• 제목/요약/키워드: $SF_6-N_2$ mixtures

검색결과 58건 처리시간 0.024초

고기압하에서 $SF_{6}$ 혼합 가스 ($SF_{6}$/$N_{2}$)의 절연파괴에 대한 연구 (A study on the electrical breakdown in pressurized ($SF_{6}$/$N_{2}$) mixtures)

  • 이동인;이달해
    • 전기의세계
    • /
    • 제28권4호
    • /
    • pp.39-46
    • /
    • 1979
  • The effective ionization coefficient in $SF_{6}$/$N_{2}$ mixtures was attempted to derive from the pure gases. Measurements of static breakdown voltage were made under the uniform field at pressures up to 4 bar in order to compare with the results obtained from this assumption. The relative performance of $SF_{6}$/$N_{2}$ mixtures to pure $SF_{6}$ was also investigated. The effect of surface roughness on discharge thresholds in $SF_{6}$/$N_{2}$ mixtures was calculated employing the simplified model and mesurements of breakdown voltages for a gap with an artificial protrustion were also made. The experimental results show that the effective ionization coefficient in gas mixtures can not be reliably estimated from the values measured for the pure gases. Therefore, basic parameters for $SF_{6}$/$N_{2}$ mixtures must be measured by investigation of the mixtures themselves. The relative performance of mixtures to pure $SF_{6}$ could be considered with the values of pR.

  • PDF

$SF_{6}-N_{2}$ 혼합가스에서 뇌충격전압에 의한 50[50%] Flash over 전압 및 V-t 특성 (V-t Characteristics and 50% Flash-over Voltage of $SF_{6}-N_{2}$ Mixtures for Lightening Impulse Voltage)

  • 김정달;송원표;김동의
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제7권1호
    • /
    • pp.21-29
    • /
    • 1993
  • 본 연구는 전력계통의 절연에 가장 가혹한 영향을 미치는 뇌충격 전압에 대한 50% FOV와 V-t 특성 및 코로나 진전 과정을 불평등 전계중에서 순수 $SF_6, N_2, SF_6-N_2$혼합가스 분위기에서 연구하여 SF6-N2 혼합가스의 파괴과정과 경제적 실용 가능성에 대해서 검토하였다. 실험결과 $SF_6$ 50%-$N_2$ 50% 혼합가스의 50% FOV는 순수 $SF_6$의 80%보다 높다. 또 V-t 특성의 측정치와 등면적 법칙으로 계산된 곡선은 각 경우에 일치했다. 따라서 순수 $SF_6$에 대한 경제적 대체가스로서 SF6 50%-$N_2$ 50% 혼합가스가 사용되어질 수 있다는 것을 알 수 있었다. 또한 방전 도형을 이용한 코로나 진전과정 분석으로 이를 입증했다.

  • PDF

불평등전장에서 $SF_6$$SF_6/N_2$ 혼합기체의 뇌임펄스 전압에 대한 코로나 방전특성 (Characteristics of lightning impulse corona discharges under non-uniform electric fields in $SF_6$ and $SF_6/N_2$ mixtures)

  • 이복희;오성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.129-132
    • /
    • 2004
  • This paper presents an experimental study on the prebreakdown characteristics in $SF_6/N_2$ mixtures under non-uniform electric fields when subjected to the positive and negative lightning impulse voltages. $SF_6/N_2$ mixtures have a merit of an environmental aspect and cost reduction, and safty aspects. In order to analyze the prebreakdown processes in $SF_6/N_2$ mixtures stressed by impulse voltages, prebreakdown current and light were observed by a shunt with high sensitivity and a photo-multiplier tube, respectively. Additionally, characteristics of luminous events in flashovers were discussed.

  • PDF

SF6및 SF6-N2 가스 중에서 직류전동에 \ulcorner나 스페이서 연면간락에 관한 연구 (A Study on the Flashover along the Spacer Surface SF6-N2 Gas Mixtures Stressed by D.C)

  • 김정달;정재길;이동인
    • 대한전기학회논문지
    • /
    • 제36권11호
    • /
    • pp.796-805
    • /
    • 1987
  • The flashover voltages have been investigated for spacer and unbridged-gap in SF6-N2 gas mixtures up to the value of 760(torr. cm), The gap was stressed by DC source The results obtained are as follows` 1) The flashover voltages for an unbridged gap and for a spacer in SF6, N2 and SF6-N2 gas mixtures follow the Paschen's curve. 2) The polarity effects was not observed in both unbridged gap and a spacer which had per ect contact with an electrode. The flashover voltages for negative polatity are lower than those for positive polarity in case of imperfect contact. 3) 3%flashover voltage is decreased by putting a spacer which had perfect contact with an electrode. The spacer which has a gap void shows the lowest flashover voltage. 4) The lowest spacer efficiency was obtained with higher gas pressure & large amount of N2 content. The flashover voltages depend on the gas pressure rather than the spacer efficienty at low value of pd. 5) The flashover voltages of gas mixtures of N2 with SF6 are relatively high, even though the amount of SF6 gas content is small.

  • PDF

$SF_6-N_2$ 혼합가스의 절연특성에 미치는 파티클의 영향 (The effect of particle on insulation Characteristic of $SF_6-N_2$ Mixtures)

  • 이곤;이동준;이강수;김경화;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2383-2385
    • /
    • 1999
  • This paper describes the effect of particles on insulation characteristics of $SF_6-N_2$ mixtures such as breakdown voltages, lift-off voltages and maximum discharge. As a result, the breakdown voltage was increased with the increment of $SF_6$ and the mixture containing 20[%] of $SF_6$ has a breakdown voltage ratio factor better than the other mixtures. The lift-off voltage was nearly constant with all mixtures. Discharge was decreased with the increment of $SF_6$.

  • PDF

불평등 전계에서 SF6/N2 혼합가스의 AC 절연파괴전압 시뮬레이션 및 실험값와의 비교 (AC Breakdown Voltage Simulation of SF6/N2 Mixture in Non-Uniform Field and Its Comparison with Experimental Values)

  • 이병택;황청호;이태호;허창수;장용무
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1416-1422
    • /
    • 2010
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. At present study the breakdown characteristics of $SF_6/N_2$ mixtures in Non-uniform field was performed. In this paper, The simulation value are compared with experiment values. Streamer breakdown criterion was used for predicting breakdown voltage. For accurate simulation this simulation apply utilization factor using CST(computer simulation technology) EM $studio^{tm}$ program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. The pressure range of gas mixtures was 0.4 MPa to 0.7 MPa. The rod-plane was used and mixture ratio is $SF_6$ 20% : $N_2$ 80%. The gap lengths are 10mm to 70mm. As the pressure increase, this simulation value does not correspond to the experiment value. So this simulation need surface roughness factor. As a result of applying surface roughness factor this simulation decrease a relative error (|experiment value - simulation value| /simulation value).

불평등전계 중에서 $SF_{6}-N_{2}$ 혼합기체의 절연파괴 특성 (Breakdown Characteristics of $SF_{6}-N_{2}$ Mixtures in Nonuniform electric Field)

  • 이복희;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1999-2001
    • /
    • 2000
  • Impulse breakdown voltage characteristics of sulphur-hexafluoride/nitrogen ($SF_{6}-N_{2}$) mixtures were presented. The applied voltages were the positive and negative lightning impulse (1.2/44${\mu}s$) and oscillating impulse ($0.4{\mu}s$/2.08MHz) voltages. The predischarge current was observed to clarify the breakdown mechanism. The electrode system was consisted of plane to plane configuration with a needle-shaped protrusion whose length and diameter are 10mm and 1mm. The measurements were carried out at the gas pressure of mixtures up to 0.5MPa with nitrogen concentrations varying from 5 to 20%. The electrical breakdown in $SF_{6}-N_{2}$ mixtures develops with steplike pulses in leader mechanism. The minimum breakdown voltages for the negative lightning and oscillating impulse voltages were higher than those for the positive.

  • PDF

$SF_6-N_2$ 혼합가스의 정.부극성 뇌충격전압에 대한 50% FOV와 V-t 특성 (50% Flashover Voltage and V-t Characteristics for $SF_6-N_2$ Mixtures under Positive & Negative Ligtning Impulse Voltage)

  • 송원표;김정달;고희석;김동의;권영한;조규복;이철현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.300-303
    • /
    • 1991
  • Sulphur-hexafluoride has extensively been used as an insulating gas of electric power equipment in substation for its high dielectric strength, non-toixity and non-flammable properties. But it is very expensive and is liquidizable under the condition of low temperature and high pressure. And it is very sensible to the locally high electric field strength. To resolve these problems, we studied 50% FOV and V-t characteristics of $SF_6-N_2$ mixtures under positive and negative lightning impulses using a 25mm rod-plane gap. 50% FOV of $SF_6-N_2$ 50% mixture was about 85% of pure $SF_6$ and it was known that $SF_6-N_2$ mixtures can be used as an economic substitution insulating gas for $SF_6$.

  • PDF

$SF_6+Ar$ 혼합기체의 MCS-BE 알고리즘에 의한 전자에너지 분포함수 (A Study on the Electron Energy Distribution Function in $SF_6+Ar$ Mixtures Gas used by MCS-BE Algorithm)

  • 김상남;하성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.17-21
    • /
    • 2000
  • A Study on the electron energy distribution function in $SF_6+Ar$ mixtures gas used by MCS-BE algorithm, the electron swam parameters in the 0.5% and 0.2% $SF_6+Ar$ mixtures are measured by time of flight method over the E/N(Td) range from 30 to 300(Td). A two-term approximation of the Boltzmann equation analysis and Monte Carlo simulation have been also used to study electron transport coefficients. The electron energy distribution function has been analysed in $SF_6$ gas and $SF_6+Ar$ mixtures at E/N : 200(Td) for a case of the equilibrium region in the mean electron energy. The measured results and the calculated results have been compared each other.

  • PDF

불평등 전계에서 $SF_6/N_2$의 초고압 AC전압 절연내력 시뮬레이션

  • 허창수;이병택;최순호;심명섭;안정식;황청호;장용무
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.37-37
    • /
    • 2010
  • In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. In this paper, breakdown experiment values and breakdown simulation value are compared. Streamer theory was used for predicting breakdown voltage. For accurate simulation, this simulation apply utilization factor using CST program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. But with gap lengths increasing, the breakdown voltage is saturated. So simulation need surface roughness factor.

  • PDF