD message, communication strategy could be constructed properly. Specially, information from segmented customers helps to develop efficient AD strategy for segment who has prior perception. Research framework consists of two measurements and one treatment, O1 X O2. First observation is for collecting information about consumer's perception and their characteristics. Based on first observation, the paper segment consumers into two groups, one group perceives DMB similar to Cellular phone and the other group perceives DMB similar to TV. And compare characteristics of two segments in order to find reason why they perceive DMB differently. Next, we expose two kinds of AD to subjects. One AD describes DMB as Cellular phone and the other Ad describes DMB as personal TV. When two ADs are exposed to subjects, consumers don't know their prior perception of DMB, in other words, which subject belongs 'similar-to-Cellular phone' segment or 'similar-to-TV' segment? However, we analyze the AD's effect differently for each segment. In research design, final observation is for investigating AD effect. Perception before AD is compared with perception after AD. Comparisons are made for each segment and for each AD. For the segment who perceives DMB similar to TV, AD that describes DMB as cellular phone could change the prior perception. And AD that describes DMB as personal TV, could enforce the prior perception. For data collection, subjects are selected from undergraduate students because they have basic knowledge about most digital equipments and have open attitude about a new product and media. Total number of subjects is 240. In order to measure perception about DMB, we use indirect measurement, comparison with other similar digital products. To select similar digital products, we pre-survey students and then finally select PDA, Car-TV, Cellular Phone, MP3 player, TV, and PSP. Quasi experiment is done at several classes under instructor's allowance. After brief introduction, prior knowledge, awareness, and usage about DMB as well as other digital instruments is asked and their similarities and perceived characteristics are measured. And then, two kinds of manipulated color-printed AD are distributed and similarities and perceived characteristics for DMB are re-measured. Finally purchase intension, AD attitude, manipulation check, and demographic variables are asked. Subjects are given small gift for participation. Stimuli are color-printed advertising. Their actual size is A4 and made after several pre-test from AD professionals and students. As results, consumers are segmented into two subgroups based on their perceptions of DMB. Similarity measure between DMB and cellular phone and similarity measure between DMB and TV are used to classify consumers. If subject whose first measure is less than the second measure, she is classified into segment A and segment A is characterized as they perceive DMB like TV. Otherwise, they are classified as segment B, who perceives DMB like cellular phone. Discriminant analysis on these groups with their characteristics of usage and attitude shows that Segment A knows much about DMB and uses a lot of digital instrument. Segment B, who thinks DMB as cellular phone doesn't know well about DMB and not familiar with other digital instruments. So, consumers with higher knowledge perceive DMB similar to TV because launching DMB advertising lead consumer think DMB as TV. Consumers with less interest on digital products don't know well about DMB AD and then think DMB as cellular phone. In order to investigate perceptions of DMB as well as other digital instruments, we apply Proxscal analysis, Multidimensional Scaling technique at SPSS statistical package. At first step, subjects are presented 21 pairs of 7 digital instruments and evaluate similarity judgments on 7 point scale. And for each segment, their similarity judgments are averaged and similarity matrix is made. Secondly, Proxscal analysis of segment A and B are done. At third stage, get similarity judgment between DMB and other digital instruments after AD exposure. Lastly, similarity judgments of group A-1, A-2, B-1, and B-2 are named as 'after DMB' and put them into matrix made at the first stage. Then apply Proxscal analysis on these matrixes and check the positional difference of DMB and after DMB. The results show that map of segment A, who perceives DMB similar as TV, shows that DMB position closer to TV than to Cellular phone as expected. Map of segment B, who perceive DMB similar as cellular phone shows that DMB position closer to Cellular phone than to TV as expected. Stress value and R-square is acceptable. And, change results after stimuli, manipulated Advertising show that AD makes DMB perception bent toward Cellular phone when Cellular phone-like AD is exposed, and that DMB positioning move towards Car-TV which is more personalized one when TV-like AD is exposed. It is true for both segment, A and B, consistently. Furthermore, the paper apply correspondence analysis to the same data and find almost the same results. The paper answers two main research questions. The first one is that perception about a new product is made mainly from prior experience. And the second one is that AD is effective in changing and enforcing perception. In addition to above, we extend perception change to purchase intention. Purchase intention is high when AD enforces original perception. AD that shows DMB like TV makes worst intention. This paper has limitations and issues to be pursed in near future. Methodologically, current methodology can't provide statistical test on the perceptual change, since classical MDS models, like Proxscal and correspondence analysis are not probability models. So, a new probability MDS model for testing hypothesis about configuration needs to be developed. Next, advertising message needs to be developed more rigorously from theoretical and managerial perspective. Also experimental procedure could be improved for more realistic data collection. For example, web-based experiment and real product stimuli and multimedia presentation could be employed. Or, one can display products together in simulated shop. In addition, demand and social desirability threats of internal validity could influence on the results. In order to handle the threats, results of the model-intended advertising and other "pseudo" advertising could be compared. Furthermore, one can try various level of innovativeness in order to check whether it make any different results (cf. Moon 2006). In addition, if one can create hypothetical product that is really innovative and new for research, it helps to make a vacant impression status and then to study how to form impression in more rigorous way.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF