• Title/Summary/Keyword: $PCl_5$

Search Result 127, Processing Time 0.032 seconds

Development of Conductive Polycaprolactone (PCL)-resin based on Reduced Graphene Oxide(rGO)/Polypyrrole (Ppy) composite for 3D-printing application (3D 프린팅 응용을 위한 환원그래핀/폴리피롤 복합체 기반의 전도성 폴리카프로락톤 레진의 개발)

  • Jeong, Hyeon Taek;Jung, Hwa Yong;Cho, Young Kwang;Kim, Chang Hyeon;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.935-939
    • /
    • 2018
  • 3D Printing technology is developing in various prototypes for medical treatment, food, fashion as well as machinery and equipment parts production. 3D printing technology is also able to fully be utilized to other industries in terms of developing its technology which has been reported in many field of areas. 3D printing technology is expected to be used in various applications related to $4^{th}$ industrial revolution such as finished products and parts even it is still carried out in the prototype model. In this study, we have investigated and developed conductive resin for 3d printing application based on reduced graphene oxide(rGO)/Polypyrrole(Ppy) composite and polycaprolactone(PCL) as a biodegradable polymer. The electrical properties and surface morphology of the conductive PCL resin based on therGO/Ppy composite were analyzed by 4point-probe and scanning electron microscope(SEM). The conductive PCL resin based on rGO/Ppy composite is expected to be applicable not only 3D printing, but also electronic materials in other industrial fields.

Preparations and Release Property of Poly(ε-caprolacton)/ethyl cellulose Microcapsule Containing Pluronic F127 (Pluronic F127을 함유하는 Poly(ε-caprolacton)/ethyl cellulose 마이크로 캡슐의 제조 및 방출 특성)

  • Hong, Yeon Ji;Kim, Jin-Chul
    • Applied Chemistry for Engineering
    • /
    • v.20 no.6
    • /
    • pp.632-637
    • /
    • 2009
  • Poly(${\varepsilon}-caprolacton$)/ethyl cellulose (PCL/EC) microcapsules containing pluronic F127 were prepared by a spray drying method. The aqueous phase, 20% of pluronic F127 was dissolved in distilled water, and the organic phase, 5% of PCL and EC were dissolved in dichloromethane. The microcapsules were obtained by spray drying the water-in-oil (W/O) emulsion. According to the data of scanning electron microscopy and particle analyzer, tens of micro size microcapsules were observed. On a differential scanning calorimeter, the phase transition temperatures of microcapsules were observed and they were found around those of pluronic F127 and poly(${\varepsilon}-caprolacton$), which were the main components of the microcapsules. At the range of $30{\sim}45^{\circ}C$, temperature-dependent release properties were investigated using fluorescein isothicyanate-dextran (FITC-dextran) and blue dextran as a model drug. When the temperature was increased, the degree of release of microcapsule was also increased. FITC-dextran, the relative low molecular weight, was more released than blue-dextran.

Raw Spectrum Analysis of operated UHF-Wind Profiler Radar in South Korea (국내 운용 UHF-윈드프로파일러 레이더의 원시 스펙트럼 분석)

  • Lee, Kyung-Hun;Kwon, Byung-Hyuk;Kim, Yu-Jin;Lee, Geon-Myeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.767-774
    • /
    • 2022
  • In this paper raw spectrum data were analyzed to suggest the moving forward of performance evaluation and quality control of wind profilers of four manufacturers operating in South Korea. For the analysis, the profile of the spectrum averaged by season and the profile of four statistical values (minimum, average, median, and maximum) calculated by Power Spectrum Density (PSD) were used. The quality of spectrum data was the best for LAP-3000, followed by YKJ3, PCL-1300, and CLC-11-H. In Cheorwon and Chupungnyeong, where PCL-1300 was installed, the variability of the spectrum due to ground clutter and non-meteorological signals was large, so ground clutter removal and signal processing such as moving average and multi-peak were required. In Gunsan and Paju, where CLC-11-H was installed, DC (Direct Current) bias and propagation folding were found, so it is necessary to remove the DC bias and limit the effective altitude for observation.

Preparation and Physical Properties of Polycaprolactone Diol-based Water-based Polyurethanes for Split Leather Coatings (스플릿 레더 코팅을 위한 폴리 카프로 락톤 디올 기반 수성 폴리 우레탄의 제조 및 물리적 특성)

  • Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.49-55
    • /
    • 2020
  • In this study, isophorone diisocyanate (IPDI) and dimethylolbutanoic acid (DMBA) were used on the basis of poly caprolactone diol (3M, 3.5M, 4M, 4.5M) for the synthesis of water-based polyurethanes for coating on skin layers of leather. Tensile strength, elongation, and adhesive strength of the prepared samples were measured. As a result of measuring the tensile strength, the tensile strength was found to be 4.09 kgf / ㎟ when 3 moles were applied, and 1.071 kgf / ㎟ when 4.5 moles were applied. Elongation was 366 % when 3 moles of PCL were applied, and 709 % at 4.5 moles. Adhesive strength was 2.887 kgf / cm when 3 moles of PCL was applied and 0.998 kgf / cm when 4.5 moles were applied.

An Analysis of the Prevalence and Pattern Identification of Korean Medicine for Acute Stress Disorder and Post Traumatic Stress Disorder in Patients with Traffic Injuries (교통사고 상해증후군 환자의 급성 스트레스 장애와 외상 후 스트레스 장애의 유병률과 한의변증유형 분석)

  • Lee, Yu Jin;Lee, Sung Joon;Cheong, Moon Joo;Lim, Jung Hwa;Jo, Hee Geun;Kim, Bo Min;Chung, Sun-Yong;Kwak, Hui-Yong;Park, Bo Ra;Park, Tae-Yong;Shin, Byung-Cheul;Kang, Hyung Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.32 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Objectives: To investigate the prevalence of acute stress disorder (ASD) and post-traumatic stress disorder (PTSD) in patients with traffic injuries. In addition, PTSD patients was classified using 'pattern identification for jing ji and zheng chong'. Methods: Questionnaires such as the primary care PTSD screen for DSM-5(PC-PTSD-5), Korean version of PTSD checklist-5 (PCL-5-K), and the instrument of pattern identification for jing ji and zheng chong were conducted on 195 patients within 3 days to 1 year after traffic accidents. Patients were recruited from six medical institutions. Collected data were used to determine the prevalence of acute stress disorder and post-traumatic stress disorder. Results: On PC-PTSD-5, the prevalence was 39.1% for ASD and 50% for PTSD. On PCL-5-K, the prevalence was 20.4% for ASD and 29.3% for PTSD. Satisfying both PC-PTSD-5 and PCL-5-K, the prevalence was 18.2% for ASD and 25.8% for PTSD. As a result of pattern identification for jing ji and zheng chong, 'weakness of heart and gall bladder type' accounted for the highest proportions in both ASD and PTSD groups. Conclusions: In this study, the prevalence was 39.1% for ASD and 50% for PTSD by PC-PTSD-5. Satisfying both PC-PTSD-5 and PCL-5-K, the prevalence was 18.2% for ASD and 25.8% for PTSD. Further large-scale prospective studies are needed to analyze the prevalence of ASD and PTSD, the rate of progression from ASD to PTSD, and the type of pattern identification.

The Relationship between Heart Rate Variability and Symptoms in Subjects with Chronic Posttraumatic Stress Disorder (만성 외상 후 스트레스 장애 환자에서 심박변이도와 증상과의 상관관계 : 외상증상과 심박변이도 관계)

  • Park, Jinsoo;Kang, Sukhoon;Park, Joo Eon;Choi, Jin Hee;So, Hyung Seok;Kim, Kiwon;Choi, Hayun
    • Anxiety and mood
    • /
    • v.16 no.2
    • /
    • pp.83-90
    • /
    • 2020
  • Objective : Heart rate variability (HRV) is known to reflect autonomic nervous system activity. Individuals with posttraumatic stress disorder (PTSD) are reported to have lower HRVs. We attempted to find HRV indices with head up tilt position that reflect the symptoms well in order to evaluate PTSD symptoms. Methods : Sixty-seven patients with PTSD and 72 patients without PTSD were assessed using the PTSD Checklist for DSM-5 (PCL-5), the Beck Depression Inventory, the Beck Anxiety Inventory and the Pittsburgh Sleep Quality Index. HRV was measured in the head-up tilt position. We collected data regarding heart rate (HR), standard deviation of the NN intervals (SDNN), the square root of the mean squared differences of successive NN intervals (RMSSD), log low-frequency (LNLF) and log high-frequency (LNHF). Results : The value of LNHF was different according to presence or absence of PTSD after head-up tilt position. In the findings of the association between PTSD symptoms and HRV indices as based on head-up tilt, LNHF had a significant correlation with the total score of PCL-5. Conclusion : The reduction of the high-frequency component of HRVs in the PTSD group might reflect more PTSD symptoms.

Novel pH/Temperature Sensitive Hydrogels of Poly (ethylene glycol)-Poly (caprolactone) -Poly (${\beta}-amino\;ester$) (PAE-PCLA-PEGPCLA-PAE) Biodegradable Polyester Block Copolymer

  • Huynh Dai Phu;Lee Doo-Sung
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.263-263
    • /
    • 2006
  • Poly (ethylene glycol)(PEG) - Poly (${\varepsilon}-caprolactone(CL)$) - Poly (D,L lactide(LA) (PCLA-PEG-PCLA) was synthesized by ring-opening polymerization to form temperature sensitive hydrogel triblock copolymer. The triblock copolymer was acrylated by acryloyl chloride. ${\beta}-amino$ ester was used as a pH sensitive moiety, in this study ${\beta}$- amino ester obtained from 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine, it have pKb around 6.6. pH/temperature sensitive penta-block copolymer (PAE-PCL-PEG-PCL-PAE) was synthesized by addition polymerization from acrylated triblock copolymer, 1,4-butandiol diacrylate, and 4, 4' trimethylene dipiperidine. Their physicochemical properties of triblock and penta-block copolymers were characterized by $^1H-NMR$ spectroscopy and gel permeation spectroscopy. Sol-gel phase transition behavior of PAE-PCL-PEG-PCL-PAE block copolymers were investigated by remains stable method. Aqueous media of the penta-block copolymer (at 20 wt%) changed from a sol phase at pH 6.4 and $10^{\circ}C$ to a gel phase at pH 7.4 and $37^{\circ}C$. The sol-gel transition properties of these block copolymers are influenced by the hydrophobic/hydrophilic balance of the copolymers, block length, hydrophobicity, stereo-regularity of the hydrophobic of the block copolymer, and the ionization of the pH function groups in the copolymer depended on the changing of environmental pH, respectively. The degradation and the stabilization at pH 7.4 and $37^{\circ}C$, and the stabilization at pH 6.4 and $10^{\circ}C,\;5^{\circ}C,\;0^{\circ}C$, of the gel were determined. The results of toxicity experiment show that the penta block copolymer can be used for injection drug delivery system. The sol?gel transition of this block copolymer also study by in vitro test ($200{\mu}l$ aqueous solution at 20wt% polymer was injected to mouse). Insulin loading and releasing by in vitro test was investigated, the results showed that insulin can loading easily into polymer matrix and release time is around 14-16days. The PAE-PCL-PEG-PCL-PAE can be used as biomaterial for drug, protein, gene loading and delivery.

  • PDF

Influence of Surface Treatment of SiO$_2$ and Stirring Rate on Fragrant Oil Release Behavior of Poly($\varepsilon$-caprolactone) Microcapsules (실리카의 표면 처리와 교반 속도가 폴리카프로락톤 마이크로캡슐의 향유 방출 거동에 미치는 영향)

  • 박수진;양영준;이재락;서동학
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.464-469
    • /
    • 2003
  • In this work, the fragrant oil release behavior of poly($\varepsilon$-caprolactone) (PCL) microcapsules containing SiO$_2$ was investigated. The SiO$_2$ was chemically treated in 10, 20, and 30 wt% hydrochloric acid and sodium hydroxide. The acid and base values were determined by Boehm's titration technique and $N_2$/77 K adsorption isotherm characteristics, the specific surface area and total pore volume were studied by BET. The PCL microcapsules containing SiO$_2$ and fragrant oil were prepared by oil-in-water (o/w) emulsion solvent evaporation method. The shape and surface of PCL microcapsules were observed using image analyzer and scanning electron microscope (SEM). The fragrant oil release behavior of PCL microcapsules was characterized using UV/vis. spectra. The average diameters of PCL microcapsules were decreased from 35 to 21 $\mu$m with increasing stirring rate. It was found that in the case of acidic treatment the fragrant oil adsorption capacity and release rate were increased due to the increase of specific surface area and acid value. In the case of basic treatment, the fragrant oil adsorption capacity and release rate were decreased due to the decrease of sp ecific surface area and the increase of acid-base interactions between SiO$_2$-NaOH and fragrant oil with increasing base value of SiO$_2$.

The Release of Albumin from PLGA and PCL Wafers Containing Natural and Synthetic Additives for Protein Delivery (단백질 전달체로서 천연 및 합성재료의 첨가에 따른 PLGA와 PCL웨이퍼로부터 알부민의 방출거동)

  • Hyun Hoon;Lee Jae Ho;Seo Kwang Su;Kim Moon Suk;Rhee Jhon M.;Lee Hai Bang;Khang Gilson
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.468-474
    • /
    • 2005
  • PLGA and PCL copolymers initiated by carbitol as drug carriers were synthesized by ring-opening polymerization of L-lactide (LA), glycolide (GA), and $\varepsilon-caprolactone(\varepsilon-CL)$. Implantable wafers were simply fabricated by direct compression method after physical mixing of copolymers and bovine serum albumin-fluorescein isothiocyanate (BSA-FITC) as a model protein drug. The release amounts of BSA-FITC from wafers were determined by fluorescence intensity using the fluorescence spectrophotometer. Also, the release behavior of BSA-FITC on wafers was controlled by adding the additives such as collagen, small intestinal submucosa (SIS), poly(vinyl pyrrolidone) (PVP), and poly(thylene glycol) (PEG). The wafer prepared by PLGA and PCL exhibited slow release within $10\%$ for 30 days. But, those prepared by a variety of additives exhibited the controlled BSA release patterns with a dependence on the additive contents. furthermore, the wafers containing natural materials such as collagen and SIS showed more zero-order release profile than that with synthetic materials such as PVP and PEG. It was confirmed that the release of BSA from implantable wafers could be easily controlled by adding natural additives.

Effects of Various Parameters on Biodegradation of Degradable Polymers in Soil

  • Shin, Pyong-Kyun;Jung, Eun-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.6
    • /
    • pp.784-788
    • /
    • 1999
  • The effects of pH, moisture content, and the relative amount of a polymer sample on the biodegradation of degradable polymers in soil were studied using various polymer materials such as cellulose, poly-(butylene succinate-co-adipate) (SG) polycaprolactone (PCL), a blend of PCL and starch (PCL-starch), and a poly-lactic acid (PLA). As with other materials, the polymers degraded faster at a neutral pH than at either acidic or basic conditions. Moisture contents of 60 and 100% water holding capacity exhibited a similar biodegradability for various polymers, although the effects differed depending on the polymer. For synthetic polymers, biodegradation was faster at 60%, while the natural polymer (cellulose) degraded faster at 100%. Fungal hypae was observed at a 60% water holding capacity which may have affected the biodegradation of the polymers. A polymer amount of 0.25% to soil revealed the highest biodegradability among the ratios of 0.25, 0.5, and 1%. With a higher sample amount, the residual polymer could be recovered after the biodegradation test. It was confirmed that a test for general biodegradation condition can be applied to plastic biodegradation in soil.

  • PDF