• Title/Summary/Keyword: $K^+-channel$

Search Result 11,814, Processing Time 0.049 seconds

The Sensitivity Analysis according to Observed Frequency of Daily Composite Insolation based on COMS (관측 빈도에 따른 COMS 기반의 일 평균 일사량 산출의 민감도 분석)

  • Kim, Honghee;Lee, Kyeong-Sang;Seo, Minji;Choi, Sungwon;Sung, Noh-Hun;Lee, Darae;Jin, Donghyun;Kwon, Chaeyoung;Huh, Morang;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.733-739
    • /
    • 2016
  • Insolation is an major indicator variable that can serve as an energy source in earth system. It is important to monitor insolation content using remote sensing to evaluate the potential of solar energy. In this study, we performed sensitivity analysis of observed frequency on daily composite insolation over the Korean peninsula. We estimated INS through the channel data of Communication, Ocean and Meteorological Satellite (COMS) and Cloud Mask which have temporal resolution of 1 and 3 hours. We performed Hemispherical Integration by spatial resolution for meaning whole sky. And we performed daily composite insolation. And then we compared the accuracy of estimated COMS insolation data with pyranometer data from 37 points. As a result, there was no great sensitivity in the daily composite INS by observed frequency of satellite that accuracy of the calculated insolation at 1 hour interval was $28.6401W/m^2$ and 3 hours interval was $30.4960W/m^2$. However, there was a great difference in the space distribution of two other INS data by observed frequency of clouds. So, we performed sensitivity analysis with observed frequency of clouds and distinction between the two other INS data. Consequently, there was showed sensitivity up to $19.4392W/m^2$.

Determination of dynamic threshold for sea-ice detection through relationship between 11 µm brightness temperature and 11-12 µm brightness temperature difference (11 µm 휘도온도와 11-12 µm 휘도온도차의 상관성 분석을 활용한 해빙탐지 동적임계치 결정)

  • Jin, Donghyun;Lee, Kyeong-Sang;Choi, Sungwon;Seo, Minji;Lee, Darae;Kwon, Chaeyoung;Kim, Honghee;Lee, Eunkyung;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.2
    • /
    • pp.243-248
    • /
    • 2017
  • Sea ice which is an important component of the global climate system is being actively detected by satellite because it have been distributed to polar and high-latitude region. and the sea ice detection method using satellite uses reflectance and temperature data. the sea ice detection method of Moderate-Resolution Imaging Spectroradiometer (MODIS), which is a technique utilizing Ice Surface Temperature (IST) have been utilized by many studies. In this study, we propose a simple and effective method of sea ice detection using the dynamic threshold technique with no IST calculation process. In order to specify the dynamic threshold, pixels with freezing point of MODIS IST of 273.0 K or less were extracted. For the extracted pixels, we analyzed the relationship between MODIS IST, MODIS $11{\mu}m$ channel brightness temperature($T_{11{\mu}m}$) and Brightness Temperature Difference ($BTD:T_{11{\mu}m}-T_{12{\mu}m}$). As a result of the analysis, the relationship between the three values showed a linear characteristic and the threshold value was designated by using this. In the case ofsea ice detection, if $T_{11{\mu}m}$ is below the specified threshold value, it is detected as sea ice on clear sky. And in order to estimate the performance of the proposed sea ice detection method, the accuracy was analyzed using MODIS Sea ice extent and then validation accuracy was higher than 99% in Producer Accuracy (PA).

Swell Effect Correction for the High-resolution Marine Seismic Data (고해상 해저 탄성파 탐사자료에 대한 너울영향 보정)

  • Lee, Ho-Young;Koo, Nam-Hyung;Kim, Wonsik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.240-249
    • /
    • 2013
  • The seismic data quality of marine geological and engineering survey deteriorates because of the sea swell. We often conduct a marine survey when the swell height is about 1 ~ 2 m. The swell effect correction is required to enhance the horizontal continuity of seismic data and satisfy the resolution less than 1 m. We applied the swell correction to the 8 channel high-resolution airgun seismic data and 3.5 kHz subbottom profiler (SBP) data. The correct sea bottom detection is important for the swell correction. To detect the sea bottom, we used maximum amplitude of seismic signal around the expected sea bottom, and picked the first increasing point larger than threshold value related with the maximum amplitude. To find sea bottom easily in the case of the low quality data, we transformed the input data to envelope data or the cross-correlated data using the sea bottom wavelet. We averaged the picked sea bottom depths and calculated the correction values. The maximum correction of the airgun data was about 0.8 m and the maximum correction of two kinds of 3.5 kHz SBP data was 0.5 m and 2.0 m respectively. We enhanced the continuity of the subsurface layer and produced the high quality seismic section using the proper methods of swell correction.

Selection of Insecticide Resistance Markers in Field-collected Populations of Myzus persicae (복숭아혹진딧물 야외개체군의 살충제 저항성 마커 선발)

  • Kim, Ju Il;Kwon, Min;Shim, Jae Dong;Kim, Jeom Soon;Lee, Yeong Gyu;Jee, Sam Nyu;Lee, Jeong Tae;Ryu, Jong Soo;Yoo, Dong Lim;Lee, Gye Jun
    • Korean journal of applied entomology
    • /
    • v.53 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • The resistance levels of the green peach aphid, Myzus persicae (Sulzer), against 10 insecticides was checked and selected the applicable insecticide resistance markers. We conducted our study in 5 cabbage cultivation regions (Pyeongchang, Hongcheon, Bongwha, Muju, and Jeju) of Korea, over 3 successive years (2009-2011). We selected a multi-resistant (MR) strain from among the 5 field-collected populations. We analyzed esterase over-expression and mutation(s) in the target sites, by using native isoelectric focusing (IEF) and quantitative sequencing (QS). We detected esterase over-expression and StoF mutation in the acetylcholinesterase 1 gene (ace1) in all of the field-collected populations, including the MR strain. We did not detect the LtoF mutation, which is a well-known knockdown resistance (kdr) mutation in the para-type sodium channel gene (para), in the MR strain; however, the value of the MR strain for bifenthrin was 3,461-fold higher than that of the susceptible strain. Our results indicate that insecticide resistance is more effectively evaluated using molecular markers than by conducting a bioassay. The molecular markers StoF in ace1 and MtoL in para can easily be applied in diagnostic methods such as QS or PCR amplification of specific alleles (PASA). These methods may be extended to management of M. persicae resistance in the field.

Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations (전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, Jong-Hak;Lee, Ki-Yeol;Kim, Hyung-Cheol;Kim, Jang-Seob;Shin, Dong-Chul;Lee, Sung-Hyun;Lee, Jun-Hyub;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.453-460
    • /
    • 2009
  • The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of $2{\times}0.5\;mm$, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.

Assessment of fish fineness ratios passing through a fishway (어도를 통과하는 어류의 형태 체형비 평가)

  • Moon, Woon-ki;Bae, Dae-Yeul;Kim, Do-Hyun;Shin, Hyun-Beom;Suh, Jung Bin;Lim, Kyeong Hun;Lee, Eui-Haeng;Yoo, Jae-Sang;An, Kwang-Guk;Kim, Jai-Ku
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.726-734
    • /
    • 2019
  • To understand the relationship between water velocity in a fishway and fish morphology, the fineness ratio of fish, expressed as the standard length to the body depth, was measured. The fineness ratios of fish groups belonging to Cyprinidae, Acheilognathinae, Centropomidae, and Centrachidae were relatively low. The FRs of other groups, excluding eel-shaped types of fish, were over 4.5, indicating streamlined structures. The fineness ratios of Korean fish were classified into three different types: type I was Bitterling-Carp group that favored a slow-flowing pool habitat(FRs ranged from 2.1 to 3.3), type II was the Chub group representing streamlined types (FRs FRs ranged from 3.7 to 5.2), and type III was the Smelt-Barbel fish group that preferred riffle-run habitats with high velocity (FRs is over 5.2). Fish abundance analysis of fish using the fishway during the experimental periods showed a relatively high abundance of both type II and III compared to type I. The FRs of the fish passing through fishway(velocity 0.5-1.0 m s-1) ranged from 4.5 to 5.0, indicating that the fish using the fishway were mainly the streamlined type. As one of the standard fishways in Korea, the flow rate of the ice harbor type ranged from 0.2 to 2.6 m s-1. The FR values of the fish groups using the fishway ranged from 4.3 to 5.0. In contrast, the flow rate measured in an artificial channel type of fishway (same as a natural type of fishway) ranged from 0.1 to 1.9 m s-1 and the FR values for the fish groups using a natural type of fishway ranged from 3.3 to 5.3. The low FR values in natural fish are considered to be due to differences in the flow rates between the two types of fishways.

Effects of Cyclobuxine E on Two Distinct Types of Potassium-Activated Calcium Channels in an Intestinal Smooth Muscle (흰쥐 장관에 있어 칼륨에 의해 활성화되는 칼슘 채널에 대한 Cyclobuxine E의 영향)

  • Lee, Jong-Hwoa;Kwon, Jun-Tack;Cho, Byung-Heon;Choi, Kyu-Hong;Kim, Yu-Jae;Kim, Jong-Bae;Kim, Chun-Sook;Cha, Young-Deog;Kim, Young-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.25 no.1
    • /
    • pp.53-58
    • /
    • 1989
  • For several years, we investigated the pharmacological action of several substances isolated from Buxus microphylla var koreana Nakai, which had been used as folk remedies of malaria and venereal disease. Cyclobuxine $D(C_{25}H_{42}ON_2)$, a steroidal alkaloid, exerted an antiinflammatory action, hypotensive and bradycardic effects in rats. In the present study, we isolated alkaloid from the acetone-insoluble fraction of the strong bases of this plants. This alkaloid $(C_{25}H_{38}ON_2)$ was identified as a steroidal alkaloid contained a cyclopropane ring by physical and chemical methods. It is a derivative of cyclobuxine D and named cyclobuxine E. We examined the effect of cyclobuxine E on the contractile response induced by acetylcholine and two distinct types of potassium-activated calcium channels in an intestinal smooth muscle of the rat. Cyclobuxine E inhibited significantly the Ach-induced contraction. The isolated longitudinal muscle from the rat duodenum was immersed calcium-depleted potassium depolarizing solution. Ten minutes after, 1.8 mM $CaCl_2$ was added to muscle bath and elicited a biphasic increase in muscle tension. Cyclobuxine E produced an appreciable inhibition of both components of the mechanical response. In addition, Cyclobuxine E introduced at a point when the tonic response had reached its maximum level, caused the muscle to exhibit a rapid loss of tension. Based on these experimental results, we proposed the possibility that the inhibitory action of cyclobuxine E on the isolated rat duodenum may be due to inhibiting the transmembrane fluxes of calcium ion in potassium-activated calcium channels.

  • PDF

Quality Characteristics of Korean Chive (Allium tuberosum Rotter) as affected by Inner Film Packaging Methods in Paper Box (부추의 종이박스 내 속포장에 따른 품질 특성)

  • Jang, Min Sun;Lee, Jung-Soo;Chandra, Dulal;Choi, Jee Won;Lee, Jin-Su;Park, Me Hea;Choi, Hyun Jinn;Hong, Yuun Pyo;Kim, Ji Gang
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.3
    • /
    • pp.143-150
    • /
    • 2017
  • Effects of packaging methods for maintaining the shelf-life and postharvest quality of Korean chive (Allium tuberosum Rotter) usually called buchu in Korea was studied during fall season. Buchu, which has high moisture content and active metabolism after harvest, is characterized by the greater changes in quality during storage and distribution. It is usually packaged in paper box during distribution in domestic channel in Korea where the marketability ends within few days of harvest. In order to maintain the commercial quality of buchu, we tried to use inner film with or without absorbent paper in commercial paper box packaging. The 'Greenbelt' cultivar of buchu was harvested in october and packaged in corrugated paper box (A), in corrugated paper box with micro-perforated high density polyethylene (HDPE) film as inner material (B), a layer of absorbent paper both at the bottom and top of buchu in corrugated paper box (C) and a combination of HDPE film as inner material along with a layer of absorbent paper both at the bottom and top of buchu in corrugated paper box (D), and stored at $5^{\circ}C$ for up to 21 days. Several quality parameters such as fresh weight loss, respiration rate, color, chlorophyll content and sensory qualities were monitored during storage. When buchu was packaged only in paper box, the appearance and quality deteriorated rapidly through decay development thereby sample became unmarketable within 12 days. On the other hand, buchu packaged with inner HDPE film maintained its quality, good visual appearance and exhibited a longer period of marketable life compared to the samples stored in other treatments. However, the use of absorbent paper did not have any significant effect in maintaining quality of buchu. The uses of inner HDPE film was effective in reducing weight loss that resulted better visual appearance of buchu. Results suggest that the use of inner HDPE film in bulk type corrugated paper box packaging and storing at $5^{\circ}C$ could be the optimum condition for commercial storage of buchu. Further investigation on other quality parameters and packaging methods would be useful in maintaining the quality aspects of buchu at postharvest stages.

Comparison of Forcep-biopsy and Cryo-biopsy by a Flexible Bronchoscopy (굴곡성 기관지경을 통한 겸자 생검술과 냉동 생검술의 비교)

  • Kim, Jae Hyun;Choi, Jung Min;Song, Sung Eun;Lee, Eun Mi;Lee, Song Ju;Oak, Chul Ho;Jang, Tae Won;Jung, Man Hong;Jang, Hee Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.2
    • /
    • pp.110-115
    • /
    • 2009
  • Background: A forceps-biopsy is performed to acquire tissue from patients with an endobronchial carcinoma using a flexible bronchoscope. Recently, a cryo-biopsy has also been used to acquire tissue samples. Cryo-biopsy is the diagnostic application of extreme cold for the local destruction of abnormal living tissue. This technique is safe, with no radiation danger, no risk of electrical accidents, and a little risk of bleeding. This study compared a forceps-biopsy with a cryo-biopsy using a flexible bronchoscope, and examined the chemosensitivity and level of VEGF (vascular endothelial growth factor) in the specimens obtained from the cryo-biopsy. Methods: We present a prospective study of 30 consecutive patients who underwent a forceps-biopsy between January 2007 and October 2007 with a mean age of 62.1 years and a male:female ratio of 5 : 1. A flexible bronchoscope was inserted to the area of the abnormal lesions, and a cryo-probe was then applied through the working channel of the flexible bronchoscope. A temperature of approximately -h80 was delivered to the tumor site for 8 seconds. The cryo-biopsy was performed after destroying the tumor mass. Results: The mean size of the tissue from the forceps-biopsy and cryo-biopsy were 2.0${\pm}$1.2 mm and 6.0${\pm}$3.0 mm. A chemosensitivity test was performed on 5 specimens obtained using cryo-biopsy and the level of VEGF was examined in 2 specimens obtained from a cryo-biopsy. There were no side effects in either group. Conclusion: Cryo-biopsy using a flexible bronchoscope is a safe and effective technique for acquiring tissue samples.