• Title/Summary/Keyword: $I_c$ degradation

Search Result 397, Processing Time 0.022 seconds

Development of a New-type Apparatus Decomposing Volatile Organic Compounds using a Combination System of an Electrical Exothermic SiC Honeycomb and a Catalytic Filter

  • Nishikawa, Harumitsu;Takahara, Yasumitsu;Takagi, Osamu;Tsuneyoshi, Koji;Kato, Katsuyoshi;Ihara, Tadayoshi;Wakai, Kazunori
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • A new-type apparatus decomposing volatile organic compounds (VOCs) using a combination system of an electrical exothermic SiC honeycomb and a catalytic filter was developed. This linear combination system is very useful to the catalytic decomposition of VOCs, because the gas involving VOCs is well heated in the SiC honeycomb and then flows into the catalytic filter. In the proposed apparatus, the outlet gas temperatures of SiC honeycomb maintained at ca. $300^{\circ}C$ after 5 min from the starting of applying electric current, and sufficient for the catalytic degradation of VOC components, i.e. toluene, isopropanol, methyl ethyl ketone and ethyl acetate. The average decomposition rate of total VOCs exhausted from a printing factory was 85% using pt catalyst at SV=19,000 in this system.

Isolation, Regeneration and PEG-Induced Fusion of Protoplasts of Pleurotus pul-monarius and Pleurotus florida

  • Eyini, M.;Rajkumar, K.;Balaji, P.
    • Mycobiology
    • /
    • v.34 no.2
    • /
    • pp.73-78
    • /
    • 2006
  • Inter-specific hybridization between Pleurotus pulmonarius and P. florida was attempted through PEG-induced protoplast fusion to select a fusant. The protocol for protoplast release, regeneration and fusion in these two Pleurotus species was standardized using the variables controlling the process. The mixture of mycolytic enzymes, i.e. commercial cellulase, crude chitinase and pectinase, KCl (0.6 M) as osmotic stabilizer, pH 6 of the phosphate buffer and an incubation time of 3 hours resulted in the maximum release of protoplasts from 3-day-old mycelia of P. florida ($5.3{\sim}5.75{\times}10^{7}$ protoplasts/g) and P. pulmonarius ($5.6{\sim}6{\times}10^{7}$ protoplasts/g). The isolated protoplasts of P. florida regenerated mycelium with 3.3% regeneration efficiency while P. pulmonarius showed 4.1% efficiency of regeneration. Polyethyleneglycol (PEG)-induced fusion of protoplasts of these two species resulted in 0.28% fusion frequency. The fusant produced fruiting bodies on paddy straw but required a lower temperature of crop running ($24{\pm}2^{\circ}C$) than its parents which could fruit at $28{\pm}2^{\circ}C$. The stable fusant strain was selected by testing for the selected biochemical markers i.e. Carbendazim tolerance and utilization of the lignin degradation product, vanillin.

Photocatalytic Degradation of Gaseous Acetaldehyde through TiO2-Coated Fly Ash Composites (TiO2 코팅 석탄회 복합체의 기상 Acetaldehyde 광분해 특성)

  • Shin, Dae-Yong;Kim, Kyung-Nam
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.1
    • /
    • pp.43-47
    • /
    • 2008
  • The photocatalyst of $TiO_2$ coated on a fly ash composites (TCF) was prepared from precipitant dropping method to remove the acetaldehyde by photocatalytic reaction. The TCF were characterized by crystal aize, crystal structure and specific surface area. The photodegradation of acetaldehyde has been investigated using a UV-illuminated fixed photocatalytic reactor with TCF catalyst and P-25 catalyst in gas phase. The effect of photodegradation reaction conditions, such as initial concentration of acetaldehyde, concentration of oxidant in mixed gas and the light intensity on the photodegradation of acetaldehyde were investigated. P-25 catalyst showed the highest photodegradation of acetaldehyde and anatase $TiO_2$ coated TCF showed higher decomposition rate than rutile coated TCF. The photodegradation rate of acetaldehyde increased with the decrease of flow rate, initial concentration of acetaldehyde ($C_i$) and water vapor, however, it was increased with the increas of UV light intensity. The optimum conditions were weight of TCF=10 g, flow rate=50 ml/min $C_i$=100 ppm, concentration of oxygen=20%, concentration of water vapor=100 ppm.

Performance evaluation of differently structured RCE-DR GdBCO coated conductor tapes under uniaxial tension at 77 K

  • Diaz, Mark Angelo E.;Shin, Hyung-Seop;Jung, Ho-Sang;Lee, Jaehun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.13-17
    • /
    • 2022
  • The mechanical properties of REBCO coated conductor (CC) tapes under uniaxial tension are mainly determined by the thick layer Components like the substrate and the stabilizer. Depending on the applications of the CC tapes, it is also needed to externally reinforce thin metallic foils to one side or both sides of the CC tapes. This study investigated the effect of additional stabilizer layers or lamination on the electrical resistivity and electromechanical properties in RCE-DR processed GdBCO CC tapes with different structures. The strain/stress tolerance of Ic in differently processed 12 mm-wide REBCO CC tapes under uniaxial tension at 77 K and self-field could be determined by the loading-unloading scheme. As a result, Sn-Cu stabilized CC tape showed a significant decrease in mechanical properties due to its soft but thick stabilizing layer. However, similar electromechanical properties have been observed on both Sn-Cu and Sn-stabilized CC tapes, the Ic degradation behavior was independent of whether the CC tape has an external reinforcement or different stabilizing layers.

EFFECT OF ANTE-MORTEM STRESS ON POST-MORTEM CHANGES OF TITIN I (α-CONNECTIN) INTO TITIN II (β-CONNECTIN) AND NEBULIN IN THE LIGHT AND DARK MUSCLE OF TAIWAN COUNTRY CHICKEN

  • Lin, L.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.3
    • /
    • pp.405-411
    • /
    • 1994
  • Purified myofibrils were prepared from ante-mortem stress and control lots of Taiwan country chicken breast and thigh muscles at death and afler storage at $4^{\circ}C$ for 0, 1, 2, 3, and 7 days post-mortem. Sodium dodecyl sulfate polycrylamide gel electrophoresis (3.2%) and densitometer were used to examine the effect of ante-mortem stress and control storage of muscle on titin and nebulin. Results indicated that titin and nebulin were more rapidly degraded in the control and the ante-mortem stress light muscles than in the control and ante-mortem dark muscles of Taiwan country chicken. In contrast, nebulin was shown to be more resistance to degradation in the ante-mortem stress dark muscle than in the control light muscle.

Pharmacokinetics and Tissue Distribution of DA-3030 (recombinant human granulocyte colony-stimulating factor) after Intravenous, Intramuscular or Subcutaneous Administrations to the Laboratory Animals. (DA-3030(recombinant human granulocyte colony-stimulating factor)의 정맥, 근육 또는 피하주사시 실험동물에서의 약물동력 학 및 조직 분포)

  • 이응두;심현주;이종진;이상득;강수형;김원배;양중익
    • Biomolecules & Therapeutics
    • /
    • v.2 no.4
    • /
    • pp.310-315
    • /
    • 1994
  • The pharmacokinetics and tissue distribution of DA-3030 (recombinant human granulocyte colony-stimulating factor, rhG-CSF, recently manufactured by Dong-A research laboratory of Dong-A Pharmaceutical Company) were compared with reported data in the literature. After intravenous(i.v.) administration of DA-3030, at dose of 5, 10 and 100 $\mu\textrm{g}$/kg to rats, some pharmacokinetic parameters, such as terminal half-lives(1.05, 1.19 and 1.83 hr, respectively) and clearance (84.0, 54.8 and 45.5 mι/hr/kg, repectively), were dose-dependent. This could be due to the saturable metabolism of DA-3030 in rats. Similar results were also reported. After subcutaneous(s.c.) and intramuscular(i.m.) administrations of DA-3030, 10 $\mu\textrm{g}$/kg to rats, the extent of bioavailability(absolute bioavailability) were incomplete; the values were 23.3 and 18.2% after s.c. and i.m. injections, respectively, due to the degradation of DA-3030 by protease. After 7-consecutive day i.v. administrations of DA-3030, 10 $\mu\textrm{g}$/kg/day, to rats, the plasma concentrations and pharmacokinetic parameters of DA-3030 were not significantly different from those in single administration. In mice and dogs at DA-3030 dose of 10 $\mu\textrm{g}$/kg, the plasma concentrations of DA-3030 were also declined rapidly with terminal half-lives of 1.31 and 1.15 hr, respectively. DA-3030 was highly concentrated in the kidney after i.v. administration of DA-3030, 10 $\mu\textrm{g}$/kg, to rats, and the results were similar to those obtained using radiolabelled rhG-CSF in the literature. Above data indicate that DA-3030 has similar properties to rhG-CSF manufactured by other companies in view of pharmacokinetics.

  • PDF

Fabrication of Thick SmBCO/IBAD-MgO coated conductor (후막 SmBCO/IBAD-MgO 초전도 박막선재의 제조)

  • Lee, J.H.;Kang, D.K.;Ha, H.S.;Ko, R.K.;Oh, S.S.;Kim, H.K.;Yang, J.S.;Jung, S.W.;Moon, S.H.;Youm, D.;Kim, C.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.9-9
    • /
    • 2009
  • Coated conductor is required to have good critical current property for high efficiency of electric power applications. Until now, long coated conductor does not show high Jc over 3 MA/$cm^2$ in thick superconducting layer because of texture degradation by thick superconducting layer. In this study, in order to overcome this issue, thicker superconducting layer was deposited with optimized conditions to reduce the degradation of critical current density. SmBCO superconducting coated conductor was deposited with 1~3 um of thickness at $750\sim850^{\circ}C$ under 15~20 mTorr of oxygen partial pressure using batch type EDDC( evaporation using drum in dual chamber). The buffered substrate for superconducting layer deposition was used IBAD-MgO template with the architecture of $LaMnO_3/MgO/Y_2O_3/Al_2O_3$/Hastelloy. After fabrication of coated conductor, critical current was measured by 4-prove method under self-magnetic field and 77K. In addition, surface morphology and texture were analyzed by SEM and XRD, respectively. 3 um thick SmBCO coated conductor shows highest $I_C$ values of 638A/cm-w in 1 m long in the world.

  • PDF

Application of EN(Electrochemical Noise) to Evaluate the Protective Properties of Epoxy Coated Steels (EN(Electrochemical Noise)을 이용한 epoxy 도장 강판의 방청 성능 평가)

  • Han, Jong-Man
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.203-207
    • /
    • 2009
  • Electrochemical methods have been widely used to study the performances and mechanisms for the degradation of organic and inorganic coatings. In this study, EN(Electrochemical noise) measurement was applied to the protective properties and review the parameters analyzed noise signals in the time and in the frequency domain for epoxy resin based coated steels during exposure to hot sea water($40^{\circ}C$) and salt spray for 200 days. It was also found that $R_n$(Noise resistance), $R_{sn}$($f_{min}$)(Spectral noise resistance) and 2H(Hurst exponent) represented the performance of epoxy coated steels. $R_n$ can be determined as the ratio of the standard deviations of potential and current noise signals and is decreased to exposure time. Data qualities can be easily checked by PSD(Power Spectral Density) plot and $V_{psd}$, $I_{psd}$ and $R_{sn}$($f_{min}$) is useful to research the protective performances and mechanisms of coated steels. Hurst exponent represents the degradation of coated steels. But, it is difficult to directly apply the protective criterion to the evaluation of epoxy coated steels used the shipbuilding processes.

Reconsideration of Classical Antibiotic Lincomycin: Anti-inflammatory Effect in LPS-stimulated RAW 264.7 Cells

  • Yang, Eun-Jin;Lee, Nari;Hyun, Chang-Gu
    • Microbiology and Biotechnology Letters
    • /
    • v.48 no.3
    • /
    • pp.366-372
    • /
    • 2020
  • Since, side effects of antibiotics are frequently emphasized these days, their use is gradually diminishing, and alternative drugs are being developed. We have sought to reintroduce them as raw materials for human health as conventional 'weapons' that have been retired after their historical duties. In this study, we investigated the anti-inflammatory effects of lincomycin (LIN), on lipopolysaccharide (LPS)-stimulated RAW 264.7 cells. Our findings show that LIN potently inhibited production of LPS-induced proinflammatory mediators, such as nitric oxide (NO) and prostaglandin E2 (PGE2), without cytotoxicity. Consistent with these findings, LIN strongly decreased protein expression levels of inducible NO synthase (iNOS) and cyclooxygenase (COX-2). Furthermore, LIN reduced pro-inflammatory cytokines such as tumor necrosis factor (TNF)-α, interleukin (IL)-6, and IL-1β. To further elucidate the mechanisms of these inhibitory effects of LIN, we studied LPS-induced IκB-α degradation, and mitogen-activated protein kinase (MAPK) phosphorylation. LIN suppressed downregulation of inhibitory κB (IκB-α) degradation, and the phosphorylation of the c-Jun N-terminal kinase (JNK) pathway. Based on these results, we suggest that LIN may be considered a potential candidate as an anti-inflammatory cosmetic or a medicine for human health.

Piezoelectric property of PZT ceramics by DC field and corona discharge poling (직류전계 및 corona방전에 따른 PZT 세라믹스의 분극과 압전특성)

  • Park, In-Cheol;Im, Jin-Ho;Lee, Jun-Hyeong;Jo, Sang-Hui
    • Korean Journal of Materials Research
    • /
    • v.5 no.2
    • /
    • pp.178-183
    • /
    • 1995
  • Piezoelectric properties of sintered specimen having a tetragonal phase of $Pb_{0.9888}Sr_{0.012}(Zr_{0.52}Ti_{0.48})O_{3}$ were comparatively studied with two different poling methodes, i.e., DC field and corona discharge technique. Internal stress of poled specimens by indentation fracture toughness was analyzed to evaluate degradation phenomenon. As the results, it was confirmed that corona discharge poling technique is practicable and has merits such as low-temperature poling, slow degradation and no electric breakdown comparing to DC field poling. However, corona discharge technique showed lower Kp value than DC field poling.

  • PDF