• Title/Summary/Keyword: $N_2$-Fixation

Search Result 260, Processing Time 0.021 seconds

Implementation of curved type a metallic plate system at the Bone contact (골 접촉 곡선형 금속 고정 시스템 구현)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.285-292
    • /
    • 2007
  • This study was developed the metallic plate for fixation in the femur fracture for the orthopedic region and rigid fixation with plates has a firm place in fracture treatment. Most plates can be used for rigid as well as biological and dynamical fracture fixation. The device's designation and sizing has a specific with bending structural stiffness and strength, known meaning that is reliable regardless of the plate by the short type and long type. Short plate have a wrapping of femur and long plate have to preserve a pole of femur. The bending strength of the curved metallic long plate has to evaluate a 11,000N and The bending strength of the curved metallic short plate has to evaluate a 6,525N. The tensile stress through to press a plate is $1573N/m^2\;and\;1539N/m^2$. The device can be used to support Revision case of Hip Implant and to use a case of Hip screw compression of Hip Neck Fracture.

  • PDF

Nitrogen fixation, and growth characteristics of Three Legume cover crops in no-tillage paddy field

  • Cho, Young-Son
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.4
    • /
    • pp.308-315
    • /
    • 2003
  • A field experiment was conducted to investigate the performance of three legume species in a zero-tillage, non-fertilized rice field in a temperate zone. Before the experiment for 5 years, from 1995 to 1999, plant growth patterns of three legume species grown as over-wintering (October-May) cover crops on a paddy field were maintained to study N balance and $\textrm{N}_2$ fixation. Decrease in plant density accelerated from after winter to flowering from 1,090, 320, and 5 to 732, 232, and 6 plants $\textrm{m}^{-2}$ in Chinese milk vetch (CMV), white clover (WC), and hairy vetch (HV), respectively. Total dry weights of plants above-ground level were 0.05, 0.11, and 2.43 g $\textrm{plant}^{-1}$. in WC, CMV and HV respectively but steeply increased at ripening up to 0.77, 2.33, and 26 g $\textrm{plant}^{-1}$. The root dry weight of HV and CMV rapidly increased while in WC, root dry weight increased slightly towards flowering. The highest nodule numbers were recorded in CMV to April thereafter WC produced the highest. Nodule size was distributed within 7mm in CMV but it was larger in HV varying from 1 to 10mm. Shoot N (g $\textrm{m}^{-2}$) greatly increased from over-wintering to flowering in CMV, HV and WC and it ranged from 1.66, 0.5 and 1.92 to 12.6, 3.1 and 13.02 g $\textrm{m}^{-2}$, respectively. After wintering, the initial shoot N content (%) was more in CMV. Root N content (%) was constant or slightly decreased in HV and WC. Soil total N in the control plot (clean fallow) was the highest on Mar. 2 then decreased rapidly to flowering. Soil N content was constant in HV plots whereas it was low in WC plots for the entire growth period except just after winter. Maximum nitrogenase activities were 9, 37.8, and 131 mol $\textrm{C}_2\textrm{H}_4$ $\textrm{plant}^{-1}$ $\textrm{hour}^{-1}$. in CMV, HV, and WC, respectively. Nitrogenase activity showed a direct correlation with nodule number, size and fresh weight. As a cover crop preceding a rice crop, CMV is more suited to colder regions due to its earlier ripening characteristics. Hairy vetch and WC are recommended for regions with a mild winter and a long summer owing to their late ripening and great N fixation activity.

Nitrogen Fixation of Legumes and Transfer to Grasses in Spring Paddy Soil (춘계답리작 토양에서 두과의 질소고정과 이의 화본과로의 이동)

  • Lee, Hyo-Won
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.27 no.3
    • /
    • pp.167-172
    • /
    • 2007
  • Manure recycle is an emerging issue in agriculture in Korea these days. Farmers are keeping eye on legume mixture with grasses for nitrogen fixation and transfer to companion crops by legumes. We had a trial to investigate the effect of different legume mixtures on nitrogen fixation and transfer in spring soil. The treatment was arranged in a randomized complete block design with three replications. Three different mixtures were used(rye+hairy vetch, Italian ryegrass+crimson clover, oat+pea) and sowed in pots with paddy soil from western part of Korea(Seo Chon County). Pots with rye+vetch were transplanted from field of RDA(rural development administration) in Suwon on 2 February 2007 and other mixture treatments were sowed on early March with different sowing rate(7:3=Italian:crimson, 6:4=oat:pea). $(^{15}NH_4)_2SO_4$ solution at. $99.8\;atom%^{15}N$ was applied to the each pot at the rate of $2kg\;N\;ha^{-1}$. Application was done on 6 April at rye+vetch pots and remainder were applied on April 16. Forage were harvested from each pot at ground level in heading stage and separated into legume and grass. Total N content and $^{15}N$ value were determined using a continuous flow stable isotope ratio mass spectrometry. DM yield of rye+vetch, Italian+crimson and oat+pea were 6,607, 3,213 and 4,312 kg/ha, respectively. Proportion of N from fixation was 0.73(rye+vetch), 0.42(Italian+crimson) and 0.93(oat+pea). The percentages of N transfer from legume to grass were from 61% to 24% in different method by treatment and -35% to 21% in isotope dilution method.

$N_2$Fixation and Partitioning of Nitrogen and Carbohydrate in White Clover as Affected by Defoliation Interval (예취주기가 White Clover의 질소고정과 질소 및 탄수화물 분배에 미치는 영향)

  • 강진호
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.1
    • /
    • pp.26-32
    • /
    • 1995
  • Weak persistence of white clover (Trifolium repens L.) under continuous grazing has been limited its availability in the mixture with grasses. The experiment was done to determine the effect of defoliation interval on $N_2$ fixation. nitrogen and carbohydrate partitioning of contrasting white clover cultivars. Individual plants of Osceola(large leaf), Grasslands Huia (me-dium leaf), and Aberystwyth S184 (small leaf) were grown in 15cm plastic pot containing a 1:2:1 soil:sand:Promix mixture for 55 days, and then clipped to remove all fully expanded leaves every 7, 14 or 28 days. To measure the cultivar response, plants were sampled immediately before final harvest (0) and on 1, 3, 7, 14, and 28 days after the final harvest, and then seperated leaves and petioles, stolons and roots for chemical analysis. Total nonstructural carbohydrate (TNC) concentrations of stolons and roots, and nitrogen con-centration of all the fractions inclined with increased defoliation interval. Those of Osceola, large leaved, were greater than the other cultivars showing different partitioning patterns between stolons and roots. Concentration of TNC was less in roots than in the other fractions while that of nitrogen declined in the order of leaves and petioles, roots and stolons. $N_2$ fixation rate of larger leaved cultivar, Osceola, was higher than that of smaller leaved cultivar. TNC and nitrogen concentrations of all the fractions and $N_2$ fixation rate were reduced as defoliation was imposed, defoliation interval declined or regrowing period become shorter. The partitioning patterns of TNC and nitrogen among the fractions were modified by defoliation interval and cultivars.

  • PDF

A Prospective Study with Cage-Only or Cage-with-Plate Fixation in Anterior Cervical Discectomy and Interbody Fusion of One and Two Levels

  • Kim, Sam Yeol;Yoon, Seung Hwan;Kim, Dokeun;Oh, Chang Hyun;Oh, Seyang
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.691-700
    • /
    • 2017
  • Objective : The authors prospectively analyzed the effect of one-level or two-level anterior cervical discectomy and fusion (ACDF), comparing stand-alone cages and cage-with-plate fixation constructs with respect to clinical outcomes and radiologic changes. Methods : A total of 84 patients who underwent one-level (n=52) or two-level ACDF (n=32) for cervical disc disease and who completed 2 years of follow-up were included in this study. The patients were divided by cervical level and grouped into ACDF-Cage-only and ACDF-Cage-with-plate groups. The following parameters were assessed using radiographs : subsidence, C2-C7 lordosis angle, fusion segment angle, adjacent disc space narrowing, and fusion status. Clinical outcomes were assessed using the neck disability index (NDI) and visual analog scale scores for arm pain. Results : In the comparison of one-level ACDF-cage-only and ACDF-cage-with-plate groups, the NDI score was better in the cage-only group at the 3-, 12-, and 24-month follow-ups : however, no significant difference in clinical outcomes was observed. In the comparison of two-level ACDF-cage-only and ACDF-cage-with-plate groups, no difference in any clinical outcome was observed between the two groups. At the 24-month follow-up, subsidence was observed in 45.8% of patients in the one-level cage-only group and 32.1% of patients in the one-level cage-with-plate fixation group. There was no statistically significant difference in the incidence rate between the two groups (p=0.312). Subsidence in the two-level cage-only group (66.6%) was significantly more frequent than in the two-level cage-with-plate fixation group (30%; p=0.049). The fusion rate for patients in the one-level cage-only group was not significantly different from that in the one-level cage-with-plate fixation group (cage-only, 87.5%; cage-with-plate fixation, 92.9%; p=0.425) ; fusion rate in the two-level patients were also similar between groups (cage-only, 83.3%; cage-with-plate fixation, 95%; p=0.31). Conclusion : Our clinical results showed that for single-level cases, plate fixation had no additional benefit versus cage-only; for two-level ACDF cases, the fusion rate and clinical outcomes were similar, although the cage-with-plate fixation group had a lower incidence of cage subsidence than did the cage-only group. We conclude that physicians should be aware of this possible disadvantage associated with using cervical plates in one-level ACDF. However, in two-level ACDF, subsidence is more likely to occur without plate fixation, and thus the addition of plate fixation should be considered.

Internal Fixation of Medpor® Implant for Prevention of Enophthalmos in Posteriorly Extended Orbital Floor Fracture (후방까지 연장된 안와하벽골절에서 안구함몰 예방을 위한 Medpor® 내고정술)

  • Suhk, Jeong Hoon;Ji, So Young;Kim, Tae Bum;Yang, Wan Suk
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.55-61
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effectiveness of internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw which is used for prevention of enophthalmos in posteriorly extended large orbital floor fracture. Methods: From Jun. 1997 to Dec. 2007, 21 patients who were diagnosed with posteriorly extended large orbital floor fractures were classified into two groups. One group(n=11) had undergone reduction surgery with regular $Medpor^{(R)}$ sheets without any fixation method, while the other group(n=10) had their $Medpor^{(R)}$ sheets fixed with the $BioSorb^{TM}FX$ screws. The two groups were evaluated by comparison of their enophthalmos degree and effectiveness. Results: In the non-fixation group, six patients had enophthalmos preoperatively and three of them showed persistent enophthalmos postoperatively. In postoperative CT examination, displacement of $Medpor^{(R)}$ implant with soft tissue impaction into maxillary sinus was observed in the patients. In the screw fixation group, three patients had enophthalmos preoperatively, but none of them suffer from complication such as residual enophthalmos, soft tissue impaction, muscle entrapment or optic nerve compression postoperatively. Conclusion: Internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw on the medial surface of orbital floor provides firm stabilization of implants and surrounding soft tissues and can be an effective option especially when postoperative implant displacement or malposition was expected.

Effect of Inoculation of Rhizobic on Sesbania nitrogen fixation (Sesbania 에 대(對)한 근류균접종(根瘤菌接種) 효과(效果)와 질소고정(窒素固定)에 관(關)한 연구(硏究))

  • Ahn, Sang Bae;Yoneyama, J.;Gamo, H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.4
    • /
    • pp.455-461
    • /
    • 1988
  • The pattern of nitrogen fixation by water culture of Sesbania, known as an effective legume plant for nitrogen fixation, in the growth cabinet by Leonard-Jar methods and nitrogen fixation pattern to sesbania are as follows: 1. Dry weight per pot after inoculation of rhizobia to sesbania was by the order for root + stem > root > control and nitrogen contents of plant parts also showed the same tendency as dry weight except leaf. 2. $^{15}N$ value based on natural abundance was by the order of root + stem > root > control, $^{15}N$ value of root nodule and stem nodule among total nitrogen content exhibited positive value but it showed negative value from root, stem and leaf.

  • PDF

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF

A comparison of fixation methods using three-dimensional finite element analysis following anterior segmental osteotomy

  • Yun, Kyoung In;Park, Min-Kyu;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.332-336
    • /
    • 2012
  • Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park's method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.

What are the Differences in Outcome among Various Fusion Methods of the Lumbar Spine?

  • Kang, Suk-Hyung;Kim, Young-Baeg;Park, Seung-Won;Hong, Hyun-Jong;Min, Byung-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.1
    • /
    • pp.39-43
    • /
    • 2005
  • Objective: For Posterior lumbar interbody fusion(PLIF) various cages or iliac bone dowels are used with or without pedicle screw fixation(PSF). To evaluate and compare the clinical and radiological results of different fusion methods, we intend to verify the effect of added PSF on PLIF, the effect of bone cages and several factors which are thought to be related with the postoperative prognosis. Methods: One hundred and ninety seven patients with lumbar spinal stenosis and instability or spondylolisthesis underwent various fusion operations from May 1993 to May 2003. The patients were divided into five groups, group A (PLIF with autologous bone dowels, N=24), group B (PLIF with bone cages, N=13), group C (PLIF with bone dowels and PSF, N=37), group D (PLIF with bone cages and PSF, N=30) and group E (PSF with intertransverse bone graft, N=93) for comparison and analyzed for the outcome and fusion rate. Results: Outcome was not significantly different among the five groups. In intervertebral height (IVH) changes between pre- and post-operation, Group B ($2.42{\pm}2.20mm$) was better than Group A ($-1.33{\pm}2.05mm$). But in the Group C, D and E, the IVH changes were not different statistically. Fusion rate of group C, D was higher than that of Group A and B. But the intervertebral height(IVH) increased significantly in group B($2.42{\pm}2.20mm$). Fusion rate of group C and D were higher than that of group A and D. Conclusion: Intervertebral cages are superior to autologous iliac bone dowels for maintaining intervertebral height in PLIF. The additional pedicle screw fixation seems to stabilize the graft and improve fusion rates.