• Title/Summary/Keyword: $CO_2$ measurement

Search Result 1,585, Processing Time 0.039 seconds

Temperature measurement of the spray flame using micro scale absorption bands and line strength (마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

An Investigation into Air Quality of Main Roads in Busan using Mobile Platform Measurement (이동 측정방법을 사용한 부산지역 주요 도로의 대기오염도 조사)

  • Do, Woo-Gon;Jung, Woo-Sik;Yoo, Eun-Chul;Kwak, Jin
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1199-1211
    • /
    • 2013
  • Mobile sources produce a significant fraction of total anthropogenic emissions in Korea and have harmful effects on air quality. Mobile emissions are intrinsically difficult to estimate due to complicated road networks and variations of traffic volume with location and time. To measure traffic pollutants with high temporal and spatial resolution under real conditions a mobile laboratory was designed. The mobile laboratory provide concentrations of $SO_2$, CO, NO, $NO_2$ and location coordinate value. This approach allowed for pollutant level measurements on many roads within short periods of time. In this study, on-road concentrations of $SO_2$, CO, NO and $NO_2$ were measured using mobile platform measurement along the 25 main roads in Busan to estimate the average air pollution level in short time difference. The measurements were conducted on favorable meteorological days from 2010 to 2012 and the overall concentrations of $SO_2$, CO, NO and $NO_2$ were 0.006, 0.8, 0.182 and 0.055 ppm respectively. The result showed that the concentration of CO, NO and $NO_2$ on road were twice, 18 times and 2.5 times higher than regional air quality monitoring sites mean in same period.

Point Cloud Measurement Using Improved Variance Focus Measure Operator

  • Yeni Li;Liang Hou;Yun Chen;Shaoqi Huang
    • Current Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.170-182
    • /
    • 2024
  • The dimensional accuracy and consistency of a dual oil circuit centrifugal fuel nozzle are important for fuel distribution and combustion efficiency in an engine combustion chamber. A point cloud measurement method was proposed to solve the geometric accuracy detection problem for the fuel nozzle. An improved variance focus measure operator was used to extract the depth point cloud. Compared with other traditional sharpness evaluation functions, the improved operator can generate the best evaluation curve, and has the least noise and the shortest calculation time. The experimental results of point cloud slicing measurement show that the best window size is 24 × 24 pixels. In the height measurement experiment of the standard sample block, the relative error is 2.32%, and in the fuel nozzle cone angle measurement experiment, the relative error is 2.46%, which can meet the high precision requirements of a dual oil circuit centrifugal fuel nozzle.

DESIGN OF A VIBRATION AND STRESS MEASUREMENT SYSTEM FOR AN ADVANCED POWER REACTOR 1400 REACTOR VESSEL INTERNALS COMPREHENSIVE VIBRATION ASSESSMENT PROGRAM

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.249-256
    • /
    • 2013
  • In accordance with the US Nuclear Regulatory Commission (US NRC), Regulatory Guide 1.20, the reactor vessel internals comprehensive vibration assessment program (RVI CVAP) has been developed for an Advanced Power Reactor 1400 (APR1400). The purpose of the RVI CVAP is to verify the structural integrity of the reactor internals to flow-induced loads prior to commercial operation. The APR1400 RVI CVAP consists of four programs (analysis, measurement, inspection, and assessment). Thoughtful preparation is essential to the measurement program, because data acquisition must be performed only once. The optimized design of a vibration and stress measurement system for the RVI CVAP is essential to verify the integrity of the APR1400 RVI. We successfully designed a vibration and stress measurement system for the APR1400 RVI CVAP based on the design materials, the hydraulic and structural analysis results, and performance tests of transducers in an extreme environment. The measurement system designed in this paper will be utilized for the APR1400 RVI CVAP as part of the first construction project in Korea.

Development of Plantar Pressure Measurement System and Personal Classification Study based on Plantar Pressure Image

  • Ho, Jong Gab;Kim, Dae Gyeom;Kim, Young;Jang, Seung-wan;Min, Se Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.11
    • /
    • pp.3875-3891
    • /
    • 2021
  • In this study, a Velostat pressure sensor was manufactured to develop a plantar pressure measurement system and a C#-based application was developed to monitor and collect plantar pressure data in real time. In order to evaluate the characteristics of the proposed plantar pressure measurement system, the accuracy of plantar pressure index and personal classification was verified by comparing with MatScan, a commercial plantar pressure measurement system. As a result, the output characteristics according to the weight of the Velostat pressure sensor were evaluated and a trend line with the reliability of r2 = 0.98 was detected. The Root Mean Square Error(RMSE) of the weighted area was 11.315 cm2, the RMSE of the x coordinate of Center of Pressure(CoPx) was 1.036 cm and the RMSE of the y coordinate of Center of Pressure(CoPy) was 0.936 cm. Finally, inaccuracy of personal classification, the proposed system was 99.47% and MatScan was 96.86%. Based on the advantage of being simple to implement and capable of manufacturing at low cost, it is considered that it can be applied to various fields of measuring vital signs such as sitting posture and breathing in addition to the plantar pressure measurement system.

Characteristics of Quadrupole Mass Spectrometer for Partial Pressure Measurement in CO-$H_2$ Gas Mixture (CO와 $H_2$ 혼합기체에 대한 Quadrupole Mass Spectrometer의 감도 특성)

  • 신용현;홍승수;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.3
    • /
    • pp.314-318
    • /
    • 1993
  • Quadrupole mass spectrometer는 부분압 측정 및 잔류기체 분석에 널리 이용되고 있는 장비이다. CO, H2, Ar이 혼합되어 존재할 때 quadrupole mass spectrometer의 감도를 10-4∼10-8torr영역에서 측정하고 단일기체로 존재할 때의 감도와 비교하였다. 그 결과 일정한 부분압을 유지하고 있는 경우라도, 주위 분위기 기체 종류와 부위기 기체 압력에 따라 감도 별화가 심한 것을 알 수 있었다. 따라서 QMS를 부분압 측정이나 조성분석에 이용하기 위해서는 이에 대한 특성조사가 반드시 필요하다.

  • PDF

$\textrm{CO}_2$ Concentration Measurement (3) (탄산가스($\textrm{CO}_2$) 농도의 계측 (3))

  • 류관희
    • Journal of Bio-Environment Control
    • /
    • v.2 no.1
    • /
    • pp.65-68
    • /
    • 1993
  • 탄산가스는 탄소나 그 화합물이 완전연소할 때, 생물이 호흡할 때, 발효 등에 의하여 생성되는 무색, 무취의 기체로 분자식은 $CO_2$(이산화탄소)이며, 분자량은 44, 비중은 공기 1에 대하여 1.529이다. 식물은 탄산가스와 물을 원료로 태양에너지를 이용하여 탄수화물을 합성하므로 탄산가스는 광합성에 절대적으로 필요하며, 탄산가스가 충분하게 공급되지 않으면 광합성이 원활하게 이루어질 수가 없다. 일반적으로 식물은 대기중의 농도(0.03%)보다 높은 농도에서 포화점을 갖고 있으므로 대기중에서의 탄산가스의 농도는 식물의 광합성작용에 충분하지 못하며, 생육촉진을 위해서는 인위적인 방법으로 탄산가스 농도를 증가시키는 방법이 실용화되고 있다.(중략)

  • PDF

Development of on-line bending stiffness tester - (2) Lab experiment (종이 휨강성 자동 측정방식의 개발과 그 이용 - (2) 실험실 측정)

  • Seo, Yung-Bum;Jung, Seok-Myun;Jung, Tae-Young
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2007.04a
    • /
    • pp.235-250
    • /
    • 2007
  • A simple method of on-line stiffness measurement using the wrinkling behavior of paper web between rollers was presented. The theory and calculating equation were presented, and lab experiment was executed. We called the stiffness measured by Taber tester as 'Taber stiffness', and by tension wrinkling measurement as 'wrinkle stiffness', respectively, for comparison. Lab experimental results showed Taber and wrinkle stiffness are almost equivalent. We expect this method will work porperly for the on-line measurement of paper stiffness in near future.

  • PDF

Development of On-line Bending Stiffness Tester (2) - Lab experiment - (종이 휨강성 자동 측정방식의 개발과 그 이용 (2) - 실험실 측정 -)

  • Seo, Yung-Bum;Jung, Suk-Myun;Jung, Tae-Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.4
    • /
    • pp.21-28
    • /
    • 2007
  • A simple method of on-line stiffness measurement using the wrinkling behavior of paper web between two rollers was presented. The theory and the equation were presented, and lab and mill tests were executed. We called the stiffness measured by Taber tester as 'Taber stiffness', and by tension wrinkling measurement as 'wrinkle stiffness', respectively. Lab experimental results showed Taber and wrinkle stiffness are almost equivalent. In the mill experiment, we could measure the stiffness in the wet state and in the dry state. The dry wrinkle stiffness was close to the taber stiffness, but the wet wrinkle stiffness was much lower than the corresponding taber stiffness.

SURFACE CHARACTERIZATION OF CU ELECTRODES IN ELECTROCHEMICAL REDUCTION OF $CO_2$ BY CORE LEVEL X-RAY PHOTOELECTRON SPECTROSCOPY AND VALENCE LEVEL PHOTOELECTRON EMISSION MEASUREMENT

  • Terunuma, Y.;Saitoh, A.;Momose, Y.
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.728-734
    • /
    • 1996
  • To obtain the relation in the electrochemical reduction of $CO_2$ in aqueous $KHCO_3$ colution between an activity for the product and the nature of Cu electrode, the electrode surface was characterized by using two methods: X-ray photoelectron spectroscopy (XPS) and photoelectron emission (PE) measurement. Electrolyses were performed with Cu electrodes pretreated in several ways. The distribution of the products changed drastically with electrolysis time and the pretreatment method. The features in XPS spectra were closely connected with the product distribution. The oxide film at the electrode surface was gradually reduced to bare Cu metal with electrolysis time, resulting in a variation of the product distribution. PE was measured by verying the wavelength of incident light at several temperatures. The dependence of PE on the measurement temperature changed greatly before and after electrolysis.

  • PDF