• 제목/요약/키워드: $Na^+$ pump

검색결과 178건 처리시간 0.029초

원자로 냉각재 펌프 고장예측진단을 위한 데이터 분석 플랫폼 구축 (Data Analysis Platform Construct of Fault Prediction and Diagnosis of RCP(Reactor Coolant Pump))

  • 김주식;조성한;정래혁;조은주;나영균;유기현
    • 한국IT서비스학회지
    • /
    • 제20권3호
    • /
    • pp.1-12
    • /
    • 2021
  • Reactor Coolant Pump (RCP) is core part of nuclear power plant to provide the forced circulation of reactor coolant for the removal of core heat. Properly monitoring vibration of RCP is a key activity of a successful predictive maintenance and can lead to a decrease in failure, optimization of machine performance, and a reduction of repair and maintenance costs. Here, we developed real-time RCP Vibration Analysis System (VAS) that web based platform using NoSQL DB (Mongo DB) to handle vibration data of RCP. In this paper, we explain how to implement digital signal process of vibration data from time domain to frequency domain using Fast Fourier transform and how to design NoSQL DB structure, how to implement web service using Java spring framework, JavaScript, High-Chart. We have implement various plot according to standard of the American Society of Mechanical Engineers (ASME) and it can show on web browser based on HTML 5. This data analysis platform shows a upgraded method to real-time analyze vibration data and easily uses without specialist. Furthermore to get better precision we have plan apply to additional machine learning technology.

배관의 부식 상태 진단에 사용되는 ER 부식센서의 가속부식환경에서의 신뢰성 평가 (Reliability Evaluation of ER Type Corrosion Sensor for Monitoring Corrosion of Piping System Under Accelerated Corrosion Environment)

  • 황현규;신동호;김헌희;이정형
    • Corrosion Science and Technology
    • /
    • 제20권6호
    • /
    • pp.403-411
    • /
    • 2021
  • In this study, the reliability of a commercial ER-type corrosion sensor was evaluated under an accelerated corrosion environment to verify its suitability for application in monitoring of ship's seawater piping system. A closed-loop pump piping testbed was designed and constructed to compare the wall thickness reduction of the pipe and the response from the sensor. The sensor was attached inside the pipe near the outlet of the pump that was exposed to a 3.5% NaCl solution with or without copper accelerated acetic acid (CASS). The results demonstrated that the presence of CASS significantly increased the corrosivity of the solution as well as the thickness reduction of the pipe, as expected. On the other hand, the corrosion products formed by the solution with CASS were thicker compared with those without CASS. The sensor response to temperature variation was found to be a clear linear relationship for the solution without CASS but there was a non-linear relationship where CASS was present.

Change of Blood Magnesium Level in Diabetes Patients Undergoing Off-pump Coronary Artery Bypass Grafting

  • Seo, Si-Young;Moon, Seong-Min;Hyun, Kyung-Yae;Kim, Chong-Rak;Choi, Seok-Cheol
    • 대한의생명과학회지
    • /
    • 제15권3호
    • /
    • pp.207-215
    • /
    • 2009
  • We carried out this study to investigate differences of physiological variables between patients with (DM group) and without type II diabetes mellitus (Non-DM group) undergoing off-pump coronary artery bypass grafting (OPCABG). Postoperative $Mg^{++}$ and $Ca^{++}$ levels were lower, whereas $Na^+$ level was higher in DM group than those in Non-DM group. ICU (intensive care unit) stay time in DM group was longer than that of Non-DM group. Postoperative platelet counts tended to decrease, whereas C-reactive protein (CRP) and cardiac troponin-I (cTNI) levels tended to increase in DM group compared with Non-DM group. Postoperative albumin level was lower, while blood urea nitrogen (BUN) and creatinine levels were greater in DM group than those in Non-DM group. DM group had higher incidence of post-operative arrhythmias than Non-DM group. These results reveal that type II DM patients undergoing OPCAB may have higher incidences of postoperative hypomagnesemia, hypocalcemia and arrhythmias, and increases of CRP, cTNI, BUN, and creatinine levels than in Non-DM patients undergoing OPCAB. The perioperative check and control (supplement) of $Mg^{++}$ levels should be considered in cardiovascular surgery combined with DM.

  • PDF

누설특성을 고려한 GDI 엔진용 연료펌프의 고압생성 증진에 관한 연구 (A Study on the Pressure Increment of Fuel Pump for GDI Engines Considering Leakage Flows)

  • 나병철;김병수;최석우
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.785-791
    • /
    • 2000
  • GDI (Gasoline Direct Injection) engines are considered as one of the candidates for next generation engines of passenger cars, which reduce exhaust emissions and fuel consumption. In GOI engines, a high-pressure gasoline supply system is required to directly inject the fuel to combustion chambers. Because of low lubricity of gasoline fuel, the clearance between a plunger and a barrel in GDI fuel pumps is too wide to achieve smooth hydrodynamic lubrication. Thus, it is difficult to generate high-pressure condition in GDI fuel pump since large amount of leakage flow occurs between the plunger and the barrel In this study, an optimum plunger design is presented to minimize leakage in the aspect of flow control. This paper analyzes leakage flow characteristics in the clearance to improve pumping performance of GDI fuel pumps. Effects of groove in the plunger are studied according to variations of depth and width. Evaluations of pumping performance are determined by the amount of pressure drop in the leakage path assuming a constant leakage flows. Both of turbulence and incompressible models are introduced in CFD (Computational Fluid Dynamics) analysis. Design parameters have been introduced to minimize leakage in limited space, and a methodological study on geometrical optimization has been conducted. As results of CFD analysis in various geometrical cases, optimum groove depths have been found to generate maximum sealing effects on gasoline fuel between the plunger and the barrel. This procedure offers a methodological way of an enhancement of plunger design for high-pressure GDI fuel pumps.

진행파를 이용한 압전 마이크로 펌프의 설계와 해석 (Design and Analysis of Piezoelectric Micro-Pump Using Traveling-Wave)

  • 나영민;이현석;박종규
    • 대한기계학회논문집A
    • /
    • 제38권5호
    • /
    • pp.567-573
    • /
    • 2014
  • 최근에, 의학 분야의 MEMS 기술이 발전하면서 다양한 미세 유체 이송 시스템이 연구되고 있다. 본 논문에서는 기존의 펌프와는 다른, 두 개의 분리된 압전 판을 이용해 위장의 연동 운동을 모방한 마이크로 압전 펌프를 제안한다. 본 펌프는 진행파를 이용해 연동 운동을 일으켜 작동된다. 특히, 압전판에서 인가된 입력 전압에 의해 발생된 변위에 의해 동작된다. 이에 두 판 사이에서 진행파가 일어나며 유체는 진행파에 의해 생성된 압력차에 의해 이동된다. 압전 소자, 탄성체, 유체가 복합된 시스템을 이해하기 위해서 유한 요소 해석을 사용하였다. 챔버의 높이, 세라믹 개수 등의 설계 변수들을 변화시켜 유체의 유량을 확인하였다.

양성자펌프억제제, 스테로이드흡입제, 보툴리늄톡신 주사를 이용한 접촉성 육아종의 치료 결과 (Treatment Result of Proton Pump Inhibitor, Steroid Inhaler and Botulinum Tonxin Injection for Contact Granuloma)

  • 박형민;오나래;백민관;김동영;우주현
    • 대한후두음성언어의학회지
    • /
    • 제28권1호
    • /
    • pp.32-37
    • /
    • 2017
  • Background and Objectives : This study evaluated the efficacy of combination therapy of proton pump inhibitor (PPI) and steroid inhaler (SI), with or without botulinum toxin injection (BTX) for contact granuloma. Subjects and Methods : Fourteen contact granuloma patients were enrolled in this study. Combination therapy of PPI and SI were used for the first line treatment. When combination therapy was not effective, BTX was performed as the second method. Treatment results were recorded as responsible or non-responsible. Farwell grade, size, history of voice abuse, gender, and reflux finding score (RFS) were compared between responsible group and non-responsible group. Results : Initial response rate was 28.6% after treatment of PPI and SI. BTX was performed on three un-responsible patients. After BTX injection, three patients had complete remission of granuloma. Final response rate was 50.0%. Un-responsible group had significantly higher RFS than responsible group. Conclusion : The efficacy of PPI and SI was limited for contact granuloma in this study. Botulium toxin injection was recommended in early phase when PPI and SI did not effective for contact granuloma. Prospective studies evaluating the effects of PPI and SI are warranted.

  • PDF

국제 호환형 지열히트펌프 시스템 경제성 평가 연구 (International Harmonized Economic Assessment Study of a Ground Source Heat Pump System)

  • 나선익;강은철;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2014
  • This study intends to analyse the economical aspect of a GSHP(Ground Source Heat Pump) system compared to the conventional system which is consisted with a boiler and a chiller. This study has simulated four systems in Incheon. It developed and analyzed for applications in a residential and an office building which was based on the hourly EPI(Energy Performance Index, $kWh/m^2yr$). Case 1 is utilizing a boiler and a chiller to meet heating and cooling demand of a house. Case 2 is utilizing the same conventional set up as Case 1 of a office. Case 3 is summation of Case 1(house) and 2(office) systems and loads. And Case 4 is utilizing a GSHP to meet the combined loads of the house and office. The method of the economic assessment has been based on IEA ECBCS Annex 54 Subtask-C SPB(Simple Payback) method. The SPB calculated the economic balanced year of the alternative system over the reference system. The SPB of the alternative systems (GSHP) with 10%, 30% and 50% initial incentive has been calculated as 9.38, 6.72 and 4.06 year respectively while the SPB without initial incentive of systems was 10.71 year.

열원조건 분석 통한 흡수식 히트펌프 적용 열에너지 네트워크의 에너지 절감 예측 (A Study on the Energy Reduction of a Heating Network Through the Application of an Absorption Heat Pump)

  • 나선익;이영수;백영진;이길봉
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.239-248
    • /
    • 2017
  • At the $21^{st}$ Conference of the Parties (COP) of the United Nations Climate change Conference, representatives of the 195 member countries reached an agreement requiring all participating countries, including Korea, to establish proactive measures to fight climate change. Under this vision, energy network technologies are deemed as a key site of research towards meeting this goal. Herein, the headquarters of the Korea Institute of Energy Research (KIER) is a worthy site for carrying out energy network technology research insofar as it contains various heat sources. To prepare for this research, a study was conducted analyzing the heat sources at KIER based on measured data. The study also consisted of developeding simulation models to predict the amount of energy savings that could be derived by replacing an absorption chiller/heater with an absorption heat pump during winter seasons. In our simulation results, we observed a primary energy saving ratio of 65~72% based on the water temperature from the heat source of a coal power plant.

Effectiveness of continuous hypertonic saline infusion with an automated infusion pump for decompressive neuroplasty: a randomized clinical trial

  • Lee, Ho-Jin;Lee, Jaewoo;Park, Yeon wook;Gil, Ho Young;Choi, Eunjoo;Nahm, Francis Sahngun;Lee, Pyung Bok
    • The Korean Journal of Pain
    • /
    • 제32권3호
    • /
    • pp.196-205
    • /
    • 2019
  • Background: Hypertonic saline (HS) injections for decompressive neuroplasty (DN) can cause pain. We assessed whether a continuous infusion of HS through an infusion pump would reduce injection-related pain compared with repeated bolus administrations. Methods: Fifty patients scheduled for DN were randomized to either the bolus injection or the continuous infusion group. After appropriately placing the epidural catheter, 4 mL of 5% NaCl was injected as four boluses of 1 mL each at 15-minute intervals or infused over 1 hour using an infusion pump. The severity of pain induced by HS injection, as measured by the 11-point numerical rating scale (NRS), was the primary outcome. The severity of low back or lower extremity pain, as measured by the 11-point NRS and Oswestry Disability Index (ODI), 3 months following the procedure, was the secondary outcome. Results: Data from 21 patients in the bolus group and 23 in the continuous infusion group were analyzed. No statistically significant difference in injection-related pain was identified between the two groups during the initial HS administration (P = 0.846). However, there was a statistically significant reduction in injection-related pain in the continuous infusion group compared to the bolus injection group from the second assessment onwards (P = 0.001, < 0.001, and < 0.001, respectively). No significant between-group differences in the NRS and ODI scores 3 months post-procedure were noted (P = 0.614 and 0.949, respectively). Conclusions: Our study suggests that administering HS through a continuous infusion is a useful modality for reducing HS injection-related pain during DN.

Isolation and Characterization of Endosome Subpopulation in Chinese Hamster Ovarian Cells

  • Suh, Duk-Joon;Park, Mi-Yeon;Jung, Dong-Keun;Bae, Hae-Rahn
    • The Korean Journal of Physiology
    • /
    • 제30권2호
    • /
    • pp.197-208
    • /
    • 1996
  • Endosomes lower their internal pH by an ATP-driven proton pump, which is critical to dissociation of many receptor-ligand complexes, the first step in the intracellular sorting of internalized receptors and ligands. Endosomes are known to exhibit n great range of pH values that can vary between 5.0 and 7.0 within a single cell although the factors that regulate endosomal pH remain uncertain. To evaluate the morphological and topological differences of endosomes in the different stages, confocal microscopy was used. The early endosomes labeled with fluorescein isothiocyanate-dextran for 10 min at $37^{\circ}C$ were identifiable at the peripheral and tubule-vesicular endosome compartment. In contrast, the late endosomes formed by 10 min pulse and 20 min trace were located deeper in the cytoplasm and showed more vesicular features than early endosomes. For the purpose of determining whether ATP-dependent acidification was heterogeneous and whether the differences in acidification were attributed to differences in the activity of $Na^{+}-K^{+}$-ATPase and/or $Cl^{-}$ channel, endocytic compartments were fractionated into subpopulation using percoll gradient and measured ATP-dependent acidification. While all fractions exhibited ATP-dependent acidification activity, both the initial rate of acidification and extent of proton translocation were lower in early endosomes and gradually increased in late endosomes. Phosphorylation by PKA and ATP enhanced ATP-dependent acidification in both early and late endosomes, hut there was no difference in the degree of enhancement by phosphorylation between two subpopulations. When ATP-dependent acidification was determined in the presence or absence of vanadate ($Na_{3}VO_{4}$) or ouabain, only early endosomes exhibited the vanadate or ouabain dependent stimulation of acidification activity, suggesting the inhibition of $Na^{+}-K^{+}$-ATPase. Therefore, it seems probable that the inhibition of early endosome acidification by $Na^{+}-K^{+}$-ATPase observed in vitro at least in part plays a physiological role in controlling the acidification of early endosomes in vivo.

  • PDF