• Title/Summary/Keyword: $CO_2$ measurement

Search Result 1,588, Processing Time 0.031 seconds

The Effects of CO2 Enrichment on the Radial Growth of Pinus densiflora

  • En-Bi CHOI;Hyemin LIM;Jeong-Wook SEO
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.3
    • /
    • pp.289-299
    • /
    • 2024
  • The current study aimed to investigate the impact of CO2 enrichment on the width of annual tree rings, earlywood and latewood, and the area of annual growth of Pinus densiflora Siebold & Zucc. grown in open-top chamber (OTC). To this end, two CO2 enrichment cases were considered, namely 1.4 × increment (560 ppm in OTC-II) and 1.8 × (720 ppm in OTC-III) were compared with the current atmosphere (400 ppm in OTC-I). The CO2 enrichment conditions for a period of 12 years (2010-2021) were considered, and all measurements were done through image analysis. The study showed that the increment in CO2 concentrations positively affected the tree growth. The measurement data from the trees in OTC-III were considerably higher than those from OTC-I, whereas those from OTC-II were slightly higher than those from OTC-I. Decreasing patterns of the measured widths and area in 6-7 years after the beginning of CO2 enrichment was found for all the OTCs. These patterns were possibly due to changes in the physiological features, such as aging. The findings of the present study can have potential uses as fundamental data for forest management considering CO2 concentrations.

Accuracy Evaluation of Tidal Volume Measured on the Abdomen (복부에서 측정하는 일회 호흡용적의 정확도 평가)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1298-1303
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. This study implemented respiratory monitoring system with the conductive rubber cord in the patient's pants in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%$ $CO_2$ was inhaled and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation significantly increased the tidal volume in normal physiological state with the subject unawared. The tidal volume estimated from the abdominal dimension change linearly correlated with the tidal volume measured by a pneumotachometer with a correlation coefficient of 0.88. Customized calibration for each subject resulted in relative errors less than 10%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

An Experimental Investigation into the Characteristics of Sampling Module for East-Response Co2 Concentration Analyzer with NDIR (비분산 적외선 분광법을 이용한 Co2농도 고속 분석기의 Sampling Module 특성에 관한 실험적 연구)

  • Kim, Woo-Seok;Shon, Deok-Young;Park, Young-Moo;Yoo, Jae-Suk;Lee, Jong-Hwa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.398-405
    • /
    • 2003
  • A fast response analyzer for measuring carbon dioxide concentration has been developed for transient characteristic and researches tested on internal combustion engine. The analyzer uses the well known NDIR(Non-Dispersive Infrared) method with miniaturized detection system, giving a time constant of approximately 30 microsecond, and sampling module consists of capillary tube. Since the transit time and the time constant of the sampling system depend on the sampling conditions, it is necessary to investigate the characteristics of sampling system before applied to exhaust gas measurement in engine. A unique method was designed to study the influence of the diameter of transfer sample line and operating conditions of the FRNDIR on transit time and time constant. A database of transit time and time constant was built up for different measured and simulated pressure conditions. The database can be used for correcting eventual $CO_2$ concentration measurement.

Measurement of magnetic kerr rotation and faraday fotation angles by polarization modulation method (편광 변조 방법에 의한 자기 Kerr 회전각 및 Faraday 회전각 측정)

  • 이용호;이상수;이용호
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.2
    • /
    • pp.105-110
    • /
    • 1992
  • In order to measure fine rotation angles by magneto-optic effects of magneto-optical recording thin films, a polarization modulation method is used. In the experiment, the polarization of laser (He-Ne laser) beam is modulated by a Faraday rotator and the amplified modulated signals are selectively detected by phase sensitive detector. The magnetic Kerr rotation and Faraday rotation hysteresis loops are investigated by this method for thermally evaporated amorphous TbFeCo thin films and RF sputtered garnet thin films. Rotation angles about $0.25^{\circ}$ are measured easily from TaFeCo thin films. In the case of longitudinal Kerr rotation, very small rotation angle of $2.5\times10^{-3^\circ}$ is measured with good accuracy of the measurement (about $1\times10^{-3^\circ}$). And it is found that each thin films have the hysteresis curves of high coercivity and good squareness.

  • PDF

Structural Characterization of the (TEX)$Sr_2Co_0.5Nb(Ta)_0.5O_4$(/TEX) and (TEX)$Sr_3CoNb(Ta)O_7$(/TEX)

  • Jo, Han Sang;Ri-Zhu Yin;Ryu, Gwang Hyeon;Yu, Cheol Hyeon
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.7
    • /
    • pp.679-684
    • /
    • 2000
  • The Sr2Co0.5Nb(Ta)0.5O4 and Sr3CoNb(Ta)O7 compounds, both with Ruddlesden-Popper structures, have been synthesized by the ceramic method at $1150^{\circ}C$ under atmospheric pressure. The crystallographic structure of the compounds was assigned to the tetr agonal system with space group 14/mmm by X-ray diffraction(XRD) Rietveld refinement. The reduced lattice volume and lattice parameters increased as the Ta with 5d substitutes for the Nb with 4d in the compounds. The Co/Nb(Ta)O bond length has been determined by X-ray absorption spectroscopic(EXAFS/XANES) analysis and the XRD refinement. The CoO6,octahedra were tetragonally distorted by elongation of Co-O bond along the c-axis. The magnetic measurement shows the compounds Sr2Co0.5Nb(Ta)0.5O4 and Sr3CoNb(Ta)O7 have paramagnetic properties and the Co ions with intermediate spin sates between high and low spins in D4h symmetry. All the compounds showed semiconducting behavior whose electrical conductivity increased with temperature up to 1000 K. The electrical conductiviy increased and the activation energy for the conduction decreased as the number of perovskite layers increased in the compounds with chemical formula An+1BnO3n+1.

Studies on Electroanalytical Chemistry for the Oxygen Adducted Tetradentate Schiff base Cobalt(III) Complexes in Pyridine Solution (Pyridine 용액에서 산소 첨가된 네자리 Schiff base Cobalt(III) 착물들의 전기 분석화학적 연구)

  • Rim, Chae-Pyeong;Chae, Hee-Nam;Chjo, Ki-Hyung;Choi, Yong-Kook
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.55-62
    • /
    • 1995
  • Tetradentate Schiff base cobalt(II) complexes such as $Co(II)_2-N$, N-bis(salicylidene)-m-phenylendiimine; [$Co(II)_2(SMPD)_2(H_2O)_4$] and $Co(II)_2-N$, N-bis(salicylidene)-p-phenylendiimine: [$Co(II)_2(SPPD)_2(H_2O)_4$], and oxygen adducted cobalt (III) complexes such as [$Co(III)_2O_2(SMPD)_2(Py)_2$] and [$Co(III)_2O_2(SPPD)_2(Py)_2$] in pyridine solutions were synthesized. It was identified that the oxygen adducted cobalt(III) complexes have hexacoordinated octahedral configuration with pyridine and oxygen from the measurement of elemental analysis, AA, IR spectra, and TGA. The redox processes were investigated for the oxygen adducted complexes in 0.1M TEAP-pyridine solution, using cyclic voltammetry on the glassy carbon electrode. The redox processes of oxygen adducted Co(III) complexes result in $$[Co(III)_2-O_2-CO(III)]\rightarrow^{e^-}[Co(III)-O_2-Co(II)]\rightarrow^{e^-}[Co(II)-O_2-Co(II)]\rightleftarrows^{e^-}[Co(II)+Co(II)+O_2{\cdot}^-]\rightleftarrows^{e^-}[Co(II)+Co(I)+O_2{\cdot}^-]\rightleftarrows^{e^-}[Co(I)+Co(I)+O_2{\cdot}^-]$$.

  • PDF

Characterization of the 2.5 MeV ELV electron accelerator electron source angular distribution using 3-D dose measurement and Monte Carlo simulations

  • Chang M. Kang;Seung-Tae Jung;Seong-Hwan Pyo;Youjung Seo;Won-Gu Kang;Jin-Kyu Kim;Young-Chang Nho;Jong-Seok Park;Jae-Hak Choi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4678-4684
    • /
    • 2023
  • Using the Monte Carlo method, the impact of the angular distribution of the electron source on the dose distribution for the 2.5 MeV ELV electron accelerator was explored. The experiment measured the 3-D dose distribution in the irradiation chamber for electron energies of 1.0 MeV and 2.5 MeV. The simulation used the MCNP6.2 code to evaluate three angular distribution models of the source: a mono-directional beam, a cone shape, and a triangular shape. Of the three models, the triangular shape with angles θ = 30°, φ = 0° best represents the angle of the scan hood through which the electron beam exits. The MCNP6.2 simulation results demonstrated that the triangular model is the most accurate representation of the angular distribution of the electron source for the 2.5 MeV ELV electron accelerator.

Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air (대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정)

  • Kim, Jong Bum;Kim, Danbi;Noh, Sujin;Yoon, Kwan Hoon;Park, Duckshin;Lee, Jeong Joo;Kim, Jeongho
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

Study on the measurement of Kimchi maturity by weight measuring method (중량법에 의한 김치 숙성도 판정에 관한 연구)

  • Park, Woo-Po;Lee, Sang-Jun;Kim, Ze-Uook
    • Applied Biological Chemistry
    • /
    • v.33 no.3
    • /
    • pp.257-260
    • /
    • 1990
  • The weight increasing rate of soda lime, absorbing carbon $dioxide(CO_2)$ generated during fermentation at $25^{\circ}C$, was measured In investigate the maturity of Kimchi at every 6 hours. The increasing rate was maximum at 36hours It was compatible with pH, titrable acidity and sensory evaluation test in optimum curing time. So, this method is thought as useful one for the measurement of the maturity of Kimchi.

  • PDF