• Title/Summary/Keyword: $CO_2$ standard gas

Search Result 182, Processing Time 0.034 seconds

Estimation on the Emission Reduction of SULEV LPG Vehicles (SULEV LPG 자동차의 배출가스 저감효과 평가)

  • Park, Jun-Hong;Lee, Jong-Tae;Kim, Sun-Moon;Kim, Jeong-Soo;Kang, Dae-Il;Lim, Yun-Sung;Han, Bo-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.68-76
    • /
    • 2012
  • SULEV (Super Ultra Low Emission Vehicle) which is one of the emission standards in Fleet Average System introduced to Korea from 2009 is known as the most severe standard to achieve with internal combustion engine. Considering low sales volume of hybrid vehicles in Korea, vehicle manufacturers are required to develop SULEV technologies for conventional gasoline and LPG vehicles to meet the future Fleet Average standard. In this study, the comparison of emissions has been made between SULEV developed and ULEV LPG vehicles mainly produced in this time. To estimate the emission reduction of SULEV vehicles, CVS-75 and NIER test modes have been used. CVS-75 has been used for emission certification of gasoline and LPG vehicles. NIER modes cover various average vehicle speed and reflect Korean real driving patterns better than CVS-75. The test results show that SULEV LPG vehicles have very high potential to reduce $NO_x$ in regulated emissions, $N_2O$ in green house gases and toluene in VOCs. However, SULEV LPG vehicles don't affect much on the reduction of CO and total green house gases.

Development of an Editor for Reference Data Library Based on ISO 15926 (ISO 15926 기반의 참조 데이터 라이브러리 편집기의 개발)

  • Jeon, Youngjun;Byon, Su-Jin;Mun, Duhwan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.4
    • /
    • pp.390-401
    • /
    • 2014
  • ISO 15926 is an international standard for integration of lifecycle data for process plants including oil and gas facilities. From the viewpoint of information modeling, ISO 15926 Parts 2 provides the general data model that is designed to be used in conjunction with reference data. Reference data are standard instances that represent classes, objects, properties, and templates common to a number of users, process plants, or both. ISO 15926 Parts 4 and 7 provide the initial set of classes, objects, properties and the initial set of templates, respectively. User-defined reference data specific to companies or organizations are defined by inheriting from the initial reference data and the initial set of templates. In order to support the extension of reference data and templates, an editor that provides creation, deletion and modification functions of user-defined reference data is needed. In this study, an editor for reference data based on ISO 15926 was developed. Sample reference data were encoded in OWL (web ontology language) according to the specification of ISO 15926 Part 8. iRINGTools and dot15926Editor were benchmarked for the design of GUI (graphical user interface). Reference data search, creation, modification, and deletion functions were implemented with XML (extensible markup language) DOM (document object model), and SPARQL (SPARQL protocol and RDF query language).

Study on Forestry-Based Carbon Offset Programs (산림을 이용한 탄소상쇄 프로그램의 해외 사례 고찰)

  • Lee, Seung-Eun
    • Journal of Climate Change Research
    • /
    • v.1 no.2
    • /
    • pp.97-107
    • /
    • 2010
  • A forest project for the sequestration of carbon dioxide helps to reduce the concerntration of greenhouse gas in atmosphere and provides various co-benefits. A lot of forestry-based carbon offset programs have been developing for the purpose of CSR(Corporate Social Responsibility), voluntary GHG emission reduction, and regulatory context etc. in worldwide. We studied major characteristics - project type and criteria, additionality, credits, permanence, carbon accounting and monitoring, co-benefit - of advanced forest carbon offset programs. Also, we tried to comprehend the direction and basic elements to design a domestic program.

Reduction and Decomposition of Hazardous NOx by Discharge Plasma with $TiO_2$ ($TiO_2$ 촉매를 이용한 플라즈마반응에 의한 NOx의 분해)

  • Park, Sung-Gug;Woo, In-Sung;Hwang, Myung-Whan
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.54-60
    • /
    • 2008
  • The objective of this study is to obtain the optimal process condition and the maximum decomposition efficiency by measuring the decomposition efficiency, electricity consumption, and voltage in accordance with the change of the process variables such as the frequency, maintaining time period, concentration, electrode material, thickness of the electrode, the number of windings of the electrode, and added materials etc. of the harmful atmospheric contamination gases such as NO, $NO_2$, and $SO_2$ etc. with the plasma which is generated by the discharging of the specially designed and manufactured $TiO_2$ catalysis reactor and SPCP reactor. The decomposition efficiency of the NO, the standard samples, is obtained with the plasma which is being generated by the discharge of the combination effect of the $TiO_2$ catalysis reactor and SPCP reactor with the variation of those process variables such as the frequency of the high voltage generator($5{\sim}50kHz$), maintaining time of the harmful gases($1{\sim}10.5sec$), initial concentration($100{\sim}1,000ppm$), the material of the electrode(W, Cu, Al), the thickness of the electrode(1, 2, 3mm), the number of the windings of the electrode(7, 9, 11turns), basic gases($N_2$, $O_2$, air), and the simulated gas($CO_2$) and the resulting substances are analyzed by utilizing FT-IR & GC.

A Study on Percent Agent in Pipe as a Criterion to Evaluate Limitations and Performance of Gaseous Fire Extinguishing Systems (가스계 소화설비의 제한사항 및 성능평가를 위한 배관 내 약제비율에 관한 연구)

  • Son, Bong-Sei;Kim, Hee-Woo
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2007
  • This study aims to investigate, review, and summarize the definition, development, and applications of "percent agent in pipe", "percent of agent in pipe" which is used as a key factor in testing and evaluating the performance of gaseous fire extinguishing agents, including Halon 1301 and $CO_2$. This study also analyzes and compares the local and international standards on testing and evaluating the performance of gaseous fire extinguishing systems, as well as the results of system performance tests conducted as a part of performance evaluation and approval programs for gaseous fire extinguishing systems, especially, Korean Gaseous Fire Extinguishing System Performance Approval Program called KFI Approval. Percent agent in pipe was defined first in NFPA 12A, Standard on Halon 1301 Fire Extinguishing Systems, dating back to the 1970's. After the phaseout of Halon 1301 systems in 1994 in the developed countries, the percent agent in pipe has been widely used in Halon 1301 alternative clean agent fire extinguishing systems, both halocarbon clean agent systems and inert gas clean agent systems, as an essential criterion to assure the system design accuracy, determine the limitations and performance of a system, and to predict the system performance results accurately, especially, in association with their system flow calculations. Underwriters Laboratories has their own standards such as UL 2127 and 2166 applying percent agent in pipe in testing and evaluating the performance of clean agent fire extinguishing systems. As a part of a system performance test and approval program called KFI Approval System, Korea also has started to apply the percent agent in pipe as a key factor to test, evaluate, and approve the performance of gaseous fire extinguishing systems, including both high and low pressure $CO_2$ systems, from the early 2000's. This study outlines and summarizes the relevant UL and KFI standards and also describes the actual test resultant data, including the maximum percents of agent in pipe for gaseous fire extinguishing systems. As evidenced in lots of tests conducted as a part of the system performance test and approval programs like KFI Approval System, it has been proven that the percent agent in pipe may work as a key factor in testing, evaluating, and determining the limitations and performance of gaseous fire extinguishing systems, especially compared with the hydraulic flow calculations of computer design programs of gaseous fire extinguishing systems, and will remain as such in the future. As one thing to note, however, there are some difficulties in using the unified percent agent in pipe to determine the maximum lengths of pipe networks for gaseous fire extinguishing systems, because the varying definitions used by some of the flow calculations (not in accordance with NFPA 12A definition) make it impossible to do any direct comparison of pipe lengths based on percent agent in pipe.

Cadiorespiratory effects of isoflurane-anesthetized dogs with closed chest during spontaneous two-lung and one-lung ventilation (마취된 개의 자발호흡상태에서 일측폐환기 및 양측폐환기가 심순환기 및 호흡기계에 미치는 영향)

  • Song, Young-sung;Chang, Hwa-seok;Kim, Hye-jin;Kim, Soon-shin;Choi, Joon-chul;Yang, Hee-taek;Chung, Dai-jung;Kim, Hwi-yool
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.2
    • /
    • pp.279-285
    • /
    • 2005
  • One-lung ventilation (OLV) is the isolation and selective ventilation of one lung field. OLV allows the collapse of lung lobes on the side of the thoracic surgical approach to facilitate observation of intrathoracic structures and to achieve lung immobility. OLV be achieved by endotracheal intubation with double lumen tubes or bronchial blockers. In this study, cardiopulmonary consequences of two-lung ventilation (TLV), OLV and Re-TLV (TLV after OLV) were evaluated in 5 dogs. The dogs were anesthetized with mask induction and maintained with isoflurane in oxygen. Tidal volume and respiratory rates were set to maintain end-tidal $CO_2$ at $40{\pm}2mmHg$ during instrumentation. Following instrumentation, the dogs were placed in right lateral recumbency and induced spontaneously respiration state. Effect of TLV on hemodynamic and pulmonary variables were recorded. Then, the left bronchus was obstructed by endotracheal intubation with double lumen endotracheal tube to achieve OLV state and recording was continued. After OLV, double lumen endotracheal tube was extubated, and standard endotracheal tubes was intubated again. In this study, spontaneous OLV caused significant decrease in $PaO_2$, arterial oxygen saturation, mixed-venous oxygen saturation, and increase in $PaCO_2$. Especially, a significant elevation in $PaCO_2$ and respiratory acidosis were remarkable findings. So spontaneous ventilation in OLV affected gas exchange and hemodynamic function.

Studies on the Film forming Yeasts Isolated from Commercial Soy Sauce (제품(製品)간장에서 분리(分離)한 산막효모(産膜酵母)에 관(關)한 연구(硏究))

  • Chu, Young-Ha;Yu, Tai-Jong;Yu, Ju-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.61-68
    • /
    • 1975
  • This study was conducted (1) to isolate the film-forming yeast from the commercially available soy sauce, (2) to identify the state of soy sauce fermentation by the use of yeasts, (3) to confirm characteristics of yeasts. The result were as follows. 1. These yeast strains in the soy sauce fermentation test showed full fermentation of whole sugar content, reduction of the pure extract and relative reduction in total nitrogen. Soy sauce color was somehow faded to lower the stability of soy sauce. 2. In anti-fungal activity test butylparaben at a higher level 60 ppm., sodium propionate 2,400 ppm, sodium benzoate 800 ppm., menadion 165 ppm, showed their anti-fungal effect, while alcohol did not show the effect in the 3% additive group. 3. The optimum sodium chloride concentration for these strains in the 2% G.Y.P. medium was 5% and optimum temperature was $30^{\circ}C$. The extinction temperature was $62^{\circ}C$ for strain No-1 and No-3, and was $65^{\circ}C$ for No-2 and No-4. 4. The film-forming soy sauce turned out in the gas chromatogram to possess much flavor of low boiling point as compared with the standard. These flavors were considered due to flavor spoilage of the soy sauce. 5. These isolated yeasts were identified Saccharomyces rouxii (film-forming yeast) in the Lodder's taxanomic study.

  • PDF

Enhanced TPH Degradation of Diesel-Contaminated Soil by Microwave Heating (디젤오염토양의 TPH 분해를 위한 마이크로파의 가열특성)

  • Jung, Byung-Gil;Kim, Dae-Yong;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.479-484
    • /
    • 2008
  • The application of microwave technology has been investigated in the remediation of diesel-contaminated soil. The paper deals with economic assessment by means of cost analysis and degradation characteristics at different microwave powers for total petroleum hydrocarbon (TPH) in diesel contaminated soils. The soils from S Mountain around the D University were sampled. The samples were screened with 2.0 mm mesh and dried for 6 hours before the diesel was added into the dried soils. The diesel-contaminated soil (3,300 mg THP/kg soil) was prepared with diesel (S Co.). The drying process was carried out in a microwave oven, a standard household appliance with a 2,450 MHz frequency and 700 W of power. The experiments were conducted from 0 to 20 minutes as the microwave powers increased from 350W to 500W to 700W. The concentrations of TPH were analysed using a gas chromatography/mass spectrometer (GC/MS). The initial concentration of TPH was 3,300 mg TPH/kg soil. The weight of contaminated soil was 200g. The concentration of TPH was decreased to 1,828 mg TPH/kg soil (44.7%), 1,347 mg TPH/kg soil (59.2%) and 1,014 mg TPH/kg soil (69.3%) at 350W, 500W and 700W for 15 minutes respectively. In addition, the curve was best fit with first order kinetics using the least-square method. The ranges of a first order rate constant k and r-square were $0.0298{\sim}0.0375min^{-1}$ and $0.9373{\sim}0.9541$ respectively.

An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era (포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

Efficiency Improvement Research in Proton Exchange Membrane Fuel Cell (고분자전해질형 연료전지의 효율향상에 대한 연구)

  • Jang, Haer-Yong;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.149-154
    • /
    • 2005
  • Fuel cell performance evaluation logic was developed using G-language (LabVIEW) to measure performance stability. Degree of stability and reliability of performance data were improved with averaged value and standard deviation method. Water injection system was introduced and the performance using this method was comparable to that of conventional humidification method. Water injection system has advantage of lowering operation energy consumption, reducing the number of parts needed in humidification, therefore increasing efficiency of fuel cell system. Fuel cell performance was decreased in case of low temperature operation such as sub freezing condition. Air purge method was tested to reduce the water content in cell fixture before sub freezing condition. The performance degradation due to low temperature operation was minimized by air purge method in medium size cell fixture ($25cm^2$) case.