• Title/Summary/Keyword: $N_f$ 선

Search Result 136, Processing Time 0.031 seconds

Separation Permeation Characteristics of N2-O2 Gas in Air at Cell Membrane Model of Skin which Irradiated by High Energy Electron (고에너지 전자선을 조사한 피부의 세포막모델에서 공기 중의 O2-N2 혼합기체의 분리투과 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.261-270
    • /
    • 2019
  • The separation permeation characteristics of $N_2-O_2$ gas in air at cell membrane model of skin which irradiated by high energy electron(linac 6 MeV) were investigated. The cell membrane model of skin used in this experiment was a sulfonated polydimethyl siloxane(PDMS) non-porous membrane. The pressure range of $N_2$ and $O_2$ gas were appeared from $1kg_f/cm^2$ to $6kg_f/cm^2$. In this experiment(temperature $36.5^{\circ}C$), the permeation change of $N_2$ and $O_2$ gas in non-porous membrane by non-irradiation were found to be $1.19{\times}10^{-4}-2.43{\times}10^{-4}$, $1.72{\times}10^{-4}-2.6{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. That of $N_2$ and $O_2$ gas in non-porous membrane by irradiation were found to be $0.19{\times}10^{-4}-0.56{\times}10^{-4}$, $0.41{\times}10^{-4}-0.76{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. The irradiated membrane was significantly decreased about 4-10 times than membrane which was not irradiated. And ideal separation factor of $N_2$ and $O_2$ gas by non-irradiation was found to be from 1.32 to 0.42 and that of $N_2$ and $O_2$ gas by irradiation was found to be from 0.237 to 0.125. The irradiated membrane was significantly decreased about 4-5 times than membrane which was not irradiated. When the operation change(cut) and pressure ratio(Pr) by non-irradiation were about 0, One was increased to the oxygen enrichment and the other was decreased to the oxygen enrichment. The irradiated membrane was significantly decreased about 4-19 times than membrane which was not irradiated. As the pressure of $N_2$ and $O_2$ gas was increased, the selectivity was decreased. As separation permeation characteristics of $N_2-O_2$ gas in cell membrane model of skin were abnormal, cell damages were appeared at cell.

The Crystal Structure of $C_{13}H_{15}N_3O_3$ ($C_{13}H_{15}N_3O_3$의 결정 구조)

  • Park, Hai-Yoon;Kim, Moon-Jib;Park, Ho-Jong
    • Korean Journal of Crystallography
    • /
    • v.15 no.1
    • /
    • pp.24-28
    • /
    • 2004
  • The structure of $C_{12}H_{15}N_3O_3$ has been determined by X-ray diffraction methods. The crystal system is monoclinic, space group $P2_1/c$, unit cell constants, a = 12.9955(9) ${\AA}$, b = 7.7137(5) ${\AA}$, c = 13.4699(11) ${\AA}$, ${\beta}$ = 107.86(1)$^{\circ}$, V = 1285.2(1) ${\AA}^3$, T = 296 K, Z = 4, $D_c$ = 1.350 $Mgm^{-3}$. The intensity data were collected on an Enraf-Nonius CAD-4 Diffractometer with graphite monochromated Mo $K{\alpha}$ radiation (${\lambda}$ = 1.71073 ${\AA}$). The molecular structure was solved by direct methods and refined by full-matrix least squares to a final R = 4.19% for 1644 unique observed $F_0\;>\;4{\sigma}(F_0)$ reflections 193 parameters.

The comparison of the fatigue crack initiation life in a notch (노치부의 피로균열발생 수명 비교)

  • Kim, S.H.;Bae, S.I.;Ham, K.C.;Song, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.217-222
    • /
    • 2001
  • For the life evaluating of notched members, it is the best way that performing the real fatigue test of structure containing notch. But this method required generally much times and costs to evaluate fatigue life. So, generally we use the modified S-N curve or several methods to predict fatigue life. In this study, crack initiation life was evaluated by fatigue testing the SAE keyhole specimen and smooth specimen made of Al 7075-T6 alloys using the constant load then obtained S-N curve of smooth specimen and P-N curve of SAE keyhole specimen. And, fatigue lives of keyhole specimen are predicted using some life prediction methods (Nominal range I method, Nominal range II method, FEM analysis) for investigating experimented results, and that were compared with experimental data. Predicted fatigue lives by FEM analysis were corresponded with experimental data between 1/3times and 3times on the whole, and predicted fatigue lives using modified S-N curve (Nominal range I method, Nominal range II method) were nonconservative compared with that of FEM analysis.

  • PDF

The Crystal Structure of N-(Diphenylmethylene) aminomethylphosphonate (N-(Diphenylmethylene)aminomethylphosphonate의 결정 구조)

  • 김문집;박호종;김대영
    • Korean Journal of Crystallography
    • /
    • v.13 no.2
    • /
    • pp.86-90
    • /
    • 2002
  • The structure of N-(Diphenylmethylene)aminomethylphosphonate has been determined by X-ray diffraction methods. The crystal system is triclinic, space group P(equation omitted), unit cell constants, a=8.967(2) (equation omitted), b=9.309(2) (equation omitted), c= 10.981(2) (equation omitted), α=101.42(2)°, β=92.22(2)°, γ=92.23(2)°, V=896.8(3) (equation omitted), T=296 K, Z=2, D/sub c/=1.227 Mgm/sup -3/. The intensity data were collected on an Enraf-Nonius CAD-4 Diffractometer with graphite monochromated MoKα radiation (λ=0.7107(equation omitted)). The molecular structure was solved by direct methods and refined by full-matrix least-squares to a final R=7.3% for 979 unique observed F/sub o/>4σ(F/sub o/) refections and 209 parameters.

Determining "n" Value of Rainfall Intensity-duration Formular Based on the Maximum 24 Hour Rainfall and the Daily Rainfall of a Designated Time (일강우량과 24시간 강우량에 의한 강우강도식의 n식 결정)

  • 안상진;박영일
    • Water for future
    • /
    • v.15 no.2
    • /
    • pp.23-32
    • /
    • 1982
  • This study is to clarify the relation between the maximum 24 hour rainfall and the daily rainfall of a designated time 10 A.M., using the 506 rainfall datum from 32 rain-guage stations on the Han river basin covering a period of 7 years and trying to estimate the ratio of two data in accordance with the amount of rainfall respectively. The Mononobe's formula, which is widely used in this country, has the value of 2/3 power in it. The "n" was considered instead of 2/3 and derivated for each guaging station. The results make it possible to establish the Ison-n value map, and show that the n value is affected mainly by the topographical conditions. The daily rainfall of a designated time can be modified by the results of this study and expressed as Y(%)=218.25/R$$. But in the case of exceeding 200mm/day, it is recommended to use the 110% for safety. On the problems of intensity-duration concerned with the planning of public works, the formula can be expressed as r$$=fRday/24.(24/t)$$, where "f" is Y(%) divided by 100. As this study was done with the datum within shor period, it is necessary to study more about the "n" and "f" value so as to get previse value in the future.o as to get previse value in the future.

  • PDF

Experimental Study on Tensile Fatigue Strength of the High Strength Bolts (고장력볼트의 인장피로강도에 관한 실험적 연구)

  • Han, Jong Wook;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.165-170
    • /
    • 2008
  • New high strength bolts are required due to the development of the high strength steel, the ultra-thick steel plates, and the long-span bridge, though high strength bolts with tensile strength of 1,000 MPa are mainly used in construction site of every country. The high strength bolts are often subjected to a repeated tension-type of loading in which the fatigue failure is a major mode of failure. However, the theoretical and experimental study for the fatigue failure of tension bolt has not been well established in Korea. In this study, we performed a tensile fatigue test of F8T, F10T and F13T, F13T-N high strength bolts under tension. We proposed three fatigue strength specifications by performing 95% survival probability analysis for F8T, F10T, F13T, and F13T-N bolt under the $2{\times}10^6$ cycles of repeated loading. And the fatigue strength for the advanced screw thread shape bolt developed in this study are compared with the previous KS screw thread shape bolt.

The Performance Analysis of DS/SSMA BPSK Correlation Receivers in Electric Power Line Channel (전력선 채널에서의 DS/SSMA BPSK 코릴레이션 수신기 성능에 관한 연구)

  • Kang, Byeong-Kwon;Cho, Chang-Gil;Cho, Kwan;Lee, Jae-Kyeong;Whang, Keum-Chan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.9
    • /
    • pp.972-981
    • /
    • 1992
  • In this paper, the performance of linear and hard-limiting correlation receivers for DS/SSMA BPSK power line communication system is analyzed. Strong impulsive noise of power line is modeled with Chan's noise model, and the performance of both receivers is analyzed in terms of parameters such as ratio of power spectrum density of impulsive noise to that background noise, ratio in impulsive noise width th that of data bit, and interarrival time of impulsive noise. And also multiple access capacity is evaluated with Gaussian approximation of multiple access interference. The results of this analysis reveal that the performance of linear correlation receiver is superior to that of hard-limiting correlation receiver when $N_1/N_b$ is small and is close to 1. But the BER and the multiple access capacity of hard-limiting correlation receiver becomes better in comparison with linear correlation receiver as $N_1/N_b$ increases.

  • PDF

A Study on the Prediction of Fatigue Life in 2024-T3 Aluminium using X-ray Half-Value Breadth (X선 반가폭을 이용한 Al 2024-T3 합금의 피로수명예측에 관한 연구)

  • 조석수;김순호;주원식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.145-152
    • /
    • 2000
  • X-ray diffraction method detects change of crystal lattice distance under material surface using diffraction angle 2$\theta$. This technique can be applied to the behavior on slip band and micro crack due to material degradation. The relation between half-value breadth and number of cycle has three stages which constitute rapid decrease in initial number of cycles, slight decrease in middle number of cycles and rapid decrease in final number of cycles. The ratio of half-value breadth takes a constant value on B/B$_{0}$-N diagram with loading condition except early part of fatigue life. The ratio of half-value breadth B/B$_{0}$ with respect to number of cycle to failure N$_{f}$ has linear behavior on B/B$_{0}$-log N$_{f}$ diagram. Therefore, in this paper the estimation of fatigue life by average gradient method has much less estimated mean error than the estimation of fatigue life by log B/B$_{0}$-log N/N$_{f}$ relation.elation.ation.

  • PDF

Jacket Matrix in Hyperbola (쌍곡선에서의 재킷 행렬)

  • Yang, Jae-Seung;Park, Ju-Yong;Lee, Moon-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.15-24
    • /
    • 2015
  • Jacket matrices which are defined to be $m{\times}m$ matrices $J^{\dagger}=[J_{ik}^{-1}]^T$ over a Galois field F with the property $JJ^{\dagger}=mI_m$, $J^{\dagger}$ is the transpose matrix of element-wise inverse of J, i.e., $J^{\dagger}=[J_{ik}^{-1}]^T$, were introduced by Lee in 1984 and are used for Digital Signal Processing and Coding theory. This paper presents some square matrices $A_2$ which can be eigenvalue decomposed by Jacket matrices. Specially, $A_2$ and its extension $A_3$ can be used for modifying the properties of hyperbola and hyperboloid, respectively. Specially, when the hyperbola has n times transformation, the final matrices $A_2^n$ can be easily calculated by employing the EVD[7] of matrices $A_2$. The ideas that we will develop here have applications in computer graphics and used in many important numerical algorithms.

Fatigue Life Evaluation of Spot Weldment Using DCPDM (직류전위차법을 이용한 점용접부의 피로수명 평가)

  • 유효선;이송인;권일현;안병국
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.58-64
    • /
    • 2001
  • The initiation and propagation lives of fatigue crack were studied for spot weldments composed of cold rolled steel plates(SPC$\times$SPC) and galvanized steel plates(GA$\times$GA) using DC potential drop method(DCPDM). Through the various test results, it was known that the fatigue crack initiation and propagation behaviors in all specimens could be definitely detected by DCPDM. The fatigue crack initiation life( $N_{i}$) detected by DCPDM in SPC$\times$SPC and GA$\times$GA spot weldments increased as the welding current and the nugget diameter( $N_{d}$) increased. The fatigue crack propagation life($\Delta$ $N_{f-i}$) declined as the difference of $N_{i}$ and the fatigue fracture life( $N_{f}$) also increased according to the decrease of fatigue load, $\Delta$P and the increase of nugget diameter. In the same spot weldments, the increase of nugget diameter came to increase fatigue crack propagation life owing to a decrease of stress concentration in front of nugget, especially the increasing extent for GA$\times$GA spot weldment was very high. In the welding current 6kA, $N_{f}$ for GA$\times$GA spot weldment decreased more than that of SPC$\times$SPC specimen due to zinc layer coated in steel plate and undersized nugget diameter. On the other hand, in 8kA and 10kA, the GA$\times$GA spot weldment showed higher $N_{f}$ in spite of lower $N_{i}$, than that of SPC$\times$SPC specimen except 3,000N fatigue load.ue load. load.d.

  • PDF