• Title/Summary/Keyword: $H_2S$ removal

Search Result 779, Processing Time 0.027 seconds

Removal of Soluble Fe(II) using Reactive Media Coated with both Fe and Mn (철과 망간이 동시에 코팅된 반응성 매질을 이용한 용존 Fe(II) 제거)

  • Min, Sang-Yoon;Chang, Yoon-Young;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.85-92
    • /
    • 2011
  • Evaluation of the removal efficiencies of Fe(II) by reactive sand media coated with manganese (MCS), iron (ICS) and both of iron and manganese (IMCS) was investigated as functions of solution pH ranging from 2 to 9, reaction time and concentration of Fe(II) in a batch reactor using each reactive medium and additional oxidants such as $KMnO_4$ and NaOCl. When only Fe(II) was present in solution without any reactive medium, removal of Fe(II) was quite low below pH 5 due to a slow oxidation of Fe(II) and/or negligible precipitation but greatly increased above pH 5 due to a rapid oxidation of Fe(II) and subsequent precipitation of oxidized Fe species. ICS showed negligible efficiency on the removal of Fe(II) through adsorption. However, an efficient removal of Fe(II) was observed at low solution pH in the presence of IMCS or MCS through rapid oxidation and subsequent precipitation. Removal efficiency of Fe(II) by IMCS in the presence or absence of NaOCl was quite similar. Removal rate of Fe(II) by IMCS and additional oxidants gradually increased as the solution pH increased. From the kinetic experiments, removal pattern of Fe(II) was better described by pseudo-second-order equation than pseudo-first-order equation. A rapid removal of Fe(II) using IMCS in the presence of $KMnO_4$ was observed in the first 10 min. The initial removal rate of Fe(II) using $KMnO_4$ was 14,286 mg/kg hr. In case of using NaOCl, the removal of Fe(II) occurred rapidly in the first 6 hrs and then reached the near-equilibrium state. Removal of Fe(II) on IMCS was well expressed by Langmuir isotherm and the maximum removal capacity of Fe(II) was calculated as 1,088 mg/kg.

High Temperature Desulfurization over ZnO-Fe2O3 Mixed Metal Oxide Sorbent (ZnO-Fe2O3 복합금속 산화물을 이용한 고온에서의 황화수소 제거에 관한 연구)

  • Lee, Jae-Bok;Lee, Young-Soo;Yoo, Kyong-Ok
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.1
    • /
    • pp.62-67
    • /
    • 1994
  • Introduction : Recently, water and environmental pollution becomes serious social problem and high technology makes this pollution accelerate. Hydrogen sulfide, the main subject of our research, is one of the most dangerous air pollutant like SO$_x$ and NO$_x$. The major contaminant in coal gasification is H$_2$S, which is very toxic, hazardous and extremely corrosive. Therefore, control of hydrogen sulfide to a safe level is essential. Although commercial desulfurization process called liquid scrubbing is effective for removal of H$_2$S, it has drawbacks, the loss of sensible heat of the gas and costly wastewater treatment. Many investigations are carried out about high-temperature removal ol H$_2$S in hot coal-derived gas using metal oxide or mixed metal qxide sorbents. It was reported that ZnO was very effective sorbent for H2S removal, but it has big flaw to vaporize elemental zinc above 600\ulcorner \ulcorner As alternative, metal oxides such as CaO, $Fe_2O_3$, TiO$_2$ and CuO were added to ZnO. Especially, different results are reported for $Fe_2O_3$ additive. Tamhankar et al. reported SiO$_2$ with 45 wt% $Fe_2O_3$ sorbent is favorable for removal of H$_2$S and regeneration.

  • PDF

Characteristics of Hydrogen Sulfide Removal by a Catalyst-assisted Plasma System (촉매-플라즈마 반응 시스템을 이용한 황화수소의 처리특성 연구)

  • Lee, Jeong-Keun;Kim, Hyeok-Gyu;Bong, Choon-Keun;Park, Seong-Jin;Lee, Myong-Hwa;Hwang, Ui-Hyun;Kim, Jong-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.4
    • /
    • pp.379-386
    • /
    • 2011
  • Catalyst-assisted plasma system with a DBD (Dielectric Barrier Discharge) reactor was used to remove hydrogen sulfide, which is one of the odorous species in this study. The ${\gamma}-Al_2O_3$ and ${\beta}$-Zeolite catalysts impregnated by Ag, Cu and Mn species were employed as catalysts and their $H_2S$ removal characteristics under plasma irradiation were investigated. From the experimental study, we found that the $H_2S$ removal efficiency increases with decreasing space velocity in the system and increasing specific input energy. Furthermore, ${\beta}$-Zeolite catalysts are efficient to remove $H_2S$ than ${\gamma}-Al_2O_3$ catalysts. Especially, the catalysts impregnated by Ag have higher removal efficiency than other catalysts (Cu, Mn).

Removal of Mixed Gases of H2S and NH3 by the Biofilter Packed with Biomedia (Biomedia를 충전한 Biofilter에서 H2S와 NH3 혼합악취의 제거)

  • Lim, Joung Soo;Cho, Wook Sang;Lee, Eun Young
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.165-170
    • /
    • 2006
  • When ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) in binary mixture gases were supplied to a biofilter packed with biomedia made of polyurethane, PVA, and worm cast. No odor gases were detected on the outlet of the biofilter when $NH_3$ and $H_2S$ were separately supplied to the biofilter at space velocity(SV) of $50h^{-1}$ until inlet $NH_3$ concentration was increased up to 300 ppmv and inlet $H_2S$ to 428 ppmv. While, inlet $NH_3$ concentration maintained at 50 ppmv, inlet $H_2S$ concentration increased from 1 to 489 ppmv, and the removal efficiency of each gas was investigated. After that, $NH_3$ concentration increased step by step such as 80, 100, 200, 300, 400 and 500 ppmv. $H_2S$ concentration increased gradually when $NH_3$ concentration was set up at each condition. Under each condition, removal efficiency of $NH_3$ and $H_2S$ gas was investigated by analysing the gases sampled from the inlet and outlet of the biofilter. When binary gases were supplied to the biofilter and inlet $NH_3$ concentration was increased from 50 to 300 ppmv, elimination capacity of $NH_3$ increase linearly as inlet loading increased to $11.14g\;N{\cdot}m^{-3}{\cdot}h^{-1}$. However, as inlet $NH_3$ concentration increased over 300 ppmv, both removal efficiency and elimination capacity decreased while inlet loading increased. $H_2S$ removal efficiency was not affected seriously by the simultaneous supply of $NH_3$ when maximum inlet loading of $H_2S$ was under $40.27S{\cdot}m^{-3}{\cdot}h^{-1}$ and maximum inlet loading of $NH_3$ was under $15.25N{\cdot}m^{-3}{\cdot}h^{-1}$.

  • PDF

Degradation of toxic azo dye (AO7) using Fenton's process

  • Sharma, Ashish;Verma, Manisha;Haritash, A.K.
    • Advances in environmental research
    • /
    • v.5 no.3
    • /
    • pp.189-200
    • /
    • 2016
  • This study aimed at advanced oxidation of hetero tri-functional reactive dye Acid orange 7 using photo-Fenton conditions in a lab-scale experiment. Decolourisation of Acid Orange 7 dye by Fenton's process was dependent on concentration of Hydrogen peroxide, Ferrous sulphate, pH, and contact time. A $2^3$ factorial design was used to evaluate the effects of these key factors: pH, Fe(II), and $H_2O_2$ concentration, for a dye concentration of 50 mg/L with COD of 340 mg/L at pH 3.0. The response function was removal of colour under optimised conditions; pH 3.0, [Fe(II)] 40.83 mg/L, [$H_2O_2$] 4.97 mmol/L; 13.6 min. of treatment resulting in 100% colour removal. The final COD of treated wastewater was nil suggesting that AOP is a potentially useful process of color removal and dye degradation/mineralisation of effluent having AO7. Minimum contact time for complete decolourisation was at 5 mmol/l $H_2O_2$ concentration. Increase in $FeSO_4$ (mg/l) concentration resulted in decrease of time for complete decolourisation. Box-Behnken Design was used to optimize the process variables. Maximum and minimum levels of pH (3-5), $H_2O_2$ (4-6 mmol/l), $FeSO_4$ (30-46 mg/l) and contact time (5-15 minutes) were used. The statistical analysis revealed a value of 0.88 for coefficient of regression ($R^2$) indicating a good fit of model. Calculated F-value was found higher than the tabulated value confirming to significance of the model. Based on student's t-test, Ferrous sulphate, pH, and contact time have a positive effect on the percent decolourisation of Acid Orange 7.

Cholesterol Removal from Lard with Crosslinked ${\beta}$-Cyclodextrin

  • Kim, S.H.;Kim, H.Y.;Kwak, H.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.9
    • /
    • pp.1468-1472
    • /
    • 2007
  • The present study was carried out to determine the optimum conditions of different factors (ratio of lard to water, ${\beta}$-CD concentrations, mixing temperature, mixing time and mixing speed) on cholesterol reduction from lard by using crosslinked ${\beta}$-CD. Crosslinked ${\beta}$-CD was prepared with adipic acid. When the lard was treated under different conditions, the range of cholesterol removal was 91.2 to 93.0% with 5% crosslinked ${\beta}$-CD, which was not significantly different among treatments. In a recycling study, cholesterol removal with crosslinked ${\beta}$-CD in the first trial was 92.1%, which was similar to that with new crosslinked ${\beta}$-CD. In up to eight time trials, over 90% of cholesterol removal was found. The present study indicated that the optimum conditions for cholesterol removal using crosslinked ${\beta}$-CD were a 1:3 ratio of lard to water, 5% crosslinked ${\beta}$-CD concentration, $40^{\circ}C$ mixing temperature, 1 h mixing time and 150 rpm mixing speed. In addition, crosslinked ${\beta}$-CD made by adipic acid resulted in an effective recycling efficiency.

Sexual Behaviors, Estrus Detection and Conception of Heifers Synchronized by Progesterone Intravaginal Device(Prid) and Synchromate-B

  • Im, K.S.;Kim, C.K.;Voss, H.J.;Allen, S.;Zheng, X.;Foote, R.H.
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.2
    • /
    • pp.140-147
    • /
    • 1985
  • Seventy four Holstein heifers were randomly assigned over three trials to PRID-7+PG-6 and Synchromate B-9 regimens to synchronize estrus cycle for embryo transfer. Sexual behaviors; moounting, standing, orientation, chin-resting, sniffing, licking, rubbing and butting, vaginal swelling and mucus discharge were observed between 06-08, 12-14 and 18-20 h on 1st day and 00-02, 06-08, 12-14 and 18-20 h on 2nd day after removal of hormones. Synchromate-B treatment (81.6%) showed higher synchronized estrus rate than PRID treatment (77.8%) during observation period. Standing estrus was observed within 74 h after PG injection in PRID and within 52 h after removal of implant in Synchromate-B. About 68% of heifers in PRID and 74% of heifers in Synchromate-B showed standing estrus between 0-14 h on 2nd day after removal of the hormones. Synchromate-B resulted in a tighter synchrony of standing estrus than PRID. Incidence of average mounting and standing per head during observation period was 22.3 and 16.6 in PRID and 28.1 and 13.6 in Synchromate-B. The PRID showed peak in active mounting at 18-20 h on 1st day, however, the Synchromate-B showed at 0-2 h on 2nd day after removal of hormone. Active standing was shown between 18 h on 1st day to 20h on 2nd day in PRID, however, between 0-14 h on 2nd day after removal of hormone is Synchromate-B. There was slight difference in pattern of active mounting and standing during estrus between PRID and Synchromate-B. Conception rate of synchronized heifers transferred with fresh and frozen embryos by non-surgical and surgical methods was higher in synchromate-B (62.5%) than in PRID (38.5%). Chin-resting showed highest incidence among 6 sexual behavioral components in the both treatments. Synchromate-B showed higher incidence of chin-resting (16.6) than PRID (10.7). Synchromate-B group showed also higher incidence of orientation, sniffing and butting than PRID group. Synchromate-B resulted in more active sexual behaviors than PRID. The pattern of incidence of chin-resting, licking and butting was almost symmetrical in PRID with their peak values at 6-8 h on 2nd day, however in Synchromate-B chin-resting and sniffing was symmetrical with their peak values at 12-14 h on 2nd day after removal of hormone. There was tendency to increase vaginal swelling according to time passage of synchronized estrus in the both treatments. Incidence of mucus discharge in Synchromate-B was slightly higher than in PRID. Twenty to 40% was false negative in conception rate by tall painting before re-estrus day as judged by rectal palpation.

  • PDF

Evaluation of Effective Process Operation for the Texitile Dyeing Wastewater by Ferrous Solution and Hydrogen Peroxide

  • Lee, Sang Ho;Moon, Hey Jin
    • Journal of Environmental Science International
    • /
    • v.13 no.11
    • /
    • pp.987-991
    • /
    • 2004
  • The purpose of this research is to evaluate the removal efficiencies of COD$\_$Cr/ and color for the dyeing wastewater by the different dosages of ferrous solution and H$_2$O$_2$ in Fenton process. In the case of H$_2$O$_2$ divided dosage for the Fenton's reagent 7:3 of H$_2$O$_2$ was more effective than 3:7 to remove COD$\_$Cr/ and color. The results showed that COD$\_$Cr/ was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand color was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of COD$\_$Cr/ and color was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However, the final removal efficiency of COD$\_$Cr/ and color was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

EFFECT OF INLET LOADING RATE ON THE ELIMINATION OF HYDROGEN SULFIDE AND AMMONIA IN IMMOBILIZED CELL BIOFILTERS

  • Kim, Jung-Hoon;Rene, Eldon R.;Park, Seung-Han;Park, Hung-Suck
    • Environmental Engineering Research
    • /
    • v.11 no.5
    • /
    • pp.285-291
    • /
    • 2006
  • Biofiltration is a simple, effective, economically viable and the most widely used gas treatment technique for treating malodors at low concentrations and high flow rates. This paper reports the performance of two lab scale immobilized cell biofilters operated in continuous mode for hydrogen sulfide ($H_2S$) and ammonia ($NH_3$) removal. The removal efficiency (RE, %) and the elimination capacity (EC, $g/m^3{\cdot}hr$) profiles were monitored by subjecting the biofilters to different loading rates of $H_2S$ (0.3 to $8\;g/m^3{\cdot}hr$) and $NH_3$ (0.3 to $4.5\;g/m^3{\cdot}hr$). The removal efficiencies were greater than 99% when inlet loading rate to the biofilters were upto $6\;gH_2S/m^3{\cdot}hr$ and $4\;gNH_3/m^3{\cdot}hr$ respectively. The performance of the biofilters were also ascertained by conducting shock loading studies at a loading rate of $10\;gH_2S/m^3{\cdot}hr$ and $6\;gNH_3/m^3{\cdot}hr$. The results from this study show high removal efficiency, good recuperating potential and stability of the immobilized microbial consortia to transient shock loads.

Biofiltration of Odorous Compounds in Municipal Solid Waste Landfill Gases (생물탈취상에 의한 도시폐기물 매립지가스내 악취물질의 처리)

  • 남궁완;박준석;황의영;이노섭;인병훈;김정대
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • Biofiltration is an attractive technique for elimination of VOCs and odorous compounds from low-concentration, high-volume waste gas streams because of its simplicity and cost-effectiveness. The objective of this study was to estimate the removal characteristics of Odorous Compounds including $H_2$S, $NH_3$End BTEX in MSW landfill gases. This Study was conducted at Nanjido landfill site. A compost from the Nanjido composting facility was used as a filling material for biofiltration. Extracted landfill gases were injected into biofilter reactors after mixing with air. Experiments were performed in an incubator being set to $20^{\circ}C$ $H_2$S concentrations were monitored at the depths of 25, 50, 75 and 100cm from the bottom Of the biofilter reactors. 98% of $H_2$S was removed at the filling depth of only 25cm. NH$_3$removal rate was about 85%. Toluene removal rate was the highest among BTEX. Significant pH drop of a filling material was not observed during the biofilter operation of 1 month. Without mixing the landfill gas stream with all, the removal rate of $H_2$S decreased down to 30%.

  • PDF