• Title/Summary/Keyword: $F_n$-Measure

Search Result 173, Processing Time 0.028 seconds

Study on the Improvement of Land Clearing Methods by Bulldozer & Fertilization of Cleared Soil (불도우저에 의한 개간 공법의 개선과 숙지화에 관한 연구)

  • Hwang, Eun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.1
    • /
    • pp.3627-3641
    • /
    • 1975
  • The Government is trying to increase total food grain yield to meet national self sufficiency by means of increasing unit yield as well as extending crop land, and this year he set the target of 321,000 hectare of forest to clear for cropping. This study was carried to investigate the most efficient method of clearing hillock by bulldozer, and successful method to develope yielding potential of newly cleared land in short term. Since the conventional land clearing method is just earth leveling and root removing neglecting top soil treatment, the growth of crop was poor and farmer tends not to care the land. The top-soil-furrowing method is applied through out this study, that is advantageous especially for the land having shallow top soil and low fertility like Korean forest. In this study, various operating method were tried to find out most efficient method separately in connection with the land slope less than 25 percent and over, and several fertilizing methods to develop yielding potential. The results are as follows; 1) For the natural land slope utilization method, applicable to the land having less than 25 percent slope, reverse operating was more efficient than using forward gear of bulldozer. The operating time was 3 hour 32 minutes and 36 seconds using forward gear was 2 hour 32 minutes and 30 seconds for reverse gear operation per 1,000 square meter. 2) Bulldozer having angle blade adjustment needed 7hr 15min. for constructing of terrace per 10a compaire with the one having angle & tilt adjustment needed 6hr 4min for same operations. Specially there is significant difference for operation time of first period (earth cutting) such as bulldozer having angle blade adjustment needed 3hr 56min compaired with the one having angle & tilt adjustment 3hr 59min. In construction of terrace, the bull-dozer having tilting and angle blade adjustment was most suitable and performed efficiently. 3) For the fertilizer application treatment, the grass (Ladino clover) yield in first year was almost same as ordinary field's in the plot applied(N.P.K+lime+manure) while none fertilizer plot showed one tenth of it, and (N.P.K.+lime) applied plot yielded on third. 4) The effect of different land clearing method to yield showed significant difference between each treatment especially in the first year, and the conventional method was the lowest. In the second year, still conventional terracing plot yielded only half of ordinary field while the other plots showed as same as ordinary field's. 5) The downward top soil treatment plot showed most rapid improvement in soil structure during one year physio chemically, it showed increase in pH rate and organic composition, and the soil changed gradually from loam to sand-loam and the moisture content increased against the pF rate, and it gives good condition to grow hay due to the increase of field water capacity with higher available water content. 6) Since the soil of tested area was granite, the rate of soil errosion was increased about 2 to 5 percent influencing in soil structure more sand reducing clay content, and an optimum contour farming method should be prepared as a counter measure of errosion.

  • PDF

A study of pain perception related to IV therapy in hospitalized preschool children and their mothers (정맥주사와 채혈시 학령전기 아동과 어머니가 인지하는 동통)

  • 임지영
    • Journal of Korean Academy of Nursing
    • /
    • v.22 no.1
    • /
    • pp.49-67
    • /
    • 1992
  • Most hospitalized children will experience physical pain as well as psychological distress. Preschool children's pain perception related to painful procedures can increase due to elevated anxiety and fear because they do not have understanding logical of their disease and hospitalization. In particular, they are distressed about needle - related procedures which are feared because they are seen to be a cause of bodily damage. This descriptive study attempted to identify pain perception levels in preschool children and their mothers. A self-reporting measurement and behavioral observation were used to collect the data. A total of 25 hospitalized preschool children and their mothers were investigated and data were collected about 60 painful procedures. Data collection was carried out by the researcher and two trained investigators from November first to December tenth. Three insruments were used to collect the data : Faces Pain Rating Scale(FPRS) developed by Beyer was used to measure the degree of preschool children's pain perception about painful procedures. The Visual Analogue Scale(VAS) devised by Huskisson was used to assess the degree of mothers' pain perception about their children's painful procedures. A Pain Behavioral Checklist based on the Procedure Behavior Check List by LeBaron and Zelter and modified by the researcher was used to observe behaviors of preschool children, their mothers, and nurses when the painful procedures took place. The data were analyzed by an SPSS program, and were tested using real numbers, percentages, Pearson correlation coefficient, t-test, and ANOVA. The results of this study are as follows : 1. Of all the painful procedures, the mean score for the FPRS for the preschool children's pain perception was 4.02 points, and the mean score for the VAS of mothers' pain perception was 10.92 points. 2. A Positive correlation which was statistically significant was found between the pain perception of preschool children and their mothers (r=.53, p<.01). that is, the higher the children's pain perception was, the higher their mothers' pain perception was. 3. The characteristics of the painful procedures related with children's pain perception as follows : The type of painful procedure was found to be statistically significant (F=23.44, p<.01), Among the three procedures Ⅳ starting was found to be perceived as the most painful procedures to the children. The greater the number of times that the procedure had been done, the higher the pain perception was (F=4.44, p<.01), and the longer the duration of the procedure, the higher the pain perception wa(r=.30, p<.05). Pain perception in the treatment room was higher than in the children's room(t=6.30, <.01), pain perception in the mother's presence was the higher than when the mother was not present (t=2.91, p<.01). 4. The characteristics of the painful procedures related with the mothers' pain perception as follows : The type of painful procedure was found to be statistically significant(F=6.01, p<.01). Among the three procedures Ⅳ sampling was found to be perceived as the most painful procedures to the mothers. The greater the number of times that the procedure had been done, the higher the pain perception was (F=5.95, p<.01), and the longer the duration of the procedure, the higher the pain perception was (r=.31, p<.05). Pain perception in the treatment room was higher than in the children's room (t=3.51, p<.01), but pain perception in the mother's presence showed statistically significant no difference. 5. Of all of the 19 children's behaviors during the painful procedures, the most frequent behaviors observed Were as follows in order of frequency “crying”, “screamirig”, “facial grimacing”, “physical resistance”, Of all of the nine methers' behaviors, the most frequent by observed in “console children”, “hold children”, “applaud children”, Of all of the 11 nurses' behaviors during the painful procedures, the mast frequent in order were “smiling”, “physical restraint”, “console children”, “praise children”. 6. A positive correlation between children's and mothers' pain perception and children's behaviors was found to be statistically significant (r=.65, p<.01, r=67, p<.01). Also the relationship between children's and mothers' pain percertion, and mothers' behavior was found to be statistically significant (r=.57, p<. 01, 4=.60, p<.01). The relationship between children's pain perception and nurses' behaviors was also found to be statistically significant (r=.46, p<.01), but there was difference between mothers' pain perception and nurses' behaviors.

  • PDF

Adherence-induced gene expression in human alveolar macrophages (표면부착에 의한 사람 폐포대식세포의 유전자 발현에 관한 연구)

  • Chung, Man Pyo;Yoo, Chul Gyu;Han, Sung Koo;Shim, Young-Soo;Rhee, Chong H.;Han, Yang Chol;Kim, Young Whan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.936-944
    • /
    • 1996
  • Background: Neutrophils or monocytes separated in vitro by the adherence to plastic surface are known to be activated by surface adherence itself and subsequent experimental data might be altered by surface adherence. Adhesion molecules and gene transcription of the inflammatory mediators are known to be associated in this process. To evaluate whether adhesion molecule and transcriptional activation of the inflammatory substances are also involved in the activation of human alveolar macrophage by the adherence procedure, we designed this experiment. Method : Bronchoalveolar lavage was performed in the person whose lung of either side was confirmed to be nonnal by chest cr and alveolar macrophage was harvested. To measure the expression of Interleukin-8(IL-8) mRNA, manganese superoxide dismutase(SOD) mRNA and CD11/CD18 mRNA in human alveolar macrophage of both adherence state and suspension state, Northern blot analysis was done at 0, 2, 4, 8 and 24hrs after the adherence to plastic surface and during suspension state. Then, phorbol myristate acetate(pMA) and N-formyl-methionyl-leucyl-phenylalanine(fMLP) were added respectively in the same experimental condition. Result : 1) Human alveolar macrophages in the adherent state induced IL-8 mRNA and SOD mRNA expression which was maximal at 8 hours after the adherence to plastic surface. But we could not observe the upregulation of CD18 mRNA by surface adherence. 2) PMA induced these mRNA expression both in the adherent cell and the nonadherem cells, but the induction of mRNA expression by fMLP occurred only in the adherent cells. Conclusion: These results suggest that adherence of huamn alveolar macropahge is an important cell-activating event that may play a critical role in the modulation of lung inflammatory respones.

  • PDF

Modeling of Estimating Soil Moisture, Evapotranspiration and Yield of Chinese Cabbages from Meteorological Data at Different Growth Stages (기상자료(氣象資料)에 의(依)한 배추 생육시기별(生育時期別) 토양수분(土壤水分), 증발산량(蒸發散量) 및 수량(收量)의 추정모형(推定模型))

  • Im, Jeong-Nam;Yoo, Soon-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.4
    • /
    • pp.386-408
    • /
    • 1988
  • A study was conducted to develop a model for estimating evapotranspiration and yield of Chinese cabbages from meteorological factors from 1981 to 1986 in Suweon, Korea. Lysimeters with water table maintained at 50cm depth were used to measure the potential evapotranspiration and the maximum evapotranspiration in situ. The actual evapotranspiration and the yield were measured in the field plots irrigated with different soil moisture regimes of -0.2, -0.5, and -1.0 bars, respectively. The soil water content throughout the profile was monitored by a neutron moisture depth gauge and the soil water potentials were measured using gypsum block and tensiometer. The fresh weight of Chinese cabbages at harvest was measured as yield. The data collected in situ were analyzed to obtain parameters related to modeling. The results were summarized as followings: 1. The 5-year mean of potential evapotranspiration (PET) gradually increased from 2.38 mm/day in early April to 3.98 mm/day in mid-June, and thereafter, decreased to 1.06 mm/day in mid-November. The estimated PET by Penman, Radiation or Blanney-Criddle methods were overestimated in comparison with the measured PET, while those by Pan-evaporation method were underestimated. The correlation between the estimated and the measured PET, however, showed high significance except for July and August by Blanney-Criddle method, which implied that the coefficients should be adjusted to the Korean conditions. 2. The meteorological factors which showed hgih correlation with the measured PET were temperature, vapour pressure deficit, sunshine hours, solar radiation and pan-evaporation. Several multiple regression equations using meteorological factors were formulated to estimate PET. The equation with pan-evaporation (Eo) was the simplest but highly accurate. PET = 0.712 + 0.705Eo 3. The crop coefficient of Chinese cabbages (Kc), the ratio of the maximum evapotranspiration (ETm) to PET, ranged from 0.5 to 0.7 at early growth stage and from 0.9 to 1.2 at mid and late growth stages. The regression equation with respect to the growth progress degree (G), ranging from 0.0 at transplanting day to 1.0 at the harvesting day, were: $$Kc=0.598+0.959G-0.501G^2$$ for spring cabbages $$Kc=0.402+1.887G-1.432G^2$$ for autumn cabbages 4. The soil factor (Kf), the ratio of the actual evapotranspiration to the maximum evapotranspiration, showed 1.0 when the available soil water fraction (f) was higher than a threshold value (fp) and decreased linearly with decreasing f below fp. The relationships were: Kf=1.0 for $$f{\geq}fp$$ Kf=a+bf for f$$I{\leq}Esm$$ Es = Esm for I > Esm 6. The model for estimating actual evapotranspiration (ETa) was based on the water balance neglecting capillary rise as: ETa=PET. Kc. Kf+Es 7. The model for estimating relative yield (Y/Ym) was selected among the regression equations with the measured ETa as: Y/Ym=a+bln(ETa) The coefficients and b were 0.07 and 0.73 for spring Chinese cabbages and 0.37 and 0.66 for autumn Chinese cabbages, respectively. 8. The estimated ETa and Y/Ym were compared with the measured values to verify the model established above. The estimated ETa showed disparities within 0.29mm/day for spring Chinese cabbages and 0.19mm/day for autumn Chinese cabbages. The average deviation of the estimated relative yield were 0.14 and 0.09, respectively. 9. The deviations between the estimated values by the model and the actual values obtained from three cropping field experiments after the completion of the model calibration were within reasonable confidence range. Therefore, this model was validated to be used in practical purpose.

  • PDF

Degree of Cognitive Conflict by Learner Personality and the Method of Presenting Anomalous Data in Science Learning (과학 학습에서 학습자 성격유형과 불일치 상황 제시 방법에 따른 인지갈등 정도)

  • Choi, Hyuk-Joon;Hong, Yun-Hee;Lee, Jae-Nam;Kwon, Mi-Rang;Seo, Sang-Oh;Kim, Ji-Na;Kim, Jun-Tae;Kwon, Jae-Sool
    • Journal of The Korean Association For Science Education
    • /
    • v.25 no.4
    • /
    • pp.441-449
    • /
    • 2005
  • The purpose of this study was to examine the degree of cognitive conflict by learner personality and the method of presenting anomalous data to induce cognitive conflict. The participants of this study were 461 high school students. To arose cognitive conflict, an actual demonstration was done for half of the participants and a logical article for the rest. MBTI (Myers-Briggs Type Indicator) was used to find the learner personality types, and CCLT (Cognitive Conflict Level Test) was used to measure the degree of cognitive conflict aroused when anomalous data was confronted. The results of this study indicated that learner personality types influence the degree of cognitive conflict. First, participants were divided into two personality types via preferences on each of the four preference indices; extraversion (E) or introversion (I), sensing (S) or intuition (N), thinking (T) or feeling (F), judgment (J) or perception (P). The cognitive conflict scores of the thinking types were significantly higher than those of the feeling types. Participants were also divided four personality types according to personality functional types: ST, SF, NT and NF. SF type showed a significantly lower cognitive conflict score than any of the other types. According to the type of learner personality, cognitive conflict was influenced differently by the method of presenting anomalous data. For example, the judgment types had a higher cognitive conflict score by logical argument, and the perception types showed a higher score by demonstration. In conclusion, learner cognitive conflicts were influenced by personality types and the methods of presenting anomalous data.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

A Comparative Study of the Effect of Two Analgesic Administration Methods on Post Operative Pain (수술환자에 었어서 마약성 진통제의 자가투여 방법과 근육주사 방법의 효과에 대한 비교연구)

  • 이정화
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.2
    • /
    • pp.401-410
    • /
    • 1997
  • An acute pain is the common experience following surgery. Pain is a most miserable experience in person and most preoperative patients have fear o! postoperative pain. In nursing, it is very important to understand and relieve the pain of post oprative patients as much as possible. This study was designed to compare the descriptive patterns of pain between group of Patient Controlled Analgesia and group of traditional Muscular Injection in surgcal patients. This information can be utilited as data of understanding nursing care and treatment planning for pain in surgical patients. The subjects in this study were 45 post-hysterectomy patients in Gynecology ward in C. N. U. H., in Taejon. Data was collected from May 12 to June 27. 1996. The instrumants used for this study were subjective Visual Analog Scale, Objedive nonverbal pain scale composed of Facial Apperance. Vocal Sound Change, and Sweating score. and the Melzack's Mcgill pain Qusetionaire. nine Items of Developmental Pain Intensity Scale by Lee En Ok. Analysis of data was done by using S. P. S. S. percentage, t-test, x²-test. ANOVA, and Repeated measure ANOVA. Results were obtained as follows. 1. Hypothesis 1 : There was very highly statistically significant difference in subjective self-report pain score(Visual Analog Scale) between PCA Group and IM Group(P=0.0001). 2. Hypothesis 2 : There was very highly statistically significant difference in muscle strength score (Visual Analog Scale) between PCA Group and IM group(P0.0001). 3. Hypothesis 3 : There was very highly statistically significant difference in facial appearance score between PCA Group and IM group(P=0.0001). 4. Hypothesis 4 : There was very highly statistically significance difference in vocal sound change score between PCA Group and IM group(P=0.0001). 5. Hypothesis 5 : There was no statistically significant difference sweating scores between PCA group and IM group(F=2.50, P=0.1220). But, postoperation time of 12, 24 was statistically difference between two groups(P=0.0001). So, it was partially supported. 6. Hypothesis 6 : There was very highly statistically significant difference in vocabulary pain score between PCA Group and IM group. 7. Hypothesis 7 : There was very highly statistically significant difference in amounts of total analgesic between PCA Group and IM group. There was very highly statistically significant difference in Visual Analog Pain Score, Facial Appearance Score, Vocal Sound Change Score, Vocabulary Score, amounts of total analgesic between PCA group and IM group. So, It is verified to asses of postoperative pain with VAS, Checklist of facia appearance, vocal sound change, and sweating, and Vocabulary Scale.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

A MEASUREMENT OF THE COSMIC MICROWAVE BACKGROUND B-MODE POLARIZATION WITH POLARBEAR

  • ADE, P.A.R.;AKIBA, Y.;ANTHONY, A.E.;ARNOLD, K.;ATLAS, M.;BARRON, D.;BOETTGER, D.;BORRILL, J.;CHAPMAN, S.;CHINONE, Y.;DOBBS, M.;ELLEFLOT, T.;ERRARD, J.;FABBIAN, G.;FENG, C.;FLANIGAN, D.;GILBERT, A.;GRAINGER, W.;HALVERSON, N.W.;HASEGAWA, M.;HATTORI, K.;HAZUMI, M.;HOLZAPFEL, W.L.;HORI, Y.;HOWARD, J.;HYLAND, P.;INOUE, Y.;JAEHNIG, G.C.;JAFFE, A.H.;KEATING, B.;KERMISH, Z.;KESKITALO, R.;KISNER, T.;JEUNE, M. LE;LEE, A.T.;LEITCH, E.M.;LINDER, E.;LUNGU, M.;MATSUDA, F.;MATSUMURA, T.;MENG, X.;MILLER, N.J.;MORII, H.;MOYERMAN, S.;MYERS, M.J.;NAVAROLI, M.;NISHINO, H.;ORLANDO, A.;PAAR, H.;PELOTON, J.;POLETTI, D.;QUEALY, E.;REBEIZ, G.
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.625-628
    • /
    • 2015
  • POLARBEAR is a ground-based experiment located in the Atacama desert of northern Chile. The experiment is designed to measure the Cosmic Microwave Background B-mode polarization at several arcminute resolution. The CMB B-mode polarization on degree angular scales is a unique signature of primordial gravitational waves from cosmic inflation and B-mode signal on sub-degree scales is induced by the gravitational lensing from large-scale structure. Science observations began in early 2012 with an array of 1.274 polarization sensitive antenna-couple Transition Edge Sensor (TES) bolometers at 150 GHz. We published the first CMB-only measurement of the B-mode polarization on sub-degree scales induced by gravitational lensing in December 2013 followed by the first measurement of the B-mode power spectrum on those scales in March 2014. In this proceedings, we review the physics of CMB B-modes and then describe the Polarbear experiment, observations, and recent results.