• Title/Summary/Keyword: $H^1$-공간

Search Result 790, Processing Time 0.027 seconds

Application of Biofilter for the Removal of VOCs Produced in the Remediation of Oil-Contaminated Soil (유류오염 토양의 복원과정에서 발생되는 휘발성 유기화합물의 제거를 위한 바이오필터의 적용)

  • Lee Eun Young;Choi Woo-Zin;Choi Jin-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2005
  • This research was investigated the applicability of the biofiltration technology for the removal of volatile organic carbons (VOCs) produced from the bioremediation of oil contaminated soil. Diesel was used as surrogate for oil and, two types of biofilter systems made of ceramic and polymer media were compared for the removal efficiencies of diesel VOCs at different inlet concentrations and space velocity (SV) conditions. During the first 30-d operation, the removal efficiencies of the biofilter packed with polymer and the biofilter packed with ceramic were investigated at constant SV of $153\;h^{-1}$ When inlet concentrations of diesel VOCs were below 10 ppmv, the average removal efficiencies of the polymer biofilter and the ceramic biofilter were average $67\%\;and\;75\%$, respectively. When the inlet concentration increased to 30 ppmv, the VOC removal efficiency in the polymer biofilter was $80\%$, while the average removal efficiency in the ceramic biofilter was $60\%. Effect of the inlet concentration and SV on the removal efficiency of total diesel VOCs was investigated. As SV increased from $153\;h^{-1}$ to $204\;h^{-1}$ and $306\;h^{-1}$, the removal efficiency of total diesel VOCs was decreased gradually. The average removal efficiency of the biofilter packed with polymer carrier was decreased from $82\%\;to\;80\%\;and\;77\%$. The biofilter packed with polymer carrier showed that the removal efficiency of benzene and toluene were maintained within the range of $81\%\~86\%$. In contrast, for the biofilter packed with ceramic carrier, when SV increased from $153\;h^{-1}$ to $204\;h^{-1}$ and $306\;h^{-1}$, the removal efficiency of benzene decreased from $87\%\;to79\%\;and\;74\% . respectively. The removal efficiency of toluene decreased from $80\%\;to\;77\%\;and\;76\%$ at SV of $153\;h^{-1},\;204\;h^{-1}\;and\;306\;h^{-1}$, and $306\;h^{-1}$, respectively.

Bonding and Antibonding Regions (II). Origin of Barriers to Internal Rotation of $H_2O_2$ and $C_2H_6$ (결합공간과 반결합공간 (제2보). $H_2O_2$$C_2H_6$의 Internal Rotation Barrier의 원천적 요인)

  • Kim Hojing;Lee Duckhwan
    • Journal of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.20-29
    • /
    • 1979
  • The origin of barriers to internal rotation of hydrogen peroxide and ethane is investigated by using the concept of Bonding and Antibonding Regions. The strong bond formations between the axial and end atoms on the same side make the real charge densities in these molecules less dependent on conformations than those in the hypothetical molecules having no axial atoms. Thus, the existence of the axial atoms should induce the migration of the transition density from the Bonding region to the Antibonding region. Barrier to internal rotation can be understood in terms of this migration of the transition density to such an extent that the change in nuclear-nuclear repulsion energy becomes the dominating part of the total perturbation energy.

  • PDF

FIELD RR LYRAE 변광성의 특성: 공간분포 및 증원소함량 분포

  • Jeon, Yeong-Beom;Lee, Si-U
    • Publications of The Korean Astronomical Society
    • /
    • v.7 no.1
    • /
    • pp.207-229
    • /
    • 1992
  • 우리 은하계내 field RR Lyrae 변광성의 관측자료(GCVS 4th ed. )의 특성과 이들의 공간분포 및 증원소함량 분포를 조사하였다 이들의 공간분포에서 scale height 가 H = 0.6 kpc 인 원반(thick)형과 H = 2.2 kpc 인 헬로형의 두 성분으로 나타난다. 그리고 증원소함량의 은하중심거리와 은하정면거리에 따른 변화율은 각각 d[Fe/H]/dr = $-0.013\;{\sim}\;-0.020\;/kpc$ ($r\;{\le}\;20\;kpc$), d[Fe/H]/d|Z| = -0.034 /kpc ($|Z|\;{\le}\;10\;kpc$) 이다. 이러한 공간분포와 증원소함량의 기울기 변화는 구상성단의 경우와 비슷하게 이증진화모형을 나타낸다. 그러나 증원소함랑의 빈도분포로 보아 field RR Lyrae 변광성이 모두 구상성단에서 기원되었다고 보기는 어렵다.

  • PDF

The Changes in the Quality of Life Measure of the Seoul Metropolitan Area (수도권 삶의 질 지수 변동에 관한 연구)

  • Lee, Se-Hyung;Chang, Hoon;Rho, Jin-A
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2011
  • The purpose of this research is to measure Quality of Life indices using Factor Analysis and Principle Component Analysis and to analyze the spatial patterns of Quality of life distribution in the Seoul Metropolitan Area in terms of spatial association using spatial statistics and spatial exploratory technique. In order to check the degree of clustering, this study used spatial autocorrelation indices, global Moran's I index. In addition, local scale analysis was conducted using Moran Scatterplot and Local Moran's I to identify the spatial association pattern and the high Quality of life. The analysis based on global statics showed that, in the Seoul Metropolitan Area, QoL Indices had been distributed with positive spatial association. According to the local spatial statistics, the general tendency of clustering H-H clusters which were mainly concentrated on the Seoul, L-H clusters were concentrated on the Kyunggi-Do and L-L Clusters showed the regional extent of lagging behind. However, in case of H-H, L-H Clusters they had been spread out in the Newtown as population increase.

Bonding and Antibonding Regions (I) (결합공간과 반결합공간 (제1보))

  • Kim Hojing;Lee Duckhwan
    • Journal of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.15-19
    • /
    • 1979
  • The new concept of the Bonding and Antibonding Regions in the transition density space is developed from the Integral Hellmann-Feynman Theorem and the positive definiteness of the transition density. The unility of this concept is fully demonstrated for H2 system. It is expected that the nature of the electronic perturbation energy due to the change of nuclear configuration can be successfully understood by using this concept. Properties of the transition density is briefly discussed.

  • PDF

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

H.264/SVC Spatial Scalability Coding based Terrestrial Multi-channel Hybrid HD Broadcasting Service Framework and Performance Analysis on H.264/SVC (H.264/SVC 공간 계위 부호화 기반 지상파 다채널 하이브리드 고화질 방송 서비스 프레임워크 및 H.264/SVC 부호화 성능 평가)

  • Kim, Dae-Eun;Lee, Bum-Shik;Kim, Mun-Churl;Kim, Byung-Sun;Hahm, Sang-Jin;Lee, Keun-Sik
    • Journal of Broadcast Engineering
    • /
    • v.17 no.4
    • /
    • pp.640-658
    • /
    • 2012
  • One of the existing terrestrial multi-channel DTV service frameworks, called KoreaView, provides four programs, composed of MPEG-2 based one HD video and H.264/AVC based three SD videos within one single 6MHz frequency bandwidth. However the additional 3 SD videos can not provide enough quality due to its reduced spatial resolution and low target bitrates. In this paper, we propose a framework, which is called a terrestrial multi-channel high quality hybrid DTV service, to overcome such a weakness of KoreaView services. In the proposed framework, the three additional SD videos are encoded based on an H.264/SVC Spatial Base layer, which is compliant with H.264/AVC, and are delivered via broadcasting networks. On the other hand, and the corresponding three additional HD videos are encoded based on an H.264/SVC Spatial Enhancement layer, which are transmitted over broadband networks such as Internet, thus allowing the three additional videos for users with better quality of experience. In order to verify the effectiveness of the proposed framework, various experimental results are provided for real video contents being used for DTV services. First, the experimental results show that, when the SD sequences are encoded by the H.264/SVC Spatial Base layer at a target bitrate of 1.5Mbps, the resulting PSNR values are ranged from 34.5dB to 42.9dB, which is a sufficient level of service quality. Also it is noted that 690kbps-8,200kbps are needed for the HD test sequences when they are encoded in the H.264/SVC Spatial Enhancement layer at similar PSNR values for the same HD sequences encoded by MPEG-2 at a target bitrate of 12 Mbps.

Distribution of the Scatter Ray on Chest X-ray Examinations (흉부 X선 촬영 시 산란선 분포 연구)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.255-260
    • /
    • 2012
  • This study aims to examine the generation of scatter rays by dividing it into the presence of the subject at the chest X-ray examination, the X-ray tube and detector in the X-ray room, the front of the patient window, the outside of the entrance door of the patient waiting room, opening of the entrance door, the outside of the radiological technologist's entrance door, and the opening of the radiological technologist's entrance door, etc. When there is a subject, as the subject is thicker, more scatter rays occur at each of the spots for measurement. And when the entrance door is closed at the measurement, fewer scatter rays are generated.

Effect of the Space Dose Rate due to Change of X-ray Irradiation Energy and MU Value in Radiation Therapy Room (선형가속기의 엑스선 조사에너지와 MU값의 변화가 치료실 내 공간선량률 변화에 미치는 영향)

  • Kwon, Hyeonghyo;Park, Geonryul;Kim, Minji;Jo, Yeongdan;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.77-83
    • /
    • 2020
  • This study investigated the radiation protection of therapeutic radiologists. Based on the change in X-ray energy and MU value, the space dose rate in the treatment room after the irradiation was measured. 6MV, 10MV and 15MV photon beams were exposed to radiation inside the treatment room based on 300MU, 600MU and 1000MU using a linear accelerator. And repeated 10 times under the same conditions. As a result of the experiment, 0.1555 μSv/h for 6MV 300MU, 0.157 μSv /h for 300sec, 0.152 μSv/h, 0.156 μSv/h for 600MU, and 0.157 μSv/h 0.152 μSv/h for 1000MU. 300MU of 10MV was 0.49 μSv/h, 0.309 μSv/h, and 0.69 μSv/h, 0.416 μSv/h for 600MU, respectively, and 1000MU was 0.977 μSv/h and 0.478 μSv/h, respectively. The 300MU of 15MV was 3.02 μSv/h, 1.2 μSv/h, 5.459 μSv/h at 600MU, 7.34 μSv/h at 1.836 μSv/h 1000MU, and 2.709 μSv/h. The average spatial dose rate of 6MV was not significantly different from the natural spatial dose rate in the treatment room. High spatial dose rates were measured at 10 MV and 15 MV and were attenuated over time. Therefore, entering the treatment room after a certain period of time (more than 60 seconds) is considered to be effective to prevent the exposure dose of radiation workers.

Shape Extraction of Stiffeners of H-beam using Topologically Structural Optimization (위상최적설계를 이용한 H형강 부재의 스티프너 형상탐색)

  • Jung, Wonsik;Banh, Thien Thanh;Lee, Dongkyu
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.1
    • /
    • pp.15-23
    • /
    • 2023
  • In this work, we deal with the feasibility of structural topology optimization for beam designs using retrofits that optimally allocates the reinforcement to the web under the condition that designers set bolt regions for H-beams of different dimensions. Mean compliance or minimal strain energy is considered for the optimization. Volume fraction is given to the design space to assign appropriate steel material quantities. The purpose of this study is to evaluate optimal shapes of stiffeners with the maximum rigidity that improves the axial and shear performance of the H-beam and to satisfy a given safety design standard of H-beam and stiffeners in case arbitrary load effect and resistances. Finally, the effectiveness of stiffness-based topology optimization on stiffeners is verified with several practical applicable examples.