• Title/Summary/Keyword: $ETCO_2$

Search Result 15, Processing Time 0.033 seconds

Usefulness of End-tidal Carbon Dioxide as a Predictor of Emergency Intervention in Major Trauma Patients (중증 외상 환자에서의 응급중재술 시행 예측 인자로서의 호기말 이산화탄소 분압의 유용성)

  • Kim, Sung Ho;Kim, Seunghwan;Lee, Jae Gil;Chung, Sung Phil;Kim, Seung Ho
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.133-138
    • /
    • 2014
  • Purpose: If the survival of patients suffering from severe blunt trauma is to be improved, appropriate interventions should be taken immediately. The purpose of this study is to evaluate the clinical utility of end-tidal carbon dioxide ($ETCO_2$) as a surrogate marker for predicting both the need for intervention and the prognosis. Methods: This is a prospective observational study. Nasal cannula was applied to measure $ETCO_2$, and the following parameters, which are known to be related to the prognosis for a patient, were recorded: injury severity score (ISS), revised trauma score (RTS), arterial blood gas (ABG), lactate, and hemoglobin (Hb). To evaluate the outcome, we investigated the details of emergent interventions and expired patients. Results: A total of 93 patients were enrolled in this study. Emergent intervention was significantly associated with systolic blood pressure (sBP, p-value=0.001), $ETCO_2$ (p-value<0.001), serum lactate level (p-value<0.001), pH (p-value< 0.003), $HCO_3$ (p-value=0.004), base excess (p-value<0.002), ISS (p-value<0.001) and RTS (p-value=0.005). In the multivariate logistic regression, only $ETCO_2$ (odds ratio (OR): 0.897, 95% confidence interval (CI): 0.792-0.975, p-value= 0.048) and ISS (OR: 1.132, 95% CI: 1.053-1.233, p-value=0.002) were associated with emergent intervention whereas $ETCO_2$ (p-value=0.973) and ISS (p-value=0.511) were not statistically significant in predicting the survival of patients in the univariate analysis. An optimal ETCO cut-off of 29 mmHg on the ROC curve was determined, with the area under the ROC curve (AUC) being 0.824 (0.732-0.917)]. Conclusion: This study has revealed that $ETCO_2$, which can be rapid and easily measured through a nasal cannula, and the ISS may be prognostic indicators of emergent interventions in Emergency Departments.

Effect of ETCO2 monitoring of poisoning patients with decreased mental state in ED (의식 저하로 내원한 중독 환자들에 대한 호기말 이산화탄소분압 관찰의 효과)

  • Kwon, Yong Hee;So, Byung Hak;Jeong, Won Jung
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.1
    • /
    • pp.44-50
    • /
    • 2021
  • Purpose: This study aimed to analyse the effect of End-Tidal Carbon Dioxide (ETCO2) monitoring on patients who had been poisoned and presented in the emergency department with decreased consciousness. Methods: The data of patients over 18 years old presenting with poisoning from 2016 to 2020 was collected from the emergency department. We retrospectively analyzed their medical records, and defined patients with a Glasgow Coma Scale (GCS) score of 9 or less as having decreased consciousness. We divided the patients into two groups, one with ETCO2 monitoring and the other without, and the difference between the two groups was compared. Results: 168 patients participated in this study and 83 (49.4%) of them belonged to the ETCO2 monitoring group. In this group, the interval between arterial blood tests was statistically significantly longer and the rate of intubation was lower. In addition, in the monitoring group, the incidence of pneumonia and the rate of poor prognosis was not significantly higher. Conclusion: Although ETCO2 monitoring does not directly affect the prognosis of poisoned patients with decreased consciousness, it should be actively done as it can help to adequately treat patients while avoiding invasive techniques or unnecessary intubation.

Respiratory Responses during Exercise in Self-contained Breathing Apparatus among Firefighters and Nonfirefighters

  • Hostler, David;Pendergast, David R.
    • Safety and Health at Work
    • /
    • v.9 no.4
    • /
    • pp.468-472
    • /
    • 2018
  • Background: Firefighters are required to use self-contained breathing apparatus (SCBA), which impairs ventilatory mechanics. We hypothesized that firefighters have elevated arterial $CO_2$ when using SCBA. Methods: Firefighters and controls performed a maximal exercise test on a cycle ergometer and two graded exercise tests (GXTs) at 25%, 50%, and 70% of their maximal aerobic power, once with a SCBA facemask and once with protective clothing and full SCBA. Results: Respiratory rate increased more in controls than firefighters. Heart rate increased as a function of oxygen consumption ($V_{O_2}$) more in controls than firefighters. End-tidal $CO_2$ ($ETCO_2$) during the GXTs was not affected by work rate in either group for either condition but was higher in firefighters at all work rates in both GXTs. SCBA increased $ETCO_2$ in controls but not firefighters. Conclusions: The present study showed that when compared to controls, firefighters' hypoventilate during a maximal test and GXT. The hypoventilation resulted in increased $ETCO_2$, and presumably increased arterial $CO_2$, during exertion. It is proposed that firefighters have altered $CO_2$ sensitivity due to voluntary hypoventilation during training and work. Confirmation of low $CO_2$ sensitivity and the consequence of this on performance and long-term health remain to be determined.

Comparison of the effects of joint mobilization, gym ball exercises, and breathing exercises on breathing pattern disorders and joint position sense in persons with chronic low back pain

  • Lim, Chae-Gil
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.1
    • /
    • pp.25-35
    • /
    • 2020
  • Objective: To compare the effects of joint mobilization, gym ball exercises, and breathing exercises on breathing pattern disorders and joint position sense in persons with chronic lower back pain. Design: Three-group pretest-posttest design. Methods: Thirty-six individuals with chronic low back pain who were undergoing a postural correction and vertebral movement at a rehabilitation center participated in this study. The subjects were randomly divided into the joint mobilization group (n=12), gym ball exercises group (n=12), and the breathing exercises group (n=12). The exercises were applied for 40 minutes a day, twice a week for a total of 12 weeks. Measurement tools included the end-tidal CO2 (ETCO2), respiration rate (RR), breath hold time, Nijmegen Questionnaire (NQ), excursion, and joint position error (JPE). Results: The groups showed significant differences in the ETCO2, RR, NQ, Excursion and JPE test before and after the intervention (p<0.05). The differences between the groups were significant in the group that received the gym ball and breathing exercises in ETCO2 and RR (p<0.05). The differences between the groups were most significant in the group that received breathing exercises in NQ and excursion (p<0.05). The differences between the groups were significant in the group that received the gym ball and breathing exercises in JPE Lt. and Rt. (p<0.05). Conclusions: All three interventions had a significant impact on the biomechanical changes, respiratory variables, and joint position sense in participants with chronic lower back pain. Breathing exercises were found to be particularly effective in improving respiratory parameters.

Sevoflurane Sedation Using a Nasal Cannula in Pediatric Patients (소아환자에서 경비 캐눌라를 이용한 세보플루란 흡입 진정)

  • Ji, Sang-Eun;Kim, Jong-Soo;Kim, Jong-Bin;Kim, Seung-Oh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.194-200
    • /
    • 2013
  • A total of 14 children who visited the department of Pediatric dentistry of Dankook University Dental Hospital from January, 2012 to May, 2012 and decided to get dental treatment under inhalation sevoflurane deep sedation, were studied to determine the effectiveness of end-tidal sevoflurane, respiratory and cardiovascular function to analyze monitoring sheets. The Heart rate (H.R) data were mean 101.4 rate/min (76.4-135.4 rate/min). The systolic blood pressure data mean were 96.9 mmHg (84.2-109.2 mmHg) and diastolic blood pressure data mean were 50.5 mmHg (34.0-62.0 mmHg). The Respiration rate (R.R) data mean were 24.4 rate/min (15.0-36.7 rate/min). The $SpO_2$ data mean were 99.4% (97.5-100.0%). The end tidal $CO_2$ ($ETCO_2$) data mean were 27.8 mmHg (16.4-38.0 mmHg). The end-tidal sevoflurane data mean were 1.9 vol% (1.0-3.4 vol%).

Comparison of the anesthetic effects of 2,2,2-tribromoethanol on ICR mice derived from three different sources

  • Lee, Mi Ree;Suh, Hye Rin;Kim, Myeong Whan;Cho, Joon Young;Song, Hyun Keun;Jung, Young Suk;Hwang, Dae Youn;Kim, Kil Soo
    • Laboraroty Animal Research
    • /
    • v.34 no.4
    • /
    • pp.270-278
    • /
    • 2018
  • This study was conducted to compare the anesthetic effects of 2,2,2-tribromoethanol (TBE, $Avertin^{(R)}$) in ICR mice obtained from three different sources. TBE (2.5%) was intraperitoneally injected at three doses: high-dose group (500 mg/kg), intermediate-dose group (250 mg/kg), and low-dose group (125 mg/kg). Anesthesia time, recovery time, end-tidal peak $CO_2$ ($ETCO_2$), mean arterial blood pressure, heart rate, oxygen saturation ($SpO_2$), body temperature, pH, $PCO_2$, and $PO_2$ of the arterial blood were measured. Stable anesthesia was induced by all doses of TBE and the anesthesia time was maintained exhibited dose dependency. No significant differences in anesthetic duration were found among the three different strains. However, the anesthesia time was longer in female than in male mice, and the duration of anesthesia was significantly longer in female than in male mice in the high-dose group. The recovery time was significantly longer for female than male mice in the intermediate- and high-dose groups. In the ICR strains tested, there were no significant differences in the mean arterial blood pressure, $SPO_2$, arterial blood $PCO_2$, and $PO_2$, which decreased after TBE anesthesia, or in heart rate and $ETCO_2$, which increased after TBE anesthesia. In addition, body temperature, blood biochemical markers, and histopathological changes of the liver, kidney, and lung were not significantly changed by TBE anesthesia. These results suggested that ICR mice from different sources exhibited similar overall responses to a single exposure to TBE anesthesia. In conclusion, TBE is a useful drug that can induce similar anesthetic effects in three different strains of ICR mice.

Clinical assessment of the efficacy of supraglottic airway devices compared with endotracheal tubes in cats during volume-controlled ventilation

  • Niyatiwatchanchai, Nutawan;Thengchaisri, Naris
    • Journal of Veterinary Science
    • /
    • v.21 no.2
    • /
    • pp.27.1-27.10
    • /
    • 2020
  • The efficacies of a supraglottic airway device (SGAD) and an endotracheal tube (ETT) in cats under general anesthesia with volume-controlled ventilation (VCV) were compared. Thirty healthy cats were randomly allocated for airway control using either an SGAD or an ETT. Five tidal volumes (6, 8, 10, 12, and 14 mL/kg) were randomly tested, and respiratory rates were adjusted to achieve a minute ventilation of 100 mL/kg/min. The dose of propofol necessary to insert the SGAD or ETT, the static respiratory pressure, leakage during VCV, and end tidal CO2 (ETCO2) were recorded. Dosages of propofol and static respiratory measurements for the SGAD and ETT groups were compared using a t-test. The distribution of leakages and hypercapnia (ETCO2 > 45 mmHg) were compared using Fisher's exact test. A significance level of p < 0.05 was established. No significant difference in dose of propofol was observed between the SGAD and ETT groups (7.1 ± 1.0, 7.3 ± 1.7 mg/kg; p = 0.55). Static resistance pressure of the SGAD (22.0 ± 8.1 cmH2O/L/sec) was significantly lower than that of the ETT (36.6 ± 12.9 cmH2O/L/sec; p < 0.01). Of the 75 trials, leakage was more frequent when using an SGAD (8 events) than when using an ETT (1 event; p = 0.03). Hypercapnia occurred more frequently with SGAD (18 events) than with ETT (3 events; p < 0.01). Although intubation with an ETT is the gold standard in small animal anesthesia, the use of an SGAD can reduce airway resistance and the work of breathing. Nonetheless, SGAD had more dead space and the tidal volume for VCV needs adjustment.

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF

Intranasal administration of dexmedetomidine (DEX) as a premedication for pediatric patients undergoing general anesthesia for dental treatment

  • Lee, Yookyung;Kim, Jongsoo;Kim, Seungoh;Kim, Jongbin
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.1
    • /
    • pp.25-29
    • /
    • 2016
  • Background: The most important reason for pre-operative administration of medication is to reduce anxiety. Alleviation of fear and anxiety about surgery enables patients to remain comfortable during treatment. Dexmedetomidine (DEX) is a fast-acting drug that is used as a premedication in different circumstances because it has sedative and anti-anxiolytic effects, and stable hemodynamics. It also has the advantage of intranasal administration. The aim of this study was to investigate the effects and hemodynamic stability of DEX by retrospectively analyzing cases in which DEX was administered nasally as a premedication. Methods: Ten patients treated at Dankook University Dental Hospital, recruited between February and April 2015, received intranasal delivery of $2{\mu}g/kg$ DEX, 30 minutes prior to general anesthesia. Anesthesia records of anxiety, blood pressure, respiration, pulse, estimated arterial oxygen saturation ($SpO_2$), and partial pressure, or maximum concentration, of carbon dioxide ($ETCO_2$) were analyzed. Results: Administration of DEX prior to a general anesthetic effectively relieved anxiety. Respiratory depression, the most severe adverse effect of other sedatives, was not observed. Hemodynamic stability under general anesthesia was maintained during treatment and a reduction in emergence delirium was observed upon completion of treatment. Conclusions: Premedication administration of DEX is safe for pediatric patients undergoing dental treatment under general anesthesia.

The use of laryngeal mask airway in dental treatment during sevoflurane deep sedation

  • Lee, Sangeun;Kim, Jongsoo;Kim, Jongbin;Kim, Seungoh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.1
    • /
    • pp.49-53
    • /
    • 2016
  • Background: General anesthesia is frequently considered for pediatric patients, as they often find it difficult to cooperate and stay calm during administration of potentially painful treatments. Sedation can overcome these adversities; however, this is challenging while maintaining unobstructed airways. Methods: The study involved 11 pediatric dental patients treated with LMA under deep sedation with sevoflurane, from 2011 through 2015. LMA size, sevoflurane concentration, and the vital signs of patients were assessed through a chart review. Results: The age distribution of the patients ranged from 6 to 10 years old. A total of 3 patients underwent mesiodens extraction, while the remaining 8 underwent an surgically assisted orthodontic forced tooth eruption The average sedation period was approximately 45 minutes and the LMA size was $2\small{^1/_2}$. The sevoflurane concentration was maintained at 2% on average, and overall, the measurements of vital signs were within the normal range; the patients had an average blood pressure of 98/49 mmHg, breathing rate of 26 times/min, pulse frequency of 95 times/min, $SpO_2s$ level of 99 mmHg, and $ETCO_2$ level of 41.2 mmHg. Conclusions: Deep sedation with sevoflurane coupled with LMA may be applied successfully in pediatric patients who undergo mesiodens extraction or a surgically assisted orthodontic forced tooth eruption