• 제목/요약/키워드: $Cr(CO)_x$

검색결과 219건 처리시간 0.023초

CoCrTa/Cr-X 자성박막의 자기적성질에 미치는 첨가원소 X의 영향 (The Effect of Additional Elements X on Magnetic Properties of CoCrTa/Cr-X Thin Film)

  • 김준학;박정용;남인탁;홍양기
    • 한국자기학회지
    • /
    • 제3권4호
    • /
    • pp.314-319
    • /
    • 1993
  • Co-12at%Cr-2at%Ta/Cr-X 자성박막의 자기적성질과 미세구조에 미치는 첨가원소 X(X=Si, Mo, Cu, Gd)의 영향에 대해 조사하였다. Cr-X 하지층 및 CoCrTa 자성층의 두께는 각각 $1000~2000\AA$$200~800\AA$이었으며, 기판온도는 $100~200^{\circ}C$로 변화시켰다. Cr-X 하지층은 순수한 Cr 하지층에 비하여 보자력이 100 Oe~200 Oe 이상 증가하였다. Cu는 Gd, Mo, Si보다 높은 보자력 을 나타내는 Cr-X 하지층의 첨가원소 였으며 CoCrTa/Cr-Cu 자성박막은 하지층두께 $1500\AA$과 자성층두께 $600\AA$에서 높은 보자력을 나타내었다.

  • PDF

고속도금된 Zn-Cr 및 Zn-Cr-X 3원합금 도금층의 표면조직, 광택도 및 경도 (Surface morphology, Glossiness and Hardness of Zn-Cr and Zn-Cr-X ternary alloy Electrodeposits)

  • 예길촌;김대영;서경훈
    • 한국표면공학회지
    • /
    • 제36권5호
    • /
    • pp.379-385
    • /
    • 2003
  • The surface morphology, the glossiness and the hardness of Zn-Cr and Zn-Cr-X(X:Co, Mn) alloy electrodeposits were investigated by using chloride bath with EDTA additive and flow cell system. The surface morphology of Zn-Cr alloy and Zn-Cr-Mn alloy changed from fine needle shape crystalline structure to colony structure of fine granular crystallites with increasing current density in the range of 20-100 $A/dm^2$. The surface morphology of Zn-Cr-Co alloy deposited from low Co concentration bath(2.5-10 g/$\ell$) was similar to that of Zn-Cr alloy, while that of Zn-Cr-Co alloy deposited from high cobalt concentration bath was fine granular crystalline structure in the same range of current density. The glossiness of Zn-Cr and Zn-Cr-Mn alloy increased noticeably with increasing current density, while that of Zn-Cr-Mn alloy decreased with increasing Mn concentration of bath in high current density region. The glossiness of Zn-Cr-Co alloy deposited from low Co concentration bath increased with current density while that of the alloy from high Co concentration bath decreased with increasing current density. The hardness of Zn-Cr and Zn-Cr-X alloy increased noticeably with current density.

Ti 및 Mo 첨가에 따른 치과 CAD/CAM용 Ni-Cr 및 Co-Cr합금의 표면분석 (Surface Analysis of Ni-Cr and Co-Cr Alloys with Addition of Ti and Mo for Dental CAD/CAM Use)

  • 문대선;최한철
    • 한국표면공학회지
    • /
    • 제51권3호
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, surface analysis of Ni-Cr and Co-Cr alloys with addition of Ti and Mo for dental CAD/CAM use has been researched experimentally. The surface characteristics of the alloys were examined by Vickers hardness test, bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction spectroscopy. The shrinkage of the sintered Ni-Cr alloy alloy was slightly larger than that of Ni-Cr-Ti alloy, and larger than Co-Cr alloy. Also, the addition of Mo showed a tendency to decrease shrinkage somewhat. From the result of XRD analysis, NiCr, $Ni_3Cr$ and $Ni_3Ti$ were observed in the sintered Ni-13Cr-xTi and Ni-13Cr-xMo alloys. In addition, ${\sigma}-CrCo$, $Co_2Mo_3$ and $TiCo_2$ were formed in the sintered Co-Cr-xTi and Co-Cr-xMo alloys. Surface hardness of Ti and Mo added alloy was higher than those of Ni-Cr and Co-Cr alloy. The bond strength between sintered alloy and porcelain was $16.1kgf/mm^2$ for Ni-13Cr alloy, $17.8kgf/mm^2$ for Ni-13Cr-5Ti alloy, and $8.2kgf/mm^2$ for Ni-13Cr-10Ti alloy, respectively.

LaCrxCo1-xO3/Li1.3Al0.3Ti1.7(PO4)3의 적층구조를 가지는 가스센서 제조와 그의 NOx 검지특성 (Fabrication of Stack-Structured Gas Sensor of LaCrxCo1-xO3/Li1.3Al0.3Ti1.7(PO4)3 and Its NOx Sensing Properties)

  • 이영성;;송정환
    • 한국재료학회지
    • /
    • 제25권8호
    • /
    • pp.423-428
    • /
    • 2015
  • Impedancemetric $NO_x$ (NO and $NO_2$) gas sensors were designed with a stacked-layer structure and fabricated using $LaCr_xCo_{1-x}O_3$ (x = 0, 0.2, 0.5, 0.8 and 1) as the receptor material and $Li_{1.3}Al_{0.3}Ti_{1.7}(PO_4)_3$ plates as the solid-electrolyte transducer material. The $LaCr_xCo_{1-x}O_3$ layers were prepared with a polymeric precursor method that used ethylene glycol as the solvent, acetyl acetone as the chelating agent, and polyvinylpyrrolidone as the polymer additive. The effects of the Co concentration on the structural, morphological, and $NO_x$ sensing properties of the $LaCr_xCo_{1-x}O_3$ powders were investigated with powder X-ray diffraction, field emission scanning electron microscopy, and its response to 20~250 ppm of $NO_x$ at $400^{\circ}C$ (for 1 kHz and 0.5 V), respectively. When the as-prepared precursors were calcined at $700^{\circ}C$, only a single phase was detected, which corresponded to a perovskite-type structure. The XRD results showed that as the Co concentration of the $LaCr_xCo_{1-x}O_3$powders increased, the crystal structure was transformed from an orthorhombic phase to a rhombohedral phase. Moreover, the $LaCr_xCo_{1-x}O_3$ powders with $0{\leq}x<0.8$ had a rhombohedral symmetry. The size of the particles in the $LaCr_xCo_{1-x}O_3$powders increased from 0.1 to $0.5{\mu}m$ as the Co concentration increased. The sensing performance of the stack-structured $LaCr_xCo_{1-x}O_3/Li_{1.3}Al_{0.3}Ti_{1.7}(PO_4)_3$ sensors was found to divide the impedance component between the resistance and capacitance. The response of these sensors to NO gas was more sensitive than that to $NO_2$ gas. Compared to other impedancemetric sensors, the $LaCr_{0.8}Co_{0.2}O_3/Li_{1.3}Al_{0.3}Ti_{1.7}(PO_4)_3$ sensor exhibited good reversibility and reliable sensingresponse properties for $NO_x$ gases.

고속도금된 Zn-Cr 및 Zn-Cr-X 3원합금의 전류효율 및 조성 (Current Efficiency and Composit ion of Zn-Cr and Zn-Cr-X Ternary Alloy Electrodeposits)

  • 예길촌;김대영;안덕수
    • 한국표면공학회지
    • /
    • 제36권3호
    • /
    • pp.256-262
    • /
    • 2003
  • The current efficiency and the composition of Zn-Cr and Zn-Cr-X (X : Co, Mn) alloy electrodeposits were investigated by using chloride bath with EDTA auditive and flow cell plating system. The current efficiency of Zn-Cr alloy decreased with increasing current density, while it increased with the content of Co and Mn of the Zn-Cr-X alloy bath in high current density region. The Cr content in Zn-Cr alloy increased from 1.4-2.7 to $28wt\%$ with increasing current density and the phase structure of the alloys changed from $\eta-Zn$ through $\eta-Zn+\gamma'-ZnCr\;to\;\gamma'-ZnCr$ with Increasing Cr content of the alloys. The Co content in Zn-Cr-Co alloys increased with Co content of the bath, while Cr content of the alloy increased or decreased in low current density region $(10-75A/dm^2)$ or high current density region $(75-100A/dm^2)$, respectively. $\gamma-ZnCo$ phase was formed in the Zn-Cr-Co alloy with above $9.0wt\%$ Co. The content of Mn and Cr in Zn-Cr-Mn alloys increased or decreased with the increase of current density in high current density region, respectively while Cr content of the alloy decreased noticeably with the increase of Mn content in the bath. Two phases of $\delta_1-ZnMn$ and $\gamma'-ZnCr$ were formed in the Zn-Cr-Mn alloy with above $8.6wt\%$ Mn.

졸-겔 방법을 이용하여 제작된 (Mn, Cr)xCo1-xFe2O4 박막의 구조적, 자기적 특성 (Structural and Magnetic Properties of (Mn, Cr)xCo1-xFe2O4 Thin Films Prepared by Sol-gel Method)

  • 김광주;김희경;박영란;박재윤
    • 한국자기학회지
    • /
    • 제16권1호
    • /
    • pp.23-27
    • /
    • 2006
  • 역스피넬 산화물 $CoFe_2O_4$에서 Co를 Mn 또는 Cr클 치환하여 얻어지는 $Mn_xCo_{1-x}Fe_2O_4$$Cr_xCo_{1-x}Fe_2P_4$ 박막시료 들을 졸-겔 방법을 이용하여 제작하고 그 구조적, 자기적 특성들을 비교분석 하였다. X-ray diffraction 측정 결과, Mn 치환의 경우는 치환량의 증가에 따라 격자상수가 증가하였지만 Cr치환의 경우는 격자상수가 거의 변화하지 않음이 관측되었다. 이와 같은 결과는 Mn 치환의 경우 팔면체 자리의 Co이온과 같은 원자가 +2를 가지게 되는 것으로 설명 가능하며 Cr치환의 경우는 +3을 가지게 되어 같은 양의 $Fe^{3+}$이온들의 $Fe^{2+}$로의 환원이 발생하는 것으로 설명되어질 수 있다. $Cr_Co_{1-x}Fe_2O_4$박막들에 대한 Mossbauer 스펙트럼 측정 결과 사면체 자리에 $Fe^{2+}$이온의 존재가 관측되었으며 이는 $Cr^{3+}$이온의 팔면체 자리 치환에 의하여 야기되는 사면체 자리의 $Fe^{3+}{\rightarrow}Fe^{2+}$ 환원에 의한 것으로 해석된다. 반면에 $Mn_xCo_{1-x}Fe_2O_4$ 박막들에 대한 Mossbauer스펙트럼 측정 결과, $Fe^{2+}$ 이온의 존재는 관측되지 않았으며 Mn 치환량이 큰 경우 (>0.47)팔면체 자리의 $Fe^{3+}$이온들의 사면체 자리로의 이동이 관측되었다. 박막들에 대한 진동시료자화(vibrating sample magnetometry)측정 결과, Mn, Cr 치환의 경우 모두 $CoFe_2O_4$와 비교하여 포화자화량이 증가함이 나타났으며 치환에 관여한 이온들 간의 스핀 자기 능률 크기의 비교를 통하여 그 정성적인 설명이 가능하다.

Mossbauer 분광법에 의한 $CoCr_xFe_{2-x}O_4$의 연구 (Mossbauer study of $CoCr_xFe_{2-x}O_4$)

  • 채광표;이혁진;이재광;이성호;이영배
    • 한국자기학회지
    • /
    • 제10권2호
    • /
    • pp.74-80
    • /
    • 2000
  • Sol-gel방법을 이용하여 CoCr$_{x}$ Fe$_{2-x}$O$_4$페라이트를 제조하여 Cr의 치환량에 따른 결정학적 특성과 자기적인 특성을 x-ray, SEM, M ssbauer 분광기와 VSM 등으로 분석하였다. 시료는 cubic spinel 구조를 가지며, Cr의 치환량이 증가함에 따라 격자상수는 약간씩 감소하였으며. 입자 크기도 Cr의 치환량이 증가함에 따라 감소하였다. 상온에서의 Mossbauer 스펙트럼은 Fe$^{3+}$ 이온에 의한 두 개의 육중선 세트(0.0$\leq$x$\leq$0.6)에서 상자성의 이중선(0.8$\leq$x$\leq$1.0)으로 변해갔다. Cr의 치환량의 증가에 따라 초미세자기장 값은 감소하였으나 이성질체이동 값과 사중극자분열 값은 거의 일정하였다. 온도 변화에 따른 Mossbauer 스펙트럼 분석 결과 0.8$\leq$x$\leq$1.0시료에서 나타난 이중선은 열에 의한 전자적 완화 현상으로 생각되었다. CoCr$_{x}$ Fe$_{2-x}$O$_4$시료에서 x=0.0의 보자력은 2024 Oe이고, 포화 자화는 78.1 emu/g의 값을 나타냈으며, x=1.0에서는 보자력이 7.858 Oe, 포화 자화는 12.07 emu/g의 값으로 감소하였다. 특이한 점은 x=0.1에서 보자력이 1095 Oe로 x=0.0 값에 비해 약 절반 정도의 값으로 감소한 것으로 Cr의 미량 치환에 의해 자기적 특성이 급격히 변함을 알았다 알았다

  • PDF