• 제목/요약/키워드: $O_3$ sensitivity

검색결과 696건 처리시간 0.028초

외부변조 방식의 광송신기 제작 2.5Gbit/s 신호의 150km 광섬유 전송 (Fabrication of an externally modulated optical transmitter and transmission of 2.5Gbit/s signal over a 150 km long nondispersion-shifted fiber))

  • 한정희;윤태열;이상수;이창희
    • 전자공학회논문지A
    • /
    • 제32A권11호
    • /
    • pp.86-93
    • /
    • 1995
  • An optical transmitter was designed and implemented using a commercially available LiNbO$_{3}$ Mach-Zehnder modulator and the power amplifiers. We have adopted a new method to stabilize the bias voltage of the modulator using the second order harmonic component of the dithering signal. This technique has been applied successfully to the 2.5 Gbit/s external modulator for more than 6 hours without bit error rate degradaton. We demonstrated a repeaterless transmission of a 2.5 Gbit/s signal over 150 km nondispersion-shifted fiber using the transmitter. The receiver sensitivity was -34.5 dBm at 10$_{-10}$ bit error rate. No appreciable BER degradation due to fiber dispersion were observed after transmission.

  • PDF

양전자 방출 단층기

  • 나종범;조장희;노용만
    • 전기의세계
    • /
    • 제38권8호
    • /
    • pp.26-31
    • /
    • 1989
  • PET는 다른 nuclear imaging system(SPECT등)과는 달리 기계적 collimator가 필요없이 전자적 collimation을 할 수 있고 이런 collimation역할로 인하여 SPECT보다 감도(sensitivity)가 좋고 또한 전체 영상영역에 걸쳐 해상도와 감도가 균일하며 감쇄상수의 보정이 쉽다. 기존 X선 CT나 NMR-CT에 비해 해상도와 신호대 잡음비가 떨어짐에도 불구하고 PET 시스템 독특한 장점은 영상 자체가 단순한 영상을 재현하는 것이 아니라 인체내의 생태학적 또는 생리학적인 변화에 대한 정량적 분석이 가능하다는데 있다. 즉, $^{11}$ C, $^{13}$N, $^{15}$ O, $^{18}$ F와 같은 물질은 인체내에 생리적현상과 매우 밀접한 관계를 가지고 있어 이들 물질의 분포나 변화를 제공하는 것은 다른 의료 영상기기와 뚜렷이 구별되는 점이라 할 수 있다. 따라서 앞으로 분해 능력이 2-3mm의 PET시스템의 개발은 임상은 물론 의료연구용으로 매우 유용할 것이며 종래의 NMR과 X선 CT 와는 다른 보완적인 정보를 제공하는 영상시스템으로써 의료산업계의 발전에 크게 기여를 할 것이라고 본다.

  • PDF

ICP-RIE를 이용한 저압용 실리콘 압력센서 제작 (Fabrication of a silicon pressure sensor for measuring low pressure using ICP-RIE)

  • 이영태
    • 센서학회지
    • /
    • 제16권2호
    • /
    • pp.126-131
    • /
    • 2007
  • In this paper, we fabricated piezoresistive pressure sensor with dry etching technology which used ICP-RIE (inductively coupled plasma reactive ion etching) and etching delay technology which used SOI (silicon-on-insulator). Structure of the fabricated pressure sensor shows a square diaphragm connected to a frame which was vertically fabricated by dry etching process and a single-element four-terminal gauge arranged at diaphragm edge. Sensitivity of the fabricated sensor was about 3.5 mV/V kPa at 1 kPa full-scale. Measurable resolution of the sensor was not exceeding 20 Pa. The nonlinearity of the fabricated pressure sensor was less than 0.5 %F.S.O. at 1 kPa full-scale.

Te를 이용한 상온 동작형 NO2 센서 제작 및 감응 특성 (Room temperature operating nitrogen dioxide sensor based tellurium thin films)

  • 신한재;송갑득;주병수;손명호;이덕동
    • 센서학회지
    • /
    • 제16권2호
    • /
    • pp.91-96
    • /
    • 2007
  • The characteristic of tellurium thin films was studied for detecting nitrogen dioxide gas at room temperature. The film was deposited on $Al_{2}O_{3}$ substrate by using thermal evaporator. The subsequent process was heat treatment by several conditions. (temperature, flowed gases) Surface and grain boundary was investigated using SEM. The results showed that resistance of the tellurium film decreases reversibly in the presence of nitrogen dioxide. The sensitivity of this device depends on the gas concentration and detect lower concentrations less than 10 ppm.

Back-Face Strain Compliance Calibration for the Four-Point Bend Specimen

  • Huh, Yong-Hak;Song, Ji-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제14권3호
    • /
    • pp.314-319
    • /
    • 2000
  • Back-face strain compliance (BFS compliance) for the four-point bend specimen has been calibrated for various crack length ratios. Finite element technique was employed to simulate four-point loading and calculate back-face strain of the bend specimen. The numerically determined strain variation along the back face indicates that the sensitivity to gage placement increases with crack length and back-face strain at the gage length less than O.2W, where W is the width of the bend specimen, can be measured within 5% deviation of the maximum BFS. Non-dimensional back-face strain compliance, -E'BCW, was calibrated with FE analysis and experiment. The experimentally determined compliance indicates good agreement with the numerical compliance and can be expressed as a function of crack length ratio.

  • PDF

오존농도 시뮬레이션과 배출량 변화에 따른 민감도 분석 (Ozone Simulation and Sensitive Test under Varying Emission Condition)

  • 한진석;김병곤;김신도
    • 환경영향평가
    • /
    • 제5권1호
    • /
    • pp.69-77
    • /
    • 1996
  • The variations of ozone concentration and the sensitivity test for VOC emission intensities was investigated by means of a PBM(Photochemical Box Model). Compared to monitoring data, the typical variations of $NO_2$, CO, $O_3$ for days were successfully reproduced. Model results revealed that maximum ozone concentration got increased with the increase of VOC emission, that is, VOC played the important role in producing the photochemical smog.

  • PDF

Serum Deprivation Enhances Apoptotic Cell Death by Increasing Mitochondrial Enzyme Activity

  • Moon, Eun-Yi
    • Biomolecules & Therapeutics
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2008
  • Mitochondria are important sensor of apoptosis. $H_2O_2-induced$ cell death rate was enhanced by serum deprivation. In this study, we investigated whether serum deprivation using 0.5 or 3 % FBS induces apoptotic cell death through mitochondrial enzyme activation as compared to 10 % FBS. Apoptotic cell death was observed by chromosome condensation and the increase of sub-G0/G1 population. Serum deprivation reduced cell growth rate, which was confirmed by the decrease of S-phase population in cell cycle. Serum deprivation significantly increased caspase-9 activity and cytochrome c release from mitochondria into cytosol. Serum deprivation-induced mitochondrial changes were also indicated by the increase of ROS production and the activation of mitochondrial enzyme, succinate dehydrogenase. Mitochondrial enzyme activity increased by serum deprivation was reduced by the treatment with rotenone, mitochondrial electron transport inhibitor. In conclusion, serum deprivation induced mitochondrial apoptotic cell death through the elevation of mitochondrial changes such as ROS production, cytochrome c release and caspase-9 activation. It suggests that drug sensitivity could be enhanced by the increase of mitochondrial enzyme activity in serum-deprived condition.

Changes in Availability of Toxic Trace Elements (TTEs) and Its Effects on Soil Enzyme Activities with Amendment Addition

  • Lee, Sang-Hwan;Park, Misun;Kim, Min-Suk
    • Ecology and Resilient Infrastructure
    • /
    • 제7권2호
    • /
    • pp.134-144
    • /
    • 2020
  • In-situ stabilization is a remediation method using amendments to reduce contaminant availability in contaminated soil. We tested the effects of two amendments (furnace slag and red mud) on the availability of toxic trace elements (TTEs) and soil enzyme activities (dehydrogenase, phosphatase, and urease). The application of amendments significantly decreased the availability of TTEs in soil (p < 0.05). The decreased availability of TTE content in soils was accompanied by increased soil enzyme activities. We found significant negative relationships between the TTE content assessed using Ca(NO3)2-, TCLP, and PBET extraction methods and soil enzyme activities (p < 0.01). Soil enzyme activities responded sensitively to changes in the soil environment (pH, EC, and availability of TTEs). It could be concluded that soil enzyme activities could be used as bioindicators or ecological indicators for soil quality and health in environmental soil monitoring owing to their high sensitivity to changes in soil.

기능성 원자간력 현미경 캔틸레버를 이용한 표면 전위 측정 (Surface potential mapping using a functional AFEM cantilever)

  • 서문석;이철승;이경일;신진국
    • 정보저장시스템학회:학술대회논문집
    • /
    • 정보저장시스템학회 2005년도 추계학술대회 논문집
    • /
    • pp.53-55
    • /
    • 2005
  • The surface potential variations are measured, according to the enhanced measuring speed and voltage sensitivity, using an active device, such as a field effect transistor $(FET)^{1-3}$. In this study, the surface potential was mapped in the patterned $SiO_2$ medium at room temperature. An improved FET-tip cantilever, which has a source, a drain, and an n- channel, was used in this study. The potential images were analyzed both in the contact mode and the non-contact mode, using only a pre-amplifier system instead of a lock-in the amplifier.

  • PDF

치조제확대골절단술(RIDGE EXPANSION OSTEOTOMY)을 이용한 임프란트의 매식 (PLACEMENT OF IMPLANTS BY THE USE OF RIDGE EXPANSION OSTEOTOMY PROCEDURE)

  • 오희균
    • 대한치과의사협회지
    • /
    • 제34권3호통권322호
    • /
    • pp.215-222
    • /
    • 1996
  • Ridge expansion osteotomy(REO) procedure is used to widen the narrow ridge in locations that are too thin to permit the use of standard implant drills. The objective of this technique is to maintain, if possible, all of the existing maxillary bone by pushing the bone aside with minimal trauma. The author has used tis procedure on five patients who had narrow ridge in their soft maxillary bone. Fifteen implants were placed in sites needing ridge expansion using REO. The satisfactory results were obtained. The REO procedure is thought to be a safer and more conservative method of widening a narrow ridge. And this procedure is heatless, offers excellent tactile sensitivity, control, visibility, and takes advantage of available bone.

  • PDF