• Title/Summary/Keyword: $Moir\'{e}$

Search Result 61, Processing Time 0.026 seconds

Elastoplastic Behavior and Creep Analysis of Solder in a FC-PBGA Package (플립 칩 패키지 솔더의 탄소성 거동과 크립 해석)

  • Choi, Nam-Jin;Lee, Bong-Hee;Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.2
    • /
    • pp.21-28
    • /
    • 2010
  • Creep behaviors of the solder balls in a flip chip package assembly during thermal cycling test is investigated.. A material models used in the finite element analysis are viscoplastic model introduced by Anand and creep model called partitioned model. Experiment of two temperature cycles using moir$\acute{e}$ interferometry is conducted to verify the reliability of material models for the analysis of thermo-mechanical behavior. Bending deformations of the assemblies and average strains of the solder balls due to temperature change and dwell time are investigated. The results show that time-dependent shear strain of solder by the partitioned model is in excellent agreement with those by moir$\acute{e}$ interferometry, while there is considerable difference between results by Anand model and experiment. In this paper, the partitioned model is employed for the time-dependent creep analysis of the FC-PBGA package. It is also shown that the thermo-mechanical stress becomes relaxed by creep behavior at high temperature during temperature cycles.

Thermo-mechanical Deformation Analysis of Filu Chip PBGA Packages Subjected to Temperature Change (Flip Chip PBGA 패키지의 온도변화에 대한 변형거동 해석)

  • Joo, Jin-Won;Kim, Do-Hyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.4
    • /
    • pp.17-25
    • /
    • 2006
  • Thermo-mechanical behavior of flip-chip plastic ball grid array (FC-PBGA) packages are characterized by high sensitive $moir\'{e}$ interferometry. $Moir\'{e}$ fringe patterns are recorded and analyzed for several temperatures. Deformation analysis of bending displacements of the packages and average strains in the solder balls for both single and double-sided package assemblies are presented. The bending displacement of the double-sided package assembly is smaller than that of the single-sided one because of its symmetric structure. The largest effective strain occurred at the solder ball located on the edge of the chip and its magnitude of the double-sided package assembly is greater than that of single-sided one by 50%.

  • PDF

A Scheme of Improving Propagation Attack Protection and Generating Convergence Security Token using Moire (무아레를 이용한 융합 보안토큰생성과 전파공격 보호 기법)

  • Lee, Su-Yeon;Lee, Keun-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.7-11
    • /
    • 2019
  • Due to diversification and popularization of devices that use rapid transmission, there are many security issues related to radio waves. As the disturbance and interference of the radio wave can cause a direct inconvenience to a life, it is a very important issue. In this paper, as a means to prevent radio disturbance and interference, the projected image of the reference grid and the deformed grid is obtained by measuring the projected $moir{\acute{e}}$ using the white light source, projecting grid and the light source, and a $moir{\acute{e}}$ pattern is generated with an image processing algorithm by applying a phase diagram algorithm, and generated $moir{\acute{e}}$ pattern phase diagram creates a three-dimensional shape. By making an encrypted token using this measured face shape, the transmission of the information through token ring is determined in order to transmit the horizontal transmission having the dynamic security characteristics which includes authentication strength and caller information, etc. And by confirming the uniqueness of the token and by sending and receiving the horizontal transmission using java serialization and deserialization function, a problem solving method is suggested.

Assessment of the Breast-Firmming Effects of a Cosmetic Preparation with Moir$\acute{e}$ Tophography in Combination with 2D and 3D Digital Image Analyses (2D 및 3D 디지털 이미지 분석과 함께 Moir$\acute{e}$ Tophography 분석을 이용한 화장품의 가슴 탄력개선 효과 평가)

  • Seo, Young Kyoung;Yoo, Mi Ae;Ryu, Ja Hyun;Kim, So Jeong;Cho, Seong A;Nam, Gae Won;Cho, Jun-Cheol;Boo, Yong Chool;Koh, Jae-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • Cosmetic products which might augment the breast have attracted an attention and objective methods for the evaluation of such products are in high demand. This study was conducted to establish a method for assessing the breast-firmming effects of cosmetics. This study included a total of 30 healthy Korean females aged 20-50 years. A cosmetic product was applied by massaging it onto the breast twice a day for 8 weeks. Measurement of breast girth with a tape ruler, 2D and 3D digital image analyses, and Moir$\acute{e}$ topographic analysis were performed before and following the treatment. The application of a cosmetic onto the breast significantly increased breast girth at 2, 4 and 8 weeks without a significant change in underbreast girth, implicating the breast might be augmented. The 2D image analysis indicated that the arc length of the breast which represents the surface distance from the nipple to the periphery of the under-breast was significantly increased at 2, 4 and 8 weeks. The height of the breast which represents the perpendicular distance from the nipple to the periphery of the under-breast was also increased significantly at 4 and 8 weeks. The 3D image analysis of body surface also demonstrated a significant increase of breast volume at 2, 4 and 8 weeks. Moir$\acute{e}$ topographic analysis indicated that breast sagging was significantly reduced at 2, 4 and 8 weeks. The results of this study suggest that Moir$\acute{e}$ topography in combination with 2D and 3D digital image analyses may be useful for evaluating the breast-augmenting effects of cosmetics.

Non-linear Temperature Dependent Deformation Anaysis of CBGA Package Assembly Using Moir′e Interferometry (모아레 간섭계를 이용한 CBGA 패키지의 비선형 열변형 해석)

  • 주진원;한봉태
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.1-8
    • /
    • 2003
  • Thermo-mechanical behavior of a ceramic ball grid array (CBGA) package assembly are characterized by high sensitive moire interferometry. Moir fringe patterns are recorded and analyzed at various temperatures in a temperature cycle. Thermal-history dependent analyses of global and local deformations are presented, and bending deformation (warpage) of the package and shear strain in the rightmost solder ball are discussed. A significant non-linear global behavior is documented due to stress relaxation at high temperature. Analysis of the solder interconnections reveals that inelastic deformation accumulates on only eutectic solder fillet region at high temperatures.

  • PDF

A Study on MBES Error Data Removing using Motion Sensor (Motion Sensor를 이용한 MBES 오측자료 제거 연구)

  • Kang, Moon-Kwon;Choi, Yun-Soo;Chang, Min-Chol;Yoon, Ha-Su
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Sounding data is the essential source for the safety of ships navigation system, and fundamental to the reasonable usage and maintenance of the ocean as well. As IT tech, positioning equipment such as GPS and INS, echo sounder are developed, recently, the precise submarine topography database bas been built by Multi-Beam Echo Sounder. However, MBES data includes some inevitable error caused by several factor, and some data have errors where the terrain is wobble. The error, which causes the $moir\acute{e}$ pattern error is the main factor hindering the accuracy of MBES data results, and therefore it is necessary to figure out the main cause of the error for the improvement of the accuracy by removing error data. On this research, the main cause of the error data is studied by analyzing motion sensor value of data including the $moir\acute{e}$ pattern error. Thus, as the result of examination, it turns out that the $moir\acute{e}$ pattern error is related to the standard deviation of Roll, and error data values are results of the non-correspondence between Swath data and Roll values caused by the drastic change of Roll values. Accordingly, the error data is removed by comparing between the gradient of Swath data and Roll values. Finally, as the result of removing error data, it is expected to be able to estimate the quality of MBES using the standard deviation of Motion sensor's Roll value, and calculate the additive error factor, which minimize non-corresponding data, and also this research must be contributed to improve the accuracy of sounding for small vessels with lots of motion in the bad circumstance for navigation.

Material Parameters Identification of Adhesive in Layered Plates Using Moiré Interferomety and Optimization Technique (무아레 간섭계 측정과 최적화 기법을 이용한 적층판의 접착제 물성치 규명)

  • Joo, Jin-Won;Kim, Han-Jun;Lee, Woo-Hyuk;Kim, Jin-Young;Choi, Joo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.11
    • /
    • pp.1100-1107
    • /
    • 2007
  • In this study, a method to characterize material properties of adhesive that is used in a layered plates bonding process is developed by combined evaluation of experiment, simulation and optimization technique. A small bonded specimens of rectangular plate are prepared to this end, and put into a thermal loading conditions. $Moir{\acute{e}}$ interferomety is used to measure submicron displacements occurred during the process. The elevated temperature is chosen as control factors. FE analysis with constant values for the adhesive materials is also carried out to simulate the experiment. Significant differences are observed from the two results, in which the simulation predicts the monotonic increase of the bending displacement whereas the measurement shows decrease of the displacement at above $75^{\circ}C$. In order to minimize the difference of the two, material parameters of the adhesive at a number of different temperatures are posed as unknowns to be determined, and optimization is conducted. As a result, optimum material parameters are found that excellently matches the simulation and experiment, which are decreased with respect to the temperature.

A Study on the Variation of the Skin Surface According to Arm Movement by $Moir\'{e}$ Photography Method -In the area of uppearm and shoulder blade- ($Moir\'{e}$ Photography법에 의한 동작시 체표면 형태 변화에 관한 연구 -상지 및 견갑골 부위를 중심으로-)

  • Kim Haekyung;Cho Jungmee;Suh Chuyeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.4 s.36
    • /
    • pp.292-304
    • /
    • 1990
  • The surface change of upperarm and shoulder blade area are caused by the extensive upper limb movement, thus it is necessary to measure the amount of change for constructing the clothing. Moire photography was taken after plastic casters of upperarm and shoulder blade area was prepared. 1. For the shoulder blade area, subjects showed the same change of surface area for the various limb positions, wherease, for the upperarm only at the $0^{\circ}\;and\;180^{\circ}$ limb position, same change was observed. 2. As the movement of the upperarm was increased, surface area of axillary part was increased and that of shoulder part was decreased. 3. To make a bodice pattern, the minimum size of the back with the ease were $\frac{B}{4}$+3.13 cm R for normal wear and $\frac{B}{4}$+5.75 cm for active wear. 4. As the movement of the arm was increased, the cross section for the upperarm were changed to elliptical shape. 5. For each horizontal basic line, there was a positive correlation between the amount of change of shoulder blad area and that of upperarm area.

  • PDF

A Study on the Improvement of Accuracy of Surface Measurement in the Phase-Shifting Shadow Moir$\'{e}$ Method (위상이동 그림자 무아레방법을 이용한 형상측정법의 정확도 개선에 관한 연구)

  • 강영준;유원재;권용기
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.96-102
    • /
    • 1998
  • In this study, the theory and application of phase-shifting shadow moire topography is focused on the non-contact measurement of object surfaces for practical use in the field of production engineering. Shadow moire topography has been studied during last few decades in the area of the optical physics, and now its mathmatical theory has been established. Generally, in case of the classical shadow moire topography, the sensitivity is a few tenths of millimeter in best cases. Here we tried the application of phase-shifting method to the conventional shadow moire topography. But the reference grating and the deformed grating are mutually dependent because it is impossible to obtain uniform phase shifts on the whole Held. Therefore it is difficult to use a phase-shifting method in shadow moire topography. However, it was shown that constant phase-shifting was able to be measured by moving both the grating and light source. Finally we obtained a better result by using this procedure and applied the phase-shifting shadow moire to three dimensional object measurement.

  • PDF

Research on Subcutaneous Pulse Shape Measurement by Near-infrared Moiré Technique

  • Chen, Ying-Yun;Liu, Zhizhen;Du, Jian;Chang, Rong-Seng
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • A pulse is generated when the heart pumps blood into the arterial system. The heart pumps blood only when it contracts, not when it relaxes; therefore, blood enters the arterial system in a cyclical form. Artery beating is visible in some parts of the body surface, such as the radial artery of the wrist. This paper mainly uses the feature in which near-infrared spectroscopy penetrates skin to construct a non-invasive measurement system that can measure small vibration in the subcutaneous tissue of the human body, and then uses it for the pulse measurement. This measurement system uses the optical moir$\acute{e}$ principle, together with the fringe displacement made by small vibration in the subcutaneous tissue, and an image analysis program to calculate the height variation from small vibrations in the subcutaneous tissue. It completes a measurement system that records height variation with time, and that together with a fast Fourier transform (FFT) program, they can convert the pulse waveform generated by vibration (time-amplitude) to heartbeat frequency (frequency-amplitude). This is a new and non-invasive medical assistance system for measuring the pulse of the human body, with the advantages of being simple, fast, safe and objective.