• Title/Summary/Keyword: $Cp_2TiCl_2$

Search Result 31, Processing Time 0.025 seconds

Dehydrogenative Polymerization of New Alkylsilanes Catalyzed by $Cp_2MCl_2$/Red-Al System (M=Ti, Hf): Synthesis of Poly(substituted 3-phenyl-1-silabutanes)

  • U, Hui Gwon;Han, Mi Gyeong;Jo, Eun Jeong;Jeong, Il Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.1
    • /
    • pp.58-62
    • /
    • 1995
  • Substituted 3-phenyl-1-silabutanes such as 3-phenyl-1-silabutane (1), 3-(2,5-dimethylphenyl)-1-silabutane (2), 3-(p-chlorotolyl)-1-silabutane (3), and 3-naphthyl-1-silabutane (4) were prepared in 62-96% yield by reduction of the corresponding substituted 3-phenyl-1,1-dichloro-1-silabutanes with LiAlH4. The dehydrogenative polymerization of the monomer silanes was carried out with Cp2MCl2/Red-Al (M=Ti, Hf) catalyst system. The molecular weight of the polymers produced ranged from 700 to 1300 (vs polystyrene) with degree of polymerization (DP) of 5 through 16 and with polydispersity index (PDI)=1.1-2.1. The dehydrogenative polymerization of the monomer silanes with Cp2TiCl2/Red-Al catalyst system occurred at a faster rate and produced somewhat higher molecular weights of polysilane than that with Cp2HfCl2/Red-Al catalyst system.

Dehydrogenative Polymerization of New Alkylsilanes Catalyzed by $Cp_2MCl_2$/Red-Al System (M=Ti, Hf)

  • 우희권;김숙연;조은정;정일남
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.2
    • /
    • pp.138-143
    • /
    • 1995
  • Substituted 3-phenyl-1-silabutanes, 3-chlorophenyl-1-silabutane (1), 3-tolyl-1-silabutane (2), and 3-phenoxyphenyl-1-silabutane (3), were prepared in 68-98% yield by reduction of the corresponding substituted 3-phenyl-1,1-dichloro-1-silabutanes with LiAlH4. The dehydrogenative homopolymerization and copolymerization of the silanes were performed with Cp2MCl2/Red-Al (M=Ti, Hf) catalyst system. The molecular weights of the resulting polymers were in the of range 600 to 1100 (vs polystyrene) with degree of polymerization (DP) of 5 to 8 and polydispersity index (PDI) of 1.6 to 3.8. The monomer silanes underwent the dehydrogenative polymerization with Cp2TiCl2/Red-Al catalyst to produce somewhat higher molecular weight polysilanes compared with Cp2HfCl2/Red-Al catalyst.

Theoretical Studies of $d^0$ Titanocene Complexes

  • Kang, Sung-Kwon;Ahn, Byeong-Gak;Choi, Eun-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.11
    • /
    • pp.996-1000
    • /
    • 1994
  • Ab initio calculations with various basis sets have been carried out to investigate the geometries and ring inversion barrier of $R_2TiC_3H_6\;and\;R_2TiS_3$, R=Cp and Cl. Optimized geometries of $R_2TiC_3H_6$ showed the four membered ring was planar on Cs symmetry. However, $R_2TiS_3$ complexes were optimized to be stable in the puckered form. The smallest Basis III with STO-3G on Cp ligands gave reasonable results for the calculations of metallocene. The energy barrier for the ring inversion of metallacyclosulfanes, $Cp_2TiS_3$ was computed to be 8.72 kcal/mol at MP2 level. For the Cl system, we reproduced the molecular structure and ring inversion energy with Basis V.

Titanium Complexes: A Possible Catalyst for Controlled Radical Polymerization

  • Kwark, Young-Je;Kim, Jeong-Han;Novak Bruce M.
    • Macromolecular Research
    • /
    • v.15 no.1
    • /
    • pp.31-38
    • /
    • 2007
  • Pentamethylcyclopentadienyltitanium trichloride, bis(cyclopentadienyl)titanium dichloride ($Cp_2TiCl_2$), and bis(pentamethylcyclopentadienyl)titanium dichloride were used in the polymerization of styrene without the aid of Group I-III cocatalysts. The properties of the resulting polymer indicated that polymerization was more controlled than in thermal polymerization. The kinetic studies indicated that a lower level of termination is present and that the polymer chain can be extended by adding an additional monomer. To elucidate the mechanism of polymerization, a series of experiments was performed. All results supported the involvement of a radical mechanism in the polymerization using $Cp_2TiCl_2$. The possibility of atom transfer radical polymerization (ATRP) mechanism was investigated by isolating the intermediate species. We could confirm the activation step from the reaction of 1-PEC1 with $Cp_2TiCl$ by detecting the coupling product of the generated active radicals. However, the reversible deactivation reaction competes with other side reactions, and it detection was difficult with our model system.

Corrosion behaviors of Cp-Ti and Ti-6Al-4V alloys by TiN coating (TiN 코팅된 Ti 및 Ti-6Al-4V합금의 부식거동)

  • Lee, Soon-Hyun;Jung, Yoong-Hun;Choi, Han-Chul;Ko, Yeong-Mu
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • Cp-Ti and Ti-6Al-4V alloys commonly used dental implant materials, particularly for orthopaedic and osteosynthesis because of its suitable mechanical properties and excellent biocompatibility. This alloys have excellent corrosion behavior in the clinical environment. The first factor to decide the success of dental implantation is sufficient osseointegration and high corrosion resistance between on implant fixture and its surrounding bone tissue. In this study, in order to increase corrosion resistance and biocompatibility of Cp-Ti and Ti-6Al-4V alloy that surface of manufactured alloy was coated with TiN by RF-magnetron sputtering method. The electrochemical behavior of TiN coated Cp-Ti and Ti-6Al-4V alloy were investigated using potentiodynamic (EG&G Co, PARSTAT 2273. USA) and potentiostatic test (250mV) in 0.9% NaCl solution at 36.5 $\pm$ 1$^{\circ}C$. These results are as follows : 1. From the microstructure analysis, Cp-Ti showed the acicular structure of $\alpha$-phase and Ti-6Al-4V showed the micro-acicular structure of ${\alpha}+{\beta}$ phase. 2. From the potentiodynamic test, Ecorr value of Cp-Ti and Ti-6Al-4V alloys showed -702.48mV and -319.87mV, respectively. Ti-6Al-4V alloy value was higher than Cp-Ti alloy. 3. From the analysis of TiN and coated layer, TIN coated surface showed columnar structure with 800 nm thickness. 4. The corrosion resistance of TiN coated Cp-Ti and Ti-6Al-4V alloys were higher than those of the non-coated Ti alloys in 0.9% NaCl solution from potentiodynamic test, indicating better protective effect. 5. The passivation current density of TiN coated Cp-Ti and Ti-6Al-4V alloys were smaller than that of the noncoated implant fixture in 0.9% NaCl solution, indicating the good protective effect resulting from more compact and homogeneous layer formation.

  • PDF

A study on corrosion resistance of Ti-Nb alloys by Nb contents (Nb 함량에 따른 Ti-Nb계 합금의 내식성에 대한 연구)

  • Park, Geun-Hyeung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • Titanium alloys have been used for dental materials due to it's very good biocompatibility. Ti-6Al-4V alloy instead of pure titanium is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength and corrosion resistance. But it has been reported recently that the vanadium element expresses cytotoxicity and carcinogenicity and the aluminium element is related with dementia of Alzheimer type and neurotoxicity. The Ti-Nb alloys has designed and examined corrosion resistance. Ti-3wt.%Nb($\alpha$type), Ti-20wt.%Nb(${\alpha}+{\beta}$type) and Ti-40wt.%Nb($\beta$type) alloys were melted by vacuum arc furnace. The corrosion resistance of Ti alloys was evaluated by potentiodynamic polarization test in the solution of 0.9% NaCl and 5% HCl. The results can be summarized as follows: 1) For the corrosion test in the solution of 0.9% NaCl and 5% HCl, the corrosion behaviour of Ti-Nb alloys was similar to ASTM grade 2 CP Ti. 2) The corrosion resistance of Ti-20Nb alloy was better than that of CP-Ti, Ti-3Nb, Ti-40Nb alloy in 0.9% NaCl and 5% HCl, solutions.

  • PDF

A.c. Impedance Measurement of CP-Ti in 0.1 M NaOH Solution

  • Moon, Sungmo;Kwon, Mikyung;Kim, Jusuk
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.185-189
    • /
    • 2012
  • A.c. impedances of mechanically polished CP-Ti specimens were measured at open-circuit potential (OCP) with immersion time and under applied anodic potentials between -0.2 and 1 $V_{Ag/AgCl}$ in 0.1 M NaOH solution. Capacitances of native oxide films ($C_{ox,na}$) grown naturally and capacitances of anodic oxide films ($C_{ox,an}$) formed under applied anodic potentials were obtained to examine the growth of native and anodic oxide films in 0.1 M NaOH solution and how to use $C_{ox,na}$ for the surface area measurement of Ti specimen. $1/C_{ox,na}$ and $1/C_{ox,an}$ appeared to be linearly proportional to OCP and applied potential ($E_{app}$), with proportional constants of 0.086 and 0.051 $uF^{-1}\;V^{-1}$, respectively. The $C_{ox,na}$ also appeared to be linearly proportional to geometric surface area of the mechanically polished CP-Ti fixture specimen, with proportional constants of 11.3 and $8.5{\mu}F\;cm^{-2}$ at -0.45 $V_{Ag/AgCl}$ and -0.25 $V_{Ag/AgCl}$ of OCPs, respectively, in 0.1 M NaOH solution. This linear relationship between $C_{ox,na}$ and surface area is suggested to be applicable for the measurement of real surface area of Ti specimen.