• Title/Summary/Keyword: $Cr_2 O_3$

Search Result 1,270, Processing Time 0.024 seconds

Reversely Zoned Compositional Variations and their Origins of the Andong Pluton, Andong Batholith, Korea (안동심성암체의 역누대 초성변화와 그 성인)

  • 황상구;이보현
    • Economic and Environmental Geology
    • /
    • v.35 no.1
    • /
    • pp.75-95
    • /
    • 2002
  • The Andong pluton in the Andong Batholith is composed of comagmatic plutonic rocks, in which the lithofacies comprise hornblende biotite tonalite in the central paft biotite granodiorite in the marginal paft and porphyritic biotite granite at the topside (noJthea~tern paft) of the pluton. The pluton is petrographically and petrochemically zoned, having more mafic center than margin and topside. Distribution pallern of the lithofacies represents a reverse zoning in the pluton. Modal and chemical data in the pluton show progressive and gradual compositional variations from the centrer via the margin to the topside. Quartz and K-teldspar increase toward the topside of the pluton, whereas hornblende, biotite and color index increase toward the center. The bulk composition in the pluton is also reversely zoned, with high $Si0_2$ and $K_{2}O$ in the topside facies, and high MnO, CaO, $Ti0_2$, $Fe_{2}O_{3}$t, MgO and $P_{2}O_{5}$ in the central facies. The reverse zoning is also evident in higher Cr. V, Ni, Sc and Sr of the more mafic tonalite in the interior. The reversely zoned pluton results from remobilization (resurgence) of the lower more mafic compositional zone into the upper more felsic zones of the pluton modified by thennogravitational diffusion and fractional crystallization. In the initial stages of evolution, the pluton was a petrochemical system that fonned chemical compositional zonation with mafic tonalitic magma in the lower. granodioritic one in the middle and granitic one in the upper paft of the magma chamber. Periodic influxes of more mafic magma from the ba~e resulted in mingling of liquids and redistribution of minerals, and may have triggered the remobilil.ation of the lower compositional zone into the upper more felsic zones.

The Characteristics of Microbial Population Community Structure by an Addition of External Carbon Source in BNR Process for Low C/N Ratio Sewage Treatment (낮은 C/N비 하수의 외부 탄소원 주입에 따른 생물학적 질소제거에서 미생물 군집 구조특성)

  • Yoon, Cho-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.831-838
    • /
    • 2008
  • This study investigated the characteristics of nitrogen removal and microbial community in a lab-scale A$_2$O activated sludge process filled with the fluidized media at an aerebic basin. The change of microbial community was monitored based on quinone profiles of activated sludge according to feeding sewage with/without external carbon source. Low C/N ratio(COD$_{Cr}$/T-N of 1.24) sewage was fed. The obtained results from this study were as follows; Ubiquinone(UQ) in the influent was in the descending order of UQ-8, UQ-10 and UQ-9. Menaquinone(MK) was simpler and much less than UQ. The ratio of UQ/MK was less than 0.41 and the dissimilarity was below 0.26. Without an external carbon source, MK-8 was the dominant species and there were 3 kinds of quinone species and low DQ and EQ values in an anaerobic basin. The ratio of UQ/MK increased to 2.3 in an anoxic basin. In an oxic basin, UQ-7 and UQ-8 were the dominant species. UQ-7 was dominating in suspended microorganisms, while UQ-8 was in attached microorganisms. With an external carbon source addition, MK-8 decreased but UQ-8 increased in an anaerobic basin. So did quinone species, DQ and EQ values. There was also a change in an anoxic basin with the improvement of denitrification. UQ-8 decreased instead, MK-7 and MK-8 increased. UQ/MK ratio decreased 2.3 to 1.4. It means that the dominant species change from Pseudomonas sp. to Bacillus and Micrococcus species. etc. In an oxic basin, UQ-8 replaced UQ-7 in suspended microorganisms and UQ-10 replaced UQ-8 in attached microbials. This seemed related with the growth of Nitrosomonas and Nitrobactor species.

Ferromagnetism of thin films deposited from paramagnetic stainless steel targets by Facing Targets Sputtering

  • Matsushita, N.;Ono, N.;Naoe, M.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 1991.05a
    • /
    • pp.73-74
    • /
    • 1991
  • The films with ferromagnetic fine particles dispersed in nonmagnetic matrix, such as $Fe-Al_2O_3$ and Fe-Cu have been studied for use of magnetic recording medium, optically device and sensor. Their magnetic properties depend strongly on structural parameter such as size and volume fraction of ferromagnetic particles. Fe-Cr-Ni alloy sputtered films also have microstructure with ferromagnetic -- b.c.c phase and nonmagnetic f.c.c phase grains. Magnetic properties of these films depend strongly on such a unique structure. These are depend on the ratio in volume of ferromagnetic particles to nonmagnetic ones $V_F/V_N$, the saturation magnetization Ms increased with increase of $V_F/V_N$. The coercivity Hc of the as-deposited films took maximum value of about 200 Oe at adequate $V_F/V_N$ and then Ms and Squareness S were 500 emu/cc and 0.5, respectively.(omitted)

  • PDF

Investigation of Operating Parameters on UCT Process for the Purpose of Nitrogen Removal Using Computer Simulation (하수의 질소제거시 컴퓨터 시뮬레이션을 이용한 UCT(University of Cape Town) 공정의 운영인자 검토)

  • 김병군;서인석;이해군;김창원
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.66-75
    • /
    • 1998
  • The computer simulation model was used to forecast the concentrations of COD$_{cr}$, NH$_{4}$$^{+}$-N and NO$_{3}$$^{-}$-N in each reactors. In the biological wastewater treatment system, the computer simulation model was used to observe the behavior of pollutants especially. In this research, effect of SRT, feeding pattern and recirculation rate on UCT(University of Cape Town) process was evaluated by computer simulation model. T-N removal was affected to the SRT. SRT for effective T-N removal was 15 days or longer. Feeding pattern in UCT process was affected to the T-N removal. Feeding pattern which 100% loading to the first reactor was most effective for T-N removal. The effect of recirculation rate was clear for T-N removal. The recirculation from anoxic reactor to anaerobic reactor was not need but the recirculation from oxic reactor to anoxic reactor was need. In aspect of nitrogen removal efficiency, A/O process was higher than UCT process.

  • PDF

Chemically Induced Zigzag Migration in Alumina Bicrystals (알루미나 쌍결정에서 조성변화에 의한 Zigzag Migration)

  • 백용균;강석중
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.10
    • /
    • pp.1117-1122
    • /
    • 1995
  • The effect of grain boundary structure on zigzag migrtion has been studied. Five kinds of a(2110)-m(1010) diffusion couples with different twist angles by 30$^{\circ}$from a [0001] common direction of each plane were prepared. When chromia (Cr2O3) was added to the diffusion couples by a vapor phase, zigzag migration of the grain boundary occurred. The fraction of zigzag migration did not essentially vary with the twist angle, but the magnitude and migration distance of individual migrating segment varied. The variation of CIGM morphology thus appears to result from the change in grain boundary mobility due to microscopic deviation of grain boundary structure out of a macroscopic grain boundary orientation.

  • PDF

Astudy on the chromium plating from low concentrate bath (저농도 크롬도금에 관한 연구)

  • Lee, Kyung-Jin;Park, Kwang-Ja;Lee, Sung-Joo;Lee, Jong-Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.10 no.2
    • /
    • pp.1-18
    • /
    • 1977
  • In decorative chromium plating, highly concentrated conventionl baths ($CrO_3$ 150~400g/l) have been used. Because of the problems of heavy metal pollution and the saving of raw materials, chromium plating from dilute bath has been developed recently. The present study was performed to determine the effects of all the variables in the low concentrated chromium plating bath, such as brightness, appearence, current efficiency, and plating rate with regard to the bath composition and plating conditions.

  • PDF

Laser Engraving of Plasma Sprayed Ceramic Coatings (플라즈마 용사된 세라믹 코팅층의 레이저 홈가공)

  • Bang, Se Yoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.1
    • /
    • pp.142-149
    • /
    • 1997
  • Ceramic-coated anilox roll for printing is resistant to corrosion and wear, and hence has enhanced life and quality. Laser engraving is used typically for machining holes to store ink in this roll. Since engraved hole size and shape are directly related to laser processing parameters, it is necessary to know the rela- tionships among these parameters. In this study, the parameters for engraving of ;oasma sprayed ceramic coatings with Nd:YAG laser were studied. Relationships between hole shape and processing parameters were analyzed. Cr$_{2}$O$_{3}$ceramic was found to be most suitable for Nd:YAG laser engraving. It was found that hole depth can be increased by using higher energy pulses. Effect of using different assistant gases was small to the final results. For better results, it was suggested to use a very stable laser with shorter pulses and higher pulse energy.

  • PDF

First-principles study of the magnetic properties of the strontium hexaferrite $SrFe_{12}O_{19}$ (제일원리 계산을 이용한 스트론튬 페라이트의 자기적 특성 전산모사)

  • Yook, Young-Jin;Chung, Yong-Chae;Lee, Young-Jin;Im, Jong-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.201-201
    • /
    • 2006
  • 영구자석은 크게 Hard ferrite와 희토류계 자석, 그리고 Alnico 주조자석으로 구별되어진다. 그동안 Hard ferrite는 산업적으로 전자기 응용제품 또는 각종 구동 모터에 응용되어 왔지만, 최근 Nd계 희토류 자것이 고성능 모터의 소재로 급격히 대체되고 있다. 하지만, 희토류계 원료에 비해 동일 중량 대비 40~60배 가량 저렴한 Hard ferrite의 사용은 현재까지도 꾸준히 유지되고 있으며, 최근 자동차 고성능 모터용 Sr ferrite의 개발이 연구 중이다.[2] 본 연구에서는 제일원리 전산모사를 통하여 HCP 구조의 기본 Unit Cell 64개 원자를 가진 Sr-ferrite의 격자상수를 계산하여 기존 연구결과와 비교하였으며, 자화에너지와 자기모멘트를 계산하였다. 또한 향후 각종 첨가물의 영향에 대한 연구를 위해 기본 구조 및 치환 구조에 대해 고찰하였다. 그 결과 가장 안정한 에너지를 갖는 격자상수는 a=5.88, b=23.03으로 계산되어 Kimura et al의 측정 결과와 유사한 결과를 얻을 수 있었으며, $E_F$가 3.9171, $M_B$는 46.6481로 계산되었다. 항후 Sr-ferrite의 구조에서 Fe atom의 일부를 동일주기 원소인 Cr, Mn, Co, Ni, Cu로 치환하여 자기적 특성을 계산하여 본 연구결과와 비교하고자 한다.

  • PDF

Flows Characteristics of Developing Turbulent Pulsating Flows in a curved Square Duct (곡관덕트내의 입구영역에서 난류 맥동유도의 유동특성)

  • 봉태근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.533-542
    • /
    • 1999
  • In this study the flow characteristics of developing turbulent pulsating flows in a square-sec-tional 180。 curved duct are investigated experimentally. The experimental study of air flow in a square-sectional curved duct is carried out to measure axial velocity distribution secondary flow velocity profiles and wall shear stress distributions by using a Laser Doppler Velocimetry system with the data acquisition and processing system of Rotating Machinery Resolver (RMR) and PHASE software at the entrance region of the duct which is divided into 7 sections from the inlet(${{\o}}=0_{\circ}$) to the outlet (${{\o}}=180_{\circ}$) in $30_{\circ}$ intervals. The results obtained from the study are summarized as follows: (1) The time-averaged critical Dean number of turbulent pulsating flow(De ta, cr) is greater than $75{\omega}+$ It is understood that the critical Dean number and the critical Reynolds number are related to the dimensionless angular frequency in a curved duct. (2) Axial velocity profiles of turbulent pulsating flows are of an annular type similar to those of turbulent stead flows. (3) Secondary flows of trubulent pulsating flows are strong and complex at the entrance region. As velocity amplitudes(A1) become larger secondary flows become stronger. (4) Wall shear stress distributions of turbulent pulsating flows in a square-sectional $180_{\circ}$ curved duct are exposed variously in the outer wall and are stabilized in the inner wall without regard to the phase angle.

  • PDF

Sewage Treatment Using a Double Media Reed Constructed Wetland (복층여재 갈대 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.379-388
    • /
    • 2014
  • A sewage was treated using a serially combined vertical(VFCW) and horizontal flow double media (sand and zeolite for VFCW and sand and waste oyster-shell for HFCW) reed constructed wetland(HFCW) with intermittent feeding (see Fig. 1). The sewage was fed into the reed constructed wetland for 10 minutes every 6 hours at the hydraulic load of $314L/m^2{\cdot}day$. The summarized results were as follows: pH values in the effluent depended very heavily on oyster-shell height filled in the HFCW. They were maintained at less than pH 6.24 when the height of the oyster-shell layer was 200 mm. Influent DO(oxygen demand) values(average 0.19 mg/L) were increased in the VFCW(average 7.65 mg/L) and decreased again in the HFCW(average 6.49 mg/L). They were higher in the winter than in the summer. The OTR(oxygen transfer rate) was $57.15g\;O_2/m^2{\cdot}day$ in the VFCW and $5.65g\;O_2/m^2{\cdot}day$ in the HFCW. The removal efficiency of $NH_4{^+}$-N was 80.17%(6.01 $NH_4{^+}$-N mg/L in the effluent). It was lower than that in the case where only zeolite was filled in the reed constructed wetland. But it was expected that treated sewage effluent using a double media reed constructed wetland with 300 mm zeolite layer could stably meet the Korean treated sewage effluent standard(20 mg T-N/L). Average removal efficiencies were SS 88.09%, BOD 88.12%, $COD_{Cr}$ 83.11%, $COD_{Mn}$ 85.58%, T-N 57.21%, $NH_4{^+}$-N 80.17%, T-P 86.73%. Nearly, The concentration of $NO_3{^-}$-N in the effluent of the VFCW was decreased in that of the HFCW. More than half of T-N in the effluent was $NO_3{^-}$-N(7.92 mg/L) but the concentration of $NO_2{^-}$-N in the effluent was average 0.90 mg/L. The removal efficiencies of T-P were 93.24%, 86.30% and 55.44% at the height of the oyster-shell-filled constructed wetland of 800 mm, 500 mm and 200 mm, respectively and therefore, they were proportional to oyster-shell height filled in the HFCW.