• Title/Summary/Keyword: $O_3$ sensitivity

Search Result 694, Processing Time 0.03 seconds

Characteristics of a planar Bi-Sb multijunction thermal converter with Pt-heater (백금 히터가 내장된 평면형 Bi-Sb 다중접합 열전변환기의 특성)

  • Lee, H.C.;Kim, J.S.;Ham, S.H.;Lee, J.H.;Lee, J.H.;Park, S.I.;Kwon, S.W.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.154-162
    • /
    • 1998
  • A planar Bi-Sb multijunction thermal converter with high thermal sensitivity and small ac-dc transfer error has been fabricated by preparing the bifilar thin film Pt-heater and the hot junctions of thin film Bi-Sb thermopile on the $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-diaphragm, which functions as a thermal isolation layer, and the cold junctions on the dielectric membrane supported with the Si-substrate, which acts as a heat sink, and its ac-dc transfer characteristics were investigated with the fast reversed dc method. The respective thermal sensitivities of the converter with single bifilar heater were about 10.1 mV/mW and 14.8 mV/mW in the air and vacuum, and those of the converter with dual bifilar heater were about 5.1 mV/mW and 7.6 mV/mW, and about 5.3 mV/mW and 7.8 mV/mW in the air and vacuum for the inputs of inside and outside heaters, indicating that the thermal sensitivities in the vacuum, where there is rarely thermal loss caused by gas, are higher than those in the air. The ac-dc voltage and current transfer difference ranges of the converter with single bifilar heater were about ${\pm}1.80\;ppm$ and ${\pm}0.58\;ppm$, and those of the converter with dual bifilar heater were about ${\pm}0.63\;ppm$ and ${\pm}0.25\;ppm$, and about ${\pm}0.53\;ppm$ and ${\pm}0.27\;ppm$, respectively, for the inputs of inside and outside heaters, in the frequency range below 10 kHz and in the air.

  • PDF

The Nasal Airflow Pressure Monitoring and the Measurement of Airway Pressure Changes in Obstructive Sleep Apnea Syndrome and Upper Airway Resistance Syndrome (수면무호흡증과 상기도저항 증후군에서 Nasal Airflow의 압력측정 및 상기도 압력변화에 대한 연구)

  • Kim, Hoo-Won;Hong, Seung-Bong
    • Sleep Medicine and Psychophysiology
    • /
    • v.7 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Objectives: The sensitivity and accuracy of thermistor airflow signal has been debated. The purposes of this study were to compare apnea-hypopnea index(AHI) detected from a conventional thermistor signal and a nasal pressure transducer of airflow(NPT), to evaluate the value of NPT for the diagnosis of upper airway resistance syndrome(UARS), and to measure airway pressure fluctuations which produced respiratory arousals in UARS by naso-oro-esophageal manometer catheter. The subjects were 30 patients with obstructive sleep apnea syndrome [mild(540), 10), and 6 UARS patients. Airway resistance arousal in this study was defined as arousals which were not associated with apnea or hypopnea of thermistor signal, but showed significant decrease of nasal airflow pressure just before arousal and a prompt recovery of nasal airflow pressure after arousal. The airway pressure fluctuations were measured during 260 airway resistance arousals observed in 10 patients with OSAS, 2 with UARS. Results: Mean AHIs of patients with OSAS were 33.4 by thermistor and 48.4 by NPT. The AHIs of mild, moderate and severe OSAS groups were 10.2, 32.1, 65.4 respectively by thermistor and 23.1, 45.9, 76.4 by NPT. The mean AHI of patients with UARS was 3.2 by thermistor and 10.8 by NPT. The mean AHI of patients with nonspecific arousals was 2.7 by thermistor and 4.4 by NPT. The mean airway pressure changes during respiratory arousals of different groups were $8.7\;cmH_2O$ in mild OSAS, $11.4\;cmH_2O$ in moderate OSAS, $24.7\;cmH_2O$ in severe OSAS and $6.6\;cmH_2O$ in UARS. Conclusion: The nasal pressure transducer of airflow was more sensitive and accurate for assessing respiratory disturbances of patients with OSAS and was extremely helpful for the diagnosis of UARS without esophageal pressure monitoring. From the results, we would like to propose carefully the NPT diagnostic criteria for sleep disordered breathing as follows: NPT-AHI 5-15 $\rightarrow$ UARS, 15-35 $\rightarrow$ mild OSAS, 35-55 $\rightarrow$ moderate OSAS and >55 $\rightarrow$ severe OSAS.

  • PDF

Usefulness of Tuberculin Test in Adult Patients with Suspected Pulmonary Tuberculosis (폐결핵이 의심되는 성인 환자에서 투베르쿨린 검사의 유용성)

  • Kang, Eun Hae;Koh, Won-Jung;Kwon, O Jung;Kim, Kyung Chan;Lee, Byoung-Hoon;Hwang, Jung Hye;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Lee, Kyung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.3
    • /
    • pp.268-279
    • /
    • 2004
  • Background : The tuberculin skin test has been used to diagnose latent tuberculosis infection, but is not widely used to diagnose or exclude pulmonary tuberculosis. The objective of this study was to evaluate the diagnostic utility of the tuberculin test in diagnosing and excluding pulmonary tuberculosis, and differentiating pulmonary tuberculosis from nontuberculous mycobacteria (NTM) pulmonary disease, when a sputum acid-fast bacilli (AFB) smear was positive. Material and Methods : From October 2002 to August 2003, among all the inpatients of the Division of Pulmonary and Critical Care Medicine at Samsung Medical Center, 258 patients with clinical suspicion of pulmonary tuberculosis were enrolled and underwent a tuberculin test. Results : 156 males and 102 females were included, with a mean age of 57.5 years. The final diagnoses included lung cancer in 89 cases (34.5%), pulmonary tuberculosis in 59 cases (22.9%), bacterial pneumonia in 33 cases (12.8%) and NTM pulmonary disease in 24 cases (9.3%). The positive tuberculin test rate was higher in the tuberculosis than non-tuberculosis group; 81.4 (48/59) vs. 42.4% (81/199). (p<0.001). In 208 patients with a negative sputum AFB smear, the result of the tuberculin test was positive in 69.4% (25/36) of the tuberculosis group and in 44.8% (77/172) of the non-tuberculosis group (p=0.007), so a positive result of the tuberculin test could predict pulmonary tuberculosis with 69.4% sensitivity, 55.2% specificity, a 24.5% positive predictive value and a 89.6% negative predictive value. In 50 patients with a positive sputum AFB smear, the positive rates of the tuberculin test were 83.9% (26/31) in tuberculosis group and 21.1% (4/19) in NTM pulmonary disease group (p<0.001), so a positive result of the tuberculin skin test could predict pulmonary tuberculosis with 83.9% sensitivity, 78.9% specificity, a 86.7% positive predictive value and a 75.0% negative predictive value. Conclusion : The tuberculin test could be useful in excluding pulmonary tuberculosis when the sputum AFB smear is negative, and to differentiate pulmonary tuberculosis from NTM pulmonary disease when the sputum AFB smear is positive.

The Correlation of Sensory Processing Type, Self-Esteem and Academic Ability in the College Students (대학생의 감각처리유형과 자존감, 학습능력의 상관관계 연구)

  • Park, Cho-Hee;Kim, Kyeong-Hee;Back, Jung-Eun;Kim, Jin-Yeon;O, Ka-Hee;Min, Ye-Ji;Im, Ga-Young;Cheon, Seul-Gi;Hong, Eun-Kyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.10 no.2
    • /
    • pp.33-39
    • /
    • 2012
  • Objective : The purpose of this study was identify the correlation of sensory processing type, academic ability and self-esteem in the college students. Methods : Duration of research was Act. 3rd, 2010 ~ Apr. 1st, 2011 and participants were 84 college students in Kyeong Nam. Method for study was the questionnaires investigation that included in AASP, self-esteem scale and grade. Data were statistically analyzed using the Statistical Package for the Social Sciences (SPSS) version 15 (SPSS Inc., Chicago, IL, USA). The correlation of various elements and core principles were analyzed using Pearson correlation. Results : Sensory avoiding (r=-.25), sensory sensitivity (r=-.22), sensory low registration (r=-.31) of sensory processing were correlation with self-esteem. sensory seeking (r=.22) of sensory processing correlation was correlation with academic ability. Conclusion : The results of this study emphasized that sensory processing ability is correlation with self-esteem and academic ability in the child as well as adult.

  • PDF

Seasonal Occurrence and Age Structure of Paromius exiguus (Distant) (Heteroptera: Lygaeidae) on Major Host Plants (흑다리긴노린재[Paromius exiguus (Distant)](Heteroptera: Lygaeidae)의 발생소장과 주요 기주에서 시기별 연령분포)

  • Park, Chang-Gyu;Park, Hong-Hyun;Uhm, Ki-Baik;Lee, Joon-Ho
    • Korean journal of applied entomology
    • /
    • v.48 no.1
    • /
    • pp.21-27
    • /
    • 2009
  • Paromius exiguus (Distant) has caused serious damage by pecky grains around Gimpo paddy fields in 2001. We conducted field and laboratory studies to determine the seasonal occurrence and age distribution of P. exiguus on the three major host plants. The overwintering P. exiguus was found mainly on the basal part of gramineae weeds in various localities. After overwintering, in mid-May, the adults aggregated on the grain parts of Imperata cylindrica, laid their eggs and nymphs developed into adults on the same host plants. By the time, the Calamagrostis epigeios colony had newly occupied I. cylindrica areas, the nymphs and adults of first generation had already moved to the second host. The second generation of P. exiguus, after having completed its life cycle on C. epigeios, the newly emerged adults migrated to the rice plants and other gramineae weeds in early August. Afterwards, they complete its third generation cycle where they can move to the overwintering site again. P. exiguus has the five nymphal stages and each nymphal stage could be determined by head or prothoracic width. On the I. cylindrica and O. sativa hosts, the age distribution of P. exiguus showed a simple structure as each stage ratio increased stepwise with time. But in case of C. epigeios, as the newly emerged adults and immature nymphs continuously migrate after a month from the I. cylindrica, the age structure became remarkably complex. The peak nymphal density was observed when the ratio of third and forth instar was the highest in the population. The finding about the specific age structure on each generation of the insect would be very useful in control decision making on the major host plants. It is also important to consider the host's specificity to pesticide sensitivity in relation to various nymphal stages.

Comparison of the Repetitive Nerve Stimulation Test(RNST) Findings Between in Upper and Lower Extremity Muscles in Myasthenia Gravis (중증근무력증 진단시 상지와 하지근육들에서의 반복신경자극검사 양성률의 비교)

  • Jung, Yun Seuk;Lee, Jun;Lee, Se Jin;Hah, Jung Sang;Kim, Wook Nyeon
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.129-136
    • /
    • 2000
  • Background and Purpose: This study was undertaken to compare the sensitivity of the Repetitive Nerve Stimulation Test (RNST) between the upper and lower extremity muscles in myasthenia gravis(MG) patients. Material and Methods: The study population consisted of 20 normal persons(control group) and 10 MG patients(MG group). Using Stalberg's method. RNST was systemically performed in orbicularis oculi muscle. upper extremity muscles(flexor carpi ulnaris. abductor digiti quinti), and lower extremity muscles(tibialis anterior. extensor digitorum brevis. vastus medialis). Results: There were statistical differences of decremental response($mean{\pm}SD$) in orbicularis oculi and upper extremity muscles between the control and MG groups(p<0.05 or p<0.01). However, there was no statistical difference of decremental response($mean{\pm}SD$) to RNST in lower extremity muscles between the control and MG groups. There were highersensitivity in orbicularis oculi and upper extremity muscles than lower extremity muscles. Although positive reponse were detected in the lower extremity muscles, the positive response rates of lower extremity muscles were lower than o.oculi and upper extremity muscles. Conclusions: When the response rates of RNST in facial and upper extremity muscles are normal, may not be required RNST in lower extremity muscles.

  • PDF

Studies on the Antibiotic Sensitivity of Escherichia coli Isolated from a Doctorless Area and Seoul National University Hospital (일부(一部) 무의촌지역(無醫村地域)과 병원(病院)에서 분리(分離)한 E.coli의 항생제(抗生劑) 감수성(感受性)에 대(對)하여)

  • Kim, Ik-Sang;Shin, Hee-Sup;Rhee, Kwang-Ho;Cha, Chang-Yong;Chang, Woo-Hyun
    • The Journal of the Korean Society for Microbiology
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 1977
  • 40 strains of E. coli isolated from residents of a doctorless area in Korea in 1976 and 40 strains of E. coli isolated from patients of Seoul National University Hospital from 1975 to 1976 were examined for susceptibilities to 14 antimicrobial agents by the agar dilution method. The susceptibilities of the two groups to each antimicrobial agent were compared and correlations in the antimicrobial susceptibility of the 80 strains of E. coli among the 14 antimicrobial agents were also analyzed. The results were obtained as follow: 1. With Tetracycline, Oxytetracycline, Doxycycline and Ampicillin, the mean MIC's of E. coli isolated from patients of Seoul National University Hospital were 8.6 to 14 times higher than. those of E. coli isolated from residents of a doctorless area. 2. With Streptomycin, Minocycline and Carbenicillin, the mean MIC's o{ E. coli isolated from patients of Seoul National University Hospital were 4.1 to 5.6 times higher than those of E. coil isolated from residents of a doctorless area. 3. With Kanamycin, Penicillin and Cotrimoxazole, the mean MIC's of E. coli isolated from patients of Seoul National University Hospital were 2.6 to 3.7 times higher than those of E. coli isolated from residents of a doctorless area. 4. There were no significant differences in susceptibility to Erythromycin respectively between E. coli isolated from patients of Seoul National University coli isolated from residents of a doctorless area. 5. E. coli isolated from patients of Seoul National University Hospital were resistant to Erythromycin(100%), Streptomycin(75%), Tetracycline(72.5%), Oxytetracycline(72.5%), Doxycycline(72.5%), Minocycline(67.5%), Penicillin(82.5%), Ampicillin(60%) and Carbenicillin(65%) respectively and were sensitive to Gentamicin(97.5%), Cephalexin(92.5%) and Kanamycin(72.5%) respectively. 6. E. coli isolated from residents of a doctorless, area were resistant to Erythromycin(100%), Streptomycin(40%) and Penicillin(50%) respectively and were sensitive to Gentamicin(100%), Kanamycin(92.5%), Tetracycline(87.5%), Oxytetracycline(87.5%), Doxycycline(87.5%), Minocycline(87.5%), Ampicillin(95%), Carbenicillin(92.5%) and Cephalexin(97.5%) respectively. 7. There were high correlations among the suscebtibilities of the 80 strains of E. coli to Tetracycline analogues(Tetracycline, Oxytetracycline, Doxycycline and Minocycline) and among susceptibilities of the 80 strains of E. coli to Penicillin analogues(Penicillin, Ampicillin and Carbenicillin). 8. There were relatively high correlations between the susceptibilities of the 80 strains of E. coli to Penicillin analogues and those to Tetracycline analogues, between the susceptibilities to Penicillin analogues and those to Streptomycin and between the susceptibilities to Tetracycline analogues and those to Streptomycin.

  • PDF

Pan-serotype reverse transcription loop-mediated isothermal amplification (RT-LAMP) for the rapid detection of foot-and-mouth disease virus (구제역바이러스 신속진단을 위한 pan-serotype reverse transcription loop-mediated isothermal amplification (RT-LAMP) 진단법)

  • Lim, Da-Rae;Park, Yu-Ri;Park, Sun-Young;Kim, Hye-Ryung;Park, Min-Ji;Ku, Bok-Kyung;Nah, Jin-Ju;Ryoo, So-Yoon;Wee, Sung-Hwan;Jeon, Hyo-Sung;Kim, Ji-Jeong;Jeon, Bo-Young;Lee, Hyeong-Woo;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.1
    • /
    • pp.29-39
    • /
    • 2018
  • In this study, we developed a sensitive and specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid visual detection of foot-and-mouth disease virus (FMDV) circulated in Korea. The RT-LAMP was completed in 40 min at $62^{\circ}C$ and the results of the assay were directly detected by naked eye without any detection process. The assay specifically amplified all 7 serotypes of FMDV RNAs but not amplified other viral and cellular nucleic acids. The sensitivity of the RT-LAMP was $10^2$, $10^3$ and $10^3TCID_{50}/mL$ for serotype O, A and Asia 1 FMDV, respectively, which was comparable to conventional reverse transcription polymerase chain reaction (RT-PCR) and relatively lower than that of real time quantitative RT-PCR (qRT-PCR). Clinical evaluation of the RT-LAMP using different serotypes of Korean and foreign FMDV strains showed a 100% (35/35) agreement with the results of the RT-PCR and qRT-PCR. These results indicated that RT-LAMP assay developed in this study could be a valuable diagnostic method for FMDV monitoring and surveillance.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Investigation of Microbial Safety and Correlations Between the Level of Sanitary Indicator Bacteria and the Detection Ratio of Pathogens in Agricultural Water (농업용수의 미생물학적 안전성 조사 및 위생지표세균 농도와 병원성미생물 검출률과의 상관관계 분석)

  • Hwang, Injun;Lee, Tae Kwon;Park, Daesoo;Kim, Eunsun;Choi, Song-Yi;Hyun, Jeong-Eun;Rajalingam, Nagendran;Kim, Se-Ri;Cho, Min
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.248-259
    • /
    • 2021
  • BACKGROUND: Contaminated water was a major source of food-borne pathogens in various recent fresh produce-related outbreaks. This study was conducted to investigate the microbial contamination level and correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water by logistic regression analysis. METHODS AND RESULTS: Agricultural water was collected from 457 sites including surface water (n=300 sites) and groundwater (n=157 sites) in South Korea from 2018 to 2020. Sanitary indicator bacteria (total coliform, fecal coliform, and Escherichia coli) and food-borne pathogens (pathogenic E. coli, E. coli O157:H7, Salmonella spp., and Listeria monocytogenes) were analyzed. In surface water, the coliform, fecal coliform, and E. coli were 3.27±0.89 log CFU/100 mL, 1.90±1.19 log CFU/100 mL, and 1.39±1.26 log CFU/100 mL, respectively. For groundwater, three kinds of sanitary indicators ranged in the level from 0.09 - 0.57 log CFU/100 mL. Pathogenic E. coli, Salmonella and Listeria monocytogenes were detected from 3%-site, 1.5%- site, and 0.6%-site water samples, respectively. According to the results of correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens by logistic regression analysis, the probability of pathogen detection increased individually by 1.45 and 1.34 times as each total coliform and E. coli concentration increased by 1 log CFU/100mL. The accuracy of the model was 70.4%, and sensitivity and specificity were 81.5% and 51.7%, respectively. CONCLUSION(S): The results indicate the need to manage the microbial risk of agricultural water to enhance the safety of fresh produce. In addition, logistic regression analysis is useful to analyze the correlation between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water.