• Title/Summary/Keyword: $SO_2$ Removal

Search Result 1,086, Processing Time 0.024 seconds

The removal of lead ion by crab shell from aqueous solution (게껍질에 의한 수중의 납 이온 제거)

  • 김동석
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.361-366
    • /
    • 2002
  • Several effects on Pb$^{2+}$ removal by crab shell from aqueous solution were investigated. As the increase of initial Pb$^{2+}$ concentration and decrease of initial crab shell concentration, the time required to reach an equilibrium state and the residual Pb$^{2+}$ concentration increased. In our experimental ranges, the optimum initial Pb$^{2+}$ concentration and crab shell concentration were below 103 mg/$\ell$ and over 0.5 mg/$\ell$, respectively. Also, in order to investigate the mechanism of Pb$^{2+}$ removal by crab shell in aqueous solution, the crab shell was compared with chitosan and chitin on aspects of Pb$^{2+}$ removal capacity and Pb$^{2+}$ removal rate. The Pb$^{2+}$ removal by crab shell was greater than that by chitin and chitosan. The role of chitin was not so great in Pb$^{2+}$ removal by crab shell. The Pb$^{2+}$ removal by chitosan was not exactly correlated to the molecular weight of chitosan. weight of chitosan.

Effect of SO2 Concentration on NOx Removal Efficiency in NaOH-Based Wet Scrubbing (NaOH를 이용한 배기가스의 습식 스크러빙에서 SO2 농도에 따른 NOx 제거효율)

  • Kang, Myung Soo;Hwang, Jungho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.5
    • /
    • pp.659-667
    • /
    • 2018
  • $NO_x$ and $SO_2$ are mainly generated in the combustion of fossil fuels, and they cause secondary aerosol formation and acid rain in the atmosphere. Many studies have been conducted on the wet scrubbing process which can simultaneously reduce $NO_x$ and $SO_2$ at relatively low temperature. In this study, we conducted an experimental study on wet scrubbing by using NaOH solution. Especially, this study focuses on $NO_x$ and $SO_2$ removal characteristics by varying $NO_2/NO_x$ ratio and $SO_2$ concentration.

Washout Removal Efficiencies of Major Air Pollutants by Precipitation

  • Kim, Dong-Sool;Lim, Deuk-Yong;Heo, Jeong-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.97-106
    • /
    • 2002
  • The purpose of this study was to quantitatively estimate the washout removal efficiencies of criteria air pollutants such as SO$_2$, TSP, PM10, CO, NO$_2$, and O$_3$corresponding to the amounts and durations of precipitation. The removal patters by washout were studied with air pollutants data and the corresponding precipitation data in Seoul, Korea during the periods of 1990 to 1999. In addition, washout patterns were classified into four seasons and four time Bones, i.e., night, morning, afternoon, and evening. In this study, natures of air pollutants by sequential precipitation were also intensively studied by examining the linear relationships between removal efficiencies and the amounts and durations of precipitation for each pollutant. The results of this study showed that SO$_2$, TSP, and O$_3$were rapidly removed by initial precipitation; however, NO$_2$was slowly removed 2-hour after precipitation. Both CO and PM10 were weakly removed by washout and their removal patters showed to be irregular.

Simultaneous Removal of Hydrogen Sulfide and Ammonia Using Thiobacillus sp. IW in a Three-Phase Fluidized-Bed Bioreactor

  • Kum, Sung-Hoon;Oh, Kwang-Joong;Moon, Jong-Hae;Kim, Dong-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • v.10 no.3
    • /
    • pp.419-422
    • /
    • 2000
  • A three-phase fluidized-bed bioreactor including Thiobacillus sp. IW was tested to remove H_2S and $NH_3$ simultaneously. The inlet $H_2S$ was oxidized to $SO_4^{2-}$ by Thiobacillus sp. IW, and the $NH_3$ reacted with the $SO_4^{2-}$ to form $(NH_4)_2SO_4$. The removal efficiency of $H_2S$ was 98.4-99.9% for an inlet concentration of 36-730 ppm and that of $NH_3$ was 60.2-99.2% for an inlet concentration of 45-412 ppm. The removal efficiency of $NH_3$ was reduced when the inlet loading rate of $NH_3$ was increased above 10 mg/l/h. When the bioreactor was operated for 25 days with a lower inlet concentration of $NH_3$ compared with the of $H_2S$, the bioreactor exhibited an excellent performance with a stable pH, dissolved oxygen content, and cell concentration.

  • PDF

Turbidity Removal of Kaolin in an Electrocoagulation/Flotation Process Using a Mesh-type Aluminum Electrode (메시형 알루미늄 전극을 이용한 전기응집/부상 공정에서 Kaoline의 탁도 제거)

  • Zheng, Chang;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.26 no.5
    • /
    • pp.563-572
    • /
    • 2017
  • The Electrocoagulation-Flotation (ECF) process has great potential in wastewater treatment. ECF technology is effective in the removal of colloidal particles, oil-water emulsion, organic pollutants such as microalgae, and heavy metals. Numerous studies have been conducted on ECF; however, many of them used a conventional plate-type aluminum anode. In this study, we determined the effect of changing operational parameters such as power supply time, applied current, NaCl concentration, and pH on the turbidity removal efficiency of kaoline. We also determined the effects of different electrolyte types (NaCl, $MgSO_4$, $CaCl_2$, $Na_2SO_4$, and tap water), as well as the differences caused by using a plate-type and mesh-type aluminum anode, on the turbidity removal efficiency. The results showed that the optimal values of ECF time, applied current, NaCl concentration, and pH were 5 min, 0.35 A, 0.4 g/L NaCl in distilled water, and pH 7, respectively. The results also revealed that the turbidity removal efficiency of kaoline in different electrolytes decreased in the following sequence, given the same conductivity: tap water > $CaCl_2$ > $MgSO_4$ > NaCl > $Na_2SO_4$. The turbidity removal efficiency of the mesh-type aluminum anode was significantly greater than the plate-type aluminum anode.

Removal of Cobalt ion by Foam Flotation(I): Precipitate Flotation (거품부상법을 이용한 코발트이온제거(I): 침전부상법)

  • Jung, In Ha;Park, Hee Seoung;Moon, Je Sun;Yim, Sung Paal;Bae, Ki Kwang
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.41-45
    • /
    • 1999
  • Simulated liquid waste containing 50 ppm cobalt ion was treated by precipitate flotation using the surfactant of sodium lauryl sulfate. The effects of initial cobalt ion concentration, pH, surfactant concentration, removal time, gas flow rate and foreign ions were estimated on removal efficiency. 35% $H_2O_2$ was added for pre-treatment stage before precipitate flotation. As the result of pre-treatment, optimum removal pH and the pH of treated water being discharged were lowed and optimum removal pH range was broadened. For the result of this experiment, 99.8% removal efficiency was obtained at the condition of 50ppm of initial cobalt ion concentration, pH 9.5, 70 mL/min of gas flow rate, and 30 min of removal time. Attraction between precipitate and surfactant was supposed to be influenced by solubility and chemical affinity among species in sloution as well as zeta potential. The influence of foreign ions such as, $NO_3{^-}$, ${SO_4}^{-2}$, $Na^+$, $Ca^{+2}$ on the removal efficiency was also observed. Removal efficiency by precipitate flotation containing 0.1 M of ${SO_4}^{-2}$ ion decreased to 90% due to the decrease of zeta potential and interruption of precipitation.

  • PDF

Non-thermal Plasma Process for simultaneous removal of SO2/NOx from a Sintering Plant of Steel Works

  • Nam, Chang-Mo;Mok, Young-Sun;Kwon, Gi-Hong;Suh, You-Duck;Cho, Byeung-Rak
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.1
    • /
    • pp.81-86
    • /
    • 2003
  • For the simultaneous removal of $SO_2$/NOx from an iron-ore sintering plant, industrial plasma experiments have been conducted with a flue gas flow rate of $5,000Nm^3/hr$. The maximum 40kW power using the magnetic pulse compression (MPC) system generates a peak value of 100-150kV pulse voltage with its risetime of 200nsec and full width at half maximum (FWHM) of 500nsec, and with a frequency <300Hz. The plasma reactor module adopts a wire-plate structure with a gap of 200-400mm ID between plates. Initial concentrations of $SO_2$ and NOx were around 100-150ppm, respectively in the presence of 15% $O_2$ and <10% $H_2O$. Various reaction parameters such as specific energy ($Whr/Nm^3$), $NH_3$ injection with corona discharge, flow rate and injection of hydrocarbons were investigated for $SO_2$/NOx removal characteristics. About 90/65% of $SO_2$/NOx were simultaneously removed with a specific energy of $3.0Whr/Nm^3$ when both $NH_3$ and hydrocarbons were injected. Practical implications that the pilot-scale plasma results provide are further discussed.

  • PDF

Absorption Characteristics of Sulfur Dioxide in Jet Bubbling Reactor (가스분사반응기에서의 SO2 흡수 특성)

  • Choi, Byung-Sun;Park, Seung-Soo;Kim, Yung-whan
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.836-842
    • /
    • 1994
  • The optimum design conditions of gas sparger pipe and the effects of operating variables on $SO_2$ removal efficiency have been examined in Jet Bubbling Reactor. Geometry of gas sparser pipe of Jet Bubbling Reactor is a very important factor to obtain a effective gas-liquid contact. Test results revealed that Reynolds numbers at sparger and slot have to be kept greater than 12,000 identically at a given gas velocity. $SO_2$ removal efficiency was a function of ${\Delta}P$, pH, inlet $SO_2$ concentration and particle size of limestone and was more sensitive to the change of ${\Delta}P$ than to the changes of others. The ${\Delta}P$ of at least 230mmAq must be maintained to acheive the above 90% $SO_2$ removal at pH of 4.0 which is considered as adequate operating pH. Higher $SO_2$ removal efficiency was obtained even at lower pH ranges, which resulted from the complete oxidation of the absorbed $SO_2$ to sulfates by adding air and consequently from the reduction of $SO_2$ equillibrium partial pressure in the gas-liquid interface The 99.5% of the limestone utilization was attained in pH range from 3.0 to 5.0 with regardless to the particle size of limestone employed.

  • PDF

Removal Effect of Acid Gases by Reactant Mixer and Distributor of Bag Filter in Dry Scrubbing with NaHCO3 (중탄산나트륨 건식공정에서 반응제 혼합 장치 및 백필터 분배장치에 의한 산성가스 제거 영향)

  • Lee, Young-Man;Kwak, Yeon-Ho;Bae, Woo-Keun;Kwon, Ki-Wook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.402-409
    • /
    • 2009
  • Sodium bicarbonate ($NaHCO_3$) was used as a reactant for the removal of acid gases from a waste incinerator. The removal efficiencies of HCl and $SO_x$ were tested with a reactant mixing apparatus and a distributor installed at the bag filter inlet. It was shown that the stoichiometric ratio of $NaHCO_3$ to the acid gases which allows a removal of over 90% for both HCl and $SO_2$ was about 1.2. When a reactant mixing apparatus was installed on the duct, the removal efficiencies of HCl and $SO_2$ at the end of the duct were increased by approximately 1.5 and 3 times respectively, compared to when the apparatus was not installed. At the end of the bag filter, the removal efficiencies of the both were as high as 98% with a stoichiometric ratio of 1.35. Installing a reactant mixing apparatus on the duct and a distributor at the entrance of the bag filter and using $NaHCO_3$ as a reactant helped overcome the problem of low removal efficiencies of acid gases by dry scrubbing.

Simultaneous Removal Characteristics of NOx, SOx from Combustion Gases using Plasma Chemical Reaction (플라즈마 화학반응에 의한 연소가스 중 NOx. SOx 동시제거 특성)

  • 박재윤;고용술;이재동;손성도;박상현;고희석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.406-409
    • /
    • 1999
  • Experimental Investigations were carried out to remove NOx, SOx simultaneously from simulated flue gas[NO(0.02%)-SO$_2$(0.08%)-$CO_2$-Air-$N_2$] by using a plasma chemical reaction. Ammonia gas(14.81%) balanced by argon was diluted by all and was Introduced to mall simulated flue gas duct through NH$_3$ Injection system which is in downstream of reactor. The NH$_3$ molecular ratio(MR) was determined based on (NH3) to [NO+S0$_2$]. MR is 1, 1.5, 2.5. The NOx removal rate significantly increased with increasing NaOH bubble quantity. The SO$_2$ removal rate was not significantly effected by applied voltage, however it fairly Increased with increasing NH$_3$ molecule ratio. By-product aerosol particle was observed by XRD(X-ray diffraction) after sampling, The NOx, SOx removal rates, when H2O vapour bubbled by dry all was injected to plasma reactor, were better than those of other cases. When aqueous NaOH solution(20%) bubbled by 2.5( ι /min) of $N_2$ and 0.5 ( ι /min) NH$_3$(MR=1.5) were injected to simulated flue gas, The NOx. SOx removal rate was 95 ~ 100[%]

  • PDF