• Title/Summary/Keyword: $SO_{2}$ Removal Efficiency

Search Result 370, Processing Time 0.026 seconds

The Characteristics of the Treatment of Pollutants ($SO_2$, NOx) Using Surface Discharge Induced Plasma Chemical Process (SPCP를 이용한 오염물질 ($SO_2$, NOx) 처리 특성)

  • 봉춘근;부문자
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.333-342
    • /
    • 1998
  • Plasma process has great possibilities to remove SOx, NOx simultaneously with high treatment efficiency and is expected to be suitable for small or middle plants. It was accomplished to evaluate SO2, NOx control possibility and achieve basic data to control pollutants by use of Surface Discharge Induced Plasma Chemical Process (SPCP) in this study. O3 generation characteristics by discharge of a plate was proportional to O2 concentration and power consumption and inversely proportional to temperature and humidity, In case of dry air, NOx was highly generated by N2 and O2 in air during the plasma discharge process but it was decreased considerably as H2O was added. SO2 removal efficiency was very high, and removal rate was 170,350 mEA at 30,50 watt respectively in flue gas which is usually contain HIO. NOx removal efficiency was about 57% at 40 watt power consumption with 7.5% humidity. It is estimated that H2O has an important role in reaction mechanism with pollutants according to plasma discharge.

  • PDF

A study on desulfurization by anthracite - bituminous coal blend combustion in a fluidized bed combustor --- A desulfurization using waste paper sludge --- (유동층연소로에서 유,무연탄 혼합연소시 탈황에 관한 연구 --- 폐제지슬러지를 이용한 황산화물 제어 ---)

  • Cho, Sang-Won;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.3 no.1
    • /
    • pp.96-105
    • /
    • 1997
  • The objectives of this study were to investigate $SO_2$ removal efficiency of anthracite - bituminous coal blend combustion in a fludized bed coal combustor with Ca/S, anthracite ratio, bed temperature, and waste paper sludge particle size. The experimental results were presented as follow ; the effect of the desulfurization by the particle size of waste paper sludge was a great and $SO_2$ removal efficiency was heigest in paper sludge dia $1016{\mu}m$. And the difference of $SO_2$ removal efficiency according to air velocity was not too large. As Ca/S mole ratio incresed, $SO_2$ removal efficiency incresed rapidly up to Ca/S mole ratio 3 while the desulfurization rates did not increse too largely in the range of more than the level. The bed temperature had a great deal of effect on the desulfurization rate. So the $SO_2$ removal efficiency was a graet using waste paper sludge that the properbility of paper sludge as sorbent was conformed.

  • PDF

Removal of Heavy Metals in Wastewater Using Glycine max Merr (콩을 이용한 식물filter에 의한 중금속 제거에 관한 연구)

  • 나규환;김순진;신정식;최한영;이장훈
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.105-108
    • /
    • 1997
  • For the removal of heavy metals, Cd, Cu and Cr were used. The initial concentration of Cd and Cu were 1-10 ppm, the removal efficiency of Cd and Cu was 76.2-89.0% and 69.0-79.0%, respectively. The initial concentration of Cr were 1~5 ppm, and the-removal efficiency was low especially at high concentration. In general, the initial concentrations of heavy metals had no relation to the removal efficiency. At the beginning, the removal efficiency was very high, but it was maintained at constant concentration. The trends of accumulations of heavy metals in the stem increased in proportion to the initial concentration. The removal efficiency of heavy metals increased a little bit when nutrients existed in the solution. So that, the initial concentration of Cd and Cu were 1-10 ppm, the removal efficiency of Cd and Cu was 84.8-91.0% and 75.9-82.0%. The initial concentration of Cr were 1-5 ppm, the removal efficiency was 25.0-67.0%.

  • PDF

NO Removal Efficiency by Pulsed Corona Discharge Process at Room Temperature (상온 펄스 코로나 방전 공정에 의한 NO 제거 효율)

  • 김동주;박정환;김교선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.337-344
    • /
    • 2002
  • In this study, we analyzed the NO removal efficiency by the pulsed corona discharge process and investigated the effects of several process variables such as initial concentrations of NO, $H_2O$, and NH$_3$, applied voltage, pulse frequency, diameter of the discharge electrode, and residence time. The removal efficiency of NO increased by the addition of $H_2O$ or NH$_3$, but the changes of initial NH$_3$ and $H_2O$ concentrations did not affect the removal efficiency of NO significantly. With the increases of the applied voltage or the residence time, the removal efficiency of NO increased. In addition, with the increases of the pulse frequency of applied voltage, or the diameter of the discharge electrode, the removal efficiency of NO increased. The experimental results can be used as a basis to design the pulsed corona discharge process to remove NO$_{x}$, SO$_{x}$ and VOCs.OCs.

Preparation of Porous Lime Filters and SOx Removal Characteristics (석회질 다공성 필터 제조 및 SOx 제거 특성)

  • Lee Kwanghee;Park Jaikoo;Kim Hyunjung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.153-159
    • /
    • 2004
  • This study was focused on evaluating physical properties and SO$_{x}$ removal capability of porous lime filters prepared by a foaming and a gelcasting method. Porosities of lime filters ranged from 55% to 85%, and their mean pore sizes were about 95 ${\mu}{\textrm}{m}$. It was observed that porous lime filters had the continuous pore structure that most pores were inter-connected by many windows. Before SO$_{x}$ removal reaction a surface of porous lime filters was made up of calcium oxide, but after reaction calcium sulfate became a main component. The SO$_{x}$ removal efficiency and the conversion ratio of calcium oxide to calcium sulfate increased according to reaction temperature and porosity. At 100$0^{\circ}C$, SO$_{x}$ removal efficiency of filters was always over 98% regardless of the porosity. In case of the filter with the porosity of 85%, the conversion ratios of calcium oxide increased according to the reaction temperature, and they were in the range 30% to 60%. to 60%.

Development of Pilot-Scale Scrubber for Simultaneous Removal of $SO_2/NO$

  • Jung, Seung-Ho;Jeong, Gwi-Taek;Lee, Gwang-Yeon;Park, Don-Hee;Cha, Jin-Myeong
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.468-474
    • /
    • 2005
  • SOx and NOx are known major precursors of acid rain and thus the abatement of their emissions is a major target in air pollution control. To obtain basic data on the removal process of simultaneous $SO_2/NO$, the optimal reaction condition and the composition of reaction solution for simultaneous removal of $SO_2/NO$, ware investigated using a bubble column reactor. Pilot scrubber was consisted of scrubber, filter and control box. Dust removal rate was 83, 92, and 97% with catalyst flux of 0.5, 0.8, 1.5 L/min, respectively Average dust removal efficiency with a kind of nozzle was about 94 and 90% in STS FF6.5 (5/8in.) and 14 of P.P W(1.0in.), respectively Dust and $SO_2$ were removed more than 98-96% regardless of reactor number. In the case of NO gas, removal yield of 83.3% was achieved after 48 hours in 1 stage, also removal yield of 95.7% was reached in 2 stages. In tile case of application of STS (5/8 in.) and P.P (1.0 in.) as used fill packing, removal efficiency was reached higher than 98% without related to of kind of fill packing.

  • PDF

[Retracted]Gas Mask Removal Efficiency of CO, HCl, HCN, and SO2 Gas Produced by Fire ([논문철회]화재용 방독면의 CO, HCl, HCN, SO2 연소생성물 제거효율)

  • Kong, Ha-Sung;Gong, Ye-Som;Kim, Sang-Heon
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.57-60
    • /
    • 2015
  • The removal efficiencies by elastic fire gas mask of toxic gases CO, HCl, HCN, and $SO_2$ produced by a fire have a key role in saving lives. The elastic fire gas mask comprises a visible window, elastic hood, gas purification canister, and air vent. It does not have hair or neck thongs, which makes it easy to use and put on quickly. This research examined the removal efficiency of toxic gases by such a mask. The removal efficiencies for CO with a background concentration of 2505.0 ppm were 99.99 and 99.98% after 3.5 and 8.5 min, respectively. The residual CO concentration was drastically increased after 8.5 min. The removal efficiencies for HCl, HCN, and $SO_2$ with background concentrations of 1003.0, 399.0, and 100.3 ppm, respectively, were 100% after 20 min.

Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor (실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구)

  • 동종인;구우회;임대현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

Bisphenol-A Removal in Conventional Water Treatment Systems (정수처리공정에서 bisphenol-A의 제거에 관한 연구)

  • 김혜리;이윤진;박선구;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.59-64
    • /
    • 2004
  • This study was carried out to investigate influencing factors of bisphenol A(BPA) removal characteristic in conventional water treatment systems to be connected with coagulation, sedimentation, filtration and disinfection. The result are summarized as follows; In BPA removal, optimal doses of PAC, alum, ferric chloride were 7.5 mg Al/L, 10.0 mg AI/L, 15.0 mg Fek. PAC was most effective coagulant to remove BPA. In coagulation process, BPA removal efficiency were increased about 2% by adjusting pH of raw water as 6. At temperature rise 1$0^{\circ}C$, BPA removal efficiency were increased 0.94%. but BPA removal efficiency in sand filtration process were under 1 %ie, so that BPA was almost not removed. At free chlorine dose 1, 2 mg/L, the reaction rate constant k in the BPA removal have been calculated to be 0.397, 0.953 min$^{-1}$ . At free chlorine dose 1, 2 mg/1-, degradation reaction of BPA was completed during 10 min and BFA removal efficiencies were 97.66, 99.99% at this time.

The Nutrients Removal in Aerobic High Rate Ponds Through the Lighting Period (빛의 조사기간으로 본 호기성 고율 안정조 프로세스의 영양물질 제거)

  • 공석기
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.83-91
    • /
    • 1996
  • It is not too much to say that the territorial inhabitants' concerns are wholly c concentrated on the environmental preservation-problem and development-problem in Korea given effect to the local self-government system. At a time like this I was studied the effect on nutrients removal through lighting period in aerobic high rate pond and we know that waste stabilization pond method is the most economical and energy saving wastewater treatment technology than others. At the results which was studied through operating the reactor-l artifically main-tained at a temperature, $25^{\circ}C$, a light intensity, 3000lux, and a lighting period, 24hrs and the reactor-2 artifically maintained at a tern야rature, $25^{\circ}C$ and a light intensity 3000lux, and a lighting period period, 12hrs, It has appeared for 24hrs.-lighting period -reactor-1 to be prior to the reactor-2. The attained results are that 1. reactor-1 is prior to reactor-2 on oxygen-generation 2. reactor-1 is prior to reactor-2 on algal production 3. COD removal efficiency, 90.76%, T-N removal efficiency, 80%, T-P removal e efficiency, 74.47 % in reactor-2, in reactor-1 COD removal efficiency, 94.85 %, T-N removal efficiency, 98.07%, T-P removal efficiency, 72.13% are, so the treatment efficiency of reactor-1 is more excellent than things of reactor-2 4. it appeared that the detention time is 8, 9days.

  • PDF