• Title/Summary/Keyword: $MICS$

Search Result 303, Processing Time 0.02 seconds

Ultra-Low Power MICS RF Transceiver Design for Wireless Sensor Network (WSN 을 위한 초저전력 MICS RF 송수신기 기술 개요 및 설계 기법)

  • Gyu-won Kim;Yu-jung Kim;Junghwan Han
    • Transactions on Semiconductor Engineering
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 2024
  • This paper discusses the design of bio-implanted ultra-low-power MICS RF transceivers for wireless sensor networks. The 400 MHz MICS standard was considered for the implementation of the WBAN wireless sensor system, indirectly minimizing radio propagation losses in the human body and the inference with surrounding networks. This paper includes link budget, various transmission and reception architectures for a system design and ultra-low power transceiver circuit techniques for the implementation of RF transceivers that meet MICS standards.

The Marital Interaction Coding System-Global(MICS-G): A Validation Study (포괄적 부부상호작용 코딩시스템(MICS-G) 국내 타당화 연구)

  • Park, Woochul
    • Human Ecology Research
    • /
    • v.57 no.1
    • /
    • pp.109-125
    • /
    • 2019
  • Few studies have utilized observational methods in the field of couple research even though using self-report questionnaires is prone to the subjective biases of the reporter. This study validates the Marital Interaction Coding System-Global (MICS-G), a global version of the well-established microanalytic observational coding system, Marital Interaction Coding System (MICS). Participants in the study consisted of 30 married couples with varied levels of marital adjustment who visited one of the Healthy Family and Multicultural Family Support Centers in Seoul, either for couple therapy or the "Marriage Checkup"program. Ten-minute problem-solving discussions were rated by two undergraduate student raters who were trained for 10 hours. Interobserver agreement based on percentage agreement and intraclass correlation coefficients showed a high level of agreement between raters in establishing interrater reliability. Convergent validity was established by: correlations among marital adjustment, psychological aggression, mental health, and MICS-G categories of conflicts, validation, invalidation, facilitation, and withdrawal. MICS-G categories also were successful in discriminating between distressed and nondistressed couples, which provides evidence of discriminant validity for MICS-G. This study showed that MICS-G is a promising method for researchers to observe couple interactions in a more cost-effective way. Methodological issues and practical applications are also discussed.

Design of a Dual-Band On-Body Antenna for a Wireless Medical Repeater System (의료용 무선 중계 시스템용 이중 대역 인체 부착형 안테나 설계)

  • Kwon, Kyeol;Tak, Jinpil;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.239-246
    • /
    • 2013
  • In this paper, a dual-band on-body antenna operating at MICS and ISM band for a wireless medical repeater system is proposed and the antenna performance including the human body effect is investigated. The designed dual-band antenna is comprised of a top patch for ISM band and bottom patch for MICS band. Simulation and measurement was carried out in order to analyze the effects of human body on antenna performance considering real use. The proposed antenna has required impedance bandwidth enough to cover both MICS and ISM bands. The measured peak gains were -12.47 dBi and 1.71 dBi at the each center frequency of MICS and ISM bands, respectively. Furthermore, the antenna has the maximum radiation directed toward the inside of the human body in the MICS band and directed toward the outside in the ISM band. In addition, the return loss property of the antenna is insensitive to human body effects so that the proposed antenna is well suited for the on-body wireless medical repeater system.

A High Data Rate Medical Implant Communication System Transmitter for Body Implantable Devices (체내이식용 기기를 위한 고속 MICS 송신기 구현)

  • Im, Jun-Ha;Jung, Yun-Ho;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.4
    • /
    • pp.24-31
    • /
    • 2011
  • A high data rate Medical Implant Communications Service (MICS) transmitter for implantable medical devices (IMD) is proposed. An orthogonal frequency division multiplexing (OFDM)-based multicarrier scheme is used to overcome the data rate limitation caused by the narrow bandwidth of 300 kHz. The proposed transmitter utilizes multiple MICS channels simultaneously, supporting increased data rate. To satisfy the MICS regulation, various schemes are applied including optimized subcarrier allocation and inverse fast Fourier transform (IFFT) architecture, and additional sidelobe suppression technique. Simulation results show that the proposed transmitter can support a maximum data rate of 4.86 Mbps, which is more than ten times faster than the previous systems.

Effect of Culture Medium on Results of Maerobroth Dilution Antifungal Susceptibility Testing of Candida albicans (Candida albicans의 시험관 희석법에 의한 항균력 검사시 배지가 항균력에 미치는 영향)

  • Koh, Choon-Myung;Kim, Soo-Ki
    • The Journal of the Korean Society for Microbiology
    • /
    • v.22 no.3
    • /
    • pp.301-307
    • /
    • 1987
  • A total of 42 strains of Candida albicans were examined for susceptibility to three antifungal agents, amphotericin B(AMB), 5-fluorocytosine(5-FC), and ketoconazole(KTZ), using defined medium, synthetic amino acid medium-fungal(SAAM-F), supplemented yeast nitrogen base(SYNB) and undefined medium Sabouraud's dextrose broth(SDB) and Kimmig broth media. A tube dilution method was used with minimum inhibitory concentrations(MICs) determined after incubation for 24 hour and 48 hours. All testes were performed in duplicate. In general, MICs were more reproducible after 48 hour of incubation. Forthermore, MICs determined after incubation for 48 hours were significantly higher than those determined after 24 hours. The actural MICs obtained with the different antifungal agents were clearly influenced by the test medium used. The rank order of AMB MICs according to the test medium was as follows: SAAM-F>SYNB>SDB>Kimmig broth. With 5-FC, the following pattern was observed: SYNB>SAAM-F>SDB>Kimmig borth. For ketoconazole, the MICs according to the test medium was SAAM-F>SDB>SYNB> Kimmig broth. In amphotericin B, the MICs mean value with the test medium was as follows: SDB, 0.24 mcg/ml; Kimmig broth, 0.29 mcg/ml; SYNB, 0.21 mcg/ml and SAAM-F, 0.15mcg/ml. The actural value of 5-FC was; SDB, 37.20 mcg/ml; Kimmig broth, 67.41mcg/ml; SYNB, 21.29 mcg/ml and SAAM-F, 24.61 mcg/ml and in ketoconazole, the MICs value was; SDB, 1.83 mcg/ml; Kimmig broth, 4.08 mcg/ml; SYNB, 1.95 mcg/ml and SAAM-F, 1.41 mcg/ml. The results of this investigation suggested that broth dilution susceptibility testing of yeast and yeast-like fungi are best performed with an incubation period of 48 hours. Furthermore, medium composition can significantly influence the results of such testing.

  • PDF

Design of a WBAN Repeater Antenna for MICS and ISM Bands (MICS와 ISM 대역을 위한 인체 통신 중계용 안테나 설계)

  • Lee, Ho-Joo;Kwon, Kyeol;Lee, Soon-Yong;Choi, Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.314-319
    • /
    • 2012
  • In this paper, a repeater antenna operating at MICS and ISM bands is proposed and the antenna performance including the human body effect is investigated. The proposed antenna is composed of a ZOR(Zeroth Order Resonator) and a loop antenna. A loop antenna is operated at ISM band and a loop antenna capacitively coupled with a ZOR acts as an antenna for MICS band. Simulation was carried out in order to analyze the effects of human body on antenna performance when a human body is located in the near field of an antenna. According to the simulated and measured results, the proposed antenna has -10 dB $S_{11}$ bandwidth wide enough to cover both MICS and ISM bands. The measured peak gains are -28.53 dBi and 3.85 dBi at MICS and ISM band, respectively. The dual band and radiation properties of the proposed antenna are well suited for the WBAN repeater system.

Design and Implementation of Server System for MICS(Medical-Image Conference System) based on CORBA (의료영상 회의시스템을 위한 CORBA기반의 서버시스템의 설계 및 구현)

  • 박세명;강재효;김상균;최항묵;최흥국
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.6
    • /
    • pp.557-565
    • /
    • 2000
  • According to CORBA specification, there are some mechanisms for object reference management such as Naming Service and Trading service, but these mechanism cant's supply all functionalities needed fomanagement in MICS. So, We have designed and implemented additional special-purpose IPO manager. It provides load balancing service based on real-time information for IPO and fault-tolerable services with the management of redundant IPOs and also provides transparent configuration of client environment with the lists of registered IPOs.

  • PDF

In vitro Evaluation of Antimicrobial Agents Susceptibility Against Several Clinical Isolates (임상 분리 균주의 항생제 감수성 유형)

  • 최성숙;하남주
    • YAKHAK HOEJI
    • /
    • v.43 no.1
    • /
    • pp.128-130
    • /
    • 1999
  • In vitro activity of commonly used antimicrobial agents against several clinical isolates were studied. In the case of E. coli, the MICs at which 90% of the bacteria are inhibited of ampicillin, Unasyn, cefazoline, cefotaxim, carbenicillin, gentamicin and ofloxacin were 100<, 100, 25, 0.2, 100<, 3.13, and $12.5{\;}\mu\textrm{g}/m$ , respectively. In the case of K . pneumoniae, the MICs at which 90% of the bacteria are inhibited of ampicillin, Unasyn, crfazoline, cefotaxim, carbenicillin, gentamicin and ofloxacin were 100<, 12.5, 100<, 0.1, 100<, 1.6, and $0.4{\;}\mu\textrm{g}/m$ , respectively. In the case of Enterobacter sp, the MICs at which 90% of the bacteria are inhibited of ampicillin, Unasyn, cefazoline, cefotaxim, carbenicillin, gentamicin and ofloxacin were 100<, 100, 100<, 6.25, 100<, 100 and $1.57{\;}\mu\textrm{g}/m$ , respectively. In the case of Acinetobacter sp, the MICs at which 90% of the bacteria are inhibited of ampicillin, Unasyn, cefazoline, cefotaxim, carbenicillin, gentamicin and ofloxacin were 100<, 100<, 100<, 100<, 100< 100< and $50{\;}\mu\textrm{g}/m$ , respectively. In the case of Pseudomonas sp, the MICs at which 90% of the bacteria are inhibited of ampicillin, Unasyn, cefazoline, cefotaxim, carbenicillin, gentamicin and ofloxacin were 100<, 100<, 100<, 50, 100<, 25 and $25{\;}\mu\textrm{g}/m$, respectively. In the case of S. aureus, the MICs at which 90% of the bacteria are inhibited of ampicillin, Unasyn, cefazoline, cefotaxim, carbenicillin, gentamicin and ofloxacin were 50, 50, 100<, 100<, 50, 50, and $100{\;}\mu\textrm{g}/m$, respectively.

  • PDF

The Study on Implementation of a Semi-Solid Flat Phantom with Equivalent Electrical Properties to Whole Human Body at MICS and ISM Band (MICS 대역과 ISM 대역에서 인체 전기적 상수를 갖는 준(準) 고체형 플랫 팬텀 제작)

  • Lee, Soon-Yong;Seo, Won-Bum;Kwon, Kyeol;Choi, Jea-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.101-107
    • /
    • 2012
  • When wireless devises for MICS(Medical Implant Communication Service) or ISM(Industrial Scientific and Medical) bands are designed, it is necessary to verify the performance by using a human body flat phantom. However, most of studies on the phantom are limited to the biological effects of mobile-phone EMF. In this paper, semi-solid phantoms having the electric properties suggested by FCC at MICS and ISM bands are fabricated. The manufactured phantoms satisfy the electric properties($\varepsilon_r=56.7$ and $\sigma=0.94$ at MICS band, $\varepsilon_r=52.7$ and $\sigma=1.95$ at ISM band) at each band. All the composing materials for phantoms are commercially available in domestic market. Two methods using both polyethylene powder and TX-151 and glycerin at each band are proposed for diverse purpose. The electrical properties of the fabricated phantoms are measured by a dielectric probe kit and network analyzer after the lapse of one day (24 hours).

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.