• Title/Summary/Keyword: $C_{}$ max/

Search Result 1,798, Processing Time 0.037 seconds

Bioequivalence of Famvir Tablet 750 mg to Famcivir Tablet 750 mg (Famciclovir 750 mg) (팜비어 정 750밀리그람(팜시클로버 750밀리그람)에 대한 팜시버 정 750밀리그람의 생물학적동등성)

  • Kim, Se-Mi;Yoon, Hwa;Yoo, Hee-Doo;Kim, Kyung-Ran;Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.3
    • /
    • pp.199-205
    • /
    • 2008
  • Famciclovir, 9-(4-hydroxy-3-hydroxymethylbut-1-yl) guanine, is an oral prodrug of the antiherpesvirus nucleoside analogue, penciclovir. In human, famciclovir is orally well absorbed and then undergoes extensive first pass metabolism to penciclovir and essentially no parent compound is recovered from plasma or urine. The purpose of the present study was to evaluate the bioequivalence of two famciclovir tablets, Famvir tablet 750 mg (Novartis Korea Ltd.) and Famcivir tablet 750 mg (Hanmi Pharmaceutical. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of famciclovir from the two famciclovir formulations in vitro was tested using KP VIII Apparatus II method with water. Twenty six healthy male subjects, $23.38{\pm}1.72$ years in age and $68.59{\pm}7.84\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single tablet containing 750 mg as famciclovir was orally administered, blood samples were taken at predetermined time intervals and the concentrations of penciclovir in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations ere similar at water. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Famvir^{(R)}$ tablet 750 mg, were -0.53%, 1.12% and -24.82% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $log\;0.9569{\sim}log\;1.0423$ and $log\;0.8763{\sim}log\;1.2136$ for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Famcivir tablet 750 mg was bioequivalent to Famvir tablet 750 mg.

Bioequivalence of Procare Tablet to Proscar® Tablet (Finasteride 5 mg) (프로스카 정(피나스테리드 5 mg)에 대한 푸로케어 정의 생물학적동등성)

  • Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.143-148
    • /
    • 2006
  • Finasteride $[N-(1, 1-dimethylethyl)-3-oxo-4-aza-5{\alpha}-androst-1-ene-17{\beta}-carboxamide]$ is a 4-aza-3-oxosteroidal inhibitor of human $5{\alpha}-reductase$. The purpose of the present study was to evaluate the bioequivalence of two finasteride tablets, $Proscar^{\circledR}$ (MSD Korea Ltd.) and Procare (Hana Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of finasteride from the two finasteride formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty six healthy male subjects, $23.7\;{\pm}\;2.24$ years in age and $67.2\;{\pm}\;8.55\;kg$ in body weight, were divided into two groups and a randomized $2\;{\time}\;2$ cross-over study was employed. After two tablets containing 5 mg as finasteride was orally administered, blood samples were taken at predetermined time intervals and the concentrations of finasteride in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t,\;C_{max},\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t,\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Proscar^{\circledR}$, were 6.39, 4.65 and -13.9% for $AUC_t,\;C_{max},\;and\;T_{max},$ respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.800 to log 1.25 $(e.g.,\;log\;0.990{\sim}log\;1.14\;and\;log\;0.977{\sim}log\;1.13 for\;AUC_t\;and\;C_{max},\;respectively)$. Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Procare tablet was bioequivalent to $Proscar^{\circledR}$ tablet.

Bioequivalence of Hana Loxoprofen Sodium Tablet to Dongwha Loxonin® Tablet (Loxoprofen Sodium 60 mg)

  • Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.2
    • /
    • pp.117-123
    • /
    • 2011
  • Loxoprofen sodium, a 2-phenylpropionate non-steroidal anti-inflammatory drug (NSAID), has marked analgesic and antipyretic activities and relatively weak gastrointestinal ulcerogenicity. The purpose of the present study was to evaluate the bioequivalence of two loxoprofen sodium tablets, Hana loxoprofen sodium tablet (Hana Pharm. Co., Ltd.) and Dongwha Loxonin$^{(R)}$ tablet (Dongwha Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of loxoprofen from the two loxoprofen sodium formulations was tested using KP IX Apparatus II method with various dissolution media. Twenty four healthy Korean male volunteers, $22.83{\pm}1.862$ years in age and $69.92{\pm}9.14$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ crossover study was employed. After a single tablet containing 60 mg as loxoprofen sodium was orally administered, blood samples were taken at predetermined time intervals and the concentrations of loxoprofen in serum were determined using a online column-switching HPLC method with UV/Vis detection. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC^t$, $C_{max}$ and $T_{max}$ were calculated, and computer programs (Equiv Test and K-BE Test 2002) were utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and un-transformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, Dongwha Loxonin$^{(R)}$ tablet, were 2.03, 2.99 and -9.49% for $AUC_t$, $C_{max}$, and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log0.8 to log1.25 (e.g., log0.9831~log1.0535 and log0.9455~log1.1386 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Hana loxoprofen sodium tablet was bioequivalent to Dongwha Loxonin$^{(R)}$ tablet.

Bioequivalence of Losata Tablet to Cozaar Tablet (Losartan Potassium 50 mg) using HPLC with Fluorescence Detector (고속액체크로마토그래피-형광검출기를 이용한 코자 정(로자탄칼륨 50 mg)에 대한 로사타 정의 생물학적동등성)

  • Kang, Hyun-Ah;Kim, Se-Mi;Yoo, Dong-Jin;Kang, Seung-Rae;Lee, Sang-No;Kim, Yong-Hee;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.1
    • /
    • pp.51-57
    • /
    • 2010
  • Losartan potassium, 2-butyl-4-chloro-1-[p-(o-1H-tetrazol-5-ylphenyl)benzyl]imidazole-5-methanol mono-potassium salt, is a new class of antihypertensive agents, and is an antagonist in angiotensin receptor. The purpose of the present study was to evaluate the bioequivalence of two Losartan potassium tablets, Cozaar tablet (MSD Pharmaceutical Co., Ltd.) and Losata tablet (Kyung Dong Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of losartan from the two losartan potassium formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media. Twenty eight healthy male subjects, $23.86{\pm}1.80$ years in age and $67.27{\pm}6.60\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single tablet containing 50 mg as losartan potassium was orally administered, blood samples were taken at predetermined time intervals, and the concentrations of losartan in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and Equiv Test/K-BE Test 2002 was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, Cozaar, were -2.70%, 1.45% and 2.31% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.8852~log 1.0655 and log 0.8319~log 1.2342 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Losata tablet was bioequivalent to Cozaar tablet.

Bioequivalence Test of Gabapentin 800 mg Tablets (가바펜틴 800밀리그람 정제의 생물학적동등성시험)

  • Kim, Se-Mi;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • YAKHAK HOEJI
    • /
    • v.52 no.4
    • /
    • pp.299-305
    • /
    • 2008
  • Gabapentin, 1-(aminomethyl) cyclohexaneacetic acid, is a amino acid derivative, and is clinically effective in the treatment of neuropathic pain and partial seizures of epilepsy as a complementary therapy. The purpose of the present study was to evaluate the bioequivalence of two gabapentin tablets, $Neurontin^{R}$ tablet 800 mg (Pfizer Pharmaceuticals Co., Ltd.) and Gabapenin tablet 800 mg (Hanmi Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of gabapentin from the two gabapentin formulations in vitro was tested using KP VIII Apparatus II method with 0.06 M HCI dissolution media. Twenty six healthy male subjects, $23.85{\pm}2.24$ years in age and $69.40{\pm}11.11$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ crossover study was employed. After a single tablet containing 800 mg as gabapentin was orally administered, blood samples were taken at predetermined time intervals and the concentrations of gabapentin in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar in the tested dissolution media. The pharmacokinetic parameters such as $AUC_{t}$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_{t}$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Neurontin^{R}$, were 1.28%, 0.63% and 0.62% for $AUC_{t}$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $log0.9097{\sim}log1.1598$ and $log0.8919{\sim}log1.1262$ for $AUC_{t}$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Gabapenin tablet 800 mg was bioequivalent to $Neurontin^{R}$ tablet 800 mg.

Bioequivalence of Procezil Tablet 250 mg to $Cefzil^{(R)}$ Tablet 250 mg (Cefprozil 250 mg) (세프질$^{(R)}$ 정 250밀리그람 (세프프로질 250밀리그람)에 대한 프로세질 정 250밀리그람의 생물학적동등성)

  • Kim, Se-Mi;Kang, Min-Sun;Cho, Hea-Young;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.255-261
    • /
    • 2010
  • Cefprozil is a broad-spectrum oral beta-lactam cephalosporin consisting of cis- and trans-isomeric mixture whose ratio is approximately 90:10. Cefprozil is used to treat certain infections caused by bacteria such as bronchitis and ear, skin, and throat infections. The purpose of the present study was to evaluate the bioequivalence of two cefprozil tablets, $Cefzil^{(R)}$ tablet 250 mg (BMS Pharmaceutical Korea., Ltd.) and Procezil tablet 250 mg (Hanmi Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of cefprozil from the two cefprozil formulations were tested using KP VIII Apparatus I method with water dissolution media. Thirty five healthy male subjects, $24.00{\pm}1.53$ years in age and $69.77{\pm}9.99$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After four tablets containing 1000 mg as cefprozil were orally administered, blood samples were taken at predetermined time intervals and the concentrations of cefprozil in serum were determined using HPLC/UV detector. The dissolution profiles of two formulations were similar in water tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ on the basis of total-cefprozil were calculated, and computer program (K-BE Test 2002) was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Cefzil^{(R)}$ tablets, were -0.81%, -3.00% and -6.83% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.9515~log 1.0454 and log 0.9613~log 1.0465 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Procezil tablet was bioequivalent to $Cefzil^{(R)}$ tablet.

Bioequivalence of Bambucol Tablet 10 mg to $Bambec^{(R)}$ Tablet 10 mg (Bambuterol Hydrochloride 10 mg) (밤벡$^{(R)}$ 정 10밀리그람(염산밤부테롤 10밀리그람)에 대한 밤부콜 정 10밀리그람의 생물학적동등성)

  • Cho, Hea-Young;Choi, Ji-Hoon;Yoo, Hee-Doo;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.20 no.3
    • /
    • pp.235-241
    • /
    • 2010
  • Bambuterol hydrochloride, dimethylcarbamic acid 5-[2-(1,1-dimethylethyl)amino-1-hydroxyethyl]-1,3-phenylene ester hydrochloride, is the prodrug of active ${\beta}_2$-adrenergic metabolite terbutaline. The purpose of the present study was to evaluate the bioequivalence of two bambuterol hydrochloride tablets, $Bambec^{(R)}$ tablet 10 mg (Yuhan Co., Ltd.) and Bambucol tablet 10 mg (Sam Chun Dang Pharm. Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). In vitro release of bambuterol from two bambuterol hydrochloride formulations was tested using KP VIII Apparatus II method with various dissolution media. Twenty eight healthy male Korean volunteers, $23.86{\pm}1.65$ years in age and $68.98{\pm}9.58$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After two tablets containing 10 mg as bambuterol hydrochloride were orally administered, blood samples were taken at predetermined time intervals, and the concentrations of bambuterol in serum were determined using column switching HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test with K-BE Test 2002 was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Bambec^{(R)}$, were -8.10%, -3.82% and 12.65% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (i.e., log 0.8093~log 1.0302 and log 0.8564~log 1.1280 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Bambucol tablet 10 mg was bioequivalent to $Bambec^{(R)}$ tablet 10 mg.

Real-Time Micro-Weather Factors of Growing Field to the Epidemics of Rice Blast (벼 도열병 Epidemics에 미치는 재배 포장 실황기상 요인)

  • Kwon, Jae-Oun;Lee, Soon-Gu
    • Research in Plant Disease
    • /
    • v.8 no.4
    • /
    • pp.199-206
    • /
    • 2002
  • It was investigated on the relationship of the rice blast epidemics and the real-time meteorological factors, at the experimental paddy field in 1997. Weather factors(temperature, relative humidity, irradiation, precipitation, the direction of wind, wind speed, soil temperature and leaf-wetness, etc) were measured by using the automated weather station. The most influenced weather factor to blast epidemics, was the average max-temp($R^2$= 0.95) during 10 days before leaf blast epidemics, while the least thing was wind speed($R^2$= 0.24). The most potential weather factors correlated with the blast epidemics were T-ave(average temperature), T-max(maximum temperature), RH(Relative Humidity) and RD(Relative Humidity > 90% hrs). A statistics model(the regression equation) of the blast epidemics with the potential weather factors, was established as tallows ; Y = -3410.91 - 23.91 $\times$ T-ave + 28.56 $\times$ T-max + 41.0 $\times$ RH - 3.75 $\times$ RD, ($R^2$= 0.99). (T-ave >= 19$^{\circ}C$, T-max - T-ave >= 5.2$^{\circ}C$ and RH% >= 90.4%). According to the fitness test($\chi$$^2$) of the model, the observed blast disease severity was quite close to those expected.

Bioequivalence of Lornocam Tablet to Xefo® Tablet (Lornoxicam 4 mg) (제로 정(로녹시캄 4 mg)에 대한 로노캠 정의 생물학적 동등성)

  • Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.67-73
    • /
    • 2006
  • Lornoxicam is a nonsteroidal anti-inflammatory drug that decreases prostaglandin synthesis by inhibiting cyclooxygenase. It has analgesic, antipyretic and antiinflammatory effects. The purpose of the present study was to evaluate the bioequivalence of two lornoxicam tablets, $Xefo^{\circledR}$ (Hyundai Pharmaceutical Ind. Co., Ltd.) and Lornocam (Samchundang Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of lornoxicam from the two lornoxicam formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty eight healthy male subjects, $24.39{\pm}1.95$ years in age and $68.63{\pm}7.25$ kg in body weight, were divided into two groups and a randomized $2\;{\time}\;2$ cross-over study was employed. After a single tablet containing 4 mg as lornoxicam was orally administered, blood samples were taken at predetermined time intervals and the concentrations of lornoxicam in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t,\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Xefo^{\circledR},$ were -1.56%, 2.16% and -17.12% for $AUC_t,\;C_{max}\;and\;T_{max},$ respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $log\;0.90{\sim}log\;1.05$ and $log\; 0.88{\sim}log\;1.17$ for $AUC_t\;and\;C_{max},$ respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Lornocam tablet was bioequivalent to $Xefo^{\circledR}$ tablet.

Bioequivalence of Pinatos Capsule 10 mg to Ketas Capsule 10 mg (Ibudilast 10 mg) (케타스 캡슐 10밀리그램(이부딜라스트 10 밀리그램)에 대한 피나토스 캡슐 10밀리그램의 생물학적동등성)

  • Kang, Hyun-Ah;Kim, Se-Mi;Kang, Min-Sun;Yoo, Dong-Jin;Lee, Sang-No;Kwon, In-Ho;Yoo, Hee-Doo;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.117-123
    • /
    • 2010
  • Ibudilast, 3-isobutyryl-2-isopropyrazolo[1,5-a]pyridine, is a nonselective inhibitor of cyclic nucleotide phosphodiesterase (PDE). It preferentially inhibits PDE 3A, PDE4, PDE10 and PDE11 as well as a number of the other PDE families, albeit to a lesser extent. Ibudilast is used clinically to treat bronchial asthma and cerebrovascular disorders. Thes e clinical uses are based on the ability of ibudilast to inhibit platelet aggregation, improve cerebral blood flow and attenuate allergic reactions. The purpose of the present study was to evaluate the bioequivalence of two ibudilast capsules, Ketas capsule (Handok Pharmaceuticals Co., Ltd.) and Pinatos capsule (Sam Chun Dang Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of ibudilast from the two ibudilast formulations was tested using KP Apparatus method with various dissolution media. Twenty six healthy male subjects, 23.31${\pm}$1.09 years in age and 70.45${\pm}$8.51 kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single capsule containing 10 mg as ibudilast was orally administered, blood samples were taken at predetermined time intervals and the concentrations of ibudilast in serum were determined using HPLC/UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and computer programs (Equiv Test and K-BE Test 2002) were utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, Ketas, were 6.99%, -2.48% and 9.93% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.8791~log 1.1861 and log 0.8347~log 1.1199 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Pinatos capsule was bioequivalent to Ketas capsule.