• 제목/요약/키워드: $Cl^-$ ions

검색결과 883건 처리시간 0.02초

A Study on groundwater and pollutant recharge in urban area: use of hydrochemical data

  • Lee, Ju-Hee;Kwon, Jang-Soon;Yun, Seong-Taek;Chae, Gi-Tak;Park, Seong-Sook
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.119-120
    • /
    • 2004
  • Urban groundwater has a unique hydrologic system because of the complex surface and subsurface infrastructures such as deep foundation of many high buildings, subway systems, and sewers and public water supply systems. It generally has been considered that increased surface impermeability reduces the amount of groundwater recharge. On the other hand, leaks from sewers and public water supply systems may generate the large amounts of recharges. All of these urban facilities also may change the groundwater quality by the recharge of a myriad of contaminants. This study was performed to determine the factors controlling the recharge of deep groundwater in an urban area, based on the hydrogeochemical characteristics. The term ‘contamination’ in this study means any kind of inflow of shallow groundwater regardless of clean or contaminated. For this study, urban groundwater samples were collected from a total of 310 preexisting wells with the depth over 100 m. Random sampling method was used to select the wells for this study. Major cations together with Si, Al, Fe, Pb, Hg and Mn were analyzed by ICP-AES, and Cl, N $O_3$, N $H_4$, F, Br, S $O_4$and P $O_4$ were analyzed by IC. There are two groups of groundwater, based on hydrochemical characteristics. The first group is distributed broadly from Ca-HC $O_3$ type to Ca-C1+N $O_3$ type; the other group is the Na+K-HC $O_3$ type. The latter group is considered to represent the baseline quality of deep groundwater in the study area. Using the major ions data for the Na+K-HC $O_3$ type water, we evaluated the extent of groundwater contamination, assuming that if subtract the baseline composition from acquired data for a specific water, the remaining concentrations may indicate the degree of contamination. The remainder of each solute for each sample was simply averaged. The results showed that both Ca and HC $O_3$ represent the typical solutes which are quite enriched in urban groundwater. In particular, the P$CO_2$ values calculated using PHREEQC (version 2.8) showed a correlation with the concentrations of maior inorganic components (Na, Mg, Ca, N $O_3$, S $O_4$, etc.). The p$CO_2$ values for the first group waters widely ranged between about 10$^{-3.0}$ atm to 10$^{-1.0}$ atm and differed from those of the background water samples belonging to the Na+K-HC $O_3$ type (<10$^{-3.5}$ atm). Considering that the p$CO_2$ of soil water (near 10$^{-1.5}$ atm), this indicates that inflow of shallow water is very significant in deep groundwaters in the study area. Furthermore, the P$CO_2$ values can be used as an effective parameter to estimate the relative recharge of shallow water and thus the contamination susceptibility. The results of our present study suggest that down to considerable depth, urban groundwater in crystalline aquifer may be considerably affected by the recharge of shallow water (and pollutants) from an adjacent area. We also suggest that for such evaluation, careful examination of systematically collected hydrochemical data is requisite as an effective tool, in addition to hydrologic and hydrogeologic interpretation.ion.ion.

  • PDF

토양의 용적밀도에 따른 포화수리전도도 및 음이온의 용출양상 (Effects of Soil Bulk Density on Saturated Hydraulic Conductivity and Solute Elution Patterns)

  • 김필주;이도경;정덕영
    • 한국토양비료학회지
    • /
    • 제30권3호
    • /
    • pp.234-241
    • /
    • 1997
  • 시설 재배지내 염류집적의 원인의 하나인 토양의 용적밀도 변화가 염류집적에 미치는 영향을 조사하기 위해, 충남 예산군 오가면의 시설재배 10여년 연작지 토양의 Ap층을 이용하여 용적밀도 변화에 따른 수리전도도 변화와 전기전도도 및 음이온의 용출특성 변화를 토주(土柱)실험을 통해 조사하였다. 수리전도도(Y, cm/day)와 용적별도(X, $Mg/m^3$)간에는 부의 회귀관계 ($Y=-19.2X^2+6X+15.5$, (r=0.985)) 가 성립하여, 낮은 용적밀도에서는 큰 폭의 수리전도도 감소가 있으며, $1.4Mg/m^3$ 이상의 높은 용적밀도 조건에서는 용적밀도 변화에 따른 수리전도도 변화가 매우 미미 하였다. 위의 5 수준의 용적밀도 조건하에서 시간변화에 따른 용출액 중 용존 물질의 용출속도는 용적밀도 증가에 따라 크게 지연되었다. 용출액의 전기전도도가 최고점에 도달하는 시간을 비교한결과 용적밀도 $1.3Mg/m^3$ 이하에서는 토양단면 10cm를 통과하는데 약 36시간 이내의 시간이 요구되었으며, 용적밀도 $1.4Mg/m^3$ 이상에는 120시간 이상이 요구되어 두 조건사이 약 84시간의 사이가 있었다. 토양내 이행성이 높은 주요 3가지 음이온의 용출속도도 용적밀도 증가에 따라 크게 지연되었으며, 용적밀도 $1.2Mg/m^3$ 일 때 Chloride, Nitrate와 Sulphate가 90%이상 용출 되는데 각각 17, 15, 35시간이 소요된 반면, 용적밀도 $1.5Mg/m^3$ 일 때 각각은 90%이상 용출 되는데 약 130, 125, 213시간이 각각 소요되었다. 따라서 경작층 전후의 큰 용적밀도 차이를 보이고 있는 충남 예산 지역의 시설재배지내 염류집적의 원인들 중 경작층 이하인 지표면 아래 20~30cm 부근에 형성된 용적밀도(容積密度) $1.5Mg/m^3$ 이상인 경반층(硬盤層)에 의한 토양수 흐름과 각종 무기염류의 이동 지연으로 인해 크게 악화되고, 지표면에 염류집적이 가속화된 것으로 판단된다.

  • PDF

폐광지역에서 분리한 Benzoate 분해세균 Pseudomonas sp. NEQ-1에서 정제된 Catechol 1,2-Dioxygenase의 특성 (Characterization of Catechol l,2-Dioxygenase Purified from the Benzoate Degrading Bacterium, Pseudomonas sp. NFQ-l Isolated from Dead Coal Pit Areas)

  • 주정수;윤경하
    • 미생물학회지
    • /
    • 제40권4호
    • /
    • pp.275-281
    • /
    • 2004
  • Quinoline (2,3-benzopyridine)을 유일한 탄소원과 질소원, 그리고 에너지원으로 이용하는Pseudomonas sp. NEQ-1을 실험 균주로 사용하였으며, 균주로부터 catechol 1,2-dioxygenase (C1,2O)를 유도하기 위하여 탄소원으로 benzoate를사 용하였다. C1,2O의 효소학적 특징을 조사하기 위하여 benzoate에서 배양한 Pseudomonas sp. NFQ-1을 초음파 분쇄기로 파쇄하고, ammonium sulfate침전과 gel permeation chromatography및 Source 15Q의 과정을 실시하여 C1,2O를 분리 및 정제하였다. 정제된 C1,2O의 특이활성(specific activity)은 14.21 unit/mg으로 나타났으며, SDS-PAGE에 의해 조사된 C1,2O의 분자량은 약 33 kDa이었다. Cl,2O는 catechol과 4-methylcatechol 및 3-methylcatechol에 대해서 효소활성을 나타내는 것으로 확인되었다. C1,2O의 Km은 38.54 ${\mu}M$로 측정되었고, Vmax는 $25.10\;{\mu}mol{\cdot}min^{-1}{\cdot}mg^{-1}$으로 나타났다. C1,2O는 $30^{\circ}C$와 pH 8.5에서 최적활성을 나타내는 것으로 조사되었으며, $Ag^+,\;Hg^+,\;Ca^{2+}$,그리고 $Cu^{2+}$는 C1,2O의 활성을 억제하였다. 분석되어진 N-말단 아미노산 서열은 ^1TVKISQSASIQKFFEEA^{17}$이었으며, Pseudomonas aeruginosa PA01과 $82\%$로 가장 높은 유사성을 보였고 Pseudomonas arvilla C-1와는 $71\%,$ Pseudomonas putida KT2440과는 $59\%,$ 그리고 Pseudomonas sp. CA10과는 $53\%$의 상동성이 각각 존재하는 것으로 확인하였다.