• 제목/요약/키워드: $Hg^{2+}$ ion

검색결과 191건 처리시간 0.03초

세포막 물질수송계의 조절에 의한 유기수은의 세포독성 변화에 대한 연구 (Changes on the Methylmercury-induced Cytotoxicity by Control of Cell Membrane Transport System)

  • 염정호;고대하;김준연;김남송
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.88-96
    • /
    • 2000
  • The aim of the current study was to evaluate the transport system in EMT-6 cell for the uptake of the methylmercury(MeHg). Several inhibitors ere used to test used to test which potential transport system might be involoved in MeHg uptake. Probenecid was used to test the organic transport system, valinomycin for testing the effect of the membrane potential, cytochalasin B for testing the facilitated diffusive D-glucose transport system and colchicine for testing the microtubule system. Ouabain for evaluating active transport system, 4',4-diisothiocyano-2',2-stilbenedisulfonic acid(DIDS) the Cl- ion transport system and verapamil for the $Ca^{2+}$ transprot system. Significantly, MeHg decreased the synthesis of nitric oxcide(NO) and intracellular ATP in ENT-6 cells. In the condition of ouabain containing with MeHg decreased the production of NO and intracelluar ATP. In the treatment of inhibitors, ouabain showed protective effect against cytotoxicity of MeHg but ather inhibitors not showed protective effects. The protective effects of ouabain against the cytotoxicity of MeHg deoended on the concentration of added ouabain to the culture medium for MET-6 cells. These result showed that the uptake of MeHg might be involved in the active transport system. Active transports system seems to share similarities with the transport systems for the uptake of MeHg when using MeHg and MeHg-glutathione complex.x.

  • PDF

X선 영상 검출기 적용을 위한 $HgI_2$ 필름의 누설전류 특성 향상에 관한 연구

  • 권철;최치원;손대웅;조성호;강상식;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.345-345
    • /
    • 2007
  • 본 연구는 x선 영상검출기 적용을 위한 $HgI_2$ 필름의 누설전류 특성 향상을 위한 연구로서, $HgI_2$기반의 다양한 물질을 이용하여 다층구조 방식으로 제작된 필름의 누설전류 특성평가 및 제작된 다층구조의 상부전극물질의 변화에 따른 누설전류 특성을 평가하였다. $HgI_2$기반 다층구조의 제작 물질은 Parylene, $PbI_2$, a-Se을 사용하여 시편(parylene/ITO, ITO/$HgI_2/PbI_2$/ITO, ITO/$HgI_2$/a-Se/ITO)을 제작하였으며, 필름 제작공정은 Screen print, PVD공정으로 다층구조 필름을 제작하였다. 또 한, 다층구조로 제작된 필름에 상부 전극물질은 Au, In, ITO를 사용하여 누설전류의 특성을 평가하였다. 측정 장치로 DC Power Supply(556H. EG&G : 50~200V), X 선 발생장치(Toshiba KXO-50N), 차폐체 (Al 및 Cu), Oscilloscope (LeCroy, LC334AM, USA), Electrometer (Keithley, 6517), Ion chamber 2060 (Radical Co.)을 이용하여, 제작된 $HgI_2$기반 다층구조 sample의 누설전류 특성을 실험하였다. 이 결과로 다층구조에 제작된 물질 및 상부전극에 따른 누설전류의 특성을 평가하였다.

  • PDF

CdTe/CdHgTe 코어쉘 나노입자를 이용한 P채널 전계효과박막트렌지스터의 전기적특성 (Electrical characteristics of Field Effect Thin Film Transistors with p-channels of CdTe/CdHgTe Core-Shell Nanocrystals)

  • 김동원;조경아;김현석;김상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1341-1342
    • /
    • 2006
  • Electrical characteristics of field-effect thin film transistors (TFTs) with p-channels of CdTe/CdHgTe core-shell nanocrystals are investigated in this paper. For the fabrication of bottom- and top-gate TFTs, CdTe/CrHgTe nanocrystals synthesized by colloidal method are first dispersed on oxidized p+ Si substrates by spin-coating, the dispersed nanoparticles are sintered at $150^{\circ}C$ to form the channels for the TFTs, and $Al_{2}O_{3}$ layers are deposited on the channels. A representative bottom-gate field-effect TFT with a bottom-gate $SiO_2$ layer exhibits a mobility of $0.21cm^2$/ Vs and an Ion/Ioff ratio of $1.5{\times}10^2$ and a representative top-gate field-effect TFT with a top-gate $Al_{2}O_{3}$ layer provides a field-effect mobility of $0.026cm^2$/ Vs and an Ion/Ioff ratio of $2.5{\times}10^2$. $Al_{2}O_{3}$ was deposited for passivation of CdTe/CdHgTe core-shell nanocrystal layer, resulting in enhanced hole mobility, Ior/Ioff ratio by 0.25, $3{\times}10^3$, respectively. The CdTe/CdHgTe nanocrystal-based TFTs with bottom- and top gate geometries are compared in this paper.

  • PDF

Adsorption isotherm and kinetics analysis of hexavalent chromium and mercury on mustard oil cake

  • Reddy, T. Vishnuvardhan;Chauhan, Sachin;Chakraborty, Saswati
    • Environmental Engineering Research
    • /
    • 제22권1호
    • /
    • pp.95-107
    • /
    • 2017
  • Adsorption equilibrium and kinetic behavior of two toxic heavy metals hexavalent chromium [Cr(VI)] and mercury [Hg(II)] on mustard oil cake (MOC) was studied. Isotherm of total chromium was of concave type (S1 type) suggesting cooperative adsorption. Total chromium adsorption followed BET isotherm model. Isotherm of Hg(II) was of L3 type with monolayer followed by multilayer formation due to blockage of pores of MOC at lower concentration of Hg(II). Combined BET-Langmuir and BET-Freundlich models were appropriate to predict Hg(II) adsorption data on MOC. Boyd's model confirmed that external mass transfer was rate limiting step for both total chromium and Hg(II) adsorptions with average diffusivity of $1.09{\times}10^{-16}$ and $0.97m^2/sec$, respectively. Desorption was more than 60% with Hg(II), but poor with chromium. The optimum pH for adsorptions of total chromium and Hg(II) were 2-3 and 5, respectively. At strong acidic pH, Cr(VI) was adsorbed by ion exchange mechanism and after adsorption reduced to Cr(III) and remained on MOC surface. Hg(II) removal was achieved by complexation of $HgCl_2$ with deprotonated amine ($-NH_2$) and carboxyl (COO-) groups of MOC.

Phosphorescent Azacrown Ether-appended Iridium (III) Complex for the Selective Detection of Hg2+ in Aqueous Acetonitrile

  • Li, Yinan;Yoon, Ung-Chan;Hyun, Myung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.122-126
    • /
    • 2011
  • A new phosphorescent cyclometalated heteroleptic iridium (III) complex with an ancillary ligand of 4-azacrownpicolinate was prepared and its metal ion selective phosphorescent chemosensing behavior was investigated. The new iridium (III) complex exhibits notable phosphorescence quenching for Hg2+ in aqueous 50% acetonitrile solution with respect to the selective phosphorescent detection of various metal ions including $Li^+,Na^+,K^+,Cs^+,Mg^{2+},Ca^{2+},Ba^{2+},Fe^{2+},Ni^{2+},Cu^{2+},Zn^{2+},Ag^+,Pb^{2+},Cd^{2+},Cr^{2+},Cr^{3+}$ and $Hg^{2+}$. The phosphorescence quenching for $Hg^{2+}$ increased linearly with increasing concentration of $Hg^{2+}$ in the range of $10{\mu}M-700{\mu}M$ even in the presence of other metal ions, except for $Cu^{2+}$. Consequently, the new iridium (III) complex has the potential to be utilized for the determination of parts per million levels of $Hg^{2+}$ in aqueous acetonitrile media.

골격근 小胞體의 ATPase活性에 미치는 二價金屬이온의 영향 (Kinetic Studies on the Effects of Divalent Cations on the ATPase Activity of the Fragmented Sarcoplasmic Reticulum of Rabbit Skeletal Muscle)

  • Park, Young-Soon;Ha, Doo-Bong
    • 한국동물학회지
    • /
    • 제23권3호
    • /
    • pp.137-148
    • /
    • 1980
  • 토끼 골격근 小胞體의 ATPase 活性에 미치는 $Hg^{2+}, Cu^{2+}, Pb^{2+}, Cd^{2+}, Mn^{2+}$ 등 2價 陽이온을 영향을 비교 측정하였다. 이들 陽이온은 $Mn^{2+}$을 제외하고 모두 이 酵素의 活性을 阻害하였다. $Mn^{2+}$은 低濃度 (12.5-100 $\mu$M)에서는 오히여 活性을 증가시켰고, 그 보다 高濃度에서는 극히 약하게 阻害하였다. $Mn^{2+}$을 제외한 위의 2價 陽이온들의 阻害龍은 $Hg^2$가 가장 컸고 (阻害係數 Ki = 10$\mu$M), rm 다음이 $Cu^{2+}$ (Ki = 30$\mu$M), $Pb^{2+}$ (Ki = 120$\mu$M), $Cd^{2+}$ (Ki = 320$\mu$M)의 순이었다. 위의 4종의 陽이온들의 ATPase에 대한 阻害作用을 可逆的 非競爭的 阻害로 판정되었다.

  • PDF

Biosorption of Hg(II) ions from synthetic wastewater using a novel biocarbon technology

  • Singanan, Malairajan
    • Environmental Engineering Research
    • /
    • 제20권1호
    • /
    • pp.33-39
    • /
    • 2015
  • Mercury is a toxic pollutants present in different types of industrial effluents and is responsible for environmental pollution. Removal of Hg(II) ions from synthetic wastewater was studied using the activated biocarbon produced from the leaves of Tridax procumbens (Asteraceae). The particle size of the biocarbon (BC) is in the range of $100-120{\mu}m$. The effects of initial metal ion concentration, pH, contact time, and amount of biocarbon on the biosorption process were studied at temperature of $28{\pm}2^{\circ}C$. Batch experimental studies showed that an equilibrium time of 160 min was required for the maximum removal of Hg(II) at the optimized biocarbon dose of 2.5 g per 100 mL of synthetic wastewater. The optimum pH required for maximum removal (96.5%) of Hg(II) ions was found to be 5.5. The biosorption of metal ions onto activated biocarbon surface is probably via an ion exchange mechanism. The biocarbon can be regenerated with minimum loss. Further, it can be reused without any chemical activation. The findings of the research suggested that, the biocarbon produced from cost effective renewable resources can be utilized for the treatment of industrial wastewater.

수질환경에서 광섬유 센서의 구리 이온 감지 물질로서 8-Hydroxyquinoline 합성유도체의 광학적 반응 특성 연구 (Study on Optical Characteristics of 8-Hydroxyquinoline Synthesized Derivative as Sensing Material of the Fiber-Optic Copper Ion Sensor in Aqueous Environment)

  • 김범규;박병기
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.100-105
    • /
    • 2017
  • 수질환경에서 구리이온을 검출하기 위하여 광섬유 센서의 구리 이온 감지 물질로 8-Hydroxyquinolin-2carboxaldehyde와 4-Aminoantipyrine으로 합성된 8-Hydroxyquinoline 합성유도체에 대해 광학적 반응 특성을 조사하였다. 실험은 광섬유를 이용한 측정시스템을 이용하여 수용액에 용해된 구리 이온의 농도에 대해 합성유도체에 의한 흡광도와 관계를 평가하기 위하여 수행되었다. 8-Hydroxyquinoline 합성유도체는 수질 환경에서 다양한 금속 이온들 중에서 구리 이온에 대해 노란색에서 붉은색으로 변화되는 높은 발색 현상을 나타냈으며 530 nm의 고유 흡광 파장을 보였다. 제작된 합성유도체의 Cu 이온에 대한 선택성을 평가하기 위하여 Hg 이온의 영향을 조사하였다. Cu와 Hg 이온의 다양한 농도 비 (Cu:Hg ratio 0.05부터 20까지)에서 흡광도를 측정한 결과, Cu 이온의 농도 증가에 따라 530nm에서 흡광도가 증가하는 경향을 보였다. 구리 이온의 고유 흡광 파장인 530 nm에서 합성 유도체에 의한 흡광도 세기는 구리 이온의 로그 농도에 선형으로 비례하였다. 따라서 8-Hydroxyquinoline합성유도체는 광섬유 센서의 구리 이온 감지 물질로 우수한 특성을 보임을 실험적으로 확인할 수 있었다.

Voltammetric Assay of Mercury Ion in Fish Kidneys

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • 제24권1호
    • /
    • pp.23-28
    • /
    • 2008
  • Voltammetric analysis of mercury ions was developed using paste electrodes (PEs) with DNA and carbon nanotube mixed electrodes. The optimized analytical results of the cyclic voltammetry (CV) of the $1{\sim}14ng\;L^{-1}Hg(II)$ concentration and the square wave (SW) stripping voltammetry of the $1{\sim}12ng\;L^{-1}Hg(II)$ working range within an accumulation time of 400 seconds were obtained in 0.1 M $NH_4H_2PO_4$ electrolyte solutions of pH 4.0. For the relative standard deviations of the $1ng\;L^{-1}Hg(II)$, which were observed at 0.078% (n = 15) at the optimum conditions, the low detection limit (S/N) was pegged at $0.2ng\;L^{-1}(7.37{\times}10^{-13}M)$ for Hg(II). The results can be applied to assays in biological fish kidneys and wastewater samples.